Takahiro Koji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takahiro Koji has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kuniaki Ogasawara
Department of Neurosurgery, School of Medicine, Iwate Medical University, Yahaba, Japan
2 shared publications - Shunrou Fujiwara
From the Department of Neurosurgery (K.K., Y.A, K.F., M.K, T.K., K.Y., K.O.), the Centre for Division of Ultrahigh Field MRI, Institute for Biomedical Sciences (I.U., M.S), the Division of Molecular and Cellular Pharmacology, Department of Pathophysiology (S.F.), and the Cyclotron Research Center (K.T.), Iwate Medical University, Yahaba, Japan
2 shared publications - Atsushi Sugawara
Department of Neurosurgery, Iwate Medical University School of Medicine, Morioka, Iwate, Japan
1 shared publication - Kenji Yoshida
Department of Neurosurgery, Iwate Medical University School of Medicine
1 shared publication - Kohei Chida
Department of Neurosurgery, Iwate Medical University School of Medicine, Yahaba, Iwate, Japan
1 shared publication - Masakazu Kobayashi
Department of Neurosurgery, Iwate Medical University, Iwate, Japan; Division of Ultrahigh Field MRI, Institute for Biomedical Sciences, Iwate Medical University, Iwate, Japan
1 shared publication
Latest Publications
- Open Access
Comparison of Subjective and Objective Assessments on Improvement in Gait Function after Carotid Endarterectomy
The purpose of the present study was to determine whether objective gait test scores obtained using a tri-axial accelerometer can detect subjective improvement in gait as determined by the patient after carotid endarterectomy (CEA). Each patient undergoing CEA for ipsilateral internal carotid artery stenosis determined whether their gait was subjectively improved at six months after CEA when compared with preoperatively. Gait testing using a tri-axial accelerometer was also performed preoperatively and six months postoperatively. Twelve (15%) of 79 patients reported subjectively improved gait. Areas under the receiver operating characteristic curve for differences between pre- and postoperative test values in stride time, cadence, and ground floor reaction for detecting subjectively improved gait were 0.995 (95% confidence interval (CI), 0.945–1.000), 0.958 (95%CI, 0.887–0.990), and 0.851 (95%CI, 0.753–0.921), respectively. Cut-off points for value differences in detecting subjectively improved gait were identical to mean −1.7 standard deviation (SD) for stride time, mean +1.6 SD for cadence, and mean +0.4 SD for ground floor reaction of control values from normal subjects. Objective gait test scores obtained using the tri-axial accelerometer can detect subjective gait improvements after CEA. When determining significant postoperative improvements in gait using a tri-axial accelerometer, optimal cut-off points for each test value can be defined.
Open AccessComparison of Subjective and Objective Assessments on Improvement in Gait Function after Carotid Endarterectomy
The purpose of the present study was to determine whether objective gait test scores obtained using a tri-axial accelerometer can detect subjective improvement in gait as determined by the patient after carotid endarterectomy (CEA). Each patient undergoing CEA for ipsilateral internal carotid artery stenosis determined whether their gait was subjectively improved at six months after CEA when compared with preoperatively. Gait testing using a tri-axial accelerometer was also performed preoperatively and six months postoperatively. Twelve (15%) of 79 patients reported subjectively improved gait. Areas under the receiver operating characteristic curve for differences between pre- and postoperative test values in stride time, cadence, and ground floor reaction for detecting subjectively improved gait were 0.995 (95% confidence interval (CI), 0.945–1.000), 0.958 (95%CI, 0.887–0.990), and 0.851 (95%CI, 0.753–0.921), respectively. Cut-off points for value differences in detecting subjectively improved gait were identical to mean −1.7 standard deviation (SD) for stride time, mean +1.6 SD for cadence, and mean +0.4 SD for ground floor reaction of control values from normal subjects. Objective gait test scores obtained using the tri-axial accelerometer can detect subjective gait improvements after CEA. When determining significant postoperative improvements in gait using a tri-axial accelerometer, optimal cut-off points for each test value can be defined.
- Open Access
The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects
The aim of this study was to investigate whether variation in gait-related parameters among healthy participants could help detect gait abnormalities. In total, 36 participants (21 men, 15 women; mean age, 35.7 ± 9.9 years) performed a 10-m walk six times while wearing a tri-axial accelerometer fixed at the L3 level. A second walk was performed ≥1 month after the first (mean interval, 49.6 ± 7.6 days). From each 10-m data set, the following nine gait-related parameters were automatically calculated: assessment time, number of steps, stride time, cadence, ground force reaction, step time, coefficient of variation (CV) of step time, velocity, and step length. Six repeated measurement values were averaged for each gait parameter. In addition, for each gait parameter, the difference between the first and second assessments was statistically examined, and the intraclass correlation coefficient (ICC) was calculated with the level of significance set at p < 0.05. Only the CV of step time showed a significant difference between the first and second assessments (p = 0.0188). The CV of step time also showed the lowest ICC, at <0.50 (0.425), among all parameters. Test–retest results of gait assessment using a tri-axial accelerometer showed sufficient reproducibility in terms of the clinical evaluation of all parameters except the CV of step time.
Open AccessThe Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects
The aim of this study was to investigate whether variation in gait-related parameters among healthy participants could help detect gait abnormalities. In total, 36 participants (21 men, 15 women; mean age, 35.7 ± 9.9 years) performed a 10-m walk six times while wearing a tri-axial accelerometer fixed at the L3 level. A second walk was performed ≥1 month after the first (mean interval, 49.6 ± 7.6 days). From each 10-m data set, the following nine gait-related parameters were automatically calculated: assessment time, number of steps, stride time, cadence, ground force reaction, step time, coefficient of variation (CV) of step time, velocity, and step length. Six repeated measurement values were averaged for each gait parameter. In addition, for each gait parameter, the difference between the first and second assessments was statistically examined, and the intraclass correlation coefficient (ICC) was calculated with the level of significance set at p < 0.05. Only the CV of step time showed a significant difference between the first and second assessments (p = 0.0188). The CV of step time also showed the lowest ICC, at <0.50 (0.425), among all parameters. Test–retest results of gait assessment using a tri-axial accelerometer showed sufficient reproducibility in terms of the clinical evaluation of all parameters except the CV of step time.