Latest Publications
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (11) , 8770-8778
$\alpha \alpha \beta$-Based Fast and Accurate Frequency and ROCOF Measurement in Power Systems
The frequency and rate of change of frequency (ROCOF) signals acquired from phasor measurement units (PMUs) are instrumental in the security monitoring and feedback control of power grids, necessitating minimal response time and high precision. Existing algorithms rarely achieve a simultaneous balance between superior noise filtering performance and rapid response time when measuring frequency and ROCOF. To address this problem, this article introduces an innovative algorithm that integrates $\alpha \beta \gamma$ series filters. The proposed algorithm leverages an $\alpha \alpha \beta$ (aab) filter, which combines an $\alpha$ filter and an $\alpha \beta$ filter, and the reference P-class PMU algorithm from the IEC/IEEE 60255.118.1-2018 standard file. By providing an original mathematical modeling approach to aab parameter acquisition, this filter effectively amalgamates the advantages of the two foundational filters. Extensive experimental simulations demonstrate that our proposed algorithm has exceptional performance across various metrics of frequency and ROCOF measurement, achieving results that compare favorably with other advanced algorithms.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (11) , 8770-8778
$\alpha \alpha \beta$-Based Fast and Accurate Frequency and ROCOF Measurement in Power Systems
The frequency and rate of change of frequency (ROCOF) signals acquired from phasor measurement units (PMUs) are instrumental in the security monitoring and feedback control of power grids, necessitating minimal response time and high precision. Existing algorithms rarely achieve a simultaneous balance between superior noise filtering performance and rapid response time when measuring frequency and ROCOF. To address this problem, this article introduces an innovative algorithm that integrates $\alpha \beta \gamma$ series filters. The proposed algorithm leverages an $\alpha \alpha \beta$ (aab) filter, which combines an $\alpha$ filter and an $\alpha \beta$ filter, and the reference P-class PMU algorithm from the IEC/IEEE 60255.118.1-2018 standard file. By providing an original mathematical modeling approach to aab parameter acquisition, this filter effectively amalgamates the advantages of the two foundational filters. Extensive experimental simulations demonstrate that our proposed algorithm has exceptional performance across various metrics of frequency and ROCOF measurement, achieving results that compare favorably with other advanced algorithms.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1486-1491
The Interaction Between Active Power and Synchronization Loops of PMSG Within Electromechanical Timescale
The interaction between the control links of the permanent magnet synchronous generator (PMSG) is one of the important factors that cause the instability of the PMSG grid-connected system. However, most of the researches on interaction focus on the electromagnetic timescale, and the electromechanical timescale is less involved. This paper analyzes the interaction between the active power loop and the synchronization loop of the PMSG within electromechanical timescale. Firstly, the simplified small-signal model of the PMSG single-machine infinite-bus system within electromechanical timescale is established. Then, the equivalent Heffron-Phillips model of the PMSG is proposed, and the interaction between the active power loop and the synchronization loop is quantitatively analyzed by the damping torque method. It is found that the active power loop can ‘slow down’ the dynamics of the synchronization loop, so that it belongs to electromechanical timescale. These findings provide some new insights into the interaction between the active power loop and the synchronization loop of the PMSG.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1486-1491
The Interaction Between Active Power and Synchronization Loops of PMSG Within Electromechanical Timescale
The interaction between the control links of the permanent magnet synchronous generator (PMSG) is one of the important factors that cause the instability of the PMSG grid-connected system. However, most of the researches on interaction focus on the electromagnetic timescale, and the electromechanical timescale is less involved. This paper analyzes the interaction between the active power loop and the synchronization loop of the PMSG within electromechanical timescale. Firstly, the simplified small-signal model of the PMSG single-machine infinite-bus system within electromechanical timescale is established. Then, the equivalent Heffron-Phillips model of the PMSG is proposed, and the interaction between the active power loop and the synchronization loop is quantitatively analyzed by the damping torque method. It is found that the active power loop can ‘slow down’ the dynamics of the synchronization loop, so that it belongs to electromechanical timescale. These findings provide some new insights into the interaction between the active power loop and the synchronization loop of the PMSG.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (4) , 2860-2870
Lithium-Ion Battery State of Charge Estimation With Adaptability to Changing Conditions
Accurate state of charge (SOC) estimation provides critical information to ensure the safe operation of lithium-ion batteries (LIBs). With the evolution of artificial intelligence, the model-free deep learning-based SOC estimation has made extraordinary progress. However, collecting sufficient data to train an accurate SOC estimator of batteries' whole lifecycle is costly, and generalizing the estimator to different operating conditions is challenging. To this end, aiming to enhance the generalization ability of data-driven SOC estimators, this paper proposes a novel SOC estimation framework based on adversarial transfer learning (TL), which transfers a well-trained SOC estimator with fewer data demands to fit different conditions. Specifically, a source SOC estimator is trained under a specific condition to learn the basic characteristics of the battery, which is defined as the source domain. Target domains correspond to measured data of the battery under different conditions. An adversarial TL-based training framework is developed to extract the domain invariants of the source and target domains, which is guided by minimizing the distribution discrepancies. The effectiveness of the proposed method is demonstrated through the use of two LIBs datasets. The successful generalization to multiple operating conditions and aging health states demonstrates the estimation accuracy, robustness, and good generalization.
