Carmel Mary Moran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carmel Mary Moran has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
Scott Inglis
Medical Physics, NHS Lothian
5 shared publications- Vassilis Sboros
School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom
5 shared publications - Adrian Thomson
Institute for Neuroscience and Cardiovascular Research, The University of Edinburgh, United Kingdom
4 shared publications - Helen Mulvana
James Watt School of Engineering, University of Glasgow , Glasgow, G12 8QQ
3 shared publications Stephen D. Pye
University-BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, Edinburgh EH16 4TJ, UK
3 shared publicationsAdrian J. W. Thomson
Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 8, 1918432
Beyond segmentation accuracy: understanding model reliability and failure modes in ultrasound image analysis
Segmentation of ultrasound images is complex, and although deep learning has improved automation, trust remains limited, restricting adoption. Interpretability methods may help reveal model behaviours and failure modes, supporting more trustworthy AI systems. A U-Net with a ResNet-18 backbone was trained to segment pipes in images of the Edinburgh Pipe Phantom acquired using ten ultrasound probes ( N = 162). Performance was assessed using five-fold cross-validation. Predictive entropy and variance across 20 Monte Carlo dropout forward passes were used as approximations of data-related and model-related uncertainty. Calibration was assessed using the Brier score and expected calibration error (ECE). Input-gradient saliency and Grad-CAM maps from four encoder stages and the final decoder block were evaluated. For exploratory prospective quality control, complete empty-mask failures were assessed directly from model output, while non-empty predictions were classified retrospectively using reference-based performance criteria and reference-free uncertainty and morphological features were evaluated as candidate indicators. The model achieved a Dice score of 0.81 ± 0.03 and an HD95 of 11.98 ± 3.39. Seven segmentation errors were identified: three complete failures in which no foreground mask was predicted and four non-empty predictions in which the incorrect pipe was segmented. Dice score was associated with the Brier score (Spearman ρ = −0.96) and ECE ( ρ = −0.72), whereas predictive entropy and Monte Carlo dropout variance showed weak associations with segmentation performance (| ρ | < 0.4). In selected failure examples, uncertainty and activation sometimes overlapped the reference pipe region despite incorrect segmentation. Complete empty-mask failures were deterministically identifiable from the model output, whereas the evaluated reference-free indicators showed limited ability to identify poor-quality non-empty segmentations. Within this phantom dataset and model configuration, calibration metrics were more closely associated with segmentation quality than the evaluated uncertainty approximations. Attention and uncertainty maps provided complementary descriptive information about selected errors, but indicated spatial sensitivity rather than causal model reasoning. Simple output checks enabled deterministic identification of complete segmentation failures; however, the evaluated reference-free indicators were insufficient for validated prospective identification of subtler non-empty errors. These findings support multimodal model evaluation for EPP segmentation while emphasising the need for validation on independent datasets, devices and architectures in future studies.
