Robert D. Tucker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert D. Tucker has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
Charles E. Platz
7 shared publicationsEugene V. Kramolowsky
6 shared publicationsStephen E. Silvis
6 shared publicationsChester E. Sievert
5 shared publicationsJoon B. Park
Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242
4 shared publicationsChristian Huidobro
Department of Urology, University of Chile, Santiago, Chile
3 shared publications
Latest Publications
- 19 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Human Perception of Moderate Strength Low Frequency Magnetic Fields
If humans cannot perceive even subliminally that they have been immersed in or removed from a 60 Hz. magnetic field of a few gauss strength, comparable with the maximal value to be found around domestic or ELF communication systems, then it becomes very improbable that these fields have deleterious effects. With whole body immersion in a large Helmholtz coil field, some few individuals demonstrate perception scores absolutely impossible by chance, but as they are tested with acoustically quiet sources and with. better and better isolation from auxiliary nonmagnetic clues, fewer and fewer individuals show significant perception and none develop the very high scores found for sensitive subjects in the open coil systems. With an acoustically sealed isolation cabinet now being tested, perception scores may approach negligibility.
- 19 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Human Perception of Moderate Strength Low Frequency Magnetic Fields
If humans cannot perceive even subliminally that they have been immersed in or removed from a 60 Hz. magnetic field of a few gauss strength, comparable with the maximal value to be found around domestic or ELF communication systems, then it becomes very improbable that these fields have deleterious effects. With whole body immersion in a large Helmholtz coil field, some few individuals demonstrate perception scores absolutely impossible by chance, but as they are tested with acoustically quiet sources and with. better and better isolation from auxiliary nonmagnetic clues, fewer and fewer individuals show significant perception and none develop the very high scores found for sensitive subjects in the open coil systems. With an acoustically sealed isolation cabinet now being tested, perception scores may approach negligibility.
- 29 April 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 30  (11) , 4776-4784
Quantifying inadvertent thermal bowel injury from the monopolar instrument
Background Insulation defects are observed in 3–39 % of laparoscopic instruments. Electrosurgical injuries due to insulation defects or capacitive coupling remain an issue in laparoscopic surgery with a prevalence of 0.6–5 per thousand cases. Shielded instruments with active electrode monitoring (AEM) have been postulated to prevent these injuries. The benefit of these instruments has not been quantified. Most bowel injuries are unrecognized intra-operatively. Injury is revealed only after the patient exhibits peritonitis symptoms and surgical intervention to repair the bowel is required. These injuries may result in devastating and costly complications or mortality. The extent of bowel injury possible with commonly used generator settings and associated energy output has never been histologically defined. Our objectives in this experimental study were: quantify and compare the energy released through insulation defects or capacitive coupling with standard unshielded monopolar versus shielded instruments with (AEM), determine energy required to cause a visible burn, and relate the histological burn depth to a given amount of energy. Methods Ex vivo porcine jejunum was used for tissue testing. An oscilloscope measured energy output from three common electrosurgical generators at recommended power settings with standard or AEM instruments with insulation defects and in capacitive coupling scenarios. Presence of a visible burn was noted, and depth of tissue damage for a given amount of energy was measured histologically. Results All samples that received ≥3.8 J of energy had visible burns. As little as 10 J caused full wall thickness burns. 3.8 J was exceeded at the 30- and 50-W power settings in every experimental scenario using standard monopolar instruments; AEM instruments never approached this much energy. Conclusions Serious burn injury results from small amounts of energy leaked from standard instruments. AEM instruments appeared protective and did not leak sufficient energy to cause burn injuries to the bowel.
- 29 April 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 30  (11) , 4776-4784
Quantifying inadvertent thermal bowel injury from the monopolar instrument
Background Insulation defects are observed in 3–39 % of laparoscopic instruments. Electrosurgical injuries due to insulation defects or capacitive coupling remain an issue in laparoscopic surgery with a prevalence of 0.6–5 per thousand cases. Shielded instruments with active electrode monitoring (AEM) have been postulated to prevent these injuries. The benefit of these instruments has not been quantified. Most bowel injuries are unrecognized intra-operatively. Injury is revealed only after the patient exhibits peritonitis symptoms and surgical intervention to repair the bowel is required. These injuries may result in devastating and costly complications or mortality. The extent of bowel injury possible with commonly used generator settings and associated energy output has never been histologically defined. Our objectives in this experimental study were: quantify and compare the energy released through insulation defects or capacitive coupling with standard unshielded monopolar versus shielded instruments with (AEM), determine energy required to cause a visible burn, and relate the histological burn depth to a given amount of energy. Methods Ex vivo porcine jejunum was used for tissue testing. An oscilloscope measured energy output from three common electrosurgical generators at recommended power settings with standard or AEM instruments with insulation defects and in capacitive coupling scenarios. Presence of a visible burn was noted, and depth of tissue damage for a given amount of energy was measured histologically. Results All samples that received ≥3.8 J of energy had visible burns. As little as 10 J caused full wall thickness burns. 3.8 J was exceeded at the 30- and 50-W power settings in every experimental scenario using standard monopolar instruments; AEM instruments never approached this much energy. Conclusions Serious burn injury results from small amounts of energy leaked from standard instruments. AEM instruments appeared protective and did not leak sufficient energy to cause burn injuries to the bowel.
