AMAndre Arelius Marcus Muñoz

Andre Arelius Marcus Muñoz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andre Arelius Marcus Muñoz has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low open fraction coded masks for x-ray backscatter imaging

    by Andre Arelius Marcus Muñoz, Anna Vella, Matthew J. F. Healy, David W. Lane, Ian Jupp, David Lockley

    Previous research has indicated that coded masks with open fractions <0.5 are optimal for imaging some types of far-field scenes. The open fraction, in this case, refers to the ratio of open elements in the mask, with values <0.5 considered as low open fraction. Research is limited by the sparsity of <0.5 open fractions masks; thus a further 94 lower open fraction arrays are calculated and presented. These include the dilute uniformly redundant array and singer set, along with information on imaging potential, array sizes, and open fractions. Signal-to-noise ratio reveals the 0.5 open fraction modified uniformly redundant array to be the optimal coded mask for near-field x-ray backscatter imaging, over the lower open fraction singer set, dilute uniformly redundant and random array.


  • Open Access

    Rapid prototyping-coded masks for x-ray backscatter imaging

    by Andre A. M. Muñoz, Anna Vella, Matthew J. F. Healy, David W. Lane, Ian Jupp, David Lockley

    Coded masks (CM) often lack a self-supporting structure that is difficult to manufacture without recourse to drilled holes in place of ideal square apertures, degrading imaging properties. An alternative approach is presented with three-dimensional (3-D) printed CM molds cast with a radio-opaque material that allows square elements to be retained. Two methods are presented; hot casting a bismuth alloy (density 8.6 g cm  −  3) and cold casting with tungsten powder/epoxy resin (densities 9.6 and 10.6 g cm  −  3). A critical review of 3-D printed-CM fabrication along with some typical x-ray backscatter images is presented. A signal-to-noise ratio from both the machined tungsten and cold cast 3-D printed mask were comparable, with the former having a slight advantage. Also, 3-D printed cold cast masks were found to be more economical and easier to rapid prototype over traditional drilled tungsten masks.


  • X-ray backscatter radiography with lower open fraction coded masks

    by Andre M. A. Munoz, David W. Lane, Matthew J. F. Healy, Anna Vella, David Lockley, Ian D. Jupp


  • Open Access

    3D-printed coded apertures for x-ray backscatter radiography

    by Ian D. Jupp, Andre M. A. Munoz, David W. Lane, Matthew J. F. Healy, Anna Vella, David Lockley


  • A fast and reliable approach to simulating the output from an x-ray tube used for developing security backscatter imaging

    by Joseph G. Zhou, David Lockley, Anna Vella, Andre M. A. Munoz, Matthew J. F. Healy, David W. Lane

    The PENELOPE Monte Carlo simulation code was used alongside the SpekCalc code to simulate X-ray energy spectra from a VJ Technologies’ X-ray generator at a range of anode voltages. The PENELOPE code is often utilised in medicine but is here applied to develop coded aperture and pinhole imaging systems for security purposes. The greater computational burden of PENELOPE over SpekCalc is warranted by its greater flexibility and output information. The model was designed using the PENGEOM sub-tool and consists of a tungsten anode and five layers of window materials. The photons generated by a mono-energetic electron beam are collected by a virtual detector placed after the last window layer, and this records the spatial, angular and energy distributions which are then used as the X-ray source for subsequent simulations. The process of storing X-ray outputs and using them as a virtual photon source can then be used efficiently for exploring a range of imaging conditions as the computationally expensive electron interactions in the anode need not be repeated. The modelled spectra were validated with experimentally determined spectra collected with an Amptek X-123 Cadmium Telluride detector placed in front of the source.Copyright 2017 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited


  • The use of simulation to optimize the pinhole diameter and mask thickness for an x-ray backscatter imaging system

    by Anna Vella, Andre M. A. Munoz, Matthew J. F. Healy, David W. Lane, David Lockley

    The PENELOPE Monte Carlo simulation code was used to determine the optimum thickness and aperture diameter of a pinhole mask for X-ray backscatter imaging in a security application. The mask material needs to be thick enough to absorb most X-rays, and the pinhole must be wide enough for sufficient field of view whilst narrow enough for sufficient image spatial resolution. The model consisted of a fixed geometry test object, various masks with and without pinholes, and a 1040 x 1340 pixels’ area detector inside a lead lined camera housing. The photon energy distribution incident upon masks was flat up to selected energy limits. This artificial source was used to avoid the optimisation being specific to any particular X-ray source technology. The pixelated detector was modelled by digitising the surface area represented by the PENELOPE phase space file and integrating the energies of the photons impacting within each pixel; a MATLAB code was written for this. The image contrast, signal to background ratio, spatial resolution, and collimation effect were calculated at the simulated detector as a function of pinhole diameter and various thicknesses of mask made of tungsten, tungsten/epoxy composite or bismuth alloy. A process of elimination was applied to identify suitable masks for a viable X-ray backscattering security application.Copyright 2017 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited