Ming-Jer Jeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ming-Jer Jeng has a total of 187 co-authors. Here are the top co-authors by number of shared publications:
- Liann-Be Chang
Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan
59 shared publications - Jianping Ao
Institute of Photoelectronic Thin Film Devices and Technology and Tianjin Key Laboratory of Thin film Devices and Technology, Nankai University, Tianjin 300071, China
6 shared publications - Lee Chow
Department of Physics, University of Central Florida, Orlando, FL 32816, USA
6 shared publications - Mukta Sharma
Department of Electronic Engineering, Chang Gung University, Taoyuan 333, Taiwan
6 shared publications Sung-Cheng Hu
6 shared publicationsYu-Lin Lee
6 shared publications
Latest Publications
- Open Access
Properties of FAPbI3-Based Alloy Perovskite Thin Films and Their Application in Solar Cells
Surface morphologies, light harvesting abilities, crystal structures, and excitonic properties of the formamiminium lead triiodide (FAPbI3) based alloy perovskite thin films were investigated by using the scanning electron microscopic images, absorbance spectra, X-ray diffraction patterns, photoluminescence (PL) spectra and time-resolved PL decaying curves. Our experimental results show that the fresh CsxFA1−xPbI3, RbxFA1−xPbI3, and FAPb(SCNxI1−x)3 alloy thin films are a pure α-phase perovskite crystal, a α-phase: δ-phase mixed perovskite crystal, and a PbI2 crystal/α-phase: δ-phase mixed perovskite crystal at room temperatures, respectively. Among the three FAPbI3 based alloy perovskite solar cells, the CsxFA1−xPbI3 solar cells have the better photovoltaic responses. It is noted that the high photocurrent density is mainly due to the formation of cube-like surface morphology and the long carrier lifetime of 368 ns when the CsxFA1−xPbI3 alloy perovskite thin film is used as the light-absorbing layer. Our findings provide the relation between the properties of the FAPbI3 based alloy perovskite thin films and the photovoltaic responses of the resultant solar cells.
Open AccessProperties of FAPbI3-Based Alloy Perovskite Thin Films and Their Application in Solar Cells
Surface morphologies, light harvesting abilities, crystal structures, and excitonic properties of the formamiminium lead triiodide (FAPbI3) based alloy perovskite thin films were investigated by using the scanning electron microscopic images, absorbance spectra, X-ray diffraction patterns, photoluminescence (PL) spectra and time-resolved PL decaying curves. Our experimental results show that the fresh CsxFA1−xPbI3, RbxFA1−xPbI3, and FAPb(SCNxI1−x)3 alloy thin films are a pure α-phase perovskite crystal, a α-phase: δ-phase mixed perovskite crystal, and a PbI2 crystal/α-phase: δ-phase mixed perovskite crystal at room temperatures, respectively. Among the three FAPbI3 based alloy perovskite solar cells, the CsxFA1−xPbI3 solar cells have the better photovoltaic responses. It is noted that the high photocurrent density is mainly due to the formation of cube-like surface morphology and the long carrier lifetime of 368 ns when the CsxFA1−xPbI3 alloy perovskite thin film is used as the light-absorbing layer. Our findings provide the relation between the properties of the FAPbI3 based alloy perovskite thin films and the photovoltaic responses of the resultant solar cells.
- Open Access
- 18 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (16) , 4829
Raman Spectral Characterization of Urine for Rapid Diagnosis of Acute Kidney Injury
Acute kidney injury (AKI) is a common syndrome characterized by various etiologies and pathophysiologic processes that deteriorate kidney function. The aim of this study is to identify potential biomarkers in the urine of non-acute kidney injury (non-AKI) and AKI patients through Raman spectroscopy (RS) to predict the advancement in complications and kidney failure. Selected spectral regions containing prominent peaks of renal biomarkers were subjected to partial least squares linear discriminant analysis (PLS-LDA). This discriminant analysis classified the AKI patients from non-AKI subjects with a sensitivity and specificity of 97% and 100%, respectively. In this study, the RS measurements of urine specimens demonstrated that AKI had significantly higher nitrogenous compounds, porphyrin, tryptophan and neopterin when compared with non-AKI. This study’s specific spectral information can be used to design an in vivo RS approach for the detection of AKI diseases.
