Siba Kumar Patro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Siba Kumar Patro has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Anshuman Shukla
Department of Electrical Engineering, Indian Institute of Technology Bombay, Mumbai, India
11 shared publications - Ibhan Chand Rath
IIT Bombay, Research Park, Igrenenergi Services Private Limited, Mumbai, India
3 shared publications Akhil Manoj Shende
Visvesvaraya National Institute of Technology,Electrical Engineering Department,Nagpur,India
2 shared publicationsAnshuman Shukla
Indian Institute of Technology Bombay,Electrical Engineering Department,Mumbai,India
2 shared publicationsIbhan Chand Rath
2 shared publications- Madhuri Avinash Chaudhari
Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India
2 shared publications
Latest Publications
- 24 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Parallel Arm Hybrid Bridge Converter to Augment Power Handling Capability in HVDC Applications
The challenges associated with the limitations of existing MMC topologies have been addressed time and again. A novel topology is proposed to deal with high power handling capability. The paper showcases operative idea of a new hybrid converter that binds IGBTs and submodules for acquiring large power handling while maintaining lower footprint. The topology named 'Parallel Arm Hybrid Bridge Converter' (PAHBC) is undoubtedly superior to the hitherto published tracks with supplementary privilege of reduced capacitor size all while harnessing lower cost. PAHBC has three chain links in each phase and their parallel usage divides the current among chain links. This division reduces energy storage requirement leading to lower footprint. Moreover, parallel arms increase the overall power handling capability and reliability. The modulation technique for the converter is also detailed along with comparative evaluation with other MMC derived topologies. The DC fault tolerance is investigated and results validate the converter performance. The topology can also operate over wide range of modulation index and its detailed analysis is shown. The comparison table along with the loss analysis further indicates that the proposed converter is a promising design choice. The excellent prosecution of the topology and its mechanics are confirmed through simulations in PSCAD/ EMTDC and experimental lab setup.
- 24 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Parallel Arm Hybrid Bridge Converter to Augment Power Handling Capability in HVDC Applications
The challenges associated with the limitations of existing MMC topologies have been addressed time and again. A novel topology is proposed to deal with high power handling capability. The paper showcases operative idea of a new hybrid converter that binds IGBTs and submodules for acquiring large power handling while maintaining lower footprint. The topology named 'Parallel Arm Hybrid Bridge Converter' (PAHBC) is undoubtedly superior to the hitherto published tracks with supplementary privilege of reduced capacitor size all while harnessing lower cost. PAHBC has three chain links in each phase and their parallel usage divides the current among chain links. This division reduces energy storage requirement leading to lower footprint. Moreover, parallel arms increase the overall power handling capability and reliability. The modulation technique for the converter is also detailed along with comparative evaluation with other MMC derived topologies. The DC fault tolerance is investigated and results validate the converter performance. The topology can also operate over wide range of modulation index and its detailed analysis is shown. The comparison table along with the loss analysis further indicates that the proposed converter is a promising design choice. The excellent prosecution of the topology and its mechanics are confirmed through simulations in PSCAD/ EMTDC and experimental lab setup.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3244-3262
Transformer-Less Hybrid Series Static Compensator and its DC Capacitor Voltage Balance Technique Using Zero-Sequence Voltage
