Huan Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huan Peng has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Zhenli Zhu
State Key Laboratory of Geomicrobiology and Environmental Changes, China University of Geosciences, Wuhan, 430078, China.
5 shared publications - Juan Liu
Peking University
3 shared publications Alpha T. N'DIaye
2 shared publicationsCarolyn I. Pearce
2 shared publicationsDong He
State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, China
2 shared publicationsHongtao Zheng
Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, China
2 shared publications
Latest Publications
- 8 April 2024
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 373, 271-281
Effects of particle size and AQDS on the flow of electron equivalents between magnetite and aqueous Fe2+
- 8 April 2024
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 373, 271-281
Effects of particle size and AQDS on the flow of electron equivalents between magnetite and aqueous Fe2+
- 8 December 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (2) , 390-398
High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
In this study, we develop a method for high precision Cd isotope analysis by double spike MC-ICP-MS. Two-step Cd purification using AG-MP-1M resin and TRU resin was used to separate Cd from samples with a recovery of more than 95% Cd and a blank less than 0.1 ng. A practical double spike design and optimization procedure is proposed and the effect of the double spike ratio in the double spike-sample mixture (p) on the measured δ114/110Cd is evaluated, which broadens the appropriate p range from 0.3–0.6 to 0.1–0.8. In addition, the observed shift/deviation of the measured δ114/110CdNIST 3108 value from zero-delta due to the change of experimental conditions is discussed on a theoretical basis and a correction approach is developed. Potential Mo and Zr based polyatomic ions have no significant effect on δ114/110Cd in typical geological samples, while isobaric ions such as Sn, Pd and In can seriously affect the accuracy of measurements even at low concentration. It is shown that the tolerances of isobaric interference can be improved to 0.1, 0.05 and 0.02 for Sn/Cd, Pd/Cd and In/Cd, respectively, after mass discrimination correction. The precision and accuracy of the proposed method were verified by analyzing mixtures of NIST 3108 and a secondary reference material BGEG-Cd of different composition. Long term monitoring of the measured NIST 3108 and BGEG-Cd showed repeatability for δ114/110Cd of 0.00 ± 0.04‰ and −1.00 ± 0.04‰ (2sd, n = 45), respectively. Finally, we measured Cd isotope compositions of several geological standard materials including soil sediments and manganese nodules, and the δ114/110Cd values of 0.01 ± 0.02‰ (GSD-5a), 0.04 ± 0.02‰ (GSD-7a), −0.06 ± 0.05‰ (GSD-10), −0.34 ± 0.06‰ (GSD-11), −0.10 ± 0.06‰ (GSD-12), 0.10 ± 0.04‰ (GSD-17), 0.05 ± 0.03‰ (GSD-21), and 0.10 ± 0.07‰ (GSD-23) were in good agreement with the reported values, and a δ114/110Cd value of −0.08 ± 0.04‰ (GSD-3a) was reported for the first time.
- 8 December 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (2) , 390-398
High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
In this study, we develop a method for high precision Cd isotope analysis by double spike MC-ICP-MS. Two-step Cd purification using AG-MP-1M resin and TRU resin was used to separate Cd from samples with a recovery of more than 95% Cd and a blank less than 0.1 ng. A practical double spike design and optimization procedure is proposed and the effect of the double spike ratio in the double spike-sample mixture (p) on the measured δ114/110Cd is evaluated, which broadens the appropriate p range from 0.3–0.6 to 0.1–0.8. In addition, the observed shift/deviation of the measured δ114/110CdNIST 3108 value from zero-delta due to the change of experimental conditions is discussed on a theoretical basis and a correction approach is developed. Potential Mo and Zr based polyatomic ions have no significant effect on δ114/110Cd in typical geological samples, while isobaric ions such as Sn, Pd and In can seriously affect the accuracy of measurements even at low concentration. It is shown that the tolerances of isobaric interference can be improved to 0.1, 0.05 and 0.02 for Sn/Cd, Pd/Cd and In/Cd, respectively, after mass discrimination correction. The precision and accuracy of the proposed method were verified by analyzing mixtures of NIST 3108 and a secondary reference material BGEG-Cd of different composition. Long term monitoring of the measured NIST 3108 and BGEG-Cd showed repeatability for δ114/110Cd of 0.00 ± 0.04‰ and −1.00 ± 0.04‰ (2sd, n = 45), respectively. Finally, we measured Cd isotope compositions of several geological standard materials including soil sediments and manganese nodules, and the δ114/110Cd values of 0.01 ± 0.02‰ (GSD-5a), 0.04 ± 0.02‰ (GSD-7a), −0.06 ± 0.05‰ (GSD-10), −0.34 ± 0.06‰ (GSD-11), −0.10 ± 0.06‰ (GSD-12), 0.10 ± 0.04‰ (GSD-17), 0.05 ± 0.03‰ (GSD-21), and 0.10 ± 0.07‰ (GSD-23) were in good agreement with the reported values, and a δ114/110Cd value of −0.08 ± 0.04‰ (GSD-3a) was reported for the first time.
