EVElke Vereecke

Elke Vereecke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Elke Vereecke has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spondyloarthritis endgame: MRI versus BoneMRI in sacroiliitis

    by Kelly Di Dier, Frederiek Laloo, Thomas Van Den Berghe, Elke Vereecke, Jacob Jaremko, Min Chen, Lennart Jans

    The Assessment in SpondyloArthritis International Society (ASAS) classification criteria characterize sacroiliitis by active inflammation and structural lesions. Detection of lesions such as bone marrow edema, joint surface erosions and ankylosis is important, because progressing treatment options benefit from early diagnosis and detailed treatment response monitoring. Recent technological advancements have made various imaging modalities available to assess these findings, i.e., various sorts of CT (low dose, dual energy, etc.), MRI and BoneMRI. BoneMRI is an advanced technique where CT-like images are reconstructed from a dedicated MRI sequence, opening opportunities to better characterize structural lesions than on a classic MRI study. The scope of this review is to provide an overview of the pros and cons of MRI and BoneMRI in sacroiliitis and demonstrate the inherent added value of BoneMRI towards state-of-the-art routine MRI sequences.


  • Open Access

    Ureteric Compression and Postural Venous Outflow Obstruction by a Gravid Uterus in a Kidney Transplant Recipient: A Case Report

    by Steven Van Laecke, Elke Vereecke, Aliaksandr Anisau, Sophie Pomme, Thomas Tailly, Kristien Roelens, Evi V. Nagler

  • Association of anatomical variants of the sacroiliac joint with bone marrow edema in patients with axial spondyloarthritis

    by Elke Vereecke, Lennart Jans, Nele Herregods, Min Chen, Jacob L. Jaremko, Frederiek Laloo, Philippe Carron, Gaëlle Varkas, Manouk de Hooge, Filip Van Den Bosch, et al.

    Objective To determine the prevalence of sacroiliac joint variants in patients with axial spondyloarthritis (axSpA) using MRI-based synthetic CT images and to evaluate their relationships with the presence of bone marrow edema, as this may potentially complicate diagnosing active sacroiliitis on MRI in patients with suspected axSpA. Methods 172 patients were retrospectively included. All patients underwent MRI because of clinical suspicion of sacroiliitis. The diagnosis of axSpA was made by a tertiary hospital rheumatologist. Two readers independently determined the presence of bone marrow edema and the presence of one or more of the nine known sacroiliac joint (SIJ) variants. Results SIJ variants were common in axSpA patients (82.9%) and the non-SpA group (85.4%); there were no significant differences in prevalence. Bone marrow edema was frequently found in axSpA (86.8%) and non-SpA patients (34%). AxSpA patients with SIJ variants (except for accessory joint) demonstrated 4 to 10 times higher odds for bone marrow edema, however not statistically significant. The more variants were present in this group, the higher the chance of bone marrow edema. However, some multicollinearity cannot be excluded, since bone marrow edema is very frequent in the axSpA group by definition. Conclusion SIJ variants are common in axSpA and non-SpA patients. SIJ variants were associated with higher prevalence of bone marrow edema in axSpA patients, potentially due to altered biomechanics, except for accessory joint which may act as a stabilizer.


  • Open Access

    Anatomical variation of the sacroiliac joints: an MRI study with synthetic CT images

    by Elke Vereecke, Lieve Morbée, Frederiek Laloo, Min Chen, Jacob L. Jaremko, Nele Herregods, Lennart Jans

    Background: Synthetic computed tomography (sCT) images are magnetic resonance imaging (MRI)-based images, generated using artificial intelligence. This study aimed to determine the prevalence of anatomical variants of sacroiliac joints (SIJ) on sCT images and the correlation with age, sex and body weight. Methods: MRI of the SIJ including sCT images of 215 patients clinically suspected for sacroiliitis were retrospectively analyzed. The presence of anatomical variants of the SIJ was assessed. Age, sex and body mass index at the time of the MRI were recorded. Results: SIJ variants were found in 82.8% (356/430) of the evaluated joints. The most frequent variants were iliosacral complex (27.7%), bipartite iliac bony plate (27.2%) and crescent iliac bony plate (27%). One new variant was identified, consisting of an accessory facet of the SIJ on the superior side. Overall, SIJ variants were slightly more frequent in women (85.8% vs. 77.8%), but iliosacral complex was significantly more frequent in men. Isolated synostosis was more prevalent with advancing age, in contrast to semicircular defect and unfused ossification center. The occurrence of iliosacral complex was associated with higher BMI, while crescent iliac bony plate occurred more in patients with lower BMI. Conclusion: Over 80% of patients in this study, who were all suspected of sacroiliitis, had at least one SIJ variant. These variants may actually represent subtypes of the normal SIJ. sCT enables detection of very small or subtle findings including SIJ variants.


