Oleh Zemlianskyi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Oleh Zemlianskyi has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Tetiana Kostenko
National University of Civil Protection of Ukraine
5 shared publications Олег Землянський
National University of Civil Defence of Ukraine
5 shared publicationsOksana Kyrychenko
Cherkasy Institute of Fire Safety name after Chornobyl Heroes , Ukraine
3 shared publications- Олег Мирошник
Черкаський інститут пожежної безпеки імені Героїв Чорнобиля Національного університету цивільного захисту України
3 shared publications - Maryna Tavrel
Technical University “Metinvest Polytechnic” LLC
2 shared publications - Olha Bohomaz
Technical University “Metinvest Polytechnic” LLC
2 shared publications
Latest Publications
- Open Access
- 28 April 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (10 (140)) , 24-31
Defining patterns in heating a reinforced concrete column under the effect of a standard fire temperature regime
This study investigates the process of heating a fragment of a reinforced concrete column under standard fire temperature conditions. The task addressed relates to the lack of data on temperatures at characteristic points of the cross-section of reinforced concrete columns during their heating according to the standard temperature curve, which complicates the refinement of calculation models of heat transfer and assessment of fire resistance of structures. This paper identifies the features of heating a fragment of a reinforced concrete column based on the results of experimental tests in a small-sized fire furnace without applying mechanical load. Temperatures were recorded at six characteristic points of the cross-section of the studied sample, in particular at the level of the reinforcement, in the center of the cross-section, at the control point of the semi-diagonal, and at points close to the concrete surface. It was established that the maximum temperatures at the surface points reached 528°C, and in the reinforcement zone – 506°C, while in the central part of the cross-section they were equal to 468–487°C. The results showed the absence of local overheating in the planes of thermocouple placement, the formation of a regular temperature gradient in the concrete cross-section during standard fire exposure. A feature of the results is the experimental determination of temperatures at several characteristic points of the column cross-section, which allows a more accurate assessment of the real temperatures in the reinforcement and concrete during a fire. The findings are associated with the radiation-convective heat exchange between the concrete surface and the flame, as well as with the relatively low thermal conductivity and thermal inertia of the concrete material. Statistical processing of the results showed that the relative deviation of temperature values does not exceed 6.7% while the values of the Cochrane Fisher and Student criteria are less than critical. The obtained experimental data could be used to further determine the fire resistance limit of reinforced concrete columns and refine the calculation models of heat transfer
- 28 April 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (10 (140)) , 24-31
Open AccessDefining patterns in heating a reinforced concrete column under the effect of a standard fire temperature regime
This study investigates the process of heating a fragment of a reinforced concrete column under standard fire temperature conditions. The task addressed relates to the lack of data on temperatures at characteristic points of the cross-section of reinforced concrete columns during their heating according to the standard temperature curve, which complicates the refinement of calculation models of heat transfer and assessment of fire resistance of structures. This paper identifies the features of heating a fragment of a reinforced concrete column based on the results of experimental tests in a small-sized fire furnace without applying mechanical load. Temperatures were recorded at six characteristic points of the cross-section of the studied sample, in particular at the level of the reinforcement, in the center of the cross-section, at the control point of the semi-diagonal, and at points close to the concrete surface. It was established that the maximum temperatures at the surface points reached 528°C, and in the reinforcement zone – 506°C, while in the central part of the cross-section they were equal to 468–487°C. The results showed the absence of local overheating in the planes of thermocouple placement, the formation of a regular temperature gradient in the concrete cross-section during standard fire exposure. A feature of the results is the experimental determination of temperatures at several characteristic points of the column cross-section, which allows a more accurate assessment of the real temperatures in the reinforcement and concrete during a fire. The findings are associated with the radiation-convective heat exchange between the concrete surface and the flame, as well as with the relatively low thermal conductivity and thermal inertia of the concrete material. Statistical processing of the results showed that the relative deviation of temperature values does not exceed 6.7% while the values of the Cochrane Fisher and Student criteria are less than critical. The obtained experimental data could be used to further determine the fire resistance limit of reinforced concrete columns and refine the calculation models of heat transfer
- Open Access
