Hak Yi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hak Yi has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Kwan Kyu Park
Department of Convergence Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea
4 shared publications - Changwon Kim
School of Mechanical Engineering, Pukyong National University, Busan 48513, Republic of Korea
3 shared publications - Hee-Seon Seo
Agency for Defense Development, Changwon 51678, Republic of Korea
3 shared publications - Hwijin Park
Depart of Mechanical Engineering, Kyungpook National University, Daegu, Republic of Korea
3 shared publications - Kiyoung Kim
Department of Medical Robot, Korea Institute of Machinery and Materials, Daegu, Republic of Korea
3 shared publications - Sang-Ryong Lee
Kyungpook National University
3 shared publications
Latest Publications
- 9 April 2026
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 40 (4) , 3023-3031
Spatial representation of human poses and object locations via AI-driven LiDAR-vision image fusion
- 9 April 2026
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 40 (4) , 3023-3031
Spatial representation of human poses and object locations via AI-driven LiDAR-vision image fusion
- Open Access
Active-Assistive Control Based on Dynamic Moving Window for Trajectory Tracking of an Upper Limb Exoskeleton in Assisted Rehabilitation
Rehabilitation robotics faces the challenges of aligning engineering design with patient-specific needs. Most existing controllers in rehabilitation robots often constrain motion to fixed paths or provide only passive guidance, limiting user engagement and adaptability. This study proposes a novel active-assistive mode controller that integrates a virtual tunnel-based force generation mechanism with a dynamic moving-window technique for tracking activities of daily living (ADL) trajectories. Unlike conventional impedance controllers, the proposed method dynamically adjusts the virtual tunnel in real time, permitting voluntary upper-limb movement within a safe operational range while preventing excessive deviation. The system was implemented on a wearable two-degree-of-freedom (DOF) upper-limb exoskeleton equipped with drive and integrated sensor units. Experimental results demonstrated that decreasing the guidance force () increased tracking errors, from at 100% to at 30% , indicating greater voluntary participant motion. Peak actuator torques correspondingly decreased from 14.75 to 13.43 Nm (elbow) and from 4.14 to 2.48 Nm (wrist), confirming the controller’s capability to modulate robotic assistance according to user effort. Tests with 30 healthy participants demonstrated the effectiveness of guidance along predefined ADL trajectories, validating the controller’s potential for patient-centered rehabilitation.Open AccessActive-Assistive Control Based on Dynamic Moving Window for Trajectory Tracking of an Upper Limb Exoskeleton in Assisted Rehabilitation
Rehabilitation robotics faces the challenges of aligning engineering design with patient-specific needs. Most existing controllers in rehabilitation robots often constrain motion to fixed paths or provide only passive guidance, limiting user engagement and adaptability. This study proposes a novel active-assistive mode controller that integrates a virtual tunnel-based force generation mechanism with a dynamic moving-window technique for tracking activities of daily living (ADL) trajectories. Unlike conventional impedance controllers, the proposed method dynamically adjusts the virtual tunnel in real time, permitting voluntary upper-limb movement within a safe operational range while preventing excessive deviation. The system was implemented on a wearable two-degree-of-freedom (DOF) upper-limb exoskeleton equipped with drive and integrated sensor units. Experimental results demonstrated that decreasing the guidance force () increased tracking errors, from at 100% to at 30% , indicating greater voluntary participant motion. Peak actuator torques correspondingly decreased from 14.75 to 13.43 Nm (elbow) and from 4.14 to 2.48 Nm (wrist), confirming the controller’s capability to modulate robotic assistance according to user effort. Tests with 30 healthy participants demonstrated the effectiveness of guidance along predefined ADL trajectories, validating the controller’s potential for patient-centered rehabilitation. - 12 January 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (3) , 1163-1181
Development of Variable-Stiffness Knee Prosthesis with Agonist-Antagonist Mechanism for Lower-Limb Amputees
- 12 January 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (3) , 1163-1181
Development of Variable-Stiffness Knee Prosthesis with Agonist-Antagonist Mechanism for Lower-Limb Amputees
- Open Access
- 1 January 2026
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 23 (1)
Patient-specific upper-limb robotic replica integrating joint rigidity and physiological tremor
