Paul-Rolf Preußner
Research Subjects
Paul-Rolf Preußner has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Faustin Ngounou
Presbyterian Health Services Eye Clinic, Bafoussam, Cameroon
2 shared publicationsGabriel Kouogan
Presbyterian Health Services Eye Clinic, Bafoussam, Cameroon
2 shared publicationsJochen Wahl
University Eye Hospital, Mainz, Germany, and
2 shared publicationsPeter Hoffmann
Private Eye Clinic, Castrop-Rauxel, Germany
2 shared publicationsAchim Langenbucher
Institut für experimentelle Ophthalmologie der Universität des Saarlandes, Homburg, Deutschland
1 shared publicationAllegra Großmann
University Eye Hospital, Mainz, Germany
1 shared publication
Latest Publications
- 24 October 2024
- Published by Springer Nature in Die Ophthalmologie
- Vol. 121 (11) , 858-865
Grundlegende Aspekte zur IOL-Berechnung
- 24 October 2024
- Published by Springer Nature in Die Ophthalmologie
- Vol. 121 (11) , 858-865
Grundlegende Aspekte zur IOL-Berechnung
- Open Access
- 3 January 2024
- Published by Springer Nature
- p. 717-730
OKULIX Raytracing Software
The raytracing software package OKULIX was initially developed for scientific purposes in the context of accommodating IOLs. Later it was extended to corneal laser surgery which is still available in the “corneal module” of OKULIX. The latest development was then the application to IOL calculation. One of the essential guidelines of the software development was to reduce universal applicability (unlike as in other commercially available raytracing software) in order to optimize it to the special situation of a human eye, i.e., concentration of the fovea as the only optical area of interest, and restriction to mostly four but in maximum six refracting surfaces. In addition, the collection of the manufacturer’s blue prints of the big majority of IOL models on the market was necessary, including continuous updates. In general, the result is an IOL calculation software that is based on physical rather than on statistical data to the highest possible extent, applicable to all kinds of eyes, even without knowing their history. Other than in most IOL formulas, missing information is not taken from Gullstrand’s but from Liou and Brennan’s eye model. The accuracy of OKULIX IOL calculations has been proven to be never systematically worse compared to other methods when the same measured input data are used.
- 3 January 2024
- Published by Springer Nature
- p. 717-730
Open AccessOKULIX Raytracing Software
The raytracing software package OKULIX was initially developed for scientific purposes in the context of accommodating IOLs. Later it was extended to corneal laser surgery which is still available in the “corneal module” of OKULIX. The latest development was then the application to IOL calculation. One of the essential guidelines of the software development was to reduce universal applicability (unlike as in other commercially available raytracing software) in order to optimize it to the special situation of a human eye, i.e., concentration of the fovea as the only optical area of interest, and restriction to mostly four but in maximum six refracting surfaces. In addition, the collection of the manufacturer’s blue prints of the big majority of IOL models on the market was necessary, including continuous updates. In general, the result is an IOL calculation software that is based on physical rather than on statistical data to the highest possible extent, applicable to all kinds of eyes, even without knowing their history. Other than in most IOL formulas, missing information is not taken from Gullstrand’s but from Liou and Brennan’s eye model. The accuracy of OKULIX IOL calculations has been proven to be never systematically worse compared to other methods when the same measured input data are used.
- 5 March 2018
- Published by Springer Nature in Der Ophthalmologe
- Vol. 115 (4) , 336-339
Kontrollierte Zyklophotokoagulation (COCO)
Der Hauptnachteil moderner Zyklokoagulationen mittels Laser liegt in der im Einzelfall schlecht vorhersagbaren therapeutischen Wirkung. Unerwünschte Schäden und Komplikationen sind aber speziell mit der kontrollierten Zyklophotokoagulation (COCO) v. a. durch die hohe Selektivität der Photoabsorption extrem unwahrscheinlich. Daher können und müssen diese Eingriffe wiederholt werden, wenn die erwünschte Drucksenkung bei der ersten Behandlung nicht eintritt oder später wieder nachlässt. Indikationen und Protokolle für die Wiederholungseingriffe unterscheiden sich dabei nicht von denen der Ersteingriffe. The major disadvantage of modern laser cyclocoagulation is the low predictability of therapeutic success in individual cases. Unwanted damage and complications of controlled cyclophotocoagulation (COCO) are very unlikely, particularly because of the high selectivity of photoabsorption. Therefore, these interventions can and must be repeated if the intraocular pressure reduction is insufficient after the initial treatment or if the pressure increases again later. The indications and protocol for repeat interventions are the same as for the initial intervention.