The hybrid-series-converter-(HSC) has enhanced operating modulation-index-(MI) range compared to parallel-hybrid-converter-(PHC). However, the HSC is under-utilized when employed for applications such as HVDC. The parallel-chain-links-(PCLs) of HSC generate rectified voltage of fixed amplitude whereas the series-chain-links-(SCLs) serve as voltage wave-shaping circuit. The maximum output voltage of HSC is equal to PCL rating. Moreover, HSC (and also PHC) demands three single-phase transformers for their operation and consists of series/director-switches-(DSs) that undergo high voltage and dv/dt stress. This paper intends to extract all the advantages inherent with HSC and utilize it to its maximum ability by restructuring and operating as transformer-less hybrid-series static-compensator-(THSSC). The SCLs of THSSC act as voltage-aiding circuit and reduces voltage stress across DSs. In addition, THSSC has lower energy-storage requirement and require fewer sub-module capacitors and switching devices. During unbalanced grid conditions, capacitor voltages related to different phases of THSSC tend to divert from reference. The required quantity of zero-sequence voltage-(ZSV) is injected into the PCL and SCL of all three phases to govern capacitor voltages. The expression for reference ZSV is derived by using feed-back and feed-forward method. The converter working principle and capacitor voltage control technique are authenticated using experimental results obtained under different grid voltage conditions.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3244-3262
Transformer-Less Hybrid Series Static Compensator and its DC Capacitor Voltage Balance Technique Using Zero-Sequence Voltage
The hybrid-series-converter-(HSC) has enhanced operating modulation-index-(MI) range compared to parallel-hybrid-converter-(PHC). However, the HSC is under-utilized when employed for applications such as HVDC. The parallel-chain-links-(PCLs) of HSC generate rectified voltage of fixed amplitude whereas the series-chain-links-(SCLs) serve as voltage wave-shaping circuit. The maximum output voltage of HSC is equal to PCL rating. Moreover, HSC (and also PHC) demands three single-phase transformers for their operation and consists of series/director-switches-(DSs) that undergo high voltage and dv/dt stress. This paper intends to extract all the advantages inherent with HSC and utilize it to its maximum ability by restructuring and operating as transformer-less hybrid-series static-compensator-(THSSC). The SCLs of THSSC act as voltage-aiding circuit and reduces voltage stress across DSs. In addition, THSSC has lower energy-storage requirement and require fewer sub-module capacitors and switching devices. During unbalanced grid conditions, capacitor voltages related to different phases of THSSC tend to divert from reference. The required quantity of zero-sequence voltage-(ZSV) is injected into the PCL and SCL of all three phases to govern capacitor voltages. The expression for reference ZSV is derived by using feed-back and feed-forward method. The converter working principle and capacitor voltage control technique are authenticated using experimental results obtained under different grid voltage conditions.
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 1077-1089
High Power Parallel Hybrid DC-DC Converter
The parallel hybrid converter (PHC) is gaining popularity for high voltage direct current (HVdc) applications. The PHC features low energy storage requirement and low conduction losses in the sub-modules (SMs). Moreover, the PHC requires lower number of SMs and switching devices. However, the existing PHC configuration needs harmonic voltage injection in the chain-links (CLs) to feed the ac grid, thereby injecting harmonic currents into the main DC-link. Additionally, the existing PHC lacks dc fault-tolerant capability. A new front–to-front dc-dc configuration called as parallel hybrid dc-dc converter (PHDC) for HVdc application is presented. The proposed PHDC eliminates the need of harmonic voltage injection and provides the dc fault-tolerant capability. Furthermore, the proposed PHDC requires lesser energy storage and smaller interlinking transformers than in the PHC used for ac-dc application. The detailed mathematical analysis with design procedure considering the dc-dc conversion application is presented. The authenticity of the proposed dc-dc converter is verified by both analytical and simulation studies. Finally, a three phase front-to-front experimental setup is tested for different operating conditions and results are presented
- 25 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 1077-1089
High Power Parallel Hybrid DC-DC Converter
