MHMatthew J. F. Healy

Matthew J. F. Healy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthew J. F. Healy has a total of 97 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Support to triage and public risk perception considering long-term response to a Cs-137 radiological dispersive device scenario

    by Cristiane Ps Andrade, Cláudio J Souza, Eduardo Sn Camerini, Isabela S Alves, Hélio C Vital, Matthew Jf Healy, Edson Ramos De Andrade

    A radiological dispersive device (RDD) spreads radioactive material, complicates the treatment of physical injuries, raises cancer risk, and induces disproportionate fear. Simulating such an event enables more effective and efficient utilization of the triage and treatment resources of staff, facilities, and space. Fast simulation can give detail on events in progress or future events. The resources for triage and treatment of contaminated trauma victims can differ for pure exposure individuals, while discouraging the “worried well” from presenting in the crisis phase by media announcement would relieve pressure on hospital facilities. The proposed methodology integrates capabilities from different platforms in a convergent way composed of three phases: (a) scenario simulation, (b) data generation, and (c) risk assessment for triage focused on follow-up epidemiological assessment. Simulations typically indicate that most of the affected population does not require immediate medical assistance. Medical triage for the few severely injured and the radiological triage to diminish the contamination with radioactivity will always be the priority. For this study, however, higher priorities should be given to individuals from radiological “warm” and “hot” zones as required by risk criteria. The proposed methodology could thus help to (a) filter and reduce the number of individuals to be attended, (b) optimize the prioritization of medical care, (c) reduce or prepare for future costs, (d) effectively locate the operational triage site to avoid possible contamination on the main facility, and (e) provide the scientific data needed to develop an adequate approach to risk and its proper communication.


  • X-ray backscatter radiography with lower open fraction coded masks

    by Andre M. A. Munoz, David W. Lane, Matthew J. F. Healy, Anna Vella, David Lockley, Ian D. Jupp


  • Open Access

    3D-printed coded apertures for x-ray backscatter radiography

    by Ian D. Jupp, Andre M. A. Munoz, David W. Lane, Matthew J. F. Healy, Anna Vella, David Lockley


  • A fast and reliable approach to simulating the output from an x-ray tube used for developing security backscatter imaging

    by Joseph G. Zhou, David Lockley, Anna Vella, Andre M. A. Munoz, Matthew J. F. Healy, David W. Lane

    The PENELOPE Monte Carlo simulation code was used alongside the SpekCalc code to simulate X-ray energy spectra from a VJ Technologies’ X-ray generator at a range of anode voltages. The PENELOPE code is often utilised in medicine but is here applied to develop coded aperture and pinhole imaging systems for security purposes. The greater computational burden of PENELOPE over SpekCalc is warranted by its greater flexibility and output information. The model was designed using the PENGEOM sub-tool and consists of a tungsten anode and five layers of window materials. The photons generated by a mono-energetic electron beam are collected by a virtual detector placed after the last window layer, and this records the spatial, angular and energy distributions which are then used as the X-ray source for subsequent simulations. The process of storing X-ray outputs and using them as a virtual photon source can then be used efficiently for exploring a range of imaging conditions as the computationally expensive electron interactions in the anode need not be repeated. The modelled spectra were validated with experimentally determined spectra collected with an Amptek X-123 Cadmium Telluride detector placed in front of the source.Copyright 2017 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited


  • The use of simulation to optimize the pinhole diameter and mask thickness for an x-ray backscatter imaging system

    by Anna Vella, Andre M. A. Munoz, Matthew J. F. Healy, David W. Lane, David Lockley

