Claas Philip Naehle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Claas Philip Naehle has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Hans Schild
Radiology, University of Bonn, Bonn, Germany
5 shared publicationsDaniel Thomas
Department of Radiology, University of Bonn, Bonn, Germany
4 shared publicationsTorsten Sommer
Department of Radiology, German Red Cross Hospital, Neuwied, Germany
4 shared publications- Alois Martin Sprinkart
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany
3 shared publications Carsten Meyer
Department of Radiology, University of Bonn, Bonn, Germany
3 shared publicationsHans H. Schild
Department of Radiology, University of Bonn, Bonn, Germany
3 shared publications
Latest Publications
- Open Access
- 4 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 284
Multiparametric Monitoring of Disease Progression in Contemporary Patients with Wild-Type Transthyretin Amyloid Cardiomyopathy Initiating Tafamidis Treatment
Background: Recently, a disease modifying therapy has become available for transthyretin amyloid cardiomyopathy (ATTR-CM). A validated monitoring concept of treatment is lacking, but a current expert consensus recommends three clinical domains (clinical, biomarker and ECG/imaging) assessed by several measurable features to define disease progression. Methods: We retrospectively analyzed data of wild-type ATTR-CM patients initiating tafamidis therapy assessed within our local routine protocol at baseline and 6-months follow-up with respect to the frequency of values beyond the proposed thresholds defining disease progression. Additionally, associations of cardiac magnetic resonance (CMR) tomography with clinical domains were examined within a subgroup. Results: Sixty-two ATTR-CM patients were included (88.7% male, mean age 79 years). In total, 16.1% of patients had progress in the clinical and functional domain, 33.9% in the biomarker domain and 43.5% in the imaging/electrocardiography (ECG) domain, with the latter driven by deterioration of the diastolic dysfunction grade and global longitudinal strain. In total, 35.5% of patients showed progress in none, 35.5% in one, 29.0% in two and no patient in three domains, the latter indicating overall disease progression. A subgroup analysis of twenty-two patients with available baseline and follow-up CMR data revealed an increase in CMR-based extracellular volume by more than 5% in 18.2% of patients, with no significant correlation with progress in one of the clinical domains. Conclusions: We provide first frequency estimates of the markers of disease progression according to a recent expert consensus statement, which might help refine the multiparametric monitoring concept in patients with ATTR-CM.
- 4 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (1) , 284
Open AccessMultiparametric Monitoring of Disease Progression in Contemporary Patients with Wild-Type Transthyretin Amyloid Cardiomyopathy Initiating Tafamidis Treatment
Background: Recently, a disease modifying therapy has become available for transthyretin amyloid cardiomyopathy (ATTR-CM). A validated monitoring concept of treatment is lacking, but a current expert consensus recommends three clinical domains (clinical, biomarker and ECG/imaging) assessed by several measurable features to define disease progression. Methods: We retrospectively analyzed data of wild-type ATTR-CM patients initiating tafamidis therapy assessed within our local routine protocol at baseline and 6-months follow-up with respect to the frequency of values beyond the proposed thresholds defining disease progression. Additionally, associations of cardiac magnetic resonance (CMR) tomography with clinical domains were examined within a subgroup. Results: Sixty-two ATTR-CM patients were included (88.7% male, mean age 79 years). In total, 16.1% of patients had progress in the clinical and functional domain, 33.9% in the biomarker domain and 43.5% in the imaging/electrocardiography (ECG) domain, with the latter driven by deterioration of the diastolic dysfunction grade and global longitudinal strain. In total, 35.5% of patients showed progress in none, 35.5% in one, 29.0% in two and no patient in three domains, the latter indicating overall disease progression. A subgroup analysis of twenty-two patients with available baseline and follow-up CMR data revealed an increase in CMR-based extracellular volume by more than 5% in 18.2% of patients, with no significant correlation with progress in one of the clinical domains. Conclusions: We provide first frequency estimates of the markers of disease progression according to a recent expert consensus statement, which might help refine the multiparametric monitoring concept in patients with ATTR-CM.