- 23 September 2026
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 8, 1918432
Open AccessBeyond segmentation accuracy: understanding model reliability and failure modes in ultrasound image analysis
Segmentation of ultrasound images is complex, and although deep learning has improved automation, trust remains limited, restricting adoption. Interpretability methods may help reveal model behaviours and failure modes, supporting more trustworthy AI systems. A U-Net with a ResNet-18 backbone was trained to segment pipes in images of the Edinburgh Pipe Phantom acquired using ten ultrasound probes ( N = 162). Performance was assessed using five-fold cross-validation. Predictive entropy and variance across 20 Monte Carlo dropout forward passes were used as approximations of data-related and model-related uncertainty. Calibration was assessed using the Brier score and expected calibration error (ECE). Input-gradient saliency and Grad-CAM maps from four encoder stages and the final decoder block were evaluated. For exploratory prospective quality control, complete empty-mask failures were assessed directly from model output, while non-empty predictions were classified retrospectively using reference-based performance criteria and reference-free uncertainty and morphological features were evaluated as candidate indicators. The model achieved a Dice score of 0.81 ± 0.03 and an HD95 of 11.98 ± 3.39. Seven segmentation errors were identified: three complete failures in which no foreground mask was predicted and four non-empty predictions in which the incorrect pipe was segmented. Dice score was associated with the Brier score (Spearman ρ = −0.96) and ECE ( ρ = −0.72), whereas predictive entropy and Monte Carlo dropout variance showed weak associations with segmentation performance (| ρ | < 0.4). In selected failure examples, uncertainty and activation sometimes overlapped the reference pipe region despite incorrect segmentation. Complete empty-mask failures were deterministically identifiable from the model output, whereas the evaluated reference-free indicators showed limited ability to identify poor-quality non-empty segmentations. Within this phantom dataset and model configuration, calibration metrics were more closely associated with segmentation quality than the evaluated uncertainty approximations. Attention and uncertainty maps provided complementary descriptive information about selected errors, but indicated spatial sensitivity rather than causal model reasoning. Simple output checks enabled deterministic identification of complete segmentation failures; however, the evaluated reference-free indicators were insufficient for validated prospective identification of subtler non-empty errors. These findings support multimodal model evaluation for EPP segmentation while emphasising the need for validation on independent datasets, devices and architectures in future studies.
- Open Access
- 2 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108144
Acoustic and mechanical characterisation of a 3D-printable transparent vessel-mimicking material for pre-clinical imaging: comparison with ex-vivo vessels and established clinically-relevant materials
- 2 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108144
Open AccessAcoustic and mechanical characterisation of a 3D-printable transparent vessel-mimicking material for pre-clinical imaging: comparison with ex-vivo vessels and established clinically-relevant materials
- Open Access
- 4 May 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (8) , 1178-1182
An Assessment of the Imaging Performance of Hand-Held Ultrasound Scanners Using the Edinburgh Pipe Phantom
- 4 May 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (8) , 1178-1182
Open AccessAn Assessment of the Imaging Performance of Hand-Held Ultrasound Scanners Using the Edinburgh Pipe Phantom
- Open Access
- 12 December 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 1099233
Editorial: Small animal imaging: Technological and methodological advances to improve the translational power
Editorial: Small animal imaging: Technological and methodological advances to improve the translational power
- 12 December 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 1099233
Open AccessEditorial: Small animal imaging: Technological and methodological advances to improve the translational power
Editorial: Small animal imaging: Technological and methodological advances to improve the translational power
- 10 October 2022
- Published by Elsevier in Nanomedicine: Nanotechnology, Biology and Medicine
- Vol. 46, 102611
Ultrastable shelled PFC nanobubbles: A platform for ultrasound-assisted diagnostics, and therapy
- 10 October 2022
- Published by Elsevier in Nanomedicine: Nanotechnology, Biology and Medicine
- Vol. 46, 102611
Ultrastable shelled PFC nanobubbles: A platform for ultrasound-assisted diagnostics, and therapy
- Open Access
- 15 September 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2285-2297
A Comparison of the Sensitivity of Contrast-Specific Imaging Modes on Clinical and Preclinical Ultrasound Scanners
Ultrasonic contrast agents are used routinely to aid clinical diagnosis. All premium- and mid-range scanners utilise contrast-specific imaging techniques to preferentially isolate and display the nonlinear signals generated from the microbubbles when insonated with a series of ultrasound pulses. In this manuscript the abilities of four premium ultrasound scanners to detect and display the ultrasound signal from two commercially available contrast agents—SonoVue and DEFINITY®—are compared. A flow phantom was built using tubes with internal diameters of 1.6 mm and 3.2 mm, suspended at depths of 1, 5 and 8 cm and embedded in tissue-mimicking material. Dilute solutions of SonoVue and DEFINITY® were pumped through the phantom at 0.25 mL/s and 1.5 mL/s. Four transducers were used to scan the tubes—a GE Logiq E9 (C2-9) curvilinear probe, a Philips iU22 L9-3 linear array probe, an Esaote MyLab Twice linear array LA523 (4–13 MHz) and a Fujifilm VisualSonics Vevo3100 MX250 (15–30 MHz) linear array probe. We defined a new parameter to compare the ability of the ultrasound scanners to display the contrast enhancement. This was defined as the ratio of grey-scale intensity ratio in contrast-specific imaging mode relative to the B-mode intensity from the same region-of-interest within the corresponding B-mode image. The study demonstrated that the flow rates used in this study had no effect on the contrast-specific imaging mode to B-mode (CSIM-BM) ratio for the three clinical scanners studied, with SonoVue demonstrating broadly similar CSIM-BM ratios across all 3 clinical scanners. DEFINITY® also displayed similar results to SonoVue except when insonated with the Esaote MyLab Twice LA523 transducer, where it demonstrated significantly higher CSIM-BM ratios at superficial depths.