- 18 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (16) , 4829
Open AccessRaman Spectral Characterization of Urine for Rapid Diagnosis of Acute Kidney Injury
Acute kidney injury (AKI) is a common syndrome characterized by various etiologies and pathophysiologic processes that deteriorate kidney function. The aim of this study is to identify potential biomarkers in the urine of non-acute kidney injury (non-AKI) and AKI patients through Raman spectroscopy (RS) to predict the advancement in complications and kidney failure. Selected spectral regions containing prominent peaks of renal biomarkers were subjected to partial least squares linear discriminant analysis (PLS-LDA). This discriminant analysis classified the AKI patients from non-AKI subjects with a sensitivity and specificity of 97% and 100%, respectively. In this study, the RS measurements of urine specimens demonstrated that AKI had significantly higher nitrogenous compounds, porphyrin, tryptophan and neopterin when compared with non-AKI. This study’s specific spectral information can be used to design an in vivo RS approach for the detection of AKI diseases.
- Open Access
- 9 November 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (11) , 1165
Developing an Algorithm for Discriminating Oral Cancerous and Normal Tissues Using Raman Spectroscopy
The aim of this study was to investigate the clinical potential of Raman spectroscopy (RS) in detecting oral squamous cell carcinoma (OSCC) in tumor and healthy tissues in surgical resection specimens during surgery. Raman experiments were performed on cryopreserved specimens from patients with OSCC. Univariate and multivariate analysis was performed based on the fingerprint region (700–1800 cm) of the Raman spectra. One hundred thirty-one ex-vivo Raman experiments were performed on 131 surgical resection specimens obtained from 67 patients. The principal component analysis (PCA) and partial least square (PLS) methods with linear discriminant analysis (LDA) were applied on an independent validation dataset. Both models were able to differentiate between the tissue types, but PLS–LDA showed 100% accuracy, sensitivity, and specificity. In this study, Raman measurements of fresh resection tissue specimens demonstrated that OSCC had significantly higher nucleic acid, protein, and several amino acid contents than adjacent healthy tissues. The specific spectral information obtained in this study can be used to develop an in vivo Raman spectroscopic method for the tumor-free resection boundary during surgery.- 9 November 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (11) , 1165
Open AccessDeveloping an Algorithm for Discriminating Oral Cancerous and Normal Tissues Using Raman Spectroscopy
The aim of this study was to investigate the clinical potential of Raman spectroscopy (RS) in detecting oral squamous cell carcinoma (OSCC) in tumor and healthy tissues in surgical resection specimens during surgery. Raman experiments were performed on cryopreserved specimens from patients with OSCC. Univariate and multivariate analysis was performed based on the fingerprint region (700–1800 cm) of the Raman spectra. One hundred thirty-one ex-vivo Raman experiments were performed on 131 surgical resection specimens obtained from 67 patients. The principal component analysis (PCA) and partial least square (PLS) methods with linear discriminant analysis (LDA) were applied on an independent validation dataset. Both models were able to differentiate between the tissue types, but PLS–LDA showed 100% accuracy, sensitivity, and specificity. In this study, Raman measurements of fresh resection tissue specimens demonstrated that OSCC had significantly higher nucleic acid, protein, and several amino acid contents than adjacent healthy tissues. The specific spectral information obtained in this study can be used to develop an in vivo Raman spectroscopic method for the tumor-free resection boundary during surgery. - Open Access
- 10 May 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (5) , 106
A Surface Acoustic Wave Sensor with a Microfluidic Channel for Detecting C-Reactive Protein
A surface acoustic wave (SAW) sensor with a microfluidic channel was studied to detect C-reactive protein (CRP). A piezoelectric lithium niobate substrate was used to examine the frequency response of the microfluidic SAW sensor. The amplitude (insertion loss) changes in the microfluidic SAW sensor were measured from the interaction of CRP/anti-CRP owing to mass variation. The fabricated microfluidic SAW sensor exhibited a detection limit of 4 ng/mL CRP concentration. A wide CRP concentration range (10 ng/mL to 0.1 mg/mL) can be detected by this sensor, which is higher than the existing CRP detection methods. A good linear relationship between the amplitude peak shift and CRP concentrations from 10 ng/mL to 0.1 mg/mL was obtained. The amplitude peak shifts in the sensor can be useful for estimating CRP concentration. This can be used as a biosensor to diagnose the risk of cardiovascular disease.