The implementation of an upper-limb rehabilitation simulator replicating patient-specific physical characteristics has garnered increasing interest as an effective alternative to human subjects for medical training and research. However, human upper-limb motion involves complex multi-joint coordination, whereas most existing patient simulators reproduce simplified mechanical properties of individual joints and often fail to mimic critical pathological characteristics, such as rigidity and physiological tremors. This study addresses these limitations by proposing a novel simulator that incorporates both compound joint coordination and patient-specific symptoms (e.g. lead-pipe rigidity and physiological tremors). A motion control system based on a linear quadratic regulator was designed, with patient-specific reference torques derived from adult male motion-capture data. The tremor parameters were selected within the range reported in neurophysiological literature, and rigidity was implemented based on spasticity-inspired torque models. The proposed controller achieved torque-tracking errors below 3%, while reproducing clinically relevant peak torque levels of 18–20 Nm at the shoulder and 3–7 Nm at the elbow under manual muscle testing–grade scaling. The experimental evaluations across rigidity levels highlighted the reliability and effectiveness of the proposed simulator in accurately mimicking patient characteristics, making it a practical alternative for patients in rehabilitation training. Additionally, a clinical similarity survey was conducted with eight rehabilitation specialists and 10 students following a standardized, blinded protocol, yielding a mean rating of 9.33 ± 0.72 and a significant group effect (analysis of variance F ( 2 , 57 ) = 12.83 , p < 0.001 ). To the best of our knowledge, this study is the first to combine multi-joint coordination with the simultaneous reproduction of rigidity and physiological tremors in a two-degree-of-freedom upper-limb robotic replica, demonstrating the novelty and practical value of the approach.
- 1 January 2026
- Published by SAGE Publications in International Journal of Advanced Robotic Systems
- Vol. 23 (1)
Open AccessPatient-specific upper-limb robotic replica integrating joint rigidity and physiological tremor
The implementation of an upper-limb rehabilitation simulator replicating patient-specific physical characteristics has garnered increasing interest as an effective alternative to human subjects for medical training and research. However, human upper-limb motion involves complex multi-joint coordination, whereas most existing patient simulators reproduce simplified mechanical properties of individual joints and often fail to mimic critical pathological characteristics, such as rigidity and physiological tremors. This study addresses these limitations by proposing a novel simulator that incorporates both compound joint coordination and patient-specific symptoms (e.g. lead-pipe rigidity and physiological tremors). A motion control system based on a linear quadratic regulator was designed, with patient-specific reference torques derived from adult male motion-capture data. The tremor parameters were selected within the range reported in neurophysiological literature, and rigidity was implemented based on spasticity-inspired torque models. The proposed controller achieved torque-tracking errors below 3%, while reproducing clinically relevant peak torque levels of 18–20 Nm at the shoulder and 3–7 Nm at the elbow under manual muscle testing–grade scaling. The experimental evaluations across rigidity levels highlighted the reliability and effectiveness of the proposed simulator in accurately mimicking patient characteristics, making it a practical alternative for patients in rehabilitation training. Additionally, a clinical similarity survey was conducted with eight rehabilitation specialists and 10 students following a standardized, blinded protocol, yielding a mean rating of 9.33 ± 0.72 and a significant group effect (analysis of variance F ( 2 , 57 ) = 12.83 , p < 0.001 ). To the best of our knowledge, this study is the first to combine multi-joint coordination with the simultaneous reproduction of rigidity and physiological tremors in a two-degree-of-freedom upper-limb robotic replica, demonstrating the novelty and practical value of the approach.
- 12 June 2025
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 26 (11) , 2889-2901
Optimization of a 5-Bar Linkage Mechanism Knee Prosthesis for Lower-Limb Amputees
- 12 June 2025
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 26 (11) , 2889-2901
Optimization of a 5-Bar Linkage Mechanism Knee Prosthesis for Lower-Limb Amputees
- 1 September 2024
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 41 (9) , 707-711
A Study on the Measurement of Ship Hull Paint Thickness Using Collaborative Robots and Depth Cameras
This study presents a method for inspecting ship block wall painting using a cooperative robot. The robot used in this study is a representative example of a human-collaborative robot system. The end-effector of the robot is equipped with a depth camera, designed in an eye-in style. The camera is used to measure and evaluate the thickness of the paint applied to the iron plate, simulating the conditions of ship block wall painting. To improve the accuracy of the recognition, an object detection algorithm with rapid computation and high accuracy was utilized. The algorithm was used to identify and outline the paint areas using the Canny edge algorithm. The proposed method successfully demonstrated the precision of paint area recognition by clearly identifying the center point and outline of the areas. Comparing the paint thickness measurements with laser distance measurements confirmed the effectiveness of the proposed method.
