A. Nikitin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. Nikitin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Gavin W. Morley
Department of Physics University of Warwick Gibbet Hill Road CV4 7AL Coventry United Kingdom
3 shared publications A.M. Edmonds
Element Six Innovation, Didcot OX11 0QR, United Kingdom
2 shared publications- Ben Tudor‐Green
University of Warwick
2 shared publications D.J. Twitchen
Element Six Innovation, Didcot OX11 0QR, United Kingdom
2 shared publications- L. Q. Zhou
Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
2 shared publications A. C. Frangeskou
Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
1 shared publication
Latest Publications
- Top Cited Papers
- 14 April 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (4) , 044042
Fiber-Coupled Diamond Magnetometry with an Unshielded Sensitivity ofEnsembles of nitrogen-vacancy centers (NVCs) in diamond can be employed for sensitive magnetometry. In this work, we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of in a (10–500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias-field alignment, microwave and lock-in amplifier (LIA) parameter optimization, as well as a balanced hyperfine-excitation scheme. Furthermore, a silicon carbide () heat spreader is used for microwave delivery, alongside low-strain 1- diamonds, one of which is placed in a second magnetically insensitive fluorescence-collecting sensor head for common-mode noise cancellation. The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with some orientation dependence but no complete dead zones, demonstrating its potential for use in remote-sensing applications.- 14 April 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (4) , 044042
Top Cited PapersFiber-Coupled Diamond Magnetometry with an Unshielded Sensitivity ofEnsembles of nitrogen-vacancy centers (NVCs) in diamond can be employed for sensitive magnetometry. In this work, we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of in a (10–500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias-field alignment, microwave and lock-in amplifier (LIA) parameter optimization, as well as a balanced hyperfine-excitation scheme. Furthermore, a silicon carbide () heat spreader is used for microwave delivery, alongside low-strain 1- diamonds, one of which is placed in a second magnetically insensitive fluorescence-collecting sensor head for common-mode noise cancellation. The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with some orientation dependence but no complete dead zones, demonstrating its potential for use in remote-sensing applications. - Open Access
- 5 February 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (2) , 024015
Imaging Damage in Steel Using a Diamond Magnetometer
We demonstrate a simple, robust, and contactless method for nondestructive testing of magnetic materials such as steel. This uses a fiber-coupled magnetic sensor based on nitrogen-vacancy centers (NVCs) in diamond without magnetic shielding. Previous NVC magnetometry has sought a homogeneous bias magnetic field on the diamond to improve the sensitivity. In contrast, here we show that the spatial resolution for imaging is improved by applying an inhomogeneous magnetic field to the steel even though this leads to an inhomogeneous magnetic field on the diamond. Structural damage in the steel distorts the inhomogeneous magnetic field and by detecting this distortion we reconstruct the damage profile through quantifying the shifts in the NVC Zeeman splitting. With a 1-mm magnet as the source of our inhomogeneous magnetic field, we achieve a high spatial resolution of 1 mm in the plane parallel and 0.1 mm in the direction perpendicular to the surface of the steel. This works even when the steel is covered by a nonmagnetic material. The lift-off distance of our sensor head from the surface of 316 stainless steel is up to 3 mm.
- 5 February 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (2) , 024015
Open AccessImaging Damage in Steel Using a Diamond Magnetometer
We demonstrate a simple, robust, and contactless method for nondestructive testing of magnetic materials such as steel. This uses a fiber-coupled magnetic sensor based on nitrogen-vacancy centers (NVCs) in diamond without magnetic shielding. Previous NVC magnetometry has sought a homogeneous bias magnetic field on the diamond to improve the sensitivity. In contrast, here we show that the spatial resolution for imaging is improved by applying an inhomogeneous magnetic field to the steel even though this leads to an inhomogeneous magnetic field on the diamond. Structural damage in the steel distorts the inhomogeneous magnetic field and by detecting this distortion we reconstruct the damage profile through quantifying the shifts in the NVC Zeeman splitting. With a 1-mm magnet as the source of our inhomogeneous magnetic field, we achieve a high spatial resolution of 1 mm in the plane parallel and 0.1 mm in the direction perpendicular to the surface of the steel. This works even when the steel is covered by a nonmagnetic material. The lift-off distance of our sensor head from the surface of 316 stainless steel is up to 3 mm.
- Open Access
- 30 October 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 14 (4) , 044058
Subnanotesla Magnetometry with a Fiber-Coupled Diamond Sensor
Nitrogen-vacancy centers (NVCs) in diamond are being explored for future quantum technologies, and in particular ensembles of NVC are the basis for sensitive magnetometers. We present a fiber-coupled NVC magnetometer with an unshielded sensitivity of in the frequency range of 10–150 Hz at room temperature. This takes advantage of low-strain diamond, lenses for fiber coupling and optimization of microwave modulation frequency, modulation amplitude, and power. Fiber coupling means the sensor can be conveniently brought within 2 mm of the object under study.- 30 October 2020
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 14 (4) , 044058
Open AccessSubnanotesla Magnetometry with a Fiber-Coupled Diamond Sensor
Nitrogen-vacancy centers (NVCs) in diamond are being explored for future quantum technologies, and in particular ensembles of NVC are the basis for sensitive magnetometers. We present a fiber-coupled NVC magnetometer with an unshielded sensitivity of in the frequency range of 10–150 Hz at room temperature. This takes advantage of low-strain diamond, lenses for fiber coupling and optimization of microwave modulation frequency, modulation amplitude, and power. Fiber coupling means the sensor can be conveniently brought within 2 mm of the object under study. - 30 October 2007
- Published by American Physical Society (APS) in Physical Review E
- Vol. 76 (4) , 041138
Asymmetric bistable systems subject to periodic and stochastic forcing in the strongly nonlinear regime: The power spectrum
In this, the fourth of a series of papers [the first three papers were Phys. Rev. E 68, 016103 (2003), 68, 036133 (2003), and Phys. Lett. A 334, 12 (2005)] on the response of overdamped noisy bistable systems subject to an asymmetrizing constant signal superimposed on a time-sinusoidal driving signal, we obtain analytic expressions for the power spectral density of the response, including a detailed theoretical analysis of the power spectrum. The results are valid for any two-state system, however the specific case of the Duffing (or standard quartic) potential is considered in detail. The stochastic dynamics are confined to the weak noise limit (periodic signal amplitude much greater than noise intensity), i.e., when the response of the system to the external periodic field is strongly nonlinear.
- 30 October 2007
- Published by American Physical Society (APS) in Physical Review E
- Vol. 76 (4) , 041138
Asymmetric bistable systems subject to periodic and stochastic forcing in the strongly nonlinear regime: The power spectrum
In this, the fourth of a series of papers [the first three papers were Phys. Rev. E 68, 016103 (2003), 68, 036133 (2003), and Phys. Lett. A 334, 12 (2005)] on the response of overdamped noisy bistable systems subject to an asymmetrizing constant signal superimposed on a time-sinusoidal driving signal, we obtain analytic expressions for the power spectral density of the response, including a detailed theoretical analysis of the power spectrum. The results are valid for any two-state system, however the specific case of the Duffing (or standard quartic) potential is considered in detail. The stochastic dynamics are confined to the weak noise limit (periodic signal amplitude much greater than noise intensity), i.e., when the response of the system to the external periodic field is strongly nonlinear.