- 10 May 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (5) , 106
Open AccessA Surface Acoustic Wave Sensor with a Microfluidic Channel for Detecting C-Reactive Protein
A surface acoustic wave (SAW) sensor with a microfluidic channel was studied to detect C-reactive protein (CRP). A piezoelectric lithium niobate substrate was used to examine the frequency response of the microfluidic SAW sensor. The amplitude (insertion loss) changes in the microfluidic SAW sensor were measured from the interaction of CRP/anti-CRP owing to mass variation. The fabricated microfluidic SAW sensor exhibited a detection limit of 4 ng/mL CRP concentration. A wide CRP concentration range (10 ng/mL to 0.1 mg/mL) can be detected by this sensor, which is higher than the existing CRP detection methods. A good linear relationship between the amplitude peak shift and CRP concentrations from 10 ng/mL to 0.1 mg/mL was obtained. The amplitude peak shifts in the sensor can be useful for estimating CRP concentration. This can be used as a biosensor to diagnose the risk of cardiovascular disease.
- Open Access
Surface Acoustic Wave Sensor for C-Reactive Protein Detection
A surface acoustic wave (SAW) sensor was investigated for its application in C-reactive protein (CRP) detection. Piezoelectric lithium niobate (LiNbO3) substrates were used to study their frequency response characteristics in a SAW sensor with a CRP sensing area. After the fabrication of the SAW sensor, the immobilization process was performed for CRP/anti-CRP interaction. The CRP/anti-CRP interaction can be detected as mass variations in the sensing area. These mass variations may produce changes in the amplitude of sensor response. It was clearly observed that a CRP concentration of 0.1 μg/mL can be detected in the proposed SAW sensor. A good fitting linear relationship between the detected insertion loss (amplitude) and the concentrations of CRP from 0.1 μg/mL to 1 mg/mL was obtained. The detected shifts in the amplitude of insertion loss in SAW sensors for different CRP concentrations may be useful in the diagnosis of risk of cardiovascular diseases.
Open AccessSurface Acoustic Wave Sensor for C-Reactive Protein Detection
A surface acoustic wave (SAW) sensor was investigated for its application in C-reactive protein (CRP) detection. Piezoelectric lithium niobate (LiNbO3) substrates were used to study their frequency response characteristics in a SAW sensor with a CRP sensing area. After the fabrication of the SAW sensor, the immobilization process was performed for CRP/anti-CRP interaction. The CRP/anti-CRP interaction can be detected as mass variations in the sensing area. These mass variations may produce changes in the amplitude of sensor response. It was clearly observed that a CRP concentration of 0.1 μg/mL can be detected in the proposed SAW sensor. A good fitting linear relationship between the detected insertion loss (amplitude) and the concentrations of CRP from 0.1 μg/mL to 1 mg/mL was obtained. The detected shifts in the amplitude of insertion loss in SAW sensors for different CRP concentrations may be useful in the diagnosis of risk of cardiovascular diseases.
- Open Access
Novel Quantitative Analysis Using Optical Imaging (VELscope) and Spectroscopy (Raman) Techniques for Oral Cancer Detection
In this study, we developed a novel quantitative analysis method to enhance the detection capability for oral cancer screening. We combined two different optical techniques, a light-based detection technique (visually enhanced lesion scope) and a vibrational spectroscopic technique (Raman spectroscopy). Materials and methods: Thirty-five oral cancer patients who went through surgery were enrolled. Thirty-five cancer lesions and thirty-five control samples with normal oral mucosa (adjacent to the cancer lesion) were analyzed. Thirty-five autofluorescence images and 70 Raman spectra were taken from 35 cancer and 35 control group cryopreserved samples. The normalized intensity and heterogeneity of the 70 regions of interest (ROIs) were calculated along with 70 averaged Raman spectra. Linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA) were used with principal component analysis (PCA) to differentiate the cancer and control groups (normal). The classifications rates were validated using two different validation methods, leave-one-out cross-validation (LOOCV) and k-fold cross-validation. Results: The cryopreserved normal and tumor tissues were differentiated using the PCA–LDA and PCA–QDA models. The PCA–LDA of Raman spectroscopy (RS) had 82.9% accuracy, 80% sensitivity, and 85.7% specificity, while ROIs on the autofluorescence images were differentiated with 90% accuracy, 100% sensitivity, and 80% specificity. The combination of two optical techniques differentiated cancer and normal group with 97.14% accuracy, 100% sensitivity, and 94.3% specificity. Conclusion: In this study, we combined the data of two different optical techniques. Furthermore, PCA–LDA and PCA–QDA quantitative analysis models were used to differentiate tumor and normal groups, creating a complementary pathway for efficient tumor diagnosis. The error rates of RS and VELcope analysis were 17.10% and 10%, respectively, which was reduced to 3% when the two optical techniques were combined.
