Baljeet Seniwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Baljeet Seniwal has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Telma Cristina Ferreira Fonseca
Federal University of Minas Gerais
5 shared publications Ademar B Lugão
Nuclear and Energy Research Institute-IPEN/CNEN/SP, São Paulo
1 shared publication- Anna-Kim Péron
Centre de Recherche du CHU de Québec—Université Laval
1 shared publication Bruno M Mendes
Nuclear Technology Development Center-CDTN/, BH / MG
1 shared publication- Bruno Melo Mendes
Centro de Desenvolvimento da Tecnologia Nuclear
1 shared publication C P Bhatt
Sarvodaya Hospital and Research Centre Ghaziabad, Ghaziabad, Uttar Pradesh, INDIA
1 shared publication
Latest Publications
- Open Access
Traumatic brain injury alters hepatic gluconeogenic metabolism assessed using hyperpolarized pyruvate
Background: Acute phase response is an early immunometabolic response to brain injuries, primarily coordinated by the liver via the activation of acute phase proteins. These immune responses can be both beneficial, promoting tissue repair, and detrimental, exacerbating neurological deficits, if not properly controlled. Despite the central role of the liver in immunometabolism, how hepatic metabolism dynamically adapts to traumatic brain injury remains under explored, primarily due to limited liver-specific modalities that can assess metabolic pathways in vivo . 13 C MRI utilizing hyperpolarized 13 C-pyruvate can assess key regulatory enzyme activities in hepatic metabolism. Methods: Rats with controlled cortical impact were studied in vivo using hyperpolarized [1- 13 C]pyruvate and [2- 13 C]pyruvate under fed and fasted conditions 3-4 days after injury. Hyperpolarized 13 C products, including [ 13 C]bicarbonate from [1- 13 C]pyruvate and [5- 13 C]glutamate, [1- 13 C]acetyl-L-carnitine, and [2- 13 C]phosphoenolpyruvate from [2- 13 C]pyruvate, were evaluated to assess mitochondrial and gluconeogenic metabolism. In parallel, liver tissues were collected following [U- 13 C 3 ]pyruvate injection for NMR isotopomer analysis of phosphoenolpyruvate, glucose, and glutamate. Results: While no metabolic differences were detected under fed condition, [ 13 C]bicarbonate and [2- 13 C]phosphoenolpyruvate increased after brain injury under fasted condition, indicating an upregulation of the hepatic gluconeogenic pathway after injury. 13 C NMR of liver tissue extracts from injured rats showed an elevated [2,3- 13 C 2 ]glutamate-to-[4,5- 13 C 2 ]glutamate ratio and increased 13 C-labeling in phosphoenolpyruvate than controls, confirming enhanced hepatic gluconeogenic pathway. Conclusion: This study demonstrates that hepatic acute phase response to brain injuries can be monitored in vivo by hyperpolarized pyruvate, which may be further utilized for longitudinal immunometabolic evaluation of the liver during pathogenesis and therapeutic interventions.
Open AccessTraumatic brain injury alters hepatic gluconeogenic metabolism assessed using hyperpolarized pyruvate
Background: Acute phase response is an early immunometabolic response to brain injuries, primarily coordinated by the liver via the activation of acute phase proteins. These immune responses can be both beneficial, promoting tissue repair, and detrimental, exacerbating neurological deficits, if not properly controlled. Despite the central role of the liver in immunometabolism, how hepatic metabolism dynamically adapts to traumatic brain injury remains under explored, primarily due to limited liver-specific modalities that can assess metabolic pathways in vivo . 13 C MRI utilizing hyperpolarized 13 C-pyruvate can assess key regulatory enzyme activities in hepatic metabolism. Methods: Rats with controlled cortical impact were studied in vivo using hyperpolarized [1- 13 C]pyruvate and [2- 13 C]pyruvate under fed and fasted conditions 3-4 days after injury. Hyperpolarized 13 C products, including [ 13 C]bicarbonate from [1- 13 C]pyruvate and [5- 13 C]glutamate, [1- 13 C]acetyl-L-carnitine, and [2- 13 C]phosphoenolpyruvate from [2- 13 C]pyruvate, were evaluated to assess mitochondrial and gluconeogenic metabolism. In parallel, liver tissues were collected following [U- 13 C 3 ]pyruvate injection for NMR isotopomer analysis of phosphoenolpyruvate, glucose, and glutamate. Results: While no metabolic differences were detected under fed condition, [ 13 C]bicarbonate and [2- 13 C]phosphoenolpyruvate increased after brain injury under fasted condition, indicating an upregulation of the hepatic gluconeogenic pathway after injury. 13 C NMR of liver tissue extracts from injured rats showed an elevated [2,3- 13 C 2 ]glutamate-to-[4,5- 13 C 2 ]glutamate ratio and increased 13 C-labeling in phosphoenolpyruvate than controls, confirming enhanced hepatic gluconeogenic pathway. Conclusion: This study demonstrates that hepatic acute phase response to brain injuries can be monitored in vivo by hyperpolarized pyruvate, which may be further utilized for longitudinal immunometabolic evaluation of the liver during pathogenesis and therapeutic interventions.