- 15 September 2022
- Published by MDPI AG in Tomography
- Vol. 8 (5) , 2285-2297
Open AccessA Comparison of the Sensitivity of Contrast-Specific Imaging Modes on Clinical and Preclinical Ultrasound Scanners
Ultrasonic contrast agents are used routinely to aid clinical diagnosis. All premium- and mid-range scanners utilise contrast-specific imaging techniques to preferentially isolate and display the nonlinear signals generated from the microbubbles when insonated with a series of ultrasound pulses. In this manuscript the abilities of four premium ultrasound scanners to detect and display the ultrasound signal from two commercially available contrast agents—SonoVue and DEFINITY®—are compared. A flow phantom was built using tubes with internal diameters of 1.6 mm and 3.2 mm, suspended at depths of 1, 5 and 8 cm and embedded in tissue-mimicking material. Dilute solutions of SonoVue and DEFINITY® were pumped through the phantom at 0.25 mL/s and 1.5 mL/s. Four transducers were used to scan the tubes—a GE Logiq E9 (C2-9) curvilinear probe, a Philips iU22 L9-3 linear array probe, an Esaote MyLab Twice linear array LA523 (4–13 MHz) and a Fujifilm VisualSonics Vevo3100 MX250 (15–30 MHz) linear array probe. We defined a new parameter to compare the ability of the ultrasound scanners to display the contrast enhancement. This was defined as the ratio of grey-scale intensity ratio in contrast-specific imaging mode relative to the B-mode intensity from the same region-of-interest within the corresponding B-mode image. The study demonstrated that the flow rates used in this study had no effect on the contrast-specific imaging mode to B-mode (CSIM-BM) ratio for the three clinical scanners studied, with SonoVue demonstrating broadly similar CSIM-BM ratios across all 3 clinical scanners. DEFINITY® also displayed similar results to SonoVue except when insonated with the Esaote MyLab Twice LA523 transducer, where it demonstrated significantly higher CSIM-BM ratios at superficial depths.
- Open Access
- 1 July 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20211128
Modelling of magnetic microbubbles to evaluate contrast enhanced magnetomotive ultrasound in lymph nodes – a pre-clinical study
Objectives: Despite advances in MRI the detection and characterisation of lymph nodes in rectal cancer remains complex, especially when assessing the response to neoadjuvant treatment. An alternative approach is functional imaging, previously shown to aid characterisation of cancer tissues. We report proof of concept of the novel technique Contrast-Enhanced Magneto-Motive Ultrasound (CE-MMUS) to recover information relating to local perfusion and lymphatic drainage, and interrogate tissue mechanical properties through magnetically induced deformations.Methods: The feasibility of the proposed application was explored using a combination of experimental animal and phantom ultrasound imaging, along with finite element analysis. First, contrast-enhanced ultrasound imaging on one wild type mouse recorded lymphatic drainage of magnetic microbubbles after bolus injection. Second, tissue phantoms were imaged using MMUS to illustrate the force- and elasticity dependence of the magnetomotion. Third, the magnetomechanical interactions of a magnetic microbubble with an elastic solid were simulated using finite element software.Results: Accumulation of magnetic microbubbles in the inguinal lymph node was verified using contrast enhanced ultrasound, with peak enhancement occurring 3.7 s post-injection. The magnetic microbubble gave rise to displacements depending on force, elasticity, and bubble radius, indicating an inverse relation between displacement and the latter two.Conclusion: Combining magnetic microbubbles with MMUS could harness the advantages of both techniques, to provide perfusion information, robust lymph node delineation and characterisation based on mechanical properties.Advances in knowledge: (a) Lymphatic drainage of magnetic microbubbles visualised using contrast-enhanced ultrasound imaging and (b) magnetomechanical interactions between such bubbles and surrounding tissue could both contribute to (c) robust detection and characterisation of lymph nodes.