- 28 October 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (10 (137)) , 77-86
Building a model of water jet motion exiting a fire hose
This study investigates the process of water jet motion in the air; the subject is the trajectory of motion and the velocity vector of water droplets in a two-phase "droplets-air" flow. The task addressed is to construct a model of water jet motion in the air, which would take into account its destruction and transformation into a stream of droplets. A model of water jet motion in the field of gravity after exiting the fire hydrant in the area of the jet core has been built. The jet expansion coefficient was experimentally determined to be 0.016. Estimates of the jet radius, water droplet velocity, and effective radius of the jet of trapped air at the boundary of the core zone and the droplet zone were constructed. The values obtained are the initial conditions for the model of the motion of the droplet and gas phases of the jet in the droplet zone. The droplet motion was modeled by using the Lagrangian approach, within which the dynamics of the motion of individual drops were considered, described by the equations of motion in three-dimensional space taking into account the forces of aerodynamic resistance and gravity. It was assumed that the distribution of the droplet diameter obeys the Rosin-Ramler law. A model of the motion of the gas phase of the jet was constructed, based on the equations of mass and momentum balance; it also takes into account the curvature of the jet axis due to the capture of air by drops moving under the action of gravity. The model is based on the assumption of the axisymmetric nature of the jet and the Gaussian velocity distribution in its cross section. A feature of the model is the mutual influence of the droplet and gas phases of the jet on the motion of each other: drops, losing momentum due to aerodynamic resistance, give it to the air. It is shown that drops of smaller diameter have a shorter range compared to drops of larger diameter. As a result, the water falls to the ground not at a specific point but in a certain range. In particular, for a fire hose with a diameter of 19 mm, a delivery angle of 35° to the horizon and a water pressure of (40÷70) m, the width of the range into which 90% of the water falls was (8.7÷11.0) m
- 28 October 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (10 (137)) , 77-86
Open AccessBuilding a model of water jet motion exiting a fire hose
This study investigates the process of water jet motion in the air; the subject is the trajectory of motion and the velocity vector of water droplets in a two-phase "droplets-air" flow. The task addressed is to construct a model of water jet motion in the air, which would take into account its destruction and transformation into a stream of droplets. A model of water jet motion in the field of gravity after exiting the fire hydrant in the area of the jet core has been built. The jet expansion coefficient was experimentally determined to be 0.016. Estimates of the jet radius, water droplet velocity, and effective radius of the jet of trapped air at the boundary of the core zone and the droplet zone were constructed. The values obtained are the initial conditions for the model of the motion of the droplet and gas phases of the jet in the droplet zone. The droplet motion was modeled by using the Lagrangian approach, within which the dynamics of the motion of individual drops were considered, described by the equations of motion in three-dimensional space taking into account the forces of aerodynamic resistance and gravity. It was assumed that the distribution of the droplet diameter obeys the Rosin-Ramler law. A model of the motion of the gas phase of the jet was constructed, based on the equations of mass and momentum balance; it also takes into account the curvature of the jet axis due to the capture of air by drops moving under the action of gravity. The model is based on the assumption of the axisymmetric nature of the jet and the Gaussian velocity distribution in its cross section. A feature of the model is the mutual influence of the droplet and gas phases of the jet on the motion of each other: drops, losing momentum due to aerodynamic resistance, give it to the air. It is shown that drops of smaller diameter have a shorter range compared to drops of larger diameter. As a result, the water falls to the ground not at a specific point but in a certain range. In particular, for a fire hose with a diameter of 19 mm, a delivery angle of 35° to the horizon and a water pressure of (40÷70) m, the width of the range into which 90% of the water falls was (8.7÷11.0) m
- Open Access
- 1 June 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 26 (6) , 29-36
Experimental study of the hydrodynamically reagent for energy saving
The paper deals with the topical, however controversial issue of the impact on the hydrodynamic resistance of polymer solutions of certain reagents that have proven to be already used in water supply for water disinfection, have anticorrosive activity and are safe for humans and the environment....
- 1 June 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 26 (6) , 29-36
Open AccessExperimental study of the hydrodynamically reagent for energy saving
The paper deals with the topical, however controversial issue of the impact on the hydrodynamic resistance of polymer solutions of certain reagents that have proven to be already used in water supply for water disinfection, have anticorrosive activity and are safe for humans and the environment....