Open AccessNovel Quantitative Analysis Using Optical Imaging (VELscope) and Spectroscopy (Raman) Techniques for Oral Cancer Detection
In this study, we developed a novel quantitative analysis method to enhance the detection capability for oral cancer screening. We combined two different optical techniques, a light-based detection technique (visually enhanced lesion scope) and a vibrational spectroscopic technique (Raman spectroscopy). Materials and methods: Thirty-five oral cancer patients who went through surgery were enrolled. Thirty-five cancer lesions and thirty-five control samples with normal oral mucosa (adjacent to the cancer lesion) were analyzed. Thirty-five autofluorescence images and 70 Raman spectra were taken from 35 cancer and 35 control group cryopreserved samples. The normalized intensity and heterogeneity of the 70 regions of interest (ROIs) were calculated along with 70 averaged Raman spectra. Linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA) were used with principal component analysis (PCA) to differentiate the cancer and control groups (normal). The classifications rates were validated using two different validation methods, leave-one-out cross-validation (LOOCV) and k-fold cross-validation. Results: The cryopreserved normal and tumor tissues were differentiated using the PCA–LDA and PCA–QDA models. The PCA–LDA of Raman spectroscopy (RS) had 82.9% accuracy, 80% sensitivity, and 85.7% specificity, while ROIs on the autofluorescence images were differentiated with 90% accuracy, 100% sensitivity, and 80% specificity. The combination of two optical techniques differentiated cancer and normal group with 97.14% accuracy, 100% sensitivity, and 94.3% specificity. Conclusion: In this study, we combined the data of two different optical techniques. Furthermore, PCA–LDA and PCA–QDA quantitative analysis models were used to differentiate tumor and normal groups, creating a complementary pathway for efficient tumor diagnosis. The error rates of RS and VELcope analysis were 17.10% and 10%, respectively, which was reduced to 3% when the two optical techniques were combined.
- Open Access
Annealing-Dependent Breakdown Voltage and Capacitance of Gallium Oxide-Based Gallium Nitride MOSOM Varactors
Our laboratory has previously revealed the use of metal-semiconductor-metal (MSM) varactors against malicious pulses, as well as completed the related verification and measurements of such a circuit. To improve the reliability of this protection module further, in this study, we deposited a gallium oxide (Ga2O3) thin film in between the Schottky contact electrode to manufacture a metal-oxide-semiconductor-oxide-metal (MOSOM) varactor. However, the thin-film quality and heterojunction interfaces will affect these fabricated varactors in various ways, such as the asymmetry threshold voltage to the variable capacitance characteristics. This study aims to address the issues associated with the inserted oxide thin film, as well as to determine how improvements could be obtained by using an oxygen furnace annealing process. As a result, the breakdown voltage of the MOSOM varactor was further promoted and a more robust anti-surge module was thus realized.
Open AccessAnnealing-Dependent Breakdown Voltage and Capacitance of Gallium Oxide-Based Gallium Nitride MOSOM Varactors
Our laboratory has previously revealed the use of metal-semiconductor-metal (MSM) varactors against malicious pulses, as well as completed the related verification and measurements of such a circuit. To improve the reliability of this protection module further, in this study, we deposited a gallium oxide (Ga2O3) thin film in between the Schottky contact electrode to manufacture a metal-oxide-semiconductor-oxide-metal (MOSOM) varactor. However, the thin-film quality and heterojunction interfaces will affect these fabricated varactors in various ways, such as the asymmetry threshold voltage to the variable capacitance characteristics. This study aims to address the issues associated with the inserted oxide thin film, as well as to determine how improvements could be obtained by using an oxygen furnace annealing process. As a result, the breakdown voltage of the MOSOM varactor was further promoted and a more robust anti-surge module was thus realized.