- 5 March 2018
- Published by Springer Nature in Der Ophthalmologe
- Vol. 115 (4) , 336-339
Kontrollierte Zyklophotokoagulation (COCO)
Der Hauptnachteil moderner Zyklokoagulationen mittels Laser liegt in der im Einzelfall schlecht vorhersagbaren therapeutischen Wirkung. Unerwünschte Schäden und Komplikationen sind aber speziell mit der kontrollierten Zyklophotokoagulation (COCO) v. a. durch die hohe Selektivität der Photoabsorption extrem unwahrscheinlich. Daher können und müssen diese Eingriffe wiederholt werden, wenn die erwünschte Drucksenkung bei der ersten Behandlung nicht eintritt oder später wieder nachlässt. Indikationen und Protokolle für die Wiederholungseingriffe unterscheiden sich dabei nicht von denen der Ersteingriffe. The major disadvantage of modern laser cyclocoagulation is the low predictability of therapeutic success in individual cases. Unwanted damage and complications of controlled cyclophotocoagulation (COCO) are very unlikely, particularly because of the high selectivity of photoabsorption. Therefore, these interventions can and must be repeated if the intraocular pressure reduction is insufficient after the initial treatment or if the pressure increases again later. The indications and protocol for repeat interventions are the same as for the initial intervention.
- 26 September 2014
- Published by Taylor & Francis in Current Eye Research
- Vol. 40 (8) , 809-814
Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation
Purpose: To quantify the impact of posterior cornea on toric IOL calculation accuracy using Placido-topography of anterior corneal surface and Scheimpflug measurements of corneal thickness. Materials and Methods: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences. Results: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 ± 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3–6 D at 90, 0.38 D at 89° and 0.28 D at 91° (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81° from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis. Conclusion: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.
- 26 September 2014
- Published by Taylor & Francis in Current Eye Research
- Vol. 40 (8) , 809-814
Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation
Purpose: To quantify the impact of posterior cornea on toric IOL calculation accuracy using Placido-topography of anterior corneal surface and Scheimpflug measurements of corneal thickness. Materials and Methods: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences. Results: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 ± 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3–6 D at 90, 0.38 D at 89° and 0.28 D at 91° (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81° from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis. Conclusion: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.
- 2 May 2010
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 248 (10) , 1473-1479
Controlled cyclophotocoagulation with the 940 nm laser for primary open angle glaucoma in African eyes
Background “Controlled cyclophotocoagulation” is a real-time dosage control which reduces the complications of transscleral cyclophotocoagulation to a negligible amount in European eyes. Applied to a few African eyes, however, the method failed. Obviously, the physical parameters of the laser procedure need adjustment to African eyes. Method and material After theoretical investigations and tests in African cadaver eyes, 940 nm laser wavelength instead of 810 nm and a different fiber coupling had solved the problem of physical differences between European and African eyes to a large extent. The method was then applied to 272 eyes of 188 patients with primary open-angle glaucoma, of which it was possible to follow 26 eyes of 18 patients for at least 1 year. Median age of the patients was 63.7 years, with the youngest 16.8 years, the oldest 88.8 years. Either 16 or 24 laser spots were applied at random. If both eyes were treated, they were treated in the same session. Results The average intraocular pressure (IOP) reduction after 1 year was 7.5 mmHg, with average glaucoma drug reduction from 1.5 to 1.2 substances. At least one pop spot occurred in 32% of the eyes. No statistically significant difference between 16 and 24 spots was found. No severe complications such as intraocular bleeding, hypotony <7 mmHg, choroidal detachment or phthisis were observed. Conclusion Controlled cyclophotocoagulation with the 940 nm laser is a safe method which can be applied as the first-choice treatment to African primary open-angle glaucoma eyes. Individual IOP prediction, however, is very difficult.