- 1 September 2024
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 41 (9) , 707-711
A Study on the Measurement of Ship Hull Paint Thickness Using Collaborative Robots and Depth Cameras
This study presents a method for inspecting ship block wall painting using a cooperative robot. The robot used in this study is a representative example of a human-collaborative robot system. The end-effector of the robot is equipped with a depth camera, designed in an eye-in style. The camera is used to measure and evaluate the thickness of the paint applied to the iron plate, simulating the conditions of ship block wall painting. To improve the accuracy of the recognition, an object detection algorithm with rapid computation and high accuracy was utilized. The algorithm was used to identify and outline the paint areas using the Canny edge algorithm. The proposed method successfully demonstrated the precision of paint area recognition by clearly identifying the center point and outline of the areas. Comparing the paint thickness measurements with laser distance measurements confirmed the effectiveness of the proposed method.
- 1 August 2024
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 41 (8) , 591-596
Passive Mode Control of 2 DOF Wearable Upper-limb Rehabilitation Robot
People with hemiplegia require ongoing rehabilitation exercises to regain function in their upper limbs. However, due to the increasing number of elderly and disabled people, the number of rehabilitation professionals is insufficient. As a solution to this problem, researchers have been exploring various upper limb rehabilitation exercise robots. Unfortunately, these robots are often large and heavy, making them cumbersome to wear and use. The proposed exoskeleton rehabilitation robot consists of two robotic modules: an elbow module (1 DOF) and a wrist module (1 DOF). In order to analyze the robot
- 1 August 2024
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 41 (8) , 591-596
Passive Mode Control of 2 DOF Wearable Upper-limb Rehabilitation Robot
People with hemiplegia require ongoing rehabilitation exercises to regain function in their upper limbs. However, due to the increasing number of elderly and disabled people, the number of rehabilitation professionals is insufficient. As a solution to this problem, researchers have been exploring various upper limb rehabilitation exercise robots. Unfortunately, these robots are often large and heavy, making them cumbersome to wear and use. The proposed exoskeleton rehabilitation robot consists of two robotic modules: an elbow module (1 DOF) and a wrist module (1 DOF). In order to analyze the robot
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 2534-2544
A Novel Design of Unpowered Exoskeleton for Loaded Walking Using Only Hip Abduction Torque
An upper extremity device can help humans when they are walking with a load. However, when using such a device that does not have lower limb parts, the upper and lower bodies of the wearer should support the weight of the load. To solve this limitation, this study proposes an unpowered wearable exoskeleton that can reduce the weights of loads felt by the wearer when they are walking. Using supporting force, trunk extension, and loaded walking tests, for a load weight of 12 kgf, the exoskeleton could reduce the weight transmitted to the wearer by 7 kgf, decrease the human trunk extension angle by up to 1.8° compared to that in case of an upper extremity device, and lower the net metabolic rate of the wearer by up to 47.41% during loaded walking. Especially, such reductions in the net metabolic rate have not been reported to date. These three primary results indicate that the exoskeleton in this article can be used to augment the human load-carrying capability and solve the structural problems associated with the use of an upper extremity device. Furthermore, because the exoskeleton requires no power sources and actuators, it is energy-efficient and can be used in the water environments. This exoskeleton is economical owing to its simple structure. Moreover, the model verified in this paper can be utilized in other similar systems having a spring mechanism to optimize the systems.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 2534-2544
A Novel Design of Unpowered Exoskeleton for Loaded Walking Using Only Hip Abduction Torque
An upper extremity device can help humans when they are walking with a load. However, when using such a device that does not have lower limb parts, the upper and lower bodies of the wearer should support the weight of the load. To solve this limitation, this study proposes an unpowered wearable exoskeleton that can reduce the weights of loads felt by the wearer when they are walking. Using supporting force, trunk extension, and loaded walking tests, for a load weight of 12 kgf, the exoskeleton could reduce the weight transmitted to the wearer by 7 kgf, decrease the human trunk extension angle by up to 1.8° compared to that in case of an upper extremity device, and lower the net metabolic rate of the wearer by up to 47.41% during loaded walking. Especially, such reductions in the net metabolic rate have not been reported to date. These three primary results indicate that the exoskeleton in this article can be used to augment the human load-carrying capability and solve the structural problems associated with the use of an upper extremity device. Furthermore, because the exoskeleton requires no power sources and actuators, it is energy-efficient and can be used in the water environments. This exoskeleton is economical owing to its simple structure. Moreover, the model verified in this paper can be utilized in other similar systems having a spring mechanism to optimize the systems.