- 13 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (4) , 2860-2870
Lithium-Ion Battery State of Charge Estimation With Adaptability to Changing Conditions
Accurate state of charge (SOC) estimation provides critical information to ensure the safe operation of lithium-ion batteries (LIBs). With the evolution of artificial intelligence, the model-free deep learning-based SOC estimation has made extraordinary progress. However, collecting sufficient data to train an accurate SOC estimator of batteries' whole lifecycle is costly, and generalizing the estimator to different operating conditions is challenging. To this end, aiming to enhance the generalization ability of data-driven SOC estimators, this paper proposes a novel SOC estimation framework based on adversarial transfer learning (TL), which transfers a well-trained SOC estimator with fewer data demands to fit different conditions. Specifically, a source SOC estimator is trained under a specific condition to learn the basic characteristics of the battery, which is defined as the source domain. Target domains correspond to measured data of the battery under different conditions. An adversarial TL-based training framework is developed to extract the domain invariants of the source and target domains, which is guided by minimizing the distribution discrepancies. The effectiveness of the proposed method is demonstrated through the use of two LIBs datasets. The successful generalization to multiple operating conditions and aging health states demonstrates the estimation accuracy, robustness, and good generalization.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1913-1923
Multi-Segment State of Health Estimation of Lithium-ion Batteries Considering Short Partial Charging
State of health (SOH) is a critical state parameter of lithium-ion batteries (LIBs). Health indicators (HIs), which are derived from the measured features of LIBs, are used in the current data-driven SOH estimation techniques to determine SOH. However, the common partial charging and discharging make it challenging to derive reliable HIs. In this paper, a SOH estimation approach considering short partial charging is proposed. Unlike other techniques, the constant current charging stage is divided into short segments, the HI, based on the charging capacity and actual initial charging voltage, is extracted within each short segment, and a kernel ridge regression-based estimator is created to characterize the SOH mapping relationship. Subsequently, an estimator fusion frame is established to merge the estimates of the eligible segments, which is decided based on the actual start and end charging voltages of the partial charging. The effectiveness of the proposed approach is validated with two well-known LIBs aging datasets containing real partial charging cycles. The results are satisfactory in terms of accuracy, robustness to partial charging, and good generality to different types of LIBs. Effective SOH value can be deduced whenever the charging voltage range covers at least one short estimation segment.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1913-1923
Multi-Segment State of Health Estimation of Lithium-ion Batteries Considering Short Partial Charging
State of health (SOH) is a critical state parameter of lithium-ion batteries (LIBs). Health indicators (HIs), which are derived from the measured features of LIBs, are used in the current data-driven SOH estimation techniques to determine SOH. However, the common partial charging and discharging make it challenging to derive reliable HIs. In this paper, a SOH estimation approach considering short partial charging is proposed. Unlike other techniques, the constant current charging stage is divided into short segments, the HI, based on the charging capacity and actual initial charging voltage, is extracted within each short segment, and a kernel ridge regression-based estimator is created to characterize the SOH mapping relationship. Subsequently, an estimator fusion frame is established to merge the estimates of the eligible segments, which is decided based on the actual start and end charging voltages of the partial charging. The effectiveness of the proposed approach is validated with two well-known LIBs aging datasets containing real partial charging cycles. The results are satisfactory in terms of accuracy, robustness to partial charging, and good generality to different types of LIBs. Effective SOH value can be deduced whenever the charging voltage range covers at least one short estimation segment.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Transient Stability Assessment and Dynamic Security Region in Power Electronics Dominated Power Systems
Transient stability accidents induced by converter-based resources have been emerging frequently around the world. In this paper, the transient stability of the grid-tied voltage source converter (VSC) system is studied through estimating the basin of attraction (BOA) based on the hyperplane or hypersurface method. Meanwhile, fault critical clearing times are estimated, based on the approximated BOA and numerical fault trajectory. Further, the dynamic security region (DSR), an important index in traditional power systems, is extended to power-electronics-dominated power systems in this paper. The DSR of VSC is defined in the space composed of active current references. Based on the estimated BOA, the single-VSC-infinite-bus system is taken as an example and its DSR is evaluated. Finally, all these analytical results are well verified by several numerical simulations in MATLAB/Simulink.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Transient Stability Assessment and Dynamic Security Region in Power Electronics Dominated Power Systems