- 1 July 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1135) , 20211128
Open AccessModelling of magnetic microbubbles to evaluate contrast enhanced magnetomotive ultrasound in lymph nodes – a pre-clinical study
Objectives: Despite advances in MRI the detection and characterisation of lymph nodes in rectal cancer remains complex, especially when assessing the response to neoadjuvant treatment. An alternative approach is functional imaging, previously shown to aid characterisation of cancer tissues. We report proof of concept of the novel technique Contrast-Enhanced Magneto-Motive Ultrasound (CE-MMUS) to recover information relating to local perfusion and lymphatic drainage, and interrogate tissue mechanical properties through magnetically induced deformations.Methods: The feasibility of the proposed application was explored using a combination of experimental animal and phantom ultrasound imaging, along with finite element analysis. First, contrast-enhanced ultrasound imaging on one wild type mouse recorded lymphatic drainage of magnetic microbubbles after bolus injection. Second, tissue phantoms were imaged using MMUS to illustrate the force- and elasticity dependence of the magnetomotion. Third, the magnetomechanical interactions of a magnetic microbubble with an elastic solid were simulated using finite element software.Results: Accumulation of magnetic microbubbles in the inguinal lymph node was verified using contrast enhanced ultrasound, with peak enhancement occurring 3.7 s post-injection. The magnetic microbubble gave rise to displacements depending on force, elasticity, and bubble radius, indicating an inverse relation between displacement and the latter two.Conclusion: Combining magnetic microbubbles with MMUS could harness the advantages of both techniques, to provide perfusion information, robust lymph node delineation and characterisation based on mechanical properties.Advances in knowledge: (a) Lymphatic drainage of magnetic microbubbles visualised using contrast-enhanced ultrasound imaging and (b) magnetomechanical interactions between such bubbles and surrounding tissue could both contribute to (c) robust detection and characterisation of lymph nodes.
- Open Access
- 26 May 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
The Imaging Performance of Preclinical Ultrasound Scanners Using the Edinburgh Pipe Phantom
The greyscale imaging performance of a total of 17 preclinical transducer/scanner combinations were measured over a period of 10 years. These comprised nine single element transducers and eight array transducers with nominal central frequencies ranging between 15 and 55 MHz, and were from four commercially-available preclinical ultrasound scanners. Performance was assessed using a single figure of merit, the resolution integral, using measurements acquired from images of a test-object, the Edinburgh Pipe Phantom. Two further parameters were derived from the resolution integral: characteristic resolution and depth-of-field. Our results demonstrate that 1) resolution integral values of the array transducers were greater than single-element transducers, and 2) the array transducers demonstrated greater depths of field than the single-element transducers of the same nominal frequency. Moreover we demonstrate that use of this single figure-of-merit enabled identification and quantification of changes in imaging performance of preclinical transducers over a 10-years period.
- 26 May 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessThe Imaging Performance of Preclinical Ultrasound Scanners Using the Edinburgh Pipe Phantom
The greyscale imaging performance of a total of 17 preclinical transducer/scanner combinations were measured over a period of 10 years. These comprised nine single element transducers and eight array transducers with nominal central frequencies ranging between 15 and 55 MHz, and were from four commercially-available preclinical ultrasound scanners. Performance was assessed using a single figure of merit, the resolution integral, using measurements acquired from images of a test-object, the Edinburgh Pipe Phantom. Two further parameters were derived from the resolution integral: characteristic resolution and depth-of-field. Our results demonstrate that 1) resolution integral values of the array transducers were greater than single-element transducers, and 2) the array transducers demonstrated greater depths of field than the single-element transducers of the same nominal frequency. Moreover we demonstrate that use of this single figure-of-merit enabled identification and quantification of changes in imaging performance of preclinical transducers over a 10-years period.
