Huan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huan Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yu Gao
Tianjin University
5 shared publications - Xiaochen Yuan
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
3 shared publications - Huicun Zhao
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
2 shared publications - Tao Han
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
2 shared publications Xiaochen Yuan
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
2 shared publicationsZiyi Li
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
2 shared publications
Latest Publications
- 24 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (7) , 2166-2175
Surface Charge Accumulation on a Real Size Epoxy Insulator With Bouncing Metal Particle Under DC Voltage
Free metal particle can affect surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) or gas-insulated switchgear (GIS), which results in reduction of surface flashover voltage thus threatening the safe operation of the power equipment. This article reports on the charge accumulation behavior on a real size epoxy insulator with bouncing metal particle under DC voltage. A coaxial electrode system was designed for the test under -30 kV, a metal particle-launching system was employed to inject the bouncing linear particle to the insulator surface. The charge distribution was measured by a Kelvin-type probe, and the influence of the particle on the charge accumulation was analyzed with the help of electric field simulation. The results showed that there were mainly two moving patterns of the bouncing particle: the charges were accumulated with speckle shape and the charged particle that hit the edge of electrode had more remarkable influence on the charge accumulation than other particles. It is suggested that the charge distribution feature is dependent upon the collision point and the trajectory of the bouncing particle.
- 24 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (7) , 2166-2175
Surface Charge Accumulation on a Real Size Epoxy Insulator With Bouncing Metal Particle Under DC Voltage
Free metal particle can affect surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) or gas-insulated switchgear (GIS), which results in reduction of surface flashover voltage thus threatening the safe operation of the power equipment. This article reports on the charge accumulation behavior on a real size epoxy insulator with bouncing metal particle under DC voltage. A coaxial electrode system was designed for the test under -30 kV, a metal particle-launching system was employed to inject the bouncing linear particle to the insulator surface. The charge distribution was measured by a Kelvin-type probe, and the influence of the particle on the charge accumulation was analyzed with the help of electric field simulation. The results showed that there were mainly two moving patterns of the bouncing particle: the charges were accumulated with speckle shape and the charged particle that hit the edge of electrode had more remarkable influence on the charge accumulation than other particles. It is suggested that the charge distribution feature is dependent upon the collision point and the trajectory of the bouncing particle.
- 23 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (5) , 1627-1635
Gaseous Ionization Dependence of Surface Charge Pattern on Epoxy Insulator With Complex Surface Profile Under DC Voltage
Surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) and gas-insulated switchgear (GIS) has been recognized as a crucial factor for electric field distortion that results in the reduction of surface flashover voltage. This article reports on the gaseous ionization dependence of the charge accumulation pattern on a real-size epoxy insulator with multiarc surface profile by using various gas atmospheres. A coaxial electrode system was designed to investigate the charging behavior under dc voltages of -10, -20, and -30 kV. The insulator and electrodes were placed in a metal-enclosed test chamber, which was filled with 0.1 MPa air or 0.4 MPa SF 6 /N 2 mixture to estimate the influence of the gas atmosphere on the charge accumulation behavior by a Kelvin-type probe. The accumulation mechanism and the electric field distortion induced by the charges were demonstrated based on numerical simulation. The results indicated that positive charges were accumulated in the shape of speckle on insulator surface in air, whereas both positive and negative charges were accumulated in SF 6 /N 2 mixture and positive charge speckles appeared in SF 6 /N 2 mixture only when the voltage raised up to -30 kV. It is considered that the charge accumulation behavior is determined by the competition result among the bulk, the gas and the surface conductions. As compared with the case in air, gaseous ionization in SF 6 /N 2 mixture is more difficult to occur, which leads to the obvious difference in the charge accumulation pattern.
- 23 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (5) , 1627-1635
Gaseous Ionization Dependence of Surface Charge Pattern on Epoxy Insulator With Complex Surface Profile Under DC Voltage
Surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) and gas-insulated switchgear (GIS) has been recognized as a crucial factor for electric field distortion that results in the reduction of surface flashover voltage. This article reports on the gaseous ionization dependence of the charge accumulation pattern on a real-size epoxy insulator with multiarc surface profile by using various gas atmospheres. A coaxial electrode system was designed to investigate the charging behavior under dc voltages of -10, -20, and -30 kV. The insulator and electrodes were placed in a metal-enclosed test chamber, which was filled with 0.1 MPa air or 0.4 MPa SF 6 /N 2 mixture to estimate the influence of the gas atmosphere on the charge accumulation behavior by a Kelvin-type probe. The accumulation mechanism and the electric field distortion induced by the charges were demonstrated based on numerical simulation. The results indicated that positive charges were accumulated in the shape of speckle on insulator surface in air, whereas both positive and negative charges were accumulated in SF 6 /N 2 mixture and positive charge speckles appeared in SF 6 /N 2 mixture only when the voltage raised up to -30 kV. It is considered that the charge accumulation behavior is determined by the competition result among the bulk, the gas and the surface conductions. As compared with the case in air, gaseous ionization in SF 6 /N 2 mixture is more difficult to occur, which leads to the obvious difference in the charge accumulation pattern.
- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 471-474
Surface Charge Accumulation on Epoxy Insulator with Complex Surface Profile under DC Voltage in SF6/N2 Mixture
Epoxy insulator has been widely employed in Gas Insulated transmission Line (GIL) and Gas Insulated Switchgear (G1S). Surface charge accumulation on the insulator has been considered as a key point that affects the flashover voltage. In this paper, the surface charge accumulation behavior on realsized insulator with a complex surface profile in 0.4 MPa ${S}{F}_{6}/{N}_{2}$ mixture has been studied. The insulator as well as the electrode system was installed inside a sealed test chamber and DC stress of -10, -20, -$30{k}{V}$ was applied between the electrodes so as to charge the insulator. The accumulation mechanism has been demonstrated based on numerical simulation. The results showed that the surface charge was mainly negative in ${S}{F}_{6}/{N}_{2}$ mixture. The charge speckles were mainly accumulated in the nonplanar region of insulator. The main reason for this phenomenon is the competition among bulk conduction, gas conduction and surface conduction.- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 471-474
Surface Charge Accumulation on Epoxy Insulator with Complex Surface Profile under DC Voltage in SF6/N2 Mixture
Epoxy insulator has been widely employed in Gas Insulated transmission Line (GIL) and Gas Insulated Switchgear (G1S). Surface charge accumulation on the insulator has been considered as a key point that affects the flashover voltage. In this paper, the surface charge accumulation behavior on realsized insulator with a complex surface profile in 0.4 MPa ${S}{F}_{6}/{N}_{2}$ mixture has been studied. The insulator as well as the electrode system was installed inside a sealed test chamber and DC stress of -10, -20, -$30{k}{V}$ was applied between the electrodes so as to charge the insulator. The accumulation mechanism has been demonstrated based on numerical simulation. The results showed that the surface charge was mainly negative in ${S}{F}_{6}/{N}_{2}$ mixture. The charge speckles were mainly accumulated in the nonplanar region of insulator. The main reason for this phenomenon is the competition among bulk conduction, gas conduction and surface conduction.- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 479-482
Effect of Vibration on Surface Charge Accumulation of Epoxy Insulator with the Presence of Metal Particles
This paper deals with the effect of vibration on surface charge accumulation behavior with the presence of metal particles at different initial positions under DC voltage of -30 kV. A vibration system with push/pull solenoid and control mechanism was designed to input vibration on the coaxial electrodes and the epoxy insulator. Surface potential on the insulator was measured by a Kelvin type probe and the inverse calculation was performed to obtain the charge density, by which the influence of vibration could be examined. The results indicated that positive charges were accumulated in shape of speckle on insulator surface. The location of charge s peckle and the maximum charge density are determined by the polarity and the position of metal particle after vibration. It is considered that with the presence of metal particles, vibration would encourage surface charge accmulation by causing the movement of the particle.
- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 479-482
Effect of Vibration on Surface Charge Accumulation of Epoxy Insulator with the Presence of Metal Particles
This paper deals with the effect of vibration on surface charge accumulation behavior with the presence of metal particles at different initial positions under DC voltage of -30 kV. A vibration system with push/pull solenoid and control mechanism was designed to input vibration on the coaxial electrodes and the epoxy insulator. Surface potential on the insulator was measured by a Kelvin type probe and the inverse calculation was performed to obtain the charge density, by which the influence of vibration could be examined. The results indicated that positive charges were accumulated in shape of speckle on insulator surface. The location of charge s peckle and the maximum charge density are determined by the polarity and the position of metal particle after vibration. It is considered that with the presence of metal particles, vibration would encourage surface charge accmulation by causing the movement of the particle.
- Open Access
- 18 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 11165-11173
Graphene Oxide Addition With Low Fraction Improving Surface Charge Inhibition Performance of Epoxy/SiC Coating Under DC Stress
Surface charge accumulation under DC stress is a critical factor in reducing the insulation performance of epoxy-based nanocomposite. Surface coating has been used to inhibit the charge accumulation, but the inhibition mechanism of the coating material is still unclear. In this paper, graphene oxide (GO) and silicon carbide (SiC) have been selected as fillers to prepare the coating material with epoxy as the base material. The role of GO on surface charge inhibition performance of epoxy/SiC coating has been estimated. The test results showed that the charge inhibition performance increased with the growth of nano-SiC content from 1 wt% to 5 wt% in the epoxy/SiC coating. As regards the epoxy/(SiC+GO) coating, the charge inhibition performance reduced as the SiC content increased. It is suggested that the charge inhibition performance of epoxy/SiC coating can be improved with a low content addition of GO. The variation of trap distribution in the coating material caused by the GO should be responsible for the enhanced charge inhibition behavior.
- 18 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 11165-11173
Open AccessGraphene Oxide Addition With Low Fraction Improving Surface Charge Inhibition Performance of Epoxy/SiC Coating Under DC Stress
Surface charge accumulation under DC stress is a critical factor in reducing the insulation performance of epoxy-based nanocomposite. Surface coating has been used to inhibit the charge accumulation, but the inhibition mechanism of the coating material is still unclear. In this paper, graphene oxide (GO) and silicon carbide (SiC) have been selected as fillers to prepare the coating material with epoxy as the base material. The role of GO on surface charge inhibition performance of epoxy/SiC coating has been estimated. The test results showed that the charge inhibition performance increased with the growth of nano-SiC content from 1 wt% to 5 wt% in the epoxy/SiC coating. As regards the epoxy/(SiC+GO) coating, the charge inhibition performance reduced as the SiC content increased. It is suggested that the charge inhibition performance of epoxy/SiC coating can be improved with a low content addition of GO. The variation of trap distribution in the coating material caused by the GO should be responsible for the enhanced charge inhibition behavior.