- Open Access
- 8 August 2015
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 83  (1) , 271-273
Electrosurgery in gastrointestinal endoscopy: terminology matters
- 8 August 2015
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 83  (1) , 271-273
Open AccessElectrosurgery in gastrointestinal endoscopy: terminology matters
- 1 November 2012
- Vol. 11  (11) , 1288-94
Facial tightening with an advanced 4-MHz monopolar radiofrequency device.
Over the past 10 years, radiofrequency (RF) technology has been utilized for nonablative treatments for the treatment of rhytides and skin laxity. This manuscript reviews the scientific background of collagen synthesis in vivo and in response to RF energy as well as a clinical study of 17 patients receiving a series of facial treatments with a 4-MHz monopolar RF (Pellevé, Ellman International, Inc, Oceanside, NY). Clinical methods, results, and a review of the literature for RF aesthetic treatments of the face are presented. Seventeen patients were treated in one site with 6 total treatments scheduled as follows: 1 session was performed every 15 days for 2 consecutive sessions, 1 session every month for 2 consecutive sessions, and 1 session every 2 months for 2 consecutive sessions. Both the treating physician and the patients via live viewing and comparison with baseline photographs performed assessment of results. Results are reported as averages across the 17 patients. Two weeks after the first treatment, patients noted an overall average of 25% to 30% improvement. Just before the last or sixth treatment, there was an average of 50% improvement noted by the physician, with patients ranking an average self-improvement of 48%. The treating physician rated average improvement of 46% compared with baseline, whereas the patients ranked average improvement of 30% compared with baseline at 1 year after treatment was initiated (6 months after the final treatment). Patients find this treatment to be very well tolerated, with minimal to no discomfort and no downtime or significant side effects. The Pellevé 4-MHz monopolar RF device is effective, safe, and very well tolerated for treating laxity, texture, and wrinkles of the skin without complication or discomfort. Evidence in the literature supports the scientific mechanism of action of acute collagen modification and continued neocollagenesis observed with the system. In this cohort, patients maintain approximately 50% improvement on average at 6 months and a 30% to 50% improvement 1 year after beginning the treatments, 6 months after completion.
- 1 November 2012
- Vol. 11  (11) , 1288-94
Facial tightening with an advanced 4-MHz monopolar radiofrequency device.
Over the past 10 years, radiofrequency (RF) technology has been utilized for nonablative treatments for the treatment of rhytides and skin laxity. This manuscript reviews the scientific background of collagen synthesis in vivo and in response to RF energy as well as a clinical study of 17 patients receiving a series of facial treatments with a 4-MHz monopolar RF (Pellevé, Ellman International, Inc, Oceanside, NY). Clinical methods, results, and a review of the literature for RF aesthetic treatments of the face are presented. Seventeen patients were treated in one site with 6 total treatments scheduled as follows: 1 session was performed every 15 days for 2 consecutive sessions, 1 session every month for 2 consecutive sessions, and 1 session every 2 months for 2 consecutive sessions. Both the treating physician and the patients via live viewing and comparison with baseline photographs performed assessment of results. Results are reported as averages across the 17 patients. Two weeks after the first treatment, patients noted an overall average of 25% to 30% improvement. Just before the last or sixth treatment, there was an average of 50% improvement noted by the physician, with patients ranking an average self-improvement of 48%. The treating physician rated average improvement of 46% compared with baseline, whereas the patients ranked average improvement of 30% compared with baseline at 1 year after treatment was initiated (6 months after the final treatment). Patients find this treatment to be very well tolerated, with minimal to no discomfort and no downtime or significant side effects. The Pellevé 4-MHz monopolar RF device is effective, safe, and very well tolerated for treating laxity, texture, and wrinkles of the skin without complication or discomfort. Evidence in the literature supports the scientific mechanism of action of acute collagen modification and continued neocollagenesis observed with the system. In this cohort, patients maintain approximately 50% improvement on average at 6 months and a 30% to 50% improvement 1 year after beginning the treatments, 6 months after completion.