- 28 October 2017
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 67 (02) , 086-091
Safety and Feasibility of Magnetic Resonance Imaging of the Brain at 1.5 Tesla in Patients with Temporary Transmyocardial Pacing Leads
Background Temporary transmyocardial pacing leads (TTPLs) represent an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety and feasibility of MRI at 1.5 Tesla (T) using a transmit/receive (T/R) head coil in patients with TTPL. Methods TTPLs (220 cm, Osypka TME, Dr. Osypka GmbH, Rheinfelden, Germany) were implanted in a phantom and exposed to conditions of a 1.5 T brain examination using a T/R head coil. Temperature changes at the lead tip were continuously recorded. A total of 28 patients with TTPL and an urgent indication for a brain MRI underwent MRI at 1.5 T with vital sign monitoring. A T/R head coil was used to minimize radiofrequency exposure of the TTPL. Before and immediately after the MRI scan, TTPL lead impedance, pacing capture threshold (PCT), signal slope, and sensing were measured. Serum troponin I was determined before and after MRI to detect thermal myocardial injury. Results In vitro, the maximum temperature increase from radiofrequency-induced heating of the TTPL tip was < 1°C. In vivo, no complications, such as heating sensations, dizziness, unexpected changes in heart rate or rhythm, or other unusual signs or symptoms were observed. No significant changes in the lead impedance, PCT, signal slope, or sensing were recorded. There were no increases of serum troponin I after the MRI examination. Conclusions MRI of the brain may be performed safely at 1.5 T using a T/R head coil in case of an urgent clinical need in patients with TTPL and may be considered a feasible and safe procedure when appropriate precautionary measures are taken.
- 28 October 2017
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 67 (02) , 086-091
Safety and Feasibility of Magnetic Resonance Imaging of the Brain at 1.5 Tesla in Patients with Temporary Transmyocardial Pacing Leads
Background Temporary transmyocardial pacing leads (TTPLs) represent an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety and feasibility of MRI at 1.5 Tesla (T) using a transmit/receive (T/R) head coil in patients with TTPL. Methods TTPLs (220 cm, Osypka TME, Dr. Osypka GmbH, Rheinfelden, Germany) were implanted in a phantom and exposed to conditions of a 1.5 T brain examination using a T/R head coil. Temperature changes at the lead tip were continuously recorded. A total of 28 patients with TTPL and an urgent indication for a brain MRI underwent MRI at 1.5 T with vital sign monitoring. A T/R head coil was used to minimize radiofrequency exposure of the TTPL. Before and immediately after the MRI scan, TTPL lead impedance, pacing capture threshold (PCT), signal slope, and sensing were measured. Serum troponin I was determined before and after MRI to detect thermal myocardial injury. Results In vitro, the maximum temperature increase from radiofrequency-induced heating of the TTPL tip was < 1°C. In vivo, no complications, such as heating sensations, dizziness, unexpected changes in heart rate or rhythm, or other unusual signs or symptoms were observed. No significant changes in the lead impedance, PCT, signal slope, or sensing were recorded. There were no increases of serum troponin I after the MRI examination. Conclusions MRI of the brain may be performed safely at 1.5 T using a T/R head coil in case of an urgent clinical need in patients with TTPL and may be considered a feasible and safe procedure when appropriate precautionary measures are taken.
