Philip C. Noble
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Philip C. Noble has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Adam M. Freedhand
Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Orthoped Surg, Houston, TX USA
2 shared publicationsSabir K. Ismaily
Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Orthoped Surg, Houston, TX USA
2 shared publications- Shuyang Han
Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Texas
2 shared publications Alexander V. Boiwka
Department of Orthopedic Surgery, McGovern Medical School, UTHealth-Houston, 5420 West Loop South, Suite 1300, Houston, TX 77401, USA
1 shared publicationDavid Rodriguez-Quintana
Department of Orthopedic Surgery, McGovern Medical School, UTHealth-Houston, 5420 West Loop South, Suite 1300, Houston, TX 77401, USA
1 shared publicationDavid Rodriguze-Quintana
Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Orthoped Surg, Houston, TX USA
1 shared publication
Latest Publications
- 6 July 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 118, 106303
Contributions of capsular releases to femoral exposure in total hip arthroplasty via the direct anterior approach
- 6 July 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 118, 106303
Contributions of capsular releases to femoral exposure in total hip arthroplasty via the direct anterior approach
- Open Access
- 1 June 2021
- Published by Elsevier in Bone Reports
- Vol. 14, 101074
Designing and validation of an automated ex-vivo bioreactor system for long term culture of bone
- 1 June 2021
- Published by Elsevier in Bone Reports
- Vol. 14, 101074
Open AccessDesigning and validation of an automated ex-vivo bioreactor system for long term culture of bone
- 1 April 2021
- Published by Elsevier in Orthopedic Clinics of North America
- Vol. 52 (2) , 83-92
Contemporary Robotic Systems in Total Knee Arthroplasty
- 1 April 2021
- Published by Elsevier in Orthopedic Clinics of North America
- Vol. 52 (2) , 83-92
Contemporary Robotic Systems in Total Knee Arthroplasty
- 22 January 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (8) , 1779-1786
The continuum of hip range of motion: From soft‐tissue restriction to bony impingement
Traditional studies of hip kinematics have not identified which anatomic structures limit the range of motion (ROM) when the hip is placed in different maneuvers. In this study, we attempted to answer two questions: (a) During which maneuvers is the motion of the hip limited by bony impingement between the femur and pelvis? (b) When is hip ROM determined by the constraint of soft tissues and to what extent? ROM of eight cadaveric hips was measured in 17 maneuvers using a motion capture system. The maneuvers were recreated in silico using 3D CT models of each specimen to detect the occurrence of bony impingement. If bony impingement was not detected, the variable component of 3D hip motion was increased until a collision was detected. The difference between the virtual ROM at the point of bony impingement and the initial ROM measured experimentally was termed as the soft‐tissue restriction. The results showed that bony impingement was present in normal hips during maneuvers consisting of high abduction with flexion, and high flexion combined with adduction and internal rotation. At impingement‐free maneuvers, the degree of soft tissue restriction varies remarkably, ranging from 4.9° ± 3.8° (internal rotation) at 90° of flexion to 80.0° ± 12.5° (internal rotation) at maximum extension. The findings shed light on the relative contributions of osseous and soft tissues to the motion of the hip in different maneuvers and allow for a better understanding of physical exams of different purposes in diagnosing bone‐ or soft tissue‐related diseases.
- 22 January 2020
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (8) , 1779-1786
The continuum of hip range of motion: From soft‐tissue restriction to bony impingement
Traditional studies of hip kinematics have not identified which anatomic structures limit the range of motion (ROM) when the hip is placed in different maneuvers. In this study, we attempted to answer two questions: (a) During which maneuvers is the motion of the hip limited by bony impingement between the femur and pelvis? (b) When is hip ROM determined by the constraint of soft tissues and to what extent? ROM of eight cadaveric hips was measured in 17 maneuvers using a motion capture system. The maneuvers were recreated in silico using 3D CT models of each specimen to detect the occurrence of bony impingement. If bony impingement was not detected, the variable component of 3D hip motion was increased until a collision was detected. The difference between the virtual ROM at the point of bony impingement and the initial ROM measured experimentally was termed as the soft‐tissue restriction. The results showed that bony impingement was present in normal hips during maneuvers consisting of high abduction with flexion, and high flexion combined with adduction and internal rotation. At impingement‐free maneuvers, the degree of soft tissue restriction varies remarkably, ranging from 4.9° ± 3.8° (internal rotation) at 90° of flexion to 80.0° ± 12.5° (internal rotation) at maximum extension. The findings shed light on the relative contributions of osseous and soft tissues to the motion of the hip in different maneuvers and allow for a better understanding of physical exams of different purposes in diagnosing bone‐ or soft tissue‐related diseases.