- 1 August 2020
- Published by Elsevier in Science of The Total Environment
- Vol. 728, 138252
Effects of exogenous dissolved organic matter on the adsorption–desorption behaviors and bioavailabilities of Cd and Hg in a plant–soil system
- 1 August 2020
- Published by Elsevier in Science of The Total Environment
- Vol. 728, 138252
Effects of exogenous dissolved organic matter on the adsorption–desorption behaviors and bioavailabilities of Cd and Hg in a plant–soil system
- 23 January 2019
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 53 (4) , 1863-1873
Redistribution of Electron Equivalents between Magnetite and Aqueous Fe2+ Induced by a Model Quinone Compound AQDS
The complex interactions between magnetite and aqueous Fe2+ (Fe2+(aq)) pertain to many biogeochemical redox processes in anoxic subsurface environments. The effect of natural organic matter, abundant in these same environments, on Fe2+(aq)-magnetite interactions is an additional complex that remains poorly understood. We investigated the influence of a model quinone molecule anthraquinone-2,6-disulfonate (AQDS) on Fe2+(aq)-magnetite interactions by systematically studying equilibrium Fe2+(aq) concentrations, rates and extents of AQDS reduction, and structural versus surface-localized Fe(II)/Fe(III) ratios in magnetite under different controlled experimental conditions. The equilibrium concentration of Fe2+(aq) in Fe2+-amended magnetite suspensions with AQDS proportionally changes with solution pH or initial AQDS concentration, but independent of magnetite loadings through the solids concentrations that were studied here. The rates and extents of AQDS reduction by Fe2+-amended magnetite proportionally increased with solution pH, magnetite loading, and initial Fe2+(aq) concentration, which correlates with the corresponding change of reduction potentials for the Fe2+-magnetite system. AQDS reduction by surface-associated Fe(II) in the Fe2+- magnetite suspensions induces solid-state migration of electron equivalents from particle interiors to the near-surface region and the production of non-magnetic Fe(II)-containing species, which inhibits Fe2+(aq) incorporation or electron injection into magnetite structure. This study demonstrates the significant influence of quinones on reductive activity of the Fe2+-magnetite system.
- 23 January 2019
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 53 (4) , 1863-1873
Redistribution of Electron Equivalents between Magnetite and Aqueous Fe2+ Induced by a Model Quinone Compound AQDS
The complex interactions between magnetite and aqueous Fe2+ (Fe2+(aq)) pertain to many biogeochemical redox processes in anoxic subsurface environments. The effect of natural organic matter, abundant in these same environments, on Fe2+(aq)-magnetite interactions is an additional complex that remains poorly understood. We investigated the influence of a model quinone molecule anthraquinone-2,6-disulfonate (AQDS) on Fe2+(aq)-magnetite interactions by systematically studying equilibrium Fe2+(aq) concentrations, rates and extents of AQDS reduction, and structural versus surface-localized Fe(II)/Fe(III) ratios in magnetite under different controlled experimental conditions. The equilibrium concentration of Fe2+(aq) in Fe2+-amended magnetite suspensions with AQDS proportionally changes with solution pH or initial AQDS concentration, but independent of magnetite loadings through the solids concentrations that were studied here. The rates and extents of AQDS reduction by Fe2+-amended magnetite proportionally increased with solution pH, magnetite loading, and initial Fe2+(aq) concentration, which correlates with the corresponding change of reduction potentials for the Fe2+-magnetite system. AQDS reduction by surface-associated Fe(II) in the Fe2+- magnetite suspensions induces solid-state migration of electron equivalents from particle interiors to the near-surface region and the production of non-magnetic Fe(II)-containing species, which inhibits Fe2+(aq) incorporation or electron injection into magnetite structure. This study demonstrates the significant influence of quinones on reductive activity of the Fe2+-magnetite system.
