L. Q. Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
L. Q. Zhou has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Rachel S. Edwards
University of Warwick
3 shared publications - A. Nikitin
Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
2 shared publications - Ben Tudor‐Green
University of Warwick
2 shared publications G. Colston
Department of Physics, University of Warwick, Coventry CV4 7AL, U.K.
2 shared publications- Gavin W. Morley
Department of Physics University of Warwick Gibbet Hill Road CV4 7AL Coventry United Kingdom
2 shared publications - Oksana Trushkevych
Department of Physics, University of Warwick, Coventry CV4 7AL, UK
2 shared publications
Latest Publications
- Open Access
- 5 February 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (2) , 024015
Imaging Damage in Steel Using a Diamond Magnetometer
We demonstrate a simple, robust, and contactless method for nondestructive testing of magnetic materials such as steel. This uses a fiber-coupled magnetic sensor based on nitrogen-vacancy centers (NVCs) in diamond without magnetic shielding. Previous NVC magnetometry has sought a homogeneous bias magnetic field on the diamond to improve the sensitivity. In contrast, here we show that the spatial resolution for imaging is improved by applying an inhomogeneous magnetic field to the steel even though this leads to an inhomogeneous magnetic field on the diamond. Structural damage in the steel distorts the inhomogeneous magnetic field and by detecting this distortion we reconstruct the damage profile through quantifying the shifts in the NVC Zeeman splitting. With a 1-mm magnet as the source of our inhomogeneous magnetic field, we achieve a high spatial resolution of 1 mm in the plane parallel and 0.1 mm in the direction perpendicular to the surface of the steel. This works even when the steel is covered by a nonmagnetic material. The lift-off distance of our sensor head from the surface of 316 stainless steel is up to 3 mm.
- 5 February 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (2) , 024015
Open AccessImaging Damage in Steel Using a Diamond Magnetometer
We demonstrate a simple, robust, and contactless method for nondestructive testing of magnetic materials such as steel. This uses a fiber-coupled magnetic sensor based on nitrogen-vacancy centers (NVCs) in diamond without magnetic shielding. Previous NVC magnetometry has sought a homogeneous bias magnetic field on the diamond to improve the sensitivity. In contrast, here we show that the spatial resolution for imaging is improved by applying an inhomogeneous magnetic field to the steel even though this leads to an inhomogeneous magnetic field on the diamond. Structural damage in the steel distorts the inhomogeneous magnetic field and by detecting this distortion we reconstruct the damage profile through quantifying the shifts in the NVC Zeeman splitting. With a 1-mm magnet as the source of our inhomogeneous magnetic field, we achieve a high spatial resolution of 1 mm in the plane parallel and 0.1 mm in the direction perpendicular to the surface of the steel. This works even when the steel is covered by a nonmagnetic material. The lift-off distance of our sensor head from the surface of 316 stainless steel is up to 3 mm.
- Open Access
- 30 October 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 14 (4) , 044058
Subnanotesla Magnetometry with a Fiber-Coupled Diamond Sensor
Nitrogen-vacancy centers (NVCs) in diamond are being explored for future quantum technologies, and in particular ensembles of NVC are the basis for sensitive magnetometers. We present a fiber-coupled NVC magnetometer with an unshielded sensitivity of in the frequency range of 10–150 Hz at room temperature. This takes advantage of low-strain diamond, lenses for fiber coupling and optimization of microwave modulation frequency, modulation amplitude, and power. Fiber coupling means the sensor can be conveniently brought within 2 mm of the object under study.- 30 October 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 14 (4) , 044058
Open AccessSubnanotesla Magnetometry with a Fiber-Coupled Diamond Sensor
Nitrogen-vacancy centers (NVCs) in diamond are being explored for future quantum technologies, and in particular ensembles of NVC are the basis for sensitive magnetometers. We present a fiber-coupled NVC magnetometer with an unshielded sensitivity of in the frequency range of 10–150 Hz at room temperature. This takes advantage of low-strain diamond, lenses for fiber coupling and optimization of microwave modulation frequency, modulation amplitude, and power. Fiber coupling means the sensor can be conveniently brought within 2 mm of the object under study. - Open Access
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (3) , 370-377
Ultrasonic Inspection and Self-Healing of Ge and 3C-SiC Semiconductor Membranes
Knowledge of the mechanical properties and stability of thin film structures is important for device operation. Potential failures related to crack initiation and growth must be identified early, to enable healing through e.g. annealing. Here, three square suspended membranes, formed from a thin layer of cubic silicon carbide (3C-SiC) or germanium (Ge) on a silicon substrate, were characterised by their response to ultrasonic excitation. The resonant frequencies and mode shapes were measured during thermal cycling over a temperature range of 20-100 °C. The influence of temperature on the stress was explored by comparison with predictions from a model of thermal expansion of the combined membrane and substrate. For an ideal, non-cracked sample the stress and Q-factor behaved as predicted. In contrast, for a 3C-SiC and a Ge membrane that had undergone vibration and thermal cycling to simulate extended use, measurements of the stress and Q-factor showed the presence of damage, with the 3C-SiC membrane subsequently breaking. However, the damaged Ge sample showed an improvement to the resonant behaviour on subsequent heating. Scanning electron microscopy showed that this was due to a self-healing of sub-micrometer cracks, caused by expansion of the germanium layer to form bridges over the cracked regions, with the effect also observable in the ultrasonic inspection. [2020-0017]