The parallel hybrid converter (PHC) is gaining popularity for high voltage direct current (HVdc) applications. The PHC features low energy storage requirement and low conduction losses in the sub-modules (SMs). Moreover, the PHC requires lower number of SMs and switching devices. However, the existing PHC configuration needs harmonic voltage injection in the chain-links (CLs) to feed the ac grid, thereby injecting harmonic currents into the main DC-link. Additionally, the existing PHC lacks dc fault-tolerant capability. A new front–to-front dc-dc configuration called as parallel hybrid dc-dc converter (PHDC) for HVdc application is presented. The proposed PHDC eliminates the need of harmonic voltage injection and provides the dc fault-tolerant capability. Furthermore, the proposed PHDC requires lesser energy storage and smaller interlinking transformers than in the PHC used for ac-dc application. The detailed mathematical analysis with design procedure considering the dc-dc conversion application is presented. The authenticity of the proposed dc-dc converter is verified by both analytical and simulation studies. Finally, a three phase front-to-front experimental setup is tested for different operating conditions and results are presented
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (10) , 12134-12150
Parallel-Hybrid Converter Based STATCOM: Operating Principles and Capacitor Voltage Control Using Fundamental Frequency Zero-Sequence Voltage
The parallel-hybrid converter (PHC) based high-voltage dc (HVdc) plant (PHC-HVdc) mandates the injection of additional harmonic-voltage components into its chain-links (CLs) to regulate its output voltage/modulation index (MI). However, these harmonic voltages are restricted to have limited magnitude and their zero crossings must coincide with the respective output voltages of converter. Hence, the operating range of MI for the PHC-HVdc has narrow limits. This article explores the reactive power compensating capabilities of the PHC based static compensator (PHC-STATCOM), which is relieved from the fixed dc source and is free to operate at any MI without requiring any additional efforts. Two degrees of freedom inherent with PHC-STATCOM are discovered, which proves that PHC is utilized to its maximum when applied for reactive compensation. The capacitor voltages of the PHC-STATCOM belonging to different CLs divert from desired value under unbalanced grid/load conditions. By the virtue of degrees of freedom associated with PHC-STATCOM, a capacitor voltage control technique is proposed using fundamental-frequency zero-sequence voltage (FFZSV). The generalized expression of the reference FFZSV is derived, which regulates the capacitor voltages. The loci planes indicating the maximum range of load unbalance that the PHC-STATCOM can compensate with specific grid voltage conditions is obtained and plotted. The working principles and proposed capacitor control are verified using experimental studies. A detailed comparative study is presented to substantiate the advantages of the proposed topology.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (10) , 12134-12150
Parallel-Hybrid Converter Based STATCOM: Operating Principles and Capacitor Voltage Control Using Fundamental Frequency Zero-Sequence Voltage
The parallel-hybrid converter (PHC) based high-voltage dc (HVdc) plant (PHC-HVdc) mandates the injection of additional harmonic-voltage components into its chain-links (CLs) to regulate its output voltage/modulation index (MI). However, these harmonic voltages are restricted to have limited magnitude and their zero crossings must coincide with the respective output voltages of converter. Hence, the operating range of MI for the PHC-HVdc has narrow limits. This article explores the reactive power compensating capabilities of the PHC based static compensator (PHC-STATCOM), which is relieved from the fixed dc source and is free to operate at any MI without requiring any additional efforts. Two degrees of freedom inherent with PHC-STATCOM are discovered, which proves that PHC is utilized to its maximum when applied for reactive compensation. The capacitor voltages of the PHC-STATCOM belonging to different CLs divert from desired value under unbalanced grid/load conditions. By the virtue of degrees of freedom associated with PHC-STATCOM, a capacitor voltage control technique is proposed using fundamental-frequency zero-sequence voltage (FFZSV). The generalized expression of the reference FFZSV is derived, which regulates the capacitor voltages. The loci planes indicating the maximum range of load unbalance that the PHC-STATCOM can compensate with specific grid voltage conditions is obtained and plotted. The working principles and proposed capacitor control are verified using experimental studies. A detailed comparative study is presented to substantiate the advantages of the proposed topology.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Tolerant Si-SiC based Hybrid Modular Multilevel Converter with Enhanced Efficiency