Transient stability accidents induced by converter-based resources have been emerging frequently around the world. In this paper, the transient stability of the grid-tied voltage source converter (VSC) system is studied through estimating the basin of attraction (BOA) based on the hyperplane or hypersurface method. Meanwhile, fault critical clearing times are estimated, based on the approximated BOA and numerical fault trajectory. Further, the dynamic security region (DSR), an important index in traditional power systems, is extended to power-electronics-dominated power systems in this paper. The DSR of VSC is defined in the space composed of active current references. Based on the estimated BOA, the single-VSC-infinite-bus system is taken as an example and its DSR is evaluated. Finally, all these analytical results are well verified by several numerical simulations in MATLAB/Simulink.
- 28 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability Analysis and Subsynchronous Oscillation of Grid-Tied VSC Under Different Grid Strengths
Recently, with the development of renewable energy, the proportion of power electronic equipment in the power system has gradually increased, which makes the stability and subsynchronous oscillation (SSO) of power system more complicated. In this paper, based on the sixth-order state space model of the grid-tied voltage source converter (VSC) in the time domain, we discuss the stability domain of the system when the parameters of different controllers change under different power grid intensities. These stable regions can provide guidance for the adjustment of controller parameters. Then we further research the dynamic process of the eigenvalues when the system leaves the stable region, and verify that the situation where a single eigenvalue crosses the virtual axis only occurs when the controller parameter is negative. Finally, in the area where the system is unstable, we find that the main factor causing SSO is phase-locked loop (PLL) by comparing the bandwidth of the controller. The results are also consistent with the time domain simulation in Matlab / Simulink.
- 28 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability Analysis and Subsynchronous Oscillation of Grid-Tied VSC Under Different Grid Strengths
Recently, with the development of renewable energy, the proportion of power electronic equipment in the power system has gradually increased, which makes the stability and subsynchronous oscillation (SSO) of power system more complicated. In this paper, based on the sixth-order state space model of the grid-tied voltage source converter (VSC) in the time domain, we discuss the stability domain of the system when the parameters of different controllers change under different power grid intensities. These stable regions can provide guidance for the adjustment of controller parameters. Then we further research the dynamic process of the eigenvalues when the system leaves the stable region, and verify that the situation where a single eigenvalue crosses the virtual axis only occurs when the controller parameter is negative. Finally, in the area where the system is unstable, we find that the main factor causing SSO is phase-locked loop (PLL) by comparing the bandwidth of the controller. The results are also consistent with the time domain simulation in Matlab / Simulink.
- Open Access
- 1 January 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (1) , 014705
Internal insulation condition identification for high-voltage capacitor voltage transformers based on possibilistic fuzzy clustering
The internal insulation condition of capacitor voltage transformers (CVTs) is a key influence factor that affects their measurement performance and safe operation. However, the internal insulation would age along with long-time operation and degrade due to environmental factors, and once the insulation degradation grows, serious damage and even explosion may happen in CVTs; hence, it is necessary to monitor the internal insulation condition of CVTs, and the fault type and fault degree need to be identified. In this paper, a data-driven internal insulation condition identification method for CVTs is proposed. Both the amplitude and phase of the output voltage of CVTs are collected, and then, recognition models based on the combination of the output voltages and distribution topology of CVTs in substations are built. A possibilistic fuzzy clustering method is used to monitor the internal insulation condition of CVTs, and different types and different degrees of insulation faults could be identified effectively. Finally, the proposed method is verified in several cases; not only the preset typical faults in the method could be identified effectively but also the faults beyond the preset faults could be diagnosed.