- Open Access
- 1 October 2012
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. 5, 89-96
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
Peer reviewed article authored by (Piskun G, Tucker R). Read article or submit your manuscript for publishing.
- 1 October 2012
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. 5, 89-96
Open AccessNew bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids
Peer reviewed article authored by (Piskun G, Tucker R). Read article or submit your manuscript for publishing.
- 21 April 2009
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 104  (6) , 1563-1574
Electrosurgery in Gastrointestinal Endoscopy: Principles to Practice
An electrosurgery generator unit is a critical piece of equipment in any therapeutic endoscopy setting. Electrosurgery generators produce high-frequency alternating electric current and differ from electrocautery units in that both cutting and coagulation effects can be achieved. This ability to cut and coagulate at the same time makes electrosurgery an ideal therapeutic tool for gastrointestinal endoscopy. Although education and familiarity with these devices are accepted as the primary avenue to the safest and most effective clinical outcomes, concise information linking the basic properties of electrosurgery directly to clinical practice is not widespread. The following are the aims of this article: (i) to relate the fundamental electrosurgical principles to commonly performed procedures such as snare polypectomy, hot biopsy, sphincterotomy, bipolar hemostasis, and argon plasma coagulation, and (ii) to provide practical suggestions for the use of these devices on the basis of an understanding of electrosurgical principles and the available clinical data.
- 21 April 2009
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 104  (6) , 1563-1574
Electrosurgery in Gastrointestinal Endoscopy: Principles to Practice
An electrosurgery generator unit is a critical piece of equipment in any therapeutic endoscopy setting. Electrosurgery generators produce high-frequency alternating electric current and differ from electrocautery units in that both cutting and coagulation effects can be achieved. This ability to cut and coagulate at the same time makes electrosurgery an ideal therapeutic tool for gastrointestinal endoscopy. Although education and familiarity with these devices are accepted as the primary avenue to the safest and most effective clinical outcomes, concise information linking the basic properties of electrosurgery directly to clinical practice is not widespread. The following are the aims of this article: (i) to relate the fundamental electrosurgical principles to commonly performed procedures such as snare polypectomy, hot biopsy, sphincterotomy, bipolar hemostasis, and argon plasma coagulation, and (ii) to provide practical suggestions for the use of these devices on the basis of an understanding of electrosurgical principles and the available clinical data.
- 1 March 2007
- Published by Wolters Kluwer Health in Gastroenterology Nursing
- Vol. 30  (2) , 129-130
Commentary on Clinical Applications of Argon Plasma Coagulation in Endoscopy
- 1 March 2007
- Published by Wolters Kluwer Health in Gastroenterology Nursing
- Vol. 30  (2) , 129-130
Commentary on Clinical Applications of Argon Plasma Coagulation in Endoscopy
- 1 September 2005
- Published by SAGE Publications in Journal of Endourology
- Vol. 19  (7) , 865-867
Ablation of Stage T 1 /T 2 Prostate Cancer with Permanent Interstitial Temperature Self-Regulating Rods
Purpose: To determine if stage T1/T2 prostate cancer can be treated safely and effectively with interstitial thermal ablation. Patients and Methods: Twenty patients with biopsy-confirmed prostate cancer were enrolled in the protocol. The average age was 71.0 years, and the pretreatment prostate specific antigen (PSA) concentration ranged from 2.5 to 10.7 ng/mL and the Gleason sum from 3 to 7. An array of small biocompatible magnetic alloy rods was placed in the patients percutaneously in a procedure analogous to the placement of brachytherapy seeds. Rods were placed end-to-end and no further than 1 cm apart; rods extended to the capsule and were placed at the capsule in the rectal grove. The rods are temperature self-regulating and heat to 70°C when placed in an alternating magnetic field. Each patient was treated in a coil system that supplies a uniform magnetic field throughout the patient's pelvis for a single 60-minute session. Urethral cooling and rectal temperature monitoring was performed. Serial PSA was followed, and biopsy was performed 1 year post-treatment. Results: Immediately after treatment, most PSA values increased dramatically but then fell to Conclusion: The data suggest that this technique is well tolerated and safe and may be useful in certain patients with T1/T2 prostate cancer.