Conventional Modular Multilevel Converter (MMC) consisting of only Half-Bridge Sub Module (HB-SM) offers scalability, modularity, flexibility, and lower losses as compared to multilevel converters. However, it lacks to provide DC fault-tolerant capability in High Voltage Direct Current (HVDC) applications. This paper proposes a Silicon-Silicon Carbide (Si-SiC) based Hybrid MMC, called as Fault Tolerant MMC (FTMMC), consisting of SiC based HB-SM and Si based Full-Bridge Sub Module (FB-SM), that provides DC fault-tolerant capability with enhanced efficiency for HVDC applications. In this paper, a control technique is used, resulting in FB-SM switching at the fundamental frequency and HB-SM switching at a significantly higher switching frequency. The FB-SM is controlled using the Nearest Level Control (NLC) modulation approach, while the HB-SM is controlled using a combination of NLC method and Phase Disposition Pulse Width Modulation (PDPWM) technique. Since the switching frequency of the HB-SM is significantly higher than the FB-SM, SiC switches are used in HB-SM to minimize the switching losses and to optimize the cost of the system. This is because SiC switches have lower switching losses and higher cost than Si switches. Furthermore, for voltage balancing of the FB-SM and the HB-SM, the Reduced Switching Frequency (RSF) technique is used, which decreases the switching frequency of each SM and therefore minimizes the overall switching loss of the FTMMC. To evaluate the effectiveness of the proposed converter topology and its control technique, simulation of the FTMMC is performed in MATLAB Simulink. The power loss of FTMMC is analytically calculated and compared with the existing solutions to prove its efficiency.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Fault Tolerant Si-SiC based Hybrid Modular Multilevel Converter with Enhanced Efficiency
Conventional Modular Multilevel Converter (MMC) consisting of only Half-Bridge Sub Module (HB-SM) offers scalability, modularity, flexibility, and lower losses as compared to multilevel converters. However, it lacks to provide DC fault-tolerant capability in High Voltage Direct Current (HVDC) applications. This paper proposes a Silicon-Silicon Carbide (Si-SiC) based Hybrid MMC, called as Fault Tolerant MMC (FTMMC), consisting of SiC based HB-SM and Si based Full-Bridge Sub Module (FB-SM), that provides DC fault-tolerant capability with enhanced efficiency for HVDC applications. In this paper, a control technique is used, resulting in FB-SM switching at the fundamental frequency and HB-SM switching at a significantly higher switching frequency. The FB-SM is controlled using the Nearest Level Control (NLC) modulation approach, while the HB-SM is controlled using a combination of NLC method and Phase Disposition Pulse Width Modulation (PDPWM) technique. Since the switching frequency of the HB-SM is significantly higher than the FB-SM, SiC switches are used in HB-SM to minimize the switching losses and to optimize the cost of the system. This is because SiC switches have lower switching losses and higher cost than Si switches. Furthermore, for voltage balancing of the FB-SM and the HB-SM, the Reduced Switching Frequency (RSF) technique is used, which decreases the switching frequency of each SM and therefore minimizes the overall switching loss of the FTMMC. To evaluate the effectiveness of the proposed converter topology and its control technique, simulation of the FTMMC is performed in MATLAB Simulink. The power loss of FTMMC is analytically calculated and compared with the existing solutions to prove its efficiency.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Hybrid Modular Multilevel Converter based on Si and SiC Devices with Level Multiplier Circuit
This paper presents a Modular Multilevel Converter (MMC) variant that can obtain greater number of output voltage levels than the conventional MMC while using smaller number of Submodule (SM). It is called as Level Multiplier Circuit for MMC (LMMMC). It is a Hybrid MMC made up of Half-bridge Submodule (HB-SM) and Full-bridge Submodule (FB-SM). In comparison to the HB-SM cell, the FB-SM cell has a different voltage value. The number of FB-SMs connected in the arm determines the value of each FB-SM voltage. To achieve the same number of levels in the output voltage, LMMMC employs fewer semiconductor switches than the conventional MMC. The switching loss of the LMMMC increases because the switching frequency of FB-SM is significantly higher than the HB-SM. To compensate for this, Silicon Carbide (SiC) switches are utilized instead of Silicon (Si) switches in the FB-SM. This is due to the fact that SiC devices have lower switching losses than Si devices. The operational principle of LMMMC is described, as well as comparison of its power loss to that of a conventional MMC is presented. The conventional MMC and LMMMC models are simulated in MATLAB Simulink to verify the effectiveness of the proposed converter topology.