- 2 May 2010
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 248 (10) , 1473-1479
Controlled cyclophotocoagulation with the 940 nm laser for primary open angle glaucoma in African eyes
Background “Controlled cyclophotocoagulation” is a real-time dosage control which reduces the complications of transscleral cyclophotocoagulation to a negligible amount in European eyes. Applied to a few African eyes, however, the method failed. Obviously, the physical parameters of the laser procedure need adjustment to African eyes. Method and material After theoretical investigations and tests in African cadaver eyes, 940 nm laser wavelength instead of 810 nm and a different fiber coupling had solved the problem of physical differences between European and African eyes to a large extent. The method was then applied to 272 eyes of 188 patients with primary open-angle glaucoma, of which it was possible to follow 26 eyes of 18 patients for at least 1 year. Median age of the patients was 63.7 years, with the youngest 16.8 years, the oldest 88.8 years. Either 16 or 24 laser spots were applied at random. If both eyes were treated, they were treated in the same session. Results The average intraocular pressure (IOP) reduction after 1 year was 7.5 mmHg, with average glaucoma drug reduction from 1.5 to 1.2 substances. At least one pop spot occurred in 32% of the eyes. No statistically significant difference between 16 and 24 spots was found. No severe complications such as intraocular bleeding, hypotony <7 mmHg, choroidal detachment or phthisis were observed. Conclusion Controlled cyclophotocoagulation with the 940 nm laser is a safe method which can be applied as the first-choice treatment to African primary open-angle glaucoma eyes. Individual IOP prediction, however, is very difficult.
- 23 August 2009
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 247 (12) , 1671-1675
Glaucoma screening in Western Cameroon
Purpose To quantify glaucoma-related parameters in a rural African region. Material and method In a population-based investigation, 635 persons in six villages underwent slit-lamp examination including investigation of the optic nerve head with a 90D lens and Goldmann applanation tonometry. The mean age of the persons was 49.4 ± 19 years, minimum 5, maximum 90, median 52 years. The inferior, superior, nasal and temporal margin width of the optic nerve head (ONH) were estimated as fractions of the total disk diameter, thus allowing the evaluation of the horizontal and vertical cup–disk ratio (CDR), the ratio of the elliptical cup area to the total disk area (area CDR), and violations of the ISNT rule (Inferior≥Superior≥Nasal≥Temporal ONH rim). Results Area CDR significantly increased with age, on average from 0.1 in the youngest to 0.47 in the oldest person, corresponding to an increase of linear CDR from 0.32 to 0.68. The total fraction of eyes exceeding an area CDR of 0.5 (i.e. linear 0.7) was 13.4%. In addition, the intraocular pressure (IOP) increased on average from 14 mmHg in the youngest to 20 mmHg in the oldest persons, but nevertheless many high CDR values were found in eyes with normal to moderately elevated IOP. Violations of the ISNT rule were found in ~25% of the eyes. Application of a combination of glaucoma criteria as commonly used in literature resulted in a total prevalence of 18.7% of the screened persons, corresponding to a prevalence of 8.2% after age correction for the—on average—very young Cameroonian population. Conclusion Compared to Europe, glaucoma prevalence appears to be nearly an order of magnitude higher in this rural African population.