- 31 May 2024
- Published by The Korea Robotics Society in Journal of Korea Robotics Society
- Vol. 19 (2) , 159-168
Development of an Electronically Controlled Knee-Type Prosthetic Leg with a 4-Bar Linkage Structure for Lower Limb Amputee
- 31 May 2024
- Published by The Korea Robotics Society in Journal of Korea Robotics Society
- Vol. 19 (2) , 159-168
Development of an Electronically Controlled Knee-Type Prosthetic Leg with a 4-Bar Linkage Structure for Lower Limb Amputee
- Open Access
Development of an In-Pipe Inspection Robot for Large-Diameter Water Pipes
This paper describes the development of an in-pipe inspection robot system designed for large-diameter water pipes. The robot is equipped with a Magnetic Flux Leakage (MFL) sensor module. The robot system is intended for pipes with diameters ranging from 900 mm to 1200 mm. The structure of the in-pipe inspection robot consists of the front and rear driving parts, with the inspection module located centrally. The robot is powered by 22 motors, including eight wheels with motors positioned at both the bottom and the top for propulsion. To ensure that the robot’s center aligns with that of the pipeline during operation, lifting units have been incorporated. The robot is equipped with cameras and LiDAR sensors at the front and rear to monitor the internal environment of the pipeline. Pipeline inspection is conducted using the MFL inspection modules, and the robot’s driving mechanism is designed to execute spiral maneuvers while maintaining contact with the pipeline surface during rotation. The in-pipe inspection robot is configured with wireless communication modules and batteries, allowing for wireless operation. Following its development, the inspection robot underwent driving experiments in actual pipelines to validate its performance. The field test bed used for these experiments is approximately 1 km in length. Results from the driving experiments on the field test bed confirmed the robot’s ability to navigate various curvatures and obstacles within the pipeline. It is posited that the use of the developed in-pipe inspection robot can reduce economic costs and enhance the safety of inspectors when examining aging pipes.
Open AccessDevelopment of an In-Pipe Inspection Robot for Large-Diameter Water Pipes
This paper describes the development of an in-pipe inspection robot system designed for large-diameter water pipes. The robot is equipped with a Magnetic Flux Leakage (MFL) sensor module. The robot system is intended for pipes with diameters ranging from 900 mm to 1200 mm. The structure of the in-pipe inspection robot consists of the front and rear driving parts, with the inspection module located centrally. The robot is powered by 22 motors, including eight wheels with motors positioned at both the bottom and the top for propulsion. To ensure that the robot’s center aligns with that of the pipeline during operation, lifting units have been incorporated. The robot is equipped with cameras and LiDAR sensors at the front and rear to monitor the internal environment of the pipeline. Pipeline inspection is conducted using the MFL inspection modules, and the robot’s driving mechanism is designed to execute spiral maneuvers while maintaining contact with the pipeline surface during rotation. The in-pipe inspection robot is configured with wireless communication modules and batteries, allowing for wireless operation. Following its development, the inspection robot underwent driving experiments in actual pipelines to validate its performance. The field test bed used for these experiments is approximately 1 km in length. Results from the driving experiments on the field test bed confirmed the robot’s ability to navigate various curvatures and obstacles within the pipeline. It is posited that the use of the developed in-pipe inspection robot can reduce economic costs and enhance the safety of inspectors when examining aging pipes.