- 5 June 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 5 (7) , 1545-1555
Reversible Fe(ii) uptake/release by magnetite nanoparticles
Magnetite commonly coexists with aqueous Fe2+ (Fe2+ (aq)) in anoxic subsurface environments. Complex interactions between magnetite and Fe2+ (aq) profoundly impact redox potential fluctuations in surrounding environment and biogeochemical cycles of important elements and contaminants. However, the ability of magnetite to act as a source/sink of electron equivalents through fluctuations in solution pH or the activity of Fe2+ (aq) remains poorly quantified. We systematically studied the interrelationships between equilibrium Fe2+ (aq) concentrations and structural versus surface-localized Fe(II)/Fe(III) ratios in magnetite using micro X-ray diffraction and synchrotron-based X-ray magnetic circular dichroism, respectively, under different controlled experimental conditions. Relative to pH 7, at pH 6 proton-promoted dissolution yields Fe2+ (aq) release from magnetite nanoparticles, coupled to a decrease in the structural Fe(II)/Fe(III) ratio by electron hopping along the octahedral sublattice from the particle interior to the surface. At pH 8, magnetite sorbs Fe2+ (aq), increasing both the structural and surface-localized Fe(II)/Fe(III) ratio. Amendments of Fe2+ (aq) inhibit acidic Fe2+ (aq) release and promote Fe2+ (aq) uptake at more basic conditions, whereas increasing magnetite loading facilitates Fe2+ (aq)–magnetite interaction at the same respective pH extremes. The reversible flow of Fe(II) across the magnetite–solution interface under different conditions implies that the redox reactivity of magnetite nanoparticles is quickly responsive to changes in environmental conditions, such as an increase in pH due to groundwater passing through carbonate-rich rocks, via a dynamic redistribution of electron equivalents between particle interiors and the solid/water interface.
- 5 June 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 5 (7) , 1545-1555
Reversible Fe(ii) uptake/release by magnetite nanoparticles
Magnetite commonly coexists with aqueous Fe2+ (Fe2+ (aq)) in anoxic subsurface environments. Complex interactions between magnetite and Fe2+ (aq) profoundly impact redox potential fluctuations in surrounding environment and biogeochemical cycles of important elements and contaminants. However, the ability of magnetite to act as a source/sink of electron equivalents through fluctuations in solution pH or the activity of Fe2+ (aq) remains poorly quantified. We systematically studied the interrelationships between equilibrium Fe2+ (aq) concentrations and structural versus surface-localized Fe(II)/Fe(III) ratios in magnetite using micro X-ray diffraction and synchrotron-based X-ray magnetic circular dichroism, respectively, under different controlled experimental conditions. Relative to pH 7, at pH 6 proton-promoted dissolution yields Fe2+ (aq) release from magnetite nanoparticles, coupled to a decrease in the structural Fe(II)/Fe(III) ratio by electron hopping along the octahedral sublattice from the particle interior to the surface. At pH 8, magnetite sorbs Fe2+ (aq), increasing both the structural and surface-localized Fe(II)/Fe(III) ratio. Amendments of Fe2+ (aq) inhibit acidic Fe2+ (aq) release and promote Fe2+ (aq) uptake at more basic conditions, whereas increasing magnetite loading facilitates Fe2+ (aq)–magnetite interaction at the same respective pH extremes. The reversible flow of Fe(II) across the magnetite–solution interface under different conditions implies that the redox reactivity of magnetite nanoparticles is quickly responsive to changes in environmental conditions, such as an increase in pH due to groundwater passing through carbonate-rich rocks, via a dynamic redistribution of electron equivalents between particle interiors and the solid/water interface.
- 28 February 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (6) , 3694-3701
Battery-Operated Atomic Emission Analyzer for Waterborne Arsenic Based on Atmospheric Pressure Glow Discharge Excitation Source
In this paper, a sensitive atomic emission spectrometer (AES) based on a new low power and low argon consumption (–1) miniature direct current (dc) atmospheric pressure glow discharge (APGD) plasma (3 mm × 5 mm) excitation source was developed for the determination of arsenic in water samples. In this method, arsenic in water was reduced to AsH3 by hydride generation (HG), which was then transported to the APGD source for excitation and detected by a compact CCD (charge-coupled device) microspectrometer. Different parameters affecting the APGD and the hydride generation reactions were investigated. The detection limit for arsenic with the proposed APGD-AES was 0.25 μg L–1, and the calibration curves were found to be linear up to 3 orders of magnitude. The proposed method was successfully applied to the determination of certified reference material (GBW08605), tap water, pond water, groundwater, and hot spring samples. Measurements from the APGD analyzer showed good agreement with the certified value/values obtained with well-established hydride generation atomic fluorescence spectrometry (HG-AFS). These results suggest that the developed robust, cost-effective, and fast analyzer can be used for field based arsenic determination and may provide an important tool for arsenic contamination and remediation programs.