- 27 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145019
High-performance dosimetric gel for low-dose-rate 3D-printed brachytherapy devices
Objective. Gel dosimeters have traditionally been developed for external beam radiotherapy and high-energy photon applications. However, their use in low-energy photon contexts—such as low-dose-rate (LDR) brachytherapy—remains limited by challenges related to temporal and thermal stability, as well as water equivalency. This study aimed to develop a novel dosimetric gel adapted to low-energy photon emissions from isotopes such as 125 I and to evaluate its performance using radioactive seeds incorporated into mock LDR 3D-printed brachytherapy implants for eye cancer treatments. Approach. A gel formulation composed of methacrylic and ascorbic acid in gelatin, known as MAGIC, was optimized using agarose (MAGIC-a) and paraformaldehyde (MAGIC-pf). The gel’s thermal and temporal stability and self-polymerization were assessed using magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR) relaxometry. Water equivalency was evaluated using Monte Carlo simulations. The radiation sensitivity of MAGIC-pf gel to 125 I seeds was experimentally measured over two-days, followed by MRI readouts at 1.5 T and 3 T. For comparison, the gel’s sensitivity to a high-energy, high-dose-rate (HDR) 192 Ir source was also assessed. Dose distributions were evaluated using 3D-printed polymer episcleral plaques. Main results. MAGIC-pf demonstrated superior thermal and temporal stability, along with enhanced MRI readout performance. Sensitivity values of MAGIC-pf exposed to 125 I seeds ranged from 0.155 to 0.388 Gy −1 ·s −1 at 1.5 T, and from 0.1 to 0.386 Gy −1 ·s −1 at 3 T. The gel’s sensitivity to a 192 Ir source yielded 0.786 Gy −1 ·s −1 at 1.5 T. 3D-printed polymer episcleral plaques containing three 125 I seeds with asymmetric radiation emission profiles produced highly reproducible and geometrically precise dose distributions, visualized in 2D and 3D. Significance. MAGIC-pf gel demonstrated excellent temporal and thermal stability, compatibility with HDR and LDR brachytherapy applications, and water equivalency under investigated conditions. The sub-millimetric dose profiles it enables are well-suited to the precision demands of next-generation personalized 3D-printed brachytherapy implants.
- 27 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145019
High-performance dosimetric gel for low-dose-rate 3D-printed brachytherapy devices
Objective. Gel dosimeters have traditionally been developed for external beam radiotherapy and high-energy photon applications. However, their use in low-energy photon contexts—such as low-dose-rate (LDR) brachytherapy—remains limited by challenges related to temporal and thermal stability, as well as water equivalency. This study aimed to develop a novel dosimetric gel adapted to low-energy photon emissions from isotopes such as 125 I and to evaluate its performance using radioactive seeds incorporated into mock LDR 3D-printed brachytherapy implants for eye cancer treatments. Approach. A gel formulation composed of methacrylic and ascorbic acid in gelatin, known as MAGIC, was optimized using agarose (MAGIC-a) and paraformaldehyde (MAGIC-pf). The gel’s thermal and temporal stability and self-polymerization were assessed using magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR) relaxometry. Water equivalency was evaluated using Monte Carlo simulations. The radiation sensitivity of MAGIC-pf gel to 125 I seeds was experimentally measured over two-days, followed by MRI readouts at 1.5 T and 3 T. For comparison, the gel’s sensitivity to a high-energy, high-dose-rate (HDR) 192 Ir source was also assessed. Dose distributions were evaluated using 3D-printed polymer episcleral plaques. Main results. MAGIC-pf demonstrated superior thermal and temporal stability, along with enhanced MRI readout performance. Sensitivity values of MAGIC-pf exposed to 125 I seeds ranged from 0.155 to 0.388 Gy −1 ·s −1 at 1.5 T, and from 0.1 to 0.386 Gy −1 ·s −1 at 3 T. The gel’s sensitivity to a 192 Ir source yielded 0.786 Gy −1 ·s −1 at 1.5 T. 3D-printed polymer episcleral plaques containing three 125 I seeds with asymmetric radiation emission profiles produced highly reproducible and geometrically precise dose distributions, visualized in 2D and 3D. Significance. MAGIC-pf gel demonstrated excellent temporal and thermal stability, compatibility with HDR and LDR brachytherapy applications, and water equivalency under investigated conditions. The sub-millimetric dose profiles it enables are well-suited to the precision demands of next-generation personalized 3D-printed brachytherapy implants.