- Open Access
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 48-56
COMPREHENSIVE SOLUTIONS FOR AUTOMATIC FIRE SUPPRESSION OF ELECTRIC VEHICLE BATTERIES
The growing number of electric vehicles worldwide presents new challenges related to fire hazards. Spontaneous combustion of batteries may result from overheating, damage, or short circuits. This article aims to develop a comprehensive solution for an automatic fire suppression system for electric vehicle batteries. Considering the structural characteristics of a battery pack of an electric vehicle, one of the most effective ways to suppress a fire is by coolingthe battery cells with water. Fire suppression efficiency can be improved by implementing design modifications to the battery housing, including the addition of water supply and drainage pipelines. This enables the development of an automatic fire suppression system that functions while the vehicle is parked or charging. In the event of a fire while an electric vehicle is in motion, the presence of pipelines will facilitate faster response by fire and rescue units.To determine the key parameters of an automatic fire suppression system for electric vehicles, appropriate methods are proposed to assess the required amount of water for a specific vehicle model, the maximum water consumption for fire suppression, and the necessary pipeline diameters. The systemis controlled by a PID controller, ensuring a rapid and appropriate response to combustion events in electric vehicle batteries while minimising the risk of uncontrolled fire spread. The scientific novelty of this study lies in the development of a methodological framework for enhancing fire suppression systems for electric vehicle batteries by establishing methods for determining the key parameters of an automatic fire suppression system. The practical significance of the obtained results lies in the formulation of design proposals for an automatic fire suppression system for an electric vehicle that manufacturers can implement in practice.Keywords:electric vehicle, battery, fire, fire hazards, automatic fire suppression system, extinguishing agent
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 48-56
Open AccessCOMPREHENSIVE SOLUTIONS FOR AUTOMATIC FIRE SUPPRESSION OF ELECTRIC VEHICLE BATTERIES
The growing number of electric vehicles worldwide presents new challenges related to fire hazards. Spontaneous combustion of batteries may result from overheating, damage, or short circuits. This article aims to develop a comprehensive solution for an automatic fire suppression system for electric vehicle batteries. Considering the structural characteristics of a battery pack of an electric vehicle, one of the most effective ways to suppress a fire is by coolingthe battery cells with water. Fire suppression efficiency can be improved by implementing design modifications to the battery housing, including the addition of water supply and drainage pipelines. This enables the development of an automatic fire suppression system that functions while the vehicle is parked or charging. In the event of a fire while an electric vehicle is in motion, the presence of pipelines will facilitate faster response by fire and rescue units.To determine the key parameters of an automatic fire suppression system for electric vehicles, appropriate methods are proposed to assess the required amount of water for a specific vehicle model, the maximum water consumption for fire suppression, and the necessary pipeline diameters. The systemis controlled by a PID controller, ensuring a rapid and appropriate response to combustion events in electric vehicle batteries while minimising the risk of uncontrolled fire spread. The scientific novelty of this study lies in the development of a methodological framework for enhancing fire suppression systems for electric vehicle batteries by establishing methods for determining the key parameters of an automatic fire suppression system. The practical significance of the obtained results lies in the formulation of design proposals for an automatic fire suppression system for an electric vehicle that manufacturers can implement in practice.Keywords:electric vehicle, battery, fire, fire hazards, automatic fire suppression system, extinguishing agent
- Open Access
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 105-114
ASSESSMENT OF THE EFFECTIVENESS OF THE CIVIL DEFENSE SYSTEM FOR PREVENTION AND ELIMINATION OF THE CONSEQUENCES OF EMERGENCIES IN THE BORDER AREAS OF UKRAINE
The article provides a comprehensive assessment of the effectiveness of the civil protection system for the prevention and elimination of the consequences of emergencies (ES) in the border regions of Ukraine. The relevance of the study is due to the increase in the number and complexity of emergencies in the region, which have both natural and man-made, social and military origins.. Particular attention is paid to the specifics of border areas, which are an area of increased risk due to cross-border threats, the complexity of coordinating actions, and the low level of resource provision. The paper analyzes the theoretical foundations of the classification of emergencies, the regulatory and legal field, and international experience, which allowed us to highlight the peculiarities of the functioning of the civil protection system in border areas. Mathematical models have been developed to quantify response efficiency, taking into account the arrival time of rescue units, the level of resource provision, coordination between services, and public awareness. The proposed mathematical models allow predicting possible losses, identifying bottlenecks in the response system, and optimizing resource allocation. The conducted experimental study confirmed the feasibility and effectiveness of the proposed mathematical models in the context of preventing and eliminating emergencies in border regions. Analysis of simulated scenarios demonstrated a significant reduction in response time, increased efficiency of evacuation measures, and a reduction in the number of casualties. Digital solutions, prior training of personnel, and coordinated interagency cooperation played a significant role in this. The results of the study confirm the need to strengthen interagency cooperation, modernize the material and technical base, and implement modern monitoring and alerting technologies. Key words:civil protection, border areas, emergencies.