- Open Access
Development of Preclinical Ultrasound Imaging Techniques to Identify and Image Sentinel Lymph Nodes in a Cancerous Animal Model
Lymph nodes (LNs) are believed to be the first organs targeted by colorectal cancer cells detached from a primary solid tumor because of their role in draining interstitial fluids. Better detection and assessment of these organs have the potential to help clinicians in stratification and designing optimal design of oncological treatments for each patient. Whilst highly valuable for the detection of primary tumors, CT and MRI remain limited for the characterization of LNs. B-mode ultrasound (US) and contrast-enhanced ultrasound (CEUS) can improve the detection of LNs and could provide critical complementary information to MRI and CT scans; however, the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines advise that further evidence is required before US or CEUS can be recommended for clinical use. Moreover, knowledge of the lymphatic system and LNs is relatively limited, especially in preclinical models. In this pilot study, we have created a mouse model of metastatic cancer and utilized 3D high-frequency ultrasound to assess the volume, shape, and absence of hilum, along with CEUS to assess the flow dynamics of tumor-free and tumor-bearing LNs in vivo. The aforementioned parameters were used to create a scoring system to predict the likelihood of a disease-involved LN before establishing post-mortem diagnosis with histopathology. Preliminary results suggest that a sum score of parameters may provide a more accurate diagnosis than the LN size, the single parameter currently used to predict the involvement of an LN in disease.
Open AccessDevelopment of Preclinical Ultrasound Imaging Techniques to Identify and Image Sentinel Lymph Nodes in a Cancerous Animal Model
Lymph nodes (LNs) are believed to be the first organs targeted by colorectal cancer cells detached from a primary solid tumor because of their role in draining interstitial fluids. Better detection and assessment of these organs have the potential to help clinicians in stratification and designing optimal design of oncological treatments for each patient. Whilst highly valuable for the detection of primary tumors, CT and MRI remain limited for the characterization of LNs. B-mode ultrasound (US) and contrast-enhanced ultrasound (CEUS) can improve the detection of LNs and could provide critical complementary information to MRI and CT scans; however, the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines advise that further evidence is required before US or CEUS can be recommended for clinical use. Moreover, knowledge of the lymphatic system and LNs is relatively limited, especially in preclinical models. In this pilot study, we have created a mouse model of metastatic cancer and utilized 3D high-frequency ultrasound to assess the volume, shape, and absence of hilum, along with CEUS to assess the flow dynamics of tumor-free and tumor-bearing LNs in vivo. The aforementioned parameters were used to create a scoring system to predict the likelihood of a disease-involved LN before establishing post-mortem diagnosis with histopathology. Preliminary results suggest that a sum score of parameters may provide a more accurate diagnosis than the LN size, the single parameter currently used to predict the involvement of an LN in disease.