    The PENELOPE Monte Carlo simulation code was used to determine the optimum thickness and aperture diameter of a pinhole mask for X-ray backscatter imaging in a security application. The mask material needs to be thick enough to absorb most X-rays, and the pinhole must be wide enough for sufficient field of view whilst narrow enough for sufficient image spatial resolution. The model consisted of a fixed geometry test object, various masks with and without pinholes, and a 1040 x 1340 pixels’ area detector inside a lead lined camera housing. The photon energy distribution incident upon masks was flat up to selected energy limits. This artificial source was used to avoid the optimisation being specific to any particular X-ray source technology. The pixelated detector was modelled by digitising the surface area represented by the PENELOPE phase space file and integrating the energies of the photons impacting within each pixel; a MATLAB code was written for this. The image contrast, signal to background ratio, spatial resolution, and collimation effect were calculated at the simulated detector as a function of pinhole diameter and various thicknesses of mask made of tungsten, tungsten/epoxy composite or bismuth alloy. A process of elimination was applied to identify suitable masks for a viable X-ray backscattering security application.Copyright 2017 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited

  • Open Access

    Radiological Risk Assessment by Convergence Methodology Model in RDD Scenarios

    by Fagner C. Rother, Wilson F. Rebello, Matthew J. F. Healy, Mauricio M. Silva, Paulo A. M. Cabral, Hélio C. Vital, Edson R. Andrade

    A radiological dispersal device (RDD) is a simple weapon capable of causing human harm, environmental contamination, disruption, area denial, and economic cost. It can affect small, large, or long areas depending on atmospheric stability. The risk of developing a radio‐induced cancer depends on exposure, and an effective response depends upon available timely guidance. This article proposes and demonstrates a convergence of three different capabilities to assess risk and support rapid safe resource efficient response. The three capabilities that are integrated are Hotspot for dispersion, RERF for epidemiological risk, and RESRAD‐RDD for response guidance. The combined methodology supports decisions on risk reduction and resource allocation through work schedules, the designation and composition of response teams, and siting for operations. In the illustrative RDD scenario, the contamination area for sheltering, evacuation, and long‐term public concern was greatest for calm atmospheric conditions, whilst close‐quarter responders faced highest dose rates for neutral atmospheric conditions. Generally, the risks to women responders were found to be significantly greater than for men, and the risks to 20‐year‐old responders were three times that of their 60‐year‐old counterparts for similar exposure.


  • Open Access

    A framework for the systematic realisation of phenomena for enhanced sensing of radiological and nuclear materials, and radiation

    by M J F Healy

    The quest for new sensing phenomena continues because detecting, discriminating, identifying, measuring and monitoring nuclear materials and their radiation from greater range, at lower concentrations, and in a more timely fashion brings greater safety, security and efficiency. The potential phenomena are diverse, and those that have been realised can be found in disparate fields of science, engineering and medicine, which makes the full range difficult to realise and record. The framework presented here offers a means to systematically and comprehensively explore nuclear sensing phenomena. The approach is based on the fundamental concepts of matter and energy, where the sequence starts with the original nuclear material and its emissions, and progressively considers signatures arising from secondary effects and the emissions from associated materials and the environment. Concepts of operations such as active and passive interrogation, and networked sensing are considered. In this operational light, unpacking nuclear signatures forces a fresh look at the sensing concept. It also exposes how some phenomena that exist in established technology may be considered novel based on how they could be exploited rather than what they fundamentally are. This article selects phenomena purely to illustrate the framework and how it can be best used to foster creativity in the quest for novel phenomena rather than exhaustively listing, categorising or comparing any practical aspects of candidate phenomena.

  • Open Access

    Effects of different needles and substrates on CuInS2 deposited by electrostatic spray deposition

    by S. Roncallo, J.D. Painter, M.J.F. Healy, S.A. Ritchie, M.V. Finnis, K.D. Rogers, J.J. Scragg, P.J. Dale, G. Zoppi


  • A Model to Support CBRN Defence

    by M. J.F. Healy, K. Weston, M. Romilly, K. Arbuthnot

    (2009). A Model to Support CBRN Defence. Defense & Security Analysis: Vol. 25, No. 2, pp. 119-135.