HZHuicun Zhao

Huicun Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huicun Zhao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Surface Charge Accumulation of Zoning-Coating GIS Insulator in Different Gas Atmospheres

    by Yu Gao, Di Lu, Wenqu Wang, Huicun Zhao, Tao Han, Boxue Du

    Zoning-coating that deposits various functional coating materials on different surface regions of insulators installed in gas-insulated switchgear (GIS) has been recognized as a promising method to suppress surface charge accumulation. This article reports on the surface charge accumulation on the zoning-coating insulator in various gas atmospheres. A downsized disk insulator and a coaxial electrode system are designed to investigate the charge behavior under dc voltage of $-$ 10, $-$ 20, and $-$ 30 kV. The insulator is placed in the enclosed chamber, which is filled with 0.1, 0.2 and 0.3 mPa SF $_{6}$ /N $_{2}$ and C $_{4}$ F $_{7}$ N/CO $_{2}$ mixture. After being charged by HVDC, the surface charge is measured by a kelvin-type probe, and the accumulation mechanism as well as the regularity of charge distribution are demonstrated. The results indicate that homo-charges are accumulated on the nonplanar region and hetero-charges are mainly accumulated on the planar region of the insulator in the mixtures. With the increase of the applied voltage, the charge density rises and it is higher in C $_{4}$ F $_{7}$ N/CO $_{2}$ mixture than in SF $_{6}$ /N $_{2}$ mixture. The surface charge density decreases with the increase of gas pressure, and the charge density in C $_{4}$ F $_{7}$ N/CO $_{2}$ mixture is slightly higher than that in SF $_{6}$ /N $_{2}$ mixture. The surface charge distribution in C $_{4}$ F $_{7}$ N/CO $_{2}$ mixture is more irregular than in SF $_{6}$ /N $_{2}$ mixture, and the regularity increases with the rise of gas pressure and decreases with the rise of applied voltage.


  • Open Access

    The Effect of a Metal Particle on Surface Charge Accumulation Behavior of Epoxy Insulator with Zoning Coating

    by Wenqu Wang, Yu Gao, Huicun Zhao

    Epoxy insulators are widely used in Gas-Insulated Transmission Lines (GILs), playing a significant role in electrical insulation and mechanical support. The metal particles generated during the production and operation of the equipment aggravate surface charge accumulation on the insulator, causing surface flashover. Therefore, it is necessary to study the suppression strategy of charge accumulation. In this paper, a downsized disc insulator was taken as the research object to investigate the effect of zoning coating on charge suppression with the presence of a linear aluminum metal particle under negative DC voltage. The zoning coating method was achieved by painting coatings with different conductivities in three areas on the insulator surface to regulate the charge. The inhibition mechanism of zoning coating on the charge accumulation in the presence of a linear metal particle was analyzed with the assistance of numerical simulation. The results showed that negative charges were accumulated in the nonplanar region as there was no metal particle, and the existence of metal particles led to the significant accumulation of positive charge speckles in the nonplanar region. The application of zoning coating could significantly inhibit the charge accumulation in the nonplanar area of the insulator and the charge injection from the grounded electrode to reduce the charge density. Under −25 kV, the maximum charge density on the insulator with the zoning coating was 48.1% lower than that without the coating, and the inhibition effect increased by 57.9% when the metal particle was introduced. This paper provides a new way to suppress the charge accumulation on the insulator surface.


  • Open Access

    Numerical Simulation on Charge Transport and DC Breakdown in Polyethylene-Based Micro-h-BN/Nano-SiO2 with Filler Orientation Dependent Trap Energy

    by Xuri Xu, Yu Gao, Jing Li, Zheng Song, Huicun Zhao, Tao Han

    In order to improve the thermal conductivity and the insulation properties of polyethylene (PE) used as cable insulation under DC stress, hexagonal boron nitride (h-BN) and inorganic particles have been considered as micro-filler and nano-filler, respectively. As a 2D material, the orientation of h-BN possibly affects the insulation properties of the polymer. It is important to understand the influence of the filler orientation on the insulation performance of the polymer. In this work, a numerical simulation has been performed to investigate the effect of orientation of micro-h-BN on charge transport and DC breakdown of PE-based micro/nano-composites and a comparison between the simulation result and previous literature data has been conducted. The h-BN was designated to be parallel, perpendicular to the normal sample surface vector (the direction of electric field in this work) or randomly distributed in the matrix, and the charge transport behavior and DC breakdown strength in the samples were discussed by using the bipolar charge transport (BCT) model. The results indicated that when the h-BN was perpendicular to the normal vector, the density of trapped charge was the largest and the DC breakdown strength was the highest among the three cases studied. It is suggested that the charge trapping/de-trapping processes and the electric field in the sample vary with the orientation of h-BN through tailoring the trap characteristics of the material.


  • Surface Charge Accumulation on a Real Size Epoxy Insulator With Bouncing Metal Particle Under DC Voltage

    by Yu Gao, Huan Wang, Xiaochen Yuan, Huicun Zhao, Ziyi Li

    Free metal particle can affect surface charge accumulation on epoxy insulator installed in gas-insulated transmission line (GIL) or gas-insulated switchgear (GIS), which results in reduction of surface flashover voltage thus threatening the safe operation of the power equipment. This article reports on the charge accumulation behavior on a real size epoxy insulator with bouncing metal particle under DC voltage. A coaxial electrode system was designed for the test under -30 kV, a metal particle-launching system was employed to inject the bouncing linear particle to the insulator surface. The charge distribution was measured by a Kelvin-type probe, and the influence of the particle on the charge accumulation was analyzed with the help of electric field simulation. The results showed that there were mainly two moving patterns of the bouncing particle: the charges were accumulated with speckle shape and the charged particle that hit the edge of electrode had more remarkable influence on the charge accumulation than other particles. It is suggested that the charge distribution feature is dependent upon the collision point and the trajectory of the bouncing particle.


  • Surface Charge Accumulation on Epoxy Insulator with Complex Surface Profile under DC Voltage in SF6/N2 Mixture

    by Huicun Zhao, Yu Gao, Xiaobo Song, Chi Zhang, Xiaochen Yuan, Huan Wang

    Epoxy insulator has been widely employed in Gas Insulated transmission Line (GIL) and Gas Insulated Switchgear (G1S). Surface charge accumulation on the insulator has been considered as a key point that affects the flashover voltage. In this paper, the surface charge accumulation behavior on realsized insulator with a complex surface profile in 0.4 MPa ${S}{F}_{6}/{N}_{2}$ mixture has been studied. The insulator as well as the electrode system was installed inside a sealed test chamber and DC stress of -10, -20, -$30{k}{V}$ was applied between the electrodes so as to charge the insulator. The accumulation mechanism has been demonstrated based on numerical simulation. The results showed that the surface charge was mainly negative in ${S}{F}_{6}/{N}_{2}$ mixture. The charge speckles were mainly accumulated in the nonplanar region of insulator. The main reason for this phenomenon is the competition among bulk conduction, gas conduction and surface conduction.