- 1 March 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 9 (3) , e004091
Cardiac Magnetic Resonance Reveals Signs of Subclinical Myocardial Inflammation in Asymptomatic HIV-Infected Patients
Background—: People living with chronic HIV infection are at an increased risk for cardiovascular disease. With this study, we aimed to determine the extent of cardiovascular involvement in asymptomatic HIV-infected patients by a comprehensive cardiac magnetic resonance (CMR) approach. Methods and Results—: Asymptomatic patients with chronic HIV infection undergoing combination antiretroviral therapy (n=28) and control subjects (n=22) underwent CMR. HIV-infected patients were successfully controlled for the disease with a consistent plasma viremia of + -cell count, 475.1±307.9 cells/μL). CMR protocol allowed for the determination of cardiac function, myocardial inflammation, myocardial fibrosis, aortic stiffness, and pericardial fat volume. When compared with healthy controls, HIV-infected patients showed alterations in left ventricular function as demonstrated by a lower ejection fraction (60.9±7.1% versus 65.2±5.5%; P =0.023) and lower global peak systolic longitudinal and circumferential strain values (longitudinal strain, −17.7±3.4% versus −20.2±3.2%, circumferential strain, −21.2±4.6% versus −24.7±5.1%; P P =0.009; relative T2 signal intensity ratio, 1.6±0.3 versus 1.4±0.3; P =0.046; early gadolinium enhancement ratio, 3.1±1.2 versus 2.1±0.6; P =0.003). Myocardial fibrosis, predominantly at the subepicardium of the midventricular and basal inferolateral wall, was prevalent in 82.1% of HIV-infected patients, but only in 27.3% of healthy controls ( P <0.001). Conclusions—: Comprehensive CMR revealed a high burden of cardiovascular disease in asymptomatic HIV-infected patients. Subclinical myocardial inflammation as detected by CMR may be a potential precursor of the increased cardiovascular morbidity and mortality observed in patients with chronic HIV infection.
- 1 March 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 9 (3) , e004091
Cardiac Magnetic Resonance Reveals Signs of Subclinical Myocardial Inflammation in Asymptomatic HIV-Infected Patients
Background—: People living with chronic HIV infection are at an increased risk for cardiovascular disease. With this study, we aimed to determine the extent of cardiovascular involvement in asymptomatic HIV-infected patients by a comprehensive cardiac magnetic resonance (CMR) approach. Methods and Results—: Asymptomatic patients with chronic HIV infection undergoing combination antiretroviral therapy (n=28) and control subjects (n=22) underwent CMR. HIV-infected patients were successfully controlled for the disease with a consistent plasma viremia of + -cell count, 475.1±307.9 cells/μL). CMR protocol allowed for the determination of cardiac function, myocardial inflammation, myocardial fibrosis, aortic stiffness, and pericardial fat volume. When compared with healthy controls, HIV-infected patients showed alterations in left ventricular function as demonstrated by a lower ejection fraction (60.9±7.1% versus 65.2±5.5%; P =0.023) and lower global peak systolic longitudinal and circumferential strain values (longitudinal strain, −17.7±3.4% versus −20.2±3.2%, circumferential strain, −21.2±4.6% versus −24.7±5.1%; P P =0.009; relative T2 signal intensity ratio, 1.6±0.3 versus 1.4±0.3; P =0.046; early gadolinium enhancement ratio, 3.1±1.2 versus 2.1±0.6; P =0.003). Myocardial fibrosis, predominantly at the subepicardium of the midventricular and basal inferolateral wall, was prevalent in 82.1% of HIV-infected patients, but only in 27.3% of healthy controls ( P <0.001). Conclusions—: Comprehensive CMR revealed a high burden of cardiovascular disease in asymptomatic HIV-infected patients. Subclinical myocardial inflammation as detected by CMR may be a potential precursor of the increased cardiovascular morbidity and mortality observed in patients with chronic HIV infection.
- Open Access
- 16 October 2015
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 17 (2) , 154-161
Incremental value of quantitative CMR including parametric mapping for the diagnosis of acute myocarditis
Cardiac magnetic resonance (CMR) can visualize inflammatory tissue changes in acute myocarditis. Several quantitative image-derived parameters have been described to enhance the diagnostic value of CMR, but no direct comparison of these techniques is available. A total of 34 patients with suspected acute myocarditis and 50 control subjects underwent CMR. CMR protocol included quantitative assessment of T1 relaxation times using modified Look-Locker inversion recovery (MOLLI) and shortened MOLLI (ShMOLLI) acquisition schemes, extracellular volume fraction (ECV), T2 relaxation times, and longitudinal strain. Established Lake-Louise criteria (LLC) consisting of T2-weighted signal intensity ratio (T2-ratio), early gadolinium enhancement ratio (EGEr), and late gadolinium enhancement (LGE) were assessed. Receiver operating characteristics analysis was performed to compare diagnostic performance. Areas under the curve of native T1 (MOLLI: 0.95; ShMOLLI: 0.92) and T2 relaxation times (0.92) were higher compared with those of the other CMR parameters (T2-ratio: 0.71, EGEr: 0.71, LGE: 0.87, LLC: 0.90, ECV MOLLI: 0.77, ECV ShMOLLI: 0.80, longitudinal strain: 0.83). Combined with LGE, each native mapping technique outperformed the diagnostic performance of LLC ( P < 0.01, respectively). A combination of native parameters (T1, T2, and longitudinal strain) significantly increased the diagnostic performance of CMR compared with LLC without need of contrast media application (0.99 vs. 0.90; P = 0.008). In patients suspected of having acute myocarditis, diagnostic performance of CMR can be improved by implementation of quantitative CMR parameters. Especially, native mapping techniques have the potential to replace current LLC. NCT02299856.