- 28 February 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (6) , 3694-3701
Battery-Operated Atomic Emission Analyzer for Waterborne Arsenic Based on Atmospheric Pressure Glow Discharge Excitation Source
In this paper, a sensitive atomic emission spectrometer (AES) based on a new low power and low argon consumption (–1) miniature direct current (dc) atmospheric pressure glow discharge (APGD) plasma (3 mm × 5 mm) excitation source was developed for the determination of arsenic in water samples. In this method, arsenic in water was reduced to AsH3 by hydride generation (HG), which was then transported to the APGD source for excitation and detected by a compact CCD (charge-coupled device) microspectrometer. Different parameters affecting the APGD and the hydride generation reactions were investigated. The detection limit for arsenic with the proposed APGD-AES was 0.25 μg L–1, and the calibration curves were found to be linear up to 3 orders of magnitude. The proposed method was successfully applied to the determination of certified reference material (GBW08605), tap water, pond water, groundwater, and hot spring samples. Measurements from the APGD analyzer showed good agreement with the certified value/values obtained with well-established hydride generation atomic fluorescence spectrometry (HG-AFS). These results suggest that the developed robust, cost-effective, and fast analyzer can be used for field based arsenic determination and may provide an important tool for arsenic contamination and remediation programs.
- 29 May 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (29) , 7523-7531
Cold vapor generation of Zn based on dielectric barrier discharge induced plasma chemical process for the determination of water samples by atomic fluorescence spectrometry
A new plasma chemical vapor generation (plasma-CVG) method for Zn was developed by dielectric barrier discharge (DBD). The dissolved Zn ions was readily converted to volatile species by DBD plasma in the presence of hydrogen and then, the generated Zn vapor, Zn0, was detected by cold vapor atomic fluorescence spectrometry (AFS). It eliminated the use of unstable tetrahydroborate-reducing reagent and high-purity acids. The operating conditions for the DBD plasma-CVG system were optimized for the efficient vapor generation of Zn. In addition, possible interferences from coexisting ions on the plasma-CVG of Zn were also examined. No appreciable matrix interference was found from most of the examined ions at concentration of 1 mg L−1. However, severe depression of the Zn vapor generation efficiency was observed in the presence of ions at 10 mg L−1. Under the optimal conditions, the limit of detection (LOD) was calculated to be 0.2 μg L−1; good repeatability (relative standard deviation (RSD) = 2.6 %, n = 11) was obtained for a 20 Zn μg L−1 standard. The accuracy of the proposed method was validated though analysis of Zn in reference material of simulated natural water sample GSB07-1184-2000 and the determined result was in good agreement with the reference value. The proposed method has also been successfully applied to the determination of Zn in Changjiang River water, Wuhan East Lake water, and Wuhan tap water samples. It provides an alternative green vapor generation method for Zn. Figure
- 29 May 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (29) , 7523-7531
Cold vapor generation of Zn based on dielectric barrier discharge induced plasma chemical process for the determination of water samples by atomic fluorescence spectrometry
A new plasma chemical vapor generation (plasma-CVG) method for Zn was developed by dielectric barrier discharge (DBD). The dissolved Zn ions was readily converted to volatile species by DBD plasma in the presence of hydrogen and then, the generated Zn vapor, Zn0, was detected by cold vapor atomic fluorescence spectrometry (AFS). It eliminated the use of unstable tetrahydroborate-reducing reagent and high-purity acids. The operating conditions for the DBD plasma-CVG system were optimized for the efficient vapor generation of Zn. In addition, possible interferences from coexisting ions on the plasma-CVG of Zn were also examined. No appreciable matrix interference was found from most of the examined ions at concentration of 1 mg L−1. However, severe depression of the Zn vapor generation efficiency was observed in the presence of ions at 10 mg L−1. Under the optimal conditions, the limit of detection (LOD) was calculated to be 0.2 μg L−1; good repeatability (relative standard deviation (RSD) = 2.6 %, n = 11) was obtained for a 20 Zn μg L−1 standard. The accuracy of the proposed method was validated though analysis of Zn in reference material of simulated natural water sample GSB07-1184-2000 and the determined result was in good agreement with the reference value. The proposed method has also been successfully applied to the determination of Zn in Changjiang River water, Wuhan East Lake water, and Wuhan tap water samples. It provides an alternative green vapor generation method for Zn. Figure