- 26 June 2020
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 43 (04) , 393-402
The Imaging Performance of Diagnostic Ultrasound Scanners Using the Edinburgh Pipe Phantom to Measure the Resolution Integral – 15 Years of Experience
The grayscale imaging performance of a total of 368 different scanner/transducer combinations from 39 scanner manufacturers measured over a period of 15 years is presented. Performance was measured using the resolution integral, a single figure-of-merit to quantify ultrasound imaging performance. The resolution integral was measured using the Edinburgh Pipe Phantom. Transducers included single element, linear, phased, curvilinear and multi-row arrays. Our results demonstrate that the resolution integral clearly differentiates between transducers with varying levels of performance. Two further parameters were also derived from the resolution integral: characteristic resolution and depth of field. We demonstrate that these two parameters can successfully characterize individual transducer performance and differentiate between transducers designed for different clinical and preclinical applications. In conclusion, the resolution integral is an effective metric to quantify and monitor grayscale imaging performance in clinical practice. Die über einen Zeitraum von 15 Jahren gemessene Graustufen-Bildgebungsleistung von insgesamt 368 verschiedenen Scanner/Wandler-Kombinationen von 39 Herstellern wird vorgestellt. Die Leistung wurde unter Verwendung des Auflösungsintegrals gemessen, einer einzigen Gütezahl zur Quantifizierung der Ultraschall-Bildgebungsleistung. Das Auflösungsintegral wurde mit dem Edinburgh Pipe Phantom gemessen. Die Schallköpfe umfassten sowohl Einzelelement-, Linear-, Phased-, Curvilinear- und Multirow-Arrays. Unsere Ergebnisse zeigen, dass das Auflösungsintegral eindeutig zwischen Schallköpfen mit unterschiedlichen Leistungsniveaus unterscheidet. Zwei weitere Parameter wurden ebenfalls aus dem Auflösungsintegral abgeleitet: Die charakteristische Auflösung und die Tiefenschärfe. Wir zeigen, dass diese beiden Parameter die Leistung einzelner Schallköpfe erfolgreich charakterisieren und zwischen Schallköpfen unterscheiden können, die für unterschiedliche klinische und präklinische Anwendungen entwickelt wurden. Zusammenfassend lässt sich sagen, dass das Auflösungsintegral eine effektive Metrik zur Quantifizierung und Überwachung der Graustufen-Bildgebungsleistung in der klinischen Praxis ist.
- 26 June 2020
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 43 (04) , 393-402
The Imaging Performance of Diagnostic Ultrasound Scanners Using the Edinburgh Pipe Phantom to Measure the Resolution Integral – 15 Years of Experience
The grayscale imaging performance of a total of 368 different scanner/transducer combinations from 39 scanner manufacturers measured over a period of 15 years is presented. Performance was measured using the resolution integral, a single figure-of-merit to quantify ultrasound imaging performance. The resolution integral was measured using the Edinburgh Pipe Phantom. Transducers included single element, linear, phased, curvilinear and multi-row arrays. Our results demonstrate that the resolution integral clearly differentiates between transducers with varying levels of performance. Two further parameters were also derived from the resolution integral: characteristic resolution and depth of field. We demonstrate that these two parameters can successfully characterize individual transducer performance and differentiate between transducers designed for different clinical and preclinical applications. In conclusion, the resolution integral is an effective metric to quantify and monitor grayscale imaging performance in clinical practice. Die über einen Zeitraum von 15 Jahren gemessene Graustufen-Bildgebungsleistung von insgesamt 368 verschiedenen Scanner/Wandler-Kombinationen von 39 Herstellern wird vorgestellt. Die Leistung wurde unter Verwendung des Auflösungsintegrals gemessen, einer einzigen Gütezahl zur Quantifizierung der Ultraschall-Bildgebungsleistung. Das Auflösungsintegral wurde mit dem Edinburgh Pipe Phantom gemessen. Die Schallköpfe umfassten sowohl Einzelelement-, Linear-, Phased-, Curvilinear- und Multirow-Arrays. Unsere Ergebnisse zeigen, dass das Auflösungsintegral eindeutig zwischen Schallköpfen mit unterschiedlichen Leistungsniveaus unterscheidet. Zwei weitere Parameter wurden ebenfalls aus dem Auflösungsintegral abgeleitet: Die charakteristische Auflösung und die Tiefenschärfe. Wir zeigen, dass diese beiden Parameter die Leistung einzelner Schallköpfe erfolgreich charakterisieren und zwischen Schallköpfen unterscheiden können, die für unterschiedliche klinische und präklinische Anwendungen entwickelt wurden. Zusammenfassend lässt sich sagen, dass das Auflösungsintegral eine effektive Metrik zur Quantifizierung und Überwachung der Graustufen-Bildgebungsleistung in der klinischen Praxis ist.