- 8 February 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (4) , 045016
In silico dosimetry of low-dose rate brachytherapy using radioactive nanoparticles
Purpose . Nanoparticles (NPs) with radioactive atoms incorporated within the structure of the NP or bound to its surface, functionalized with biomolecules are reported as an alternative to low-dose-rate seed-based brachytherapy. In this study, authors report a mathematical dosimetric study on low-dose rate brachytherapy using radioactive NPs. Method . Single-cell dosimetry was performed by calculating cellular S -values for spherical cell model using Au-198, Pd-103 and Sm-153 NPs. The cell survival and tumor volume versus time curves were calculated and compared to the experimental studies on radiotherapeutic efficiency of radioactive NPs published in the literature. Finally, the radiotherapeutic efficiency of Au-198, Pd-103 and Sm-153 NPs was tested for variable: administered radioactivity, tumor volume and tumor cell type. Result . At the cellular level Sm-153 presented the highest S -value, followed by Pd-103 and Au-198. The calculated cell survival and tumor volume curves match very well with the published experimental results. It was found that Au-198 and Sm-153 can effectively treat highly aggressive, large tumor volumes with low radioactivity. Conclusion . The accurate knowledge of uptake rate, washout rate of NPs, radio-sensitivity and tumor repopulation rate is important for the calculation of cell survival curves. Self-absorption of emitted radiation and dose enhancement due to AuNPs must be considered in the calculations. Selection of radionuclide for radioactive NP must consider size of tumor, repopulation rate and radiosensitivity of tumor cells. Au-198 NPs functionalized with Mangiferin are a suitable choice for treating large, radioresistant and rapidly growing tumors.
- 8 February 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (4) , 045016
In silico dosimetry of low-dose rate brachytherapy using radioactive nanoparticles
Purpose . Nanoparticles (NPs) with radioactive atoms incorporated within the structure of the NP or bound to its surface, functionalized with biomolecules are reported as an alternative to low-dose-rate seed-based brachytherapy. In this study, authors report a mathematical dosimetric study on low-dose rate brachytherapy using radioactive NPs. Method . Single-cell dosimetry was performed by calculating cellular S -values for spherical cell model using Au-198, Pd-103 and Sm-153 NPs. The cell survival and tumor volume versus time curves were calculated and compared to the experimental studies on radiotherapeutic efficiency of radioactive NPs published in the literature. Finally, the radiotherapeutic efficiency of Au-198, Pd-103 and Sm-153 NPs was tested for variable: administered radioactivity, tumor volume and tumor cell type. Result . At the cellular level Sm-153 presented the highest S -value, followed by Pd-103 and Au-198. The calculated cell survival and tumor volume curves match very well with the published experimental results. It was found that Au-198 and Sm-153 can effectively treat highly aggressive, large tumor volumes with low radioactivity. Conclusion . The accurate knowledge of uptake rate, washout rate of NPs, radio-sensitivity and tumor repopulation rate is important for the calculation of cell survival curves. Self-absorption of emitted radiation and dose enhancement due to AuNPs must be considered in the calculations. Selection of radionuclide for radioactive NP must consider size of tumor, repopulation rate and radiosensitivity of tumor cells. Au-198 NPs functionalized with Mangiferin are a suitable choice for treating large, radioresistant and rapidly growing tumors.
- Open Access
- 1 December 2020
- Published by Elsevier in Physica Medica
- Vol. 80, 363-372
Monte Carlo assessment of low energy electron range in liquid water and dosimetry effects
- 1 December 2020
- Published by Elsevier in Physica Medica
- Vol. 80, 363-372
Open AccessMonte Carlo assessment of low energy electron range in liquid water and dosimetry effects
- 1 December 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 166, 109302
Microdosimetric calculations for radionuclides emitting β and α particles and Auger electrons
- 1 December 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 166, 109302
Microdosimetric calculations for radionuclides emitting β and α particles and Auger electrons
- 1 January 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (1) , 015035
Comparison of dosimetric accuracy of acuros XB and analytical anisotropic algorithm against Monte Carlo technique
This study reports the comparison between two dose calculation algorithms, Acuros XB 13.5 (AXB) and Analytical Anisotropic Algorithm (AAA) against Monte Carlo (MC) simulations for 3D-Conformal Radiation Therapy (3D-CRT) using a female pelvic rando phantom. 3D-CRT treatment plans were generated on the CT images of rando phantom using AXB and AAA with Source to Axis Distance (SAD) technique. Doses obtained using two algorithms and MC results were compared using MATLAB based software CERR. In house MATLAB code was developed to calculate the gamma dose distribution comparison in terms of dose difference (DD) and distance to agreement distribution (DTA). The results showed that the D mean in the PTV TOTAL (PTV) volume for AXB and AAA was equal to the mean dose calculated by MC simulations. The gamma passing rates for AXB were more accurate in comparison to AAA with reference to MC for PTV, Bladder and Femoral Heads region. After analysing the dose comparison specially for the PTV, femoral heads, also the analysis of dose volume histogram (DVH) and gamma dose distribution comparison for PTV, femoral heads and bladder, it can be concluded that AXB is more accurate in comparison to AAA. It can be said that AXB is well suited for dose calculation in clinical setup when compared to MC calculations.
