LMLieve Morbée

Lieve Morbée

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lieve Morbée has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bone Magnetic Resonance Imaging: From Conventional Methods to AI ‐Driven Solutions

    by Yi He, Rahman Ud Din, Lieve Morbée, Haisheng Yang

    With global population aging and increased life expectancy, bone diseases affect a substantial proportion of individuals worldwide, imposing a significant socioeconomic burden. Although X‐ray‐based imaging techniques remain the clinical standard for bone assessment, they are constrained by ionizing radiation exposure and poor soft‐tissue contrast. Magnetic resonance imaging (MRI) has emerged as a promising radiation‐free alternative, enabling detailed evaluation of tissue properties, bone microstructure, functional status, and pathological changes. However, the intrinsically low proton density and rapid transverse relaxation of bone tissue present fundamental technical challenges. Over the past decades, numerous MRI‐based techniques have been developed to address these limitations. Yet, the literature remains fragmented. This review synthesizes recent advancements in bone MRI, covering conventional sequences (e.g., T1‐weighted and T2‐weighted imaging), advanced sequences (e.g., ultrashort echo time and zero echo time), metabolic imaging sequences (e.g., magnetic resonance spectroscopy and dynamic contrast‐enhanced MRI), and hardware innovations (e.g., ultra‐high‐field MRI at 7/14 T). The strengths and limitations of these techniques are discussed, and their roles are highlighted in early diagnosis, therapeutic monitoring, and management of diverse bone disorders, including osteoporosis, osteoarthritis, osteosarcoma, and osteonecrosis. Furthermore, we explore how artificial intelligence, particularly deep learning models, enhances MRI capabilities by reducing scanning time, adding synthetic contrasts like synthetic CT, improving image quality, and increasing diagnostic accuracy. Finally, we outline challenges and future directions to advance bone assessment. This comprehensive review may guide preclinical research and accelerate clinical translation of bone MRI techniques, ultimately improving musculoskeletal disease management. Level of Evidence: 4. Technical Efficacy: Stage 2.


  • Open Access

    Mineralized tissue visualization with MRI: Practical insights and recommendations for optimized clinical applications

    by Pedro Augusto Gondim Teixeira, Hippolyte Kessler, Lieve Morbée, Nicolas Douis, Fatma Boubaker, Romain Gillet, Alain Blum


  • Common incidental findings on sacroiliac joint MRI: Added value of MRI-based synthetic CT

    by Lieve Morbée, Elke Vereecke, Frederiek Laloo, Min Chen, Nele Herregods, Lennart B.O. Jans


  • Open Access

    Intraspinal Azygos Vein

    by Joanna Knapik, Elke Vereecke, Lieve Morbée

    Teaching Point: Intraspinal azygos vein is an extremely rare anatomical variant; knowledge is important for correct imaging interpretation.

  • Open Access

    Characterizing Scatter Correction Software of 5 Mobile Radiography Units

    by Tim Msc Gossye, Dimitri Msc Buytaert, Peter V. Smeets, Lieve Morbée, Elke Vereecke, Eric Achten, Klaus Bacher