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 105-114
Open AccessASSESSMENT OF THE EFFECTIVENESS OF THE CIVIL DEFENSE SYSTEM FOR PREVENTION AND ELIMINATION OF THE CONSEQUENCES OF EMERGENCIES IN THE BORDER AREAS OF UKRAINE
The article provides a comprehensive assessment of the effectiveness of the civil protection system for the prevention and elimination of the consequences of emergencies (ES) in the border regions of Ukraine. The relevance of the study is due to the increase in the number and complexity of emergencies in the region, which have both natural and man-made, social and military origins.. Particular attention is paid to the specifics of border areas, which are an area of increased risk due to cross-border threats, the complexity of coordinating actions, and the low level of resource provision. The paper analyzes the theoretical foundations of the classification of emergencies, the regulatory and legal field, and international experience, which allowed us to highlight the peculiarities of the functioning of the civil protection system in border areas. Mathematical models have been developed to quantify response efficiency, taking into account the arrival time of rescue units, the level of resource provision, coordination between services, and public awareness. The proposed mathematical models allow predicting possible losses, identifying bottlenecks in the response system, and optimizing resource allocation. The conducted experimental study confirmed the feasibility and effectiveness of the proposed mathematical models in the context of preventing and eliminating emergencies in border regions. Analysis of simulated scenarios demonstrated a significant reduction in response time, increased efficiency of evacuation measures, and a reduction in the number of casualties. Digital solutions, prior training of personnel, and coordinated interagency cooperation played a significant role in this. The results of the study confirm the need to strengthen interagency cooperation, modernize the material and technical base, and implement modern monitoring and alerting technologies. Key words:civil protection, border areas, emergencies.
- Open Access
- 31 October 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (10 (125)) , 34-42
Determination of heat transfer process in vertical cable tunnels of nuclear power plants under real fire conditions
The object of the study was heat and mass transfer processes occurring in vertical cable tunnels. The problem to be solved was the definition of process mechanisms in the inner space of the tunnel. For this, field tests were conducted, mathematical models were created, and computational experiments were conducted to establish specific parameters that affect the temperature regime of a fire in a vertical cable tunnel of a nuclear power plant. The dynamics of temperature changes with known geometric parameters and fire load were determined, and the adequacy of mathematical models built in the Fire Dynamics Simulator software was investigated and computational experiments were carried out. It has been proven that they consist in determining the temperature regime in a vertical cable tunnel of a nuclear power plant with known technical and geometric parameters. Such studies have practical applications in the field of safety of nuclear power plants and the development of new technologies in this field. An important conclusion of these studies is the possibility of determining the fire resistance of building structures of vertical cable tunnels of nuclear power plants with the selection of the most severe temperature regime, according to the conducted field test. This means that research results can be used in practice in designing and evaluating the safety of such objects. The conducted research established that the temperature in the inner space of the tunnel can reach values from 1200 to 1400 ℃. The following factors influence the maximum temperature value and the maximum time to reach the maximum temperature in the fire cell: fire load, height and area of the tunnel. With a lower fire load, the maximum temperature in the vertical cable tunnel of the nuclear power plant was 75 % lower. Therefore, the results of these studies have a direct practical application in the field of safety of nuclear power plants and can be used to improve and develop new technologies in this field
- 31 October 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (10 (125)) , 34-42