- 1 September 2005
- Published by SAGE Publications in Journal of Endourology
- Vol. 19  (7) , 865-867
Ablation of Stage T 1 /T 2 Prostate Cancer with Permanent Interstitial Temperature Self-Regulating Rods
Purpose: To determine if stage T1/T2 prostate cancer can be treated safely and effectively with interstitial thermal ablation. Patients and Methods: Twenty patients with biopsy-confirmed prostate cancer were enrolled in the protocol. The average age was 71.0 years, and the pretreatment prostate specific antigen (PSA) concentration ranged from 2.5 to 10.7 ng/mL and the Gleason sum from 3 to 7. An array of small biocompatible magnetic alloy rods was placed in the patients percutaneously in a procedure analogous to the placement of brachytherapy seeds. Rods were placed end-to-end and no further than 1 cm apart; rods extended to the capsule and were placed at the capsule in the rectal grove. The rods are temperature self-regulating and heat to 70°C when placed in an alternating magnetic field. Each patient was treated in a coil system that supplies a uniform magnetic field throughout the patient's pelvis for a single 60-minute session. Urethral cooling and rectal temperature monitoring was performed. Serial PSA was followed, and biopsy was performed 1 year post-treatment. Results: Immediately after treatment, most PSA values increased dramatically but then fell to Conclusion: The data suggest that this technique is well tolerated and safe and may be useful in certain patients with T1/T2 prostate cancer.
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 908-910
Utilization of a microcomputer development system as a task dedicated laboratory computer
Microcomputer development systems, although intended for development of single board computers, make attractive task-dedicated laboratory research computers. Because of their developmental nature they are relatively easy to interface AD, DA and TTL serial and parallel I/O. Programs can be written in a wide variety of languages and most vendors offer sophisticated debugging tools. One should not, however, consider a development system as an end-use laboratory computer unless sufficient hardware and software support are available. Development systems are very flexible and may be employed in many different projects which can save considerable money in hardware costs. An example of development system utilization in electrosurgery studies is given.
- 24 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 908-910
Utilization of a microcomputer development system as a task dedicated laboratory computer
Microcomputer development systems, although intended for development of single board computers, make attractive task-dedicated laboratory research computers. Because of their developmental nature they are relatively easy to interface AD, DA and TTL serial and parallel I/O. Programs can be written in a wide variety of languages and most vendors offer sophisticated debugging tools. One should not, however, consider a development system as an end-use laboratory computer unless sufficient hardware and software support are available. Development systems are very flexible and may be employed in many different projects which can save considerable money in hardware costs. An example of development system utilization in electrosurgery studies is given.
- 1 October 2003
- Published by SAGE Publications in Journal of Endourology
- Vol. 17  (8) , 601-607
Use of Interstitial Temperature Self-Regulating Thermal Rods in the Treatment of Prostate Cancer
Several groups are investigating a new technique for thermal treatment of the prostate involving permanent implantation of small biocompatable rods in a procedure similar to brachytherapy. The rods are then heated by an extracorporeal alternating magnetic field. The rods are composed of an alloy of palladium and cobalt such that they are temperature self-regulating; the regulated temperature is set during manufacture. Clinically, rods with a regulating temperature in the hyperthermia range are being employed as an adjuvant to external-beam radiation. Rods with a regulation temperature in the thermal ablation range are being used in two patient groups: those with newly diagnosed stage T(1) or T(2) prostate cancer and those who have localized recurrent disease after external-beam radiation. Early data appear promising.
- 1 October 2003
- Published by SAGE Publications in Journal of Endourology
- Vol. 17  (8) , 601-607
Use of Interstitial Temperature Self-Regulating Thermal Rods in the Treatment of Prostate Cancer
Several groups are investigating a new technique for thermal treatment of the prostate involving permanent implantation of small biocompatable rods in a procedure similar to brachytherapy. The rods are then heated by an extracorporeal alternating magnetic field. The rods are composed of an alloy of palladium and cobalt such that they are temperature self-regulating; the regulated temperature is set during manufacture. Clinically, rods with a regulating temperature in the hyperthermia range are being employed as an adjuvant to external-beam radiation. Rods with a regulation temperature in the thermal ablation range are being used in two patient groups: those with newly diagnosed stage T(1) or T(2) prostate cancer and those who have localized recurrent disease after external-beam radiation. Early data appear promising.