- 1 January 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (1) , 015035
Comparison of dosimetric accuracy of acuros XB and analytical anisotropic algorithm against Monte Carlo technique
This study reports the comparison between two dose calculation algorithms, Acuros XB 13.5 (AXB) and Analytical Anisotropic Algorithm (AAA) against Monte Carlo (MC) simulations for 3D-Conformal Radiation Therapy (3D-CRT) using a female pelvic rando phantom. 3D-CRT treatment plans were generated on the CT images of rando phantom using AXB and AAA with Source to Axis Distance (SAD) technique. Doses obtained using two algorithms and MC results were compared using MATLAB based software CERR. In house MATLAB code was developed to calculate the gamma dose distribution comparison in terms of dose difference (DD) and distance to agreement distribution (DTA). The results showed that the D mean in the PTV TOTAL (PTV) volume for AXB and AAA was equal to the mean dose calculated by MC simulations. The gamma passing rates for AXB were more accurate in comparison to AAA with reference to MC for PTV, Bladder and Femoral Heads region. After analysing the dose comparison specially for the PTV, femoral heads, also the analysis of dose volume histogram (DVH) and gamma dose distribution comparison for PTV, femoral heads and bladder, it can be concluded that AXB is more accurate in comparison to AAA. It can be said that AXB is well suited for dose calculation in clinical setup when compared to MC calculations.
- Open Access
- 18 December 2019
- Published by IntechOpen
Prospective Monte Carlo Simulation for Choosing High Efficient Detectors for Small-Field Dosimetry
In this chapter, a detailed study on physics and methodology of small field dosimetry are reported. It introduces talking about how small radiation fields came into existence and the importance of accurate small-field dosimetry. In addition, it discusses small and long cavity theories for evaluating accurate dose response. It sheds the spot on pencil beam algorithms for evaluating dose response and uses Monte Carlo (MC) simulation in categorizing primary and scattering components of the radiotherapeutic photon beam. Moreover, it summarizes all commercial dosimeters used in small-field dosimetry. It gives good knowledge about detectors and equipment like ionization chambers for reference dosimetry in small and non-reference fields and different types of solid-state detector. The importance and applications of Monte Carlo techniques in small-field dosimetry and radiotherapeutic treatment methods based on small field are reported. For this purpose, different commonly used Monte Carlo codes are handled like Electron Gamma Shower (EGSnrc), Geant4, PENELOPE, and Monte Carlo N-Particle (MCNP). A review on the recent studies of using Monte Carlo simulation particularly on the small-field dosimetric studies is also reported. This chapter also discusses the recommendations of the code of practices (COPs) for dosimetry of small radiation fields. It mentions all recommendations provided by TRS-483 for accurate beam data collection and accurate dosimetric measurements. It gives good knowledge to the user for selecting a suitable dosimeter in small-field dosimetry through investigation of different practical methods and Monte Carlo simulations.
- 18 December 2019
- Published by IntechOpen
Open AccessProspective Monte Carlo Simulation for Choosing High Efficient Detectors for Small-Field Dosimetry
In this chapter, a detailed study on physics and methodology of small field dosimetry are reported. It introduces talking about how small radiation fields came into existence and the importance of accurate small-field dosimetry. In addition, it discusses small and long cavity theories for evaluating accurate dose response. It sheds the spot on pencil beam algorithms for evaluating dose response and uses Monte Carlo (MC) simulation in categorizing primary and scattering components of the radiotherapeutic photon beam. Moreover, it summarizes all commercial dosimeters used in small-field dosimetry. It gives good knowledge about detectors and equipment like ionization chambers for reference dosimetry in small and non-reference fields and different types of solid-state detector. The importance and applications of Monte Carlo techniques in small-field dosimetry and radiotherapeutic treatment methods based on small field are reported. For this purpose, different commonly used Monte Carlo codes are handled like Electron Gamma Shower (EGSnrc), Geant4, PENELOPE, and Monte Carlo N-Particle (MCNP). A review on the recent studies of using Monte Carlo simulation particularly on the small-field dosimetric studies is also reported. This chapter also discusses the recommendations of the code of practices (COPs) for dosimetry of small radiation fields. It mentions all recommendations provided by TRS-483 for accurate beam data collection and accurate dosimetric measurements. It gives good knowledge to the user for selecting a suitable dosimeter in small-field dosimetry through investigation of different practical methods and Monte Carlo simulations.