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (3) , 370-377
Open AccessUltrasonic Inspection and Self-Healing of Ge and 3C-SiC Semiconductor Membranes
Knowledge of the mechanical properties and stability of thin film structures is important for device operation. Potential failures related to crack initiation and growth must be identified early, to enable healing through e.g. annealing. Here, three square suspended membranes, formed from a thin layer of cubic silicon carbide (3C-SiC) or germanium (Ge) on a silicon substrate, were characterised by their response to ultrasonic excitation. The resonant frequencies and mode shapes were measured during thermal cycling over a temperature range of 20-100 °C. The influence of temperature on the stress was explored by comparison with predictions from a model of thermal expansion of the combined membrane and substrate. For an ideal, non-cracked sample the stress and Q-factor behaved as predicted. In contrast, for a 3C-SiC and a Ge membrane that had undergone vibration and thermal cycling to simulate extended use, measurements of the stress and Q-factor showed the presence of damage, with the 3C-SiC membrane subsequently breaking. However, the damaged Ge sample showed an improvement to the resonant behaviour on subsequent heating. Scanning electron microscopy showed that this was due to a self-healing of sub-micrometer cracks, caused by expansion of the germanium layer to form bridges over the cracked regions, with the effect also observable in the ultrasonic inspection. [2020-0017]
- Open Access
- 27 January 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 116 (4) , 044104
The interaction of polymer dispersed liquid crystal sensors with ultrasound
Polymer dispersed liquid crystals (PDLCs) have been shown to be sensitive to ultrasound through the acousto-optic effect. The acousto-optic response of PDLCs was studied over a broad frequency range (0.3–10 MHz). We demonstrate that the displacements required to produce acousto-optic clearing of PDLC films can be as low as a few nanometers, which is at least 103 times smaller than the PDLC droplet size, is 105 times smaller than the PDLC layer thickness, and of the order of the molecular size of the liquid crystal constituents. This suggests that the acousto-optic effect in PDLCs is due to the microscopic effects of the LC reorientation under torques or flows rather than the LC reorientation through macroscopic droplet deformation. The displacement required for clearing is related to the frequency of operation via an exponential decay. We attribute the observed frequency response to a freezing out of the rotational motion around the short axis of the liquid crystal. The reported frequency dependence and displacements required indicate that the effects and materials described here could be used for ultrasound visualization in a non-destructive testing context.
- 27 January 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 116 (4) , 044104
Open AccessThe interaction of polymer dispersed liquid crystal sensors with ultrasound
Polymer dispersed liquid crystals (PDLCs) have been shown to be sensitive to ultrasound through the acousto-optic effect. The acousto-optic response of PDLCs was studied over a broad frequency range (0.3–10 MHz). We demonstrate that the displacements required to produce acousto-optic clearing of PDLC films can be as low as a few nanometers, which is at least 103 times smaller than the PDLC droplet size, is 105 times smaller than the PDLC layer thickness, and of the order of the molecular size of the liquid crystal constituents. This suggests that the acousto-optic effect in PDLCs is due to the microscopic effects of the LC reorientation under torques or flows rather than the LC reorientation through macroscopic droplet deformation. The displacement required for clearing is related to the frequency of operation via an exponential decay. We attribute the observed frequency response to a freezing out of the rotational motion around the short axis of the liquid crystal. The reported frequency dependence and displacements required indicate that the effects and materials described here could be used for ultrasound visualization in a non-destructive testing context.
- 3 July 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (1) , 011904
Non-linear vibrational response of Ge and SiC membranes
Characterisation of membranes produced for use as micro-electro-mechanical systems using vibrational techniques can give a measure of their behaviour and suitability for operation in different environments. Two membranes are studied here: germanium (Ge) and cubic silicon carbide (3C-SiC) on a silicon (Si) substrate. When driven at higher displacements, the membranes exhibit self-protecting behaviour. The resonant vibration amplitude is limited to a maximum value of around 10 nm, through dissipation of energy via higher harmonic vibrations. This is observed for both materials, despite their different Young's moduli and defect densities.
- 3 July 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (1) , 011904
Non-linear vibrational response of Ge and SiC membranes
Characterisation of membranes produced for use as micro-electro-mechanical systems using vibrational techniques can give a measure of their behaviour and suitability for operation in different environments. Two membranes are studied here: germanium (Ge) and cubic silicon carbide (3C-SiC) on a silicon (Si) substrate. When driven at higher displacements, the membranes exhibit self-protecting behaviour. The resonant vibration amplitude is limited to a maximum value of around 10 nm, through dissipation of energy via higher harmonic vibrations. This is observed for both materials, despite their different Young's moduli and defect densities.