- 16 October 2015
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 17 (2) , 154-161
Open AccessIncremental value of quantitative CMR including parametric mapping for the diagnosis of acute myocarditis
Cardiac magnetic resonance (CMR) can visualize inflammatory tissue changes in acute myocarditis. Several quantitative image-derived parameters have been described to enhance the diagnostic value of CMR, but no direct comparison of these techniques is available. A total of 34 patients with suspected acute myocarditis and 50 control subjects underwent CMR. CMR protocol included quantitative assessment of T1 relaxation times using modified Look-Locker inversion recovery (MOLLI) and shortened MOLLI (ShMOLLI) acquisition schemes, extracellular volume fraction (ECV), T2 relaxation times, and longitudinal strain. Established Lake-Louise criteria (LLC) consisting of T2-weighted signal intensity ratio (T2-ratio), early gadolinium enhancement ratio (EGEr), and late gadolinium enhancement (LGE) were assessed. Receiver operating characteristics analysis was performed to compare diagnostic performance. Areas under the curve of native T1 (MOLLI: 0.95; ShMOLLI: 0.92) and T2 relaxation times (0.92) were higher compared with those of the other CMR parameters (T2-ratio: 0.71, EGEr: 0.71, LGE: 0.87, LLC: 0.90, ECV MOLLI: 0.77, ECV ShMOLLI: 0.80, longitudinal strain: 0.83). Combined with LGE, each native mapping technique outperformed the diagnostic performance of LLC ( P < 0.01, respectively). A combination of native parameters (T1, T2, and longitudinal strain) significantly increased the diagnostic performance of CMR compared with LLC without need of contrast media application (0.99 vs. 0.90; P = 0.008). In patients suspected of having acute myocarditis, diagnostic performance of CMR can be improved by implementation of quantitative CMR parameters. Especially, native mapping techniques have the potential to replace current LLC. NCT02299856.
- 1 September 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (9) , 1396-1402.e2
Effect of Peripheral Artery Sympathetic Denervation on Muscle Microperfusion and Macroperfusion in an Animal Peripheral Artery Disease Model Using Contrast-Enhanced Ultrasound and Doppler Flow Measurement
- 1 September 2015
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 26 (9) , 1396-1402.e2
Effect of Peripheral Artery Sympathetic Denervation on Muscle Microperfusion and Macroperfusion in an Animal Peripheral Artery Disease Model Using Contrast-Enhanced Ultrasound and Doppler Flow Measurement
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 1-9
Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 1-9
Open AccessGradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping
- Open Access
- 11 April 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Pulmonary sarcoidosis shortly after spinal tuberculosis infection: a diagnostic challenge
Tuberculosis and sarcoidosis share similar histopathological findings. An aetiological connection between these diseases has been discussed. We report a case of pulmonary sarcoidosis, which occurred shortly after an isoniazid (INH)-resistant spinal tuberculosis was diagnosed which was suspected to be a miliary tuberculosis. This report illustrates the need to sensitise clinicians to two possible important causes of lung parenchyma alterations under tuberculostatic therapy.