Open AccessDetermination of heat transfer process in vertical cable tunnels of nuclear power plants under real fire conditions
The object of the study was heat and mass transfer processes occurring in vertical cable tunnels. The problem to be solved was the definition of process mechanisms in the inner space of the tunnel. For this, field tests were conducted, mathematical models were created, and computational experiments were conducted to establish specific parameters that affect the temperature regime of a fire in a vertical cable tunnel of a nuclear power plant. The dynamics of temperature changes with known geometric parameters and fire load were determined, and the adequacy of mathematical models built in the Fire Dynamics Simulator software was investigated and computational experiments were carried out. It has been proven that they consist in determining the temperature regime in a vertical cable tunnel of a nuclear power plant with known technical and geometric parameters. Such studies have practical applications in the field of safety of nuclear power plants and the development of new technologies in this field. An important conclusion of these studies is the possibility of determining the fire resistance of building structures of vertical cable tunnels of nuclear power plants with the selection of the most severe temperature regime, according to the conducted field test. This means that research results can be used in practice in designing and evaluating the safety of such objects. The conducted research established that the temperature in the inner space of the tunnel can reach values from 1200 to 1400 ℃. The following factors influence the maximum temperature value and the maximum time to reach the maximum temperature in the fire cell: fire load, height and area of the tunnel. With a lower fire load, the maximum temperature in the vertical cable tunnel of the nuclear power plant was 75 % lower. Therefore, the results of these studies have a direct practical application in the field of safety of nuclear power plants and can be used to improve and develop new technologies in this field
- Open Access
- 4 September 2023
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 4 (178) , 199-205
CREATION OF A PORTABLE FOAM GENERATOR WITH PRACTICAL RESEARCH CONDUCTED
The article describes the process of modeling and creating a compact portable foam generator of medium multiplicity with geometric and dimensional parameters that allow for the use of air-mechanical foam directly during reconnaissance without complicating circumstances that arise during reconnaissance with a gas and smoke protection service when it is necessary to supply air-mechanical foam without a foam generator, which is not included in the minimum necessary list of firefighting tools and devices. Generally, the use of foam generators by the gas and smoke protection service during fires is a common practice and constitutes typical actions in case of fire incidents. However, there is one particular aspect in the use of generators - their weight and geometric dimensions, which may restrict the movement of personnel in relatively confined spaces such as cable tunnels, basements, and underground structures. Therefore, greater attention should be paid to the use of foam generators with medium multiplicity. The foam isolates the combustion zone from flammable vapors and gases, as well as the combustible surface of the material from the heat emitted by the reaction zone. It penetrates well into the premises, overcomes turns and climbs, quickly fills the volume of the room, displaces combustion products heated to high temperatures, thereby reducing the temperature in the room. To ensure instant response to the situation during reconnaissance with a gas and smoke protection service, equipment should be provided that allows for confident response to complex tactical tasks for the fire suppression commander, making informed and decisive decisions regarding reducing the likelihood of emergency situations and reducing the percentage of human and material losses. The motto of a rescuer is "prevent, save, help." This article describes a useful model that reduces the decision-making time for the fire suppression commander at the end of reconnaissance, the time of initiating the first fire extinguishing nozzle, the time of fire localization and extinguishment, which increases the likelihood of saving human lives from fire hazards. Keywords: compact medium expansion foam generator, air-mechanical foam, gas and smoke protection service.