- 19 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Hybrid Modular Multilevel Converter based on Si and SiC Devices with Level Multiplier Circuit
This paper presents a Modular Multilevel Converter (MMC) variant that can obtain greater number of output voltage levels than the conventional MMC while using smaller number of Submodule (SM). It is called as Level Multiplier Circuit for MMC (LMMMC). It is a Hybrid MMC made up of Half-bridge Submodule (HB-SM) and Full-bridge Submodule (FB-SM). In comparison to the HB-SM cell, the FB-SM cell has a different voltage value. The number of FB-SMs connected in the arm determines the value of each FB-SM voltage. To achieve the same number of levels in the output voltage, LMMMC employs fewer semiconductor switches than the conventional MMC. The switching loss of the LMMMC increases because the switching frequency of FB-SM is significantly higher than the HB-SM. To compensate for this, Silicon Carbide (SiC) switches are utilized instead of Silicon (Si) switches in the FB-SM. This is due to the fact that SiC devices have lower switching losses than Si devices. The operational principle of LMMMC is described, as well as comparison of its power loss to that of a conventional MMC is presented. The conventional MMC and LMMMC models are simulated in MATLAB Simulink to verify the effectiveness of the proposed converter topology.
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5597-5612
Parallel Hybrid Converter-Based STATCOM and Capacitor Voltage Control Technique
The parallel-hybrid converter (PHC) is a promising high power topology. Smaller capacitor size, lower capacitor and switch counts, and low energy storage requirement are some of its important features. However, it requires a large dc-filter inductor to filter the dc-side harmonics. Moreover, since its dc and ac sides are strongly coupled, only a single stable operating point in terms of a fixed modulation-index (MI) value is possible. Even with an additional dedicated control effort, the obtained MI variation remains still limited. This paper proposes the PHC-STATCOM configuration, which eliminates the dc-filter inductor requirement and can also operate at any MI value without necessitating additional control efforts. A detailed power analysis of the PHC-STATCOM for balanced and unbalanced grid conditions (UGCs) is performed in this paper. A new control technique for PHC-STATCOM is proposed that effectively balances the capacitor voltages of its chain-links even during UGCs. The energy storage requirement of PHC-STATCOM is evaluated to obtain the capability curve and to determine its capacitor size. The PHC-STATCOM is compared with the popular STATCOM configurations in terms of the capacitor and switch counts. The proposed principles of PHC-STATCOM for several three-phase balanced and UGCs are verified using simulation and experimental studies.
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5597-5612
Parallel Hybrid Converter-Based STATCOM and Capacitor Voltage Control Technique
The parallel-hybrid converter (PHC) is a promising high power topology. Smaller capacitor size, lower capacitor and switch counts, and low energy storage requirement are some of its important features. However, it requires a large dc-filter inductor to filter the dc-side harmonics. Moreover, since its dc and ac sides are strongly coupled, only a single stable operating point in terms of a fixed modulation-index (MI) value is possible. Even with an additional dedicated control effort, the obtained MI variation remains still limited. This paper proposes the PHC-STATCOM configuration, which eliminates the dc-filter inductor requirement and can also operate at any MI value without necessitating additional control efforts. A detailed power analysis of the PHC-STATCOM for balanced and unbalanced grid conditions (UGCs) is performed in this paper. A new control technique for PHC-STATCOM is proposed that effectively balances the capacitor voltages of its chain-links even during UGCs. The energy storage requirement of PHC-STATCOM is evaluated to obtain the capability curve and to determine its capacitor size. The PHC-STATCOM is compared with the popular STATCOM configurations in terms of the capacitor and switch counts. The proposed principles of PHC-STATCOM for several three-phase balanced and UGCs are verified using simulation and experimental studies.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (6) , 3752-3764
Investigation of Voltage Sags Effects on ASD and Mitigation Using ESRF Theory-Based DVR
Voltage sag is a frequently occurring power quality disturbance in the industries equipped with adjustable speed drives (ASD). A detailed investigation of voltage sag effects on ASD performance with the novel mathematical analyses to estimate the ASD parameters during different types of voltage sag is discussed in this article. The effects of voltage sags are mitigated using an enhanced synchronous reference frame (ESRF) theory-based dynamic voltage restorer (DVR). The working principle of the ESRF theory-based DVR during sag is also described. The investigation of the effects of type A, type B and type F voltage sags on ASD parameters are verified using the simulation and the experimental studies. Further, these effects are mitigated by the ESRF theory-based DVR using the developed simulation and experimental models. The ESRF controller of DVR is working effectively during voltage sags by improving its transient response, which tightly regulates the DC-link voltage of ASD around its reference value. Also, the steady-state response of DVR is enhanced during severe voltage sag, which further validates the ability of the ESRF theory-based DVR. This type of improved performance of ASD during voltage sags cannot be obtained using other existing SRF theories of the DVR.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (6) , 3752-3764