- 11 April 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Open AccessPulmonary sarcoidosis shortly after spinal tuberculosis infection: a diagnostic challenge
Tuberculosis and sarcoidosis share similar histopathological findings. An aetiological connection between these diseases has been discussed. We report a case of pulmonary sarcoidosis, which occurred shortly after an isoniazid (INH)-resistant spinal tuberculosis was diagnosed which was suspected to be a miliary tuberculosis. This report illustrates the need to sensitise clinicians to two possible important causes of lung parenchyma alterations under tuberculostatic therapy.
- Open Access
- 4 September 2013
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (10) , 1533
Necessary clarifications and minor corrections: Letter to the Editor regarding ‘2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy’
As welcome as including an overview on performing magnetic resonance imaging (MRI) in patients with pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) as well as suggestions on how to do it are, the just recently published guidelines1 are somewhat erroneous and require clarifications and minor, but important corrections.
- 4 September 2013
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (10) , 1533
Open AccessNecessary clarifications and minor corrections: Letter to the Editor regarding ‘2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy’
As welcome as including an overview on performing magnetic resonance imaging (MRI) in patients with pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) as well as suggestions on how to do it are, the just recently published guidelines1 are somewhat erroneous and require clarifications and minor, but important corrections.
- 16 November 2009
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 32 (12) , 1526-1535
Evaluation of Cumulative Effects of MR Imaging on Pacemaker Systems at 1.5 Tesla
Background: The purpose of this study was to evaluate possible cumulative effects of repeated magnetic resonance imaging (MRI) examinations on pacemaker systems in patients with cardiac pacemakers. Methods and Results: The records of pacemaker patients who underwent repetitive MRI examinations in our institution were reviewed to identify patients who underwent two or more MRI examinations at 1.5T of any anatomical region. Using these criteria, a total of 47 patients who underwent a total 171 MRI examinations were identified and included in this study. Institutional Review Board approval for all pacemaker investigations was obtained. Written informed consent was obtained from all patients. Pacemakers were interrogated immediately before and after MR imaging, and after 3 months, including measurement of pacing capture threshold (PCT), lead impedance (LI), and battery voltage (BV). PCT, LI, and BV were analyzed for changes dependant on the number of MRI exams performed. Mean changes over time and changes between first and last pacemaker interrogation of PCT, LI, and BV were calculated. A statistically significant (P < 0.05), but clinically irrelevant trend for decrease in PCT and BV was found. No significant or clinically relevant changes in LI were observed. Conclusion: In this first study, no clinically relevant, cumulative changes in PCT, LI, or BV could be detected in PM patients who underwent two or more MRI examinations. However, a careful benefit/risk evaluation, among other MRI‐ and pacemaker‐related safety precautions, remains mandatory, as clinically relevant alterations to the PM system cannot be excluded by all means.
- 16 November 2009
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 32 (12) , 1526-1535
Evaluation of Cumulative Effects of MR Imaging on Pacemaker Systems at 1.5 Tesla
Background: The purpose of this study was to evaluate possible cumulative effects of repeated magnetic resonance imaging (MRI) examinations on pacemaker systems in patients with cardiac pacemakers. Methods and Results: The records of pacemaker patients who underwent repetitive MRI examinations in our institution were reviewed to identify patients who underwent two or more MRI examinations at 1.5T of any anatomical region. Using these criteria, a total of 47 patients who underwent a total 171 MRI examinations were identified and included in this study. Institutional Review Board approval for all pacemaker investigations was obtained. Written informed consent was obtained from all patients. Pacemakers were interrogated immediately before and after MR imaging, and after 3 months, including measurement of pacing capture threshold (PCT), lead impedance (LI), and battery voltage (BV). PCT, LI, and BV were analyzed for changes dependant on the number of MRI exams performed. Mean changes over time and changes between first and last pacemaker interrogation of PCT, LI, and BV were calculated. A statistically significant (P < 0.05), but clinically irrelevant trend for decrease in PCT and BV was found. No significant or clinically relevant changes in LI were observed. Conclusion: In this first study, no clinically relevant, cumulative changes in PCT, LI, or BV could be detected in PM patients who underwent two or more MRI examinations. However, a careful benefit/risk evaluation, among other MRI‐ and pacemaker‐related safety precautions, remains mandatory, as clinically relevant alterations to the PM system cannot be excluded by all means.