- 4 September 2023
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 4 (178) , 199-205
Open AccessCREATION OF A PORTABLE FOAM GENERATOR WITH PRACTICAL RESEARCH CONDUCTED
The article describes the process of modeling and creating a compact portable foam generator of medium multiplicity with geometric and dimensional parameters that allow for the use of air-mechanical foam directly during reconnaissance without complicating circumstances that arise during reconnaissance with a gas and smoke protection service when it is necessary to supply air-mechanical foam without a foam generator, which is not included in the minimum necessary list of firefighting tools and devices. Generally, the use of foam generators by the gas and smoke protection service during fires is a common practice and constitutes typical actions in case of fire incidents. However, there is one particular aspect in the use of generators - their weight and geometric dimensions, which may restrict the movement of personnel in relatively confined spaces such as cable tunnels, basements, and underground structures. Therefore, greater attention should be paid to the use of foam generators with medium multiplicity. The foam isolates the combustion zone from flammable vapors and gases, as well as the combustible surface of the material from the heat emitted by the reaction zone. It penetrates well into the premises, overcomes turns and climbs, quickly fills the volume of the room, displaces combustion products heated to high temperatures, thereby reducing the temperature in the room. To ensure instant response to the situation during reconnaissance with a gas and smoke protection service, equipment should be provided that allows for confident response to complex tactical tasks for the fire suppression commander, making informed and decisive decisions regarding reducing the likelihood of emergency situations and reducing the percentage of human and material losses. The motto of a rescuer is "prevent, save, help." This article describes a useful model that reduces the decision-making time for the fire suppression commander at the end of reconnaissance, the time of initiating the first fire extinguishing nozzle, the time of fire localization and extinguishment, which increases the likelihood of saving human lives from fire hazards. Keywords: compact medium expansion foam generator, air-mechanical foam, gas and smoke protection service.
- Open Access
- 1 June 2023
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 24 (4) , 79-87
Studying the Effect of Mineral Fertilizers on the Development of the Eutrophication Process in the Water Bodies
The article is devoted to the disclosure of the effect on the vital activity of cyanobacteria by changes in the nutrients in the chemical composition of artificial aquatic biotopes. The research results allowed us to establish that the dissolution of complex mineral fertilizer (nitrogen,...
- 1 June 2023
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 24 (4) , 79-87
Open AccessStudying the Effect of Mineral Fertilizers on the Development of the Eutrophication Process in the Water Bodies
The article is devoted to the disclosure of the effect on the vital activity of cyanobacteria by changes in the nutrients in the chemical composition of artificial aquatic biotopes. The research results allowed us to establish that the dissolution of complex mineral fertilizer (nitrogen,...
- Open Access
- 29 April 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (5 (122)) , 31-37
Improving the manufacturing technology of sensing gas sensors based on zinc oxide by using the method of magnetron sputtering on direct current
A gas sensor based on zinc oxide obtained by magnetron spraying at direct current was investigated. There are methods of deposition of zinc oxide nanostructures such as thermal evaporation, chemical vapor deposition, organometallic chemical vapor deposition, magnetron sputtering, pulsed laser deposition, and hydrothermal process. The least investigated is magnetron sputtering. To obtain films, a vacuum unit VUP-5M with an original material-saving magnetron was used. Studies into the sensitivity and speed of the gas sensor based on ZnO with respect to the target gas – ethanol of different concentrations – were carried out. The resulting experimental dependences of the sensitivity of the gas sensor on the concentration of the target gas demonstrate that with increasing concentration of the target gas, the resistance decreased while the sensitivity of the sample increased. It was established that the change in the resistance of the test sample is proportional to the change in the concentration of the target gas. After the sensor surface becomes saturated with adsorbed molecules, the resistance no longer decreases, even if the gas concentration continues to increase. The reaction of the gas sensor to the target gas – ethanol – at concentrations above 150 ppm was almost absent. The time required to achieve the maximum response value should be lower at higher target gas concentrations. Sensitivity reaction repeatability studies were conducted to measure the resistance of a gas sensor based on ZnO in a target gas atmosphere with a concentration of 150 ppm. It was found that the gas sensor demonstrates excellent stability and consistent sensitivity reaction when re-exposed to the target gas – ethanol. It was established that the reaction time of a gas sensor based on ZnO to the target gas at each repeated exposure does not exceed 10 s. This repeatability index allows us to assert the stability of the ZnO-based gas sensor in an ethanol atmosphere under standard conditions