- 1 January 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (1) , 014705
Open AccessInternal insulation condition identification for high-voltage capacitor voltage transformers based on possibilistic fuzzy clustering
The internal insulation condition of capacitor voltage transformers (CVTs) is a key influence factor that affects their measurement performance and safe operation. However, the internal insulation would age along with long-time operation and degrade due to environmental factors, and once the insulation degradation grows, serious damage and even explosion may happen in CVTs; hence, it is necessary to monitor the internal insulation condition of CVTs, and the fault type and fault degree need to be identified. In this paper, a data-driven internal insulation condition identification method for CVTs is proposed. Both the amplitude and phase of the output voltage of CVTs are collected, and then, recognition models based on the combination of the output voltages and distribution topology of CVTs in substations are built. A possibilistic fuzzy clustering method is used to monitor the internal insulation condition of CVTs, and different types and different degrees of insulation faults could be identified effectively. Finally, the proposed method is verified in several cases; not only the preset typical faults in the method could be identified effectively but also the faults beyond the preset faults could be diagnosed.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Monitoring the Ratio Error of High-Voltage CVTs Based on Local Outlier Identification
The capacitor voltage transformer (CVT) is one of the most important measurement equipment in the high-voltage (HV) power system, its metering accuracy is a key factor to ensure the safety of the power system and the fairness of the electricity trade. The conventional off-line calibration method to obtain the ratio error of CVTs is time-consuming and needs power cut, so it is no longer a suitable approach in the HV power system. In this paper, an on-line ratio error monitoring method for CVTs has been proposed, this method is based on local outlier identification. Considering the voltage fluctuations in the power system, the output voltages of CVTs are used to construct recognition models firstly, in which other fluctuation components have been eliminated except the ratio error, then the abnormal model could be detected and blamed to the abnormal ratio error. The simulation on the field data illustrates that the proposed method could identify the abnormal ratio error of CVTs of 0.2 accuracy class, and this method is suitable for the actual conditions in power system.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Monitoring the Ratio Error of High-Voltage CVTs Based on Local Outlier Identification
The capacitor voltage transformer (CVT) is one of the most important measurement equipment in the high-voltage (HV) power system, its metering accuracy is a key factor to ensure the safety of the power system and the fairness of the electricity trade. The conventional off-line calibration method to obtain the ratio error of CVTs is time-consuming and needs power cut, so it is no longer a suitable approach in the HV power system. In this paper, an on-line ratio error monitoring method for CVTs has been proposed, this method is based on local outlier identification. Considering the voltage fluctuations in the power system, the output voltages of CVTs are used to construct recognition models firstly, in which other fluctuation components have been eliminated except the ratio error, then the abnormal model could be detected and blamed to the abnormal ratio error. The simulation on the field data illustrates that the proposed method could identify the abnormal ratio error of CVTs of 0.2 accuracy class, and this method is suitable for the actual conditions in power system.
- 1 November 2019
- Published by Elsevier in Measurement
- Vol. 146, 770-779
Research on the reliability of capacitor voltage transformers calibration results
- 1 November 2019
- Published by Elsevier in Measurement
- Vol. 146, 770-779
Research on the reliability of capacitor voltage transformers calibration results
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Monitoring the Ratio Error Drift of CVTs Connected to the Same Phase along with KDE-PCA
The capacitor voltage transformer is now widely used in the high-voltage grid and its ratio error drift is one of the major fault developed from the maintenance experience. Thus, monitoring its ratio error drift efficiently attracts great interests. Conventional methods are time-consuming and need power cut, while some innovative data-driven methods are not so practical because of its rigorous precondition. Therefore, we propose a fuzzy modeling method for CVTs connected to the same phase along with the principal component analysis(PCA). Besides, the kernel density estimation(KDE) is also applied to improve its sensitivity. The KDE-PCA is more sensitive to the ratio error drift than the conventional PCA method as well as previous proposed methods through a field application in a 220kV thermal power plant.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Monitoring the Ratio Error Drift of CVTs Connected to the Same Phase along with KDE-PCA
The capacitor voltage transformer is now widely used in the high-voltage grid and its ratio error drift is one of the major fault developed from the maintenance experience. Thus, monitoring its ratio error drift efficiently attracts great interests. Conventional methods are time-consuming and need power cut, while some innovative data-driven methods are not so practical because of its rigorous precondition. Therefore, we propose a fuzzy modeling method for CVTs connected to the same phase along with the principal component analysis(PCA). Besides, the kernel density estimation(KDE) is also applied to improve its sensitivity. The KDE-PCA is more sensitive to the ratio error drift than the conventional PCA method as well as previous proposed methods through a field application in a 220kV thermal power plant.