Investigation of Voltage Sags Effects on ASD and Mitigation Using ESRF Theory-Based DVR
Voltage sag is a frequently occurring power quality disturbance in the industries equipped with adjustable speed drives (ASD). A detailed investigation of voltage sag effects on ASD performance with the novel mathematical analyses to estimate the ASD parameters during different types of voltage sag is discussed in this article. The effects of voltage sags are mitigated using an enhanced synchronous reference frame (ESRF) theory-based dynamic voltage restorer (DVR). The working principle of the ESRF theory-based DVR during sag is also described. The investigation of the effects of type A, type B and type F voltage sags on ASD parameters are verified using the simulation and the experimental studies. Further, these effects are mitigated by the ESRF theory-based DVR using the developed simulation and experimental models. The ESRF controller of DVR is working effectively during voltage sags by improving its transient response, which tightly regulates the DC-link voltage of ASD around its reference value. Also, the steady-state response of DVR is enhanced during severe voltage sag, which further validates the ability of the ESRF theory-based DVR. This type of improved performance of ASD during voltage sags cannot be obtained using other existing SRF theories of the DVR.
- 16 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 598-613
Control and Derived Topologies of Parallel Hybrid Converter
The modular multilevel converter (MMC) is the most preferred VSC-HVDC topology. However, its limitations such as, large energy storage requirements and a large number of devices and capacitors required in its chain-links (CLs), have led to the development of some hybrid multilevel converter topologies. These topologies aim to address the major technical constraints of MMC. The parallel hybrid converter (PHC) is such a hybrid topology, which has evolved as a promising alternative for high power applications because its CLs are not subjected to the fundamental component of ac current and hence the size of its submodule capacitors is substantially lower. Furthermore, for the same power rating, the device count in PHC is only a fraction of that in MMC. However, the PHC suffers from some operational constraints. The dc and ac sides of PHC are strongly coupled, which leads to a single stable operating point resulting in a fixed output voltage if a dedicated controller is not used to tackle this issue. Moreover, the PHC loses control during dc side faults and it also necessitates a bulky dc filter inductor to filter the dc side harmonics. Various advanced control methods and derived PHC topologies have been proposed in literature to eradicate these shortcomings of the PHC. This paper presents a detailed analysis and review of these state of art control strategies and derived PHC topologies. This paper contributes in summarizing key benefits and limitations of various existing control methods through extensive analyses, simulation and experimental studies.
- 16 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 598-613
Control and Derived Topologies of Parallel Hybrid Converter
The modular multilevel converter (MMC) is the most preferred VSC-HVDC topology. However, its limitations such as, large energy storage requirements and a large number of devices and capacitors required in its chain-links (CLs), have led to the development of some hybrid multilevel converter topologies. These topologies aim to address the major technical constraints of MMC. The parallel hybrid converter (PHC) is such a hybrid topology, which has evolved as a promising alternative for high power applications because its CLs are not subjected to the fundamental component of ac current and hence the size of its submodule capacitors is substantially lower. Furthermore, for the same power rating, the device count in PHC is only a fraction of that in MMC. However, the PHC suffers from some operational constraints. The dc and ac sides of PHC are strongly coupled, which leads to a single stable operating point resulting in a fixed output voltage if a dedicated controller is not used to tackle this issue. Moreover, the PHC loses control during dc side faults and it also necessitates a bulky dc filter inductor to filter the dc side harmonics. Various advanced control methods and derived PHC topologies have been proposed in literature to eradicate these shortcomings of the PHC. This paper presents a detailed analysis and review of these state of art control strategies and derived PHC topologies. This paper contributes in summarizing key benefits and limitations of various existing control methods through extensive analyses, simulation and experimental studies.