  • Open Access

    Intraspinal Azygos Vein

    by Joanna Knapik, Elke Vereecke, Lieve Morbée

    Teaching Point: Intraspinal azygos vein is an extremely rare anatomical variant; knowledge is important for correct imaging interpretation.

  • Imaging of Structural Abnormalities of the Sacrum: The Old Faithful and Newly Emerging Techniques

    by Elke Vereecke, Nele Herregods, Lieve Morbée, Frederiek Laloo, Min Chen, Lennart Jans

    The sacrum and sacroiliac joints pose a long-standing challenge for adequate imaging because of their complex anatomical form, oblique orientation, and posterior location in the pelvis, making them subject to superimposition. The sacrum and sacroiliac joints are composed of multiple diverse tissues, further complicating their imaging. Varying imaging techniques are suited to evaluate the sacrum, each with its specific clinical indications, benefits, and drawbacks. New techniques continue to be developed and validated, such as dual-energy computed tomography (CT) and new magnetic resonance imaging (MRI) sequences, for example susceptibility-weighted imaging. Ongoing development of artificial intelligence, such as algorithms allowing reconstruction of MRI-based synthetic CT images, promises even more clinical imaging options.


  • Open Access

    Characterizing Scatter Correction Software of 5 Mobile Radiography Units

    by Tim Msc Gossye, Dimitri Msc Buytaert, Peter V. Smeets, Lieve Morbée, Elke Vereecke, Eric Achten, Klaus Bacher

    Objectives: Bedside radiographs are usually obtained gridless, without a physical scatter correction grid because of several limitations. Therefore, multiple manufacturers of mobile radiography systems provide the possibility to apply scatter correction software (SC SW) on those images. The purpose of this study was to characterize different series of radiographs—gridless, SC SW, and physical grid—with an image quality assessment algorithm (IQAA). Furthermore, we investigated the potential dose reduction and the correlation between the output of the IQAA and the human observers. Materials and Methods: We obtained different series of radiographs with an anthropomorphic phantom (multipurpose chest phantom N1 “Lungman,” Kyoto Kagaku, Kyoto, Japan). All radiographs were obtained with flat-panel detectors of 5 different manufacturers in a wall bucky system. An IQAA to analyze the radiographs was implemented in our department but was originally developed by the research group of the Duke University Medical Center. Seven physical quantities were calculated by the IQAA: rib-lung contrast (RLcontrast ), subdiaphragm-lung contrast (SLcontrast ), lung detail (Ldetail ), mediastinum detail (Mdetail ), lung noise (Lnoise ), mediastinum noise (Mnoise ), and rib-lung sharpness (RLsharpness ). In a proof of concept, the results of the IQAA were validated by 3 experienced radiologists. Results: Regression coefficients (b) of the linear regression model indicate that the human observer results correlate well with the IQAA (b ≥ 0.89, R 2 ≥ 0.83). All manufacturers have SC SW that increases the 7 physical quantities of the gridless images. However, several manufacturers have SC SW that increases the physical metrics to the same level as the physical grid images. The SC SW radiographs obtained with a reduced tube load have an increased level of contrast, detail, sharpness, and noise compared with the gridless images obtained with the higher tube load. Conclusions: We have proven in a proof of concept that the originally developed IQAA can be used to characterize different series of images of different manufacturers. Based on the physical quantities, SC SW increases the contrast, detail, sharpness, and noise. The experimental results in this study assume a patient dose reduction could be possible when SC SW is applied.


  • Open Access

    Renal Arteriovenous Fistula

    by Mats Van Den Broecke, Elke Vereecke, Pieter De Visschere

    Teaching Point: Color Doppler ultrasound (US) is useful for screening for renal arteriovenous (AV) shunts, especially following renal biopsy, because of its convenience and minimally invasive nature.


  • Open Access

    MR Imaging of the Pelvic Bones: The Current and Cutting-Edge Techniques

    by Lieve Morbee, Elke Vereecke, Frederiek Laloo, Min Chen, Nele Herregods, Lennart Jans

    This review presents an overview of the spectrum of the current and cutting-edge MRI techniques for pelvic bone imaging in clinical practice. The current MRI sequences and their advantages, disadvantages and usefullness in the imaging of this complex anatomical region are addressed. Finally, cutting-edge techniques are discussed, including susceptibility weighted MRI, ultrashort echo time MRI, zero echo time MRI and a deep learning-based multiparametric MRI technique named `synthetic CT,' creating CT-like images without ionizing radiaton.