- 29 April 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (5 (122)) , 31-37
Open AccessImproving the manufacturing technology of sensing gas sensors based on zinc oxide by using the method of magnetron sputtering on direct current
A gas sensor based on zinc oxide obtained by magnetron spraying at direct current was investigated. There are methods of deposition of zinc oxide nanostructures such as thermal evaporation, chemical vapor deposition, organometallic chemical vapor deposition, magnetron sputtering, pulsed laser deposition, and hydrothermal process. The least investigated is magnetron sputtering. To obtain films, a vacuum unit VUP-5M with an original material-saving magnetron was used. Studies into the sensitivity and speed of the gas sensor based on ZnO with respect to the target gas – ethanol of different concentrations – were carried out. The resulting experimental dependences of the sensitivity of the gas sensor on the concentration of the target gas demonstrate that with increasing concentration of the target gas, the resistance decreased while the sensitivity of the sample increased. It was established that the change in the resistance of the test sample is proportional to the change in the concentration of the target gas. After the sensor surface becomes saturated with adsorbed molecules, the resistance no longer decreases, even if the gas concentration continues to increase. The reaction of the gas sensor to the target gas – ethanol – at concentrations above 150 ppm was almost absent. The time required to achieve the maximum response value should be lower at higher target gas concentrations. Sensitivity reaction repeatability studies were conducted to measure the resistance of a gas sensor based on ZnO in a target gas atmosphere with a concentration of 150 ppm. It was found that the gas sensor demonstrates excellent stability and consistent sensitivity reaction when re-exposed to the target gas – ethanol. It was established that the reaction time of a gas sensor based on ZnO to the target gas at each repeated exposure does not exceed 10 s. This repeatability index allows us to assert the stability of the ZnO-based gas sensor in an ethanol atmosphere under standard conditions
- Open Access
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (1) , 191-201
THERMODYNAMIC CALCULATIONS FOR DETERMINING THE TEMPERATURE OF COMBUSTION PRODUCTS OF PYROTECHNIC PRODUCTS BASED ON ALUMINUM-MAGNESIUM ALLOY POWDER
This article is devoted to the study of the fire-hazardous properties of pyrotechnic products based on powders of aluminum-magnesium alloys with a nitrate-containing oxidizer (NaNO3). The article presents thermodynamic calculations of temperature and composition of combustion products of these products depending on the ratio of components and the state of the environment. The obtained results make it possible to determine possible fire-hazardous situations at the stage of development and design of pyrotechnic products based on them. Such information helps prevent possible fires and accidents when storing and launching pyrotechnic products. Дану статтю присвячено дослідженню пожежонебезпечних властивостей піротехнічних виробів на основі порошків алюмінієво-магнієвих сплавів з нітратовмісним окиснювачем (NaNO3). У статті представлено термодинамічні розрахунки температури та складу продуктів згоряння цих виробів в залежності від співвідношення компонентів та стану навколишнього середовища. Отримані результати дозволяють визначати можливі пожежонебезпечні ситуації на стадії розробки та проектування піротехнічних виробів на їх основі. Така інформація допомагає запобігти можливим пожежам та нещасним випадкам при зберіганні та запуску піротехнічних виробів.
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (1) , 191-201
Open AccessTHERMODYNAMIC CALCULATIONS FOR DETERMINING THE TEMPERATURE OF COMBUSTION PRODUCTS OF PYROTECHNIC PRODUCTS BASED ON ALUMINUM-MAGNESIUM ALLOY POWDER
This article is devoted to the study of the fire-hazardous properties of pyrotechnic products based on powders of aluminum-magnesium alloys with a nitrate-containing oxidizer (NaNO3). The article presents thermodynamic calculations of temperature and composition of combustion products of these products depending on the ratio of components and the state of the environment. The obtained results make it possible to determine possible fire-hazardous situations at the stage of development and design of pyrotechnic products based on them. Such information helps prevent possible fires and accidents when storing and launching pyrotechnic products. Дану статтю присвячено дослідженню пожежонебезпечних властивостей піротехнічних виробів на основі порошків алюмінієво-магнієвих сплавів з нітратовмісним окиснювачем (NaNO3). У статті представлено термодинамічні розрахунки температури та складу продуктів згоряння цих виробів в залежності від співвідношення компонентів та стану навколишнього середовища. Отримані результати дозволяють визначати можливі пожежонебезпечні ситуації на стадії розробки та проектування піротехнічних виробів на їх основі. Така інформація допомагає запобігти можливим пожежам та нещасним випадкам при зберіганні та запуску піротехнічних виробів.