- 30 June 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (11) , 6823-6828
The Characteristics of Perovskite Solar Cells Fabricated Using DMF and DMSO/GBL Solvents
- 30 June 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (11) , 6823-6828
The Characteristics of Perovskite Solar Cells Fabricated Using DMF and DMSO/GBL Solvents
- Open Access
- 10 April 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (11) , 6798-6805
GaN 2DEG Varactor-Based Impulse Suppression Module for Protection Against Malicious Electromagnetic Interference
A GaN-based metal–semiconductor–metal varactor with a two-dimensional electron gas (2DEG) layer is proposed and fabricated. The capacitance variation of this fabricated varactor biased at different external voltages is studied and measured, and the frequency-dependent capacitance and resistance of the varactor are simulated by a corresponding empirical formula. A high-frequency protective filter is further constructed and placed under a large pulsed-current injection in a malicious electromagnetic interference immunity test. The results show that the proposed GaN-based module can reduce the large pulsed current to an acceptably small level. Thus, the GaN-based 2DEG varactor is an attractive candidate for applications designed to protect the upcoming 5G high-frequency system from risks such as electrostatic discharge, lightning, and electromagnetic pulses.
- 10 April 2020
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 49 (11) , 6798-6805
Open AccessGaN 2DEG Varactor-Based Impulse Suppression Module for Protection Against Malicious Electromagnetic Interference
A GaN-based metal–semiconductor–metal varactor with a two-dimensional electron gas (2DEG) layer is proposed and fabricated. The capacitance variation of this fabricated varactor biased at different external voltages is studied and measured, and the frequency-dependent capacitance and resistance of the varactor are simulated by a corresponding empirical formula. A high-frequency protective filter is further constructed and placed under a large pulsed-current injection in a malicious electromagnetic interference immunity test. The results show that the proposed GaN-based module can reduce the large pulsed current to an acceptably small level. Thus, the GaN-based 2DEG varactor is an attractive candidate for applications designed to protect the upcoming 5G high-frequency system from risks such as electrostatic discharge, lightning, and electromagnetic pulses.
- Open Access
Capacitance Characteristics and Breakdown Mechanism of AlGaN/GaN Metal–Semiconductor–Metal Varactors and their Anti-Surge Application
The AlGaN/GaN materials with a wide band gap, high electron mobility, and high breakdown voltage are suitable for manufacturing high-power and high-frequency electronic devices. In this study, metal Schottky contact electrodes of different dimensions are prepared on AlGaN/GaN wafers to fabricate metal–semiconductor–metal (MSM) varactors. Voltage-dependent capacitance and breakdown voltages of the varactors are measured and studied. The corresponding breakdown mechanisms of varactors with different electrode gaps are proposed. Furthermore, an anti-surge application using GaN-based MSM varactors in a signal transmission module is demonstrated, and its surge suppression capability is shown. We believe that our study will be beneficial in developing surge protection circuits for RF applications.
Open AccessCapacitance Characteristics and Breakdown Mechanism of AlGaN/GaN Metal–Semiconductor–Metal Varactors and their Anti-Surge Application
The AlGaN/GaN materials with a wide band gap, high electron mobility, and high breakdown voltage are suitable for manufacturing high-power and high-frequency electronic devices. In this study, metal Schottky contact electrodes of different dimensions are prepared on AlGaN/GaN wafers to fabricate metal–semiconductor–metal (MSM) varactors. Voltage-dependent capacitance and breakdown voltages of the varactors are measured and studied. The corresponding breakdown mechanisms of varactors with different electrode gaps are proposed. Furthermore, an anti-surge application using GaN-based MSM varactors in a signal transmission module is demonstrated, and its surge suppression capability is shown. We believe that our study will be beneficial in developing surge protection circuits for RF applications.