    Objectives: Bedside radiographs are usually obtained gridless, without a physical scatter correction grid because of several limitations. Therefore, multiple manufacturers of mobile radiography systems provide the possibility to apply scatter correction software (SC SW) on those images. The purpose of this study was to characterize different series of radiographs—gridless, SC SW, and physical grid—with an image quality assessment algorithm (IQAA). Furthermore, we investigated the potential dose reduction and the correlation between the output of the IQAA and the human observers. Materials and Methods: We obtained different series of radiographs with an anthropomorphic phantom (multipurpose chest phantom N1 “Lungman,” Kyoto Kagaku, Kyoto, Japan). All radiographs were obtained with flat-panel detectors of 5 different manufacturers in a wall bucky system. An IQAA to analyze the radiographs was implemented in our department but was originally developed by the research group of the Duke University Medical Center. Seven physical quantities were calculated by the IQAA: rib-lung contrast (RLcontrast ), subdiaphragm-lung contrast (SLcontrast ), lung detail (Ldetail ), mediastinum detail (Mdetail ), lung noise (Lnoise ), mediastinum noise (Mnoise ), and rib-lung sharpness (RLsharpness ). In a proof of concept, the results of the IQAA were validated by 3 experienced radiologists. Results: Regression coefficients (b) of the linear regression model indicate that the human observer results correlate well with the IQAA (b ≥ 0.89, R 2 ≥ 0.83). All manufacturers have SC SW that increases the 7 physical quantities of the gridless images. However, several manufacturers have SC SW that increases the physical metrics to the same level as the physical grid images. The SC SW radiographs obtained with a reduced tube load have an increased level of contrast, detail, sharpness, and noise compared with the gridless images obtained with the higher tube load. Conclusions: We have proven in a proof of concept that the originally developed IQAA can be used to characterize different series of images of different manufacturers. Based on the physical quantities, SC SW increases the contrast, detail, sharpness, and noise. The experimental results in this study assume a patient dose reduction could be possible when SC SW is applied.


  • Open Access

    MRI-based synthetic CT of the hip: can it be an alternative to conventional CT in the evaluation of osseous morphology?

    by Lieve Morbée, Min Chen, Thomas Van Den Berghe, Eva Schiettecatte, Robert Gosselin, Nele Herregods, Lennart B. O. Jans

    Objectives MRI is the gold standard for soft tissue evaluation in the hip joint. However, CT is superior to MRI in providing clear visualization of bony morphology. The aim of this study is to test the equivalency of MRI-based synthetic CT to conventional CT in quantitatively assessing bony morphology of the hip. Materials and methods A prospective study was performed. Adult patients who underwent MRI and CT of the hips were included. Synthetic CT images were generated from MRI using a deep learning–based image synthesis method. Two readers independently performed clinically relevant measurements for hip morphology, including anterior and posterior acetabular sector angle, acetabular version angle, joint space width, lateral center–edge angle, sharp angle, alpha angle, and femoral head-neck offset on synthetic CT and CT. Inter-method, inter-reader, and intra-reader reliability and agreement were assessed using calculations of intraclass correlation coefficient, standard error of measurement, and smallest detectable change. The equivalency among CT and synthetic CT was evaluated using equivalency statistical testing. Results Fifty-four hips from twenty-seven participants were included. There was no reported hip pathology in the subjects. The observed agreement based on reliability and agreement parameters indicated a strong degree of concordance between CT and synthetic CT. Equivalence statistical testing showed that all synthetic CT measurements are equivalent to the CT measurements at the considered margins. Conclusion In healthy individuals, we demonstrated equivalency of MRI-based synthetic CT to conventional CT for the quantitative evaluation of osseous hip morphology, thus obviating the radiation exposure of a pelvic CT examination. Key Points •MRI-based synthetic CT images can be generated from MRI using a deep learning–based image synthesis method. •MRI-based synthetic CT is equivalent to CT in the quantitative assessment of bony hip morphology in healthy individuals. •MRI-based synthetic CT is promising for use in preoperative diagnosis and surgery planning.


  • Open Access

    MR Imaging of the Pelvic Bones: The Current and Cutting-Edge Techniques

    by Lieve Morbee, Elke Vereecke, Frederiek Laloo, Min Chen, Nele Herregods, Lennart Jans

    This review presents an overview of the spectrum of the current and cutting-edge MRI techniques for pelvic bone imaging in clinical practice. The current MRI sequences and their advantages, disadvantages and usefullness in the imaging of this complex anatomical region are addressed. Finally, cutting-edge techniques are discussed, including susceptibility weighted MRI, ultrashort echo time MRI, zero echo time MRI and a deep learning-based multiparametric MRI technique named `synthetic CT,' creating CT-like images without ionizing radiaton.