- 23 August 2009
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 247 (12) , 1671-1675
Glaucoma screening in Western Cameroon
Purpose To quantify glaucoma-related parameters in a rural African region. Material and method In a population-based investigation, 635 persons in six villages underwent slit-lamp examination including investigation of the optic nerve head with a 90D lens and Goldmann applanation tonometry. The mean age of the persons was 49.4 ± 19 years, minimum 5, maximum 90, median 52 years. The inferior, superior, nasal and temporal margin width of the optic nerve head (ONH) were estimated as fractions of the total disk diameter, thus allowing the evaluation of the horizontal and vertical cup–disk ratio (CDR), the ratio of the elliptical cup area to the total disk area (area CDR), and violations of the ISNT rule (Inferior≥Superior≥Nasal≥Temporal ONH rim). Results Area CDR significantly increased with age, on average from 0.1 in the youngest to 0.47 in the oldest person, corresponding to an increase of linear CDR from 0.32 to 0.68. The total fraction of eyes exceeding an area CDR of 0.5 (i.e. linear 0.7) was 13.4%. In addition, the intraocular pressure (IOP) increased on average from 14 mmHg in the youngest to 20 mmHg in the oldest persons, but nevertheless many high CDR values were found in eyes with normal to moderately elevated IOP. Violations of the ISNT rule were found in ~25% of the eyes. Application of a combination of glaucoma criteria as commonly used in literature resulted in a total prevalence of 18.7% of the screened persons, corresponding to a prevalence of 8.2% after age correction for the—on average—very young Cameroonian population. Conclusion Compared to Europe, glaucoma prevalence appears to be nearly an order of magnitude higher in this rural African population.
- 1 September 2008
- Published by Springer Nature in Spektrum der Augenheilkunde
- Vol. 22 (4) , 247-251
Kontrollierte Zyklophotokoagulation (COCO)
- 1 September 2008
- Published by Springer Nature in Spektrum der Augenheilkunde
- Vol. 22 (4) , 247-251
Kontrollierte Zyklophotokoagulation (COCO)
- 1 May 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (5) , 802-808
Intraocular lens calculation accuracy limits in normal eyes
To quantify the current accuracy limits, analyze the residual errors, and propose the next steps for prediction accuracy improvements. Eye hospitals in Germany, Denmark, and Austria. Numerical ray tracing using manufacturer's intraocular lens (IOL) data (vertex radii, central thickness, refractive index) was used for all calculations. Postoperative lens position was predicted by a simple scaling model based on measurements in 1 patient collective. The model was compared with 2 other approaches in 2 patient collectives at 2 hospitals (1121 eyes with 13 IOL models; 936 eyes with 2 models). Axial lengths were measured optically (IOLMaster, Zeiss). No parameter adjustments or individualization of IOL types or of surgeons/localizations were done. The prediction errors and measures of systematic bias for short or long eyes were used to quantify the outcome. The mean prediction errors in the 2 collectives were +0.13 diopter (D) and -0.13 D and the mean absolute errors were 0.44 D and 0.50 D without bias for long or short eyes, but depending on the IOL position model approach. The differences in the mean prediction errors for the IOL types were below the allowed manufacturing tolerances and below human recognition thresholds. The need to individualize and fudge parameters decreases with better physical models of the pseudophakic eye. Further improvements are possible by individual topography to extract corneal asphericity and measured pupil size to calculate the best focus, by improved position predictions based on individual measurements of the crystalline lens and by smaller tolerances for IOL manufacturing.
- 1 May 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (5) , 802-808
Intraocular lens calculation accuracy limits in normal eyes
To quantify the current accuracy limits, analyze the residual errors, and propose the next steps for prediction accuracy improvements. Eye hospitals in Germany, Denmark, and Austria. Numerical ray tracing using manufacturer's intraocular lens (IOL) data (vertex radii, central thickness, refractive index) was used for all calculations. Postoperative lens position was predicted by a simple scaling model based on measurements in 1 patient collective. The model was compared with 2 other approaches in 2 patient collectives at 2 hospitals (1121 eyes with 13 IOL models; 936 eyes with 2 models). Axial lengths were measured optically (IOLMaster, Zeiss). No parameter adjustments or individualization of IOL types or of surgeons/localizations were done. The prediction errors and measures of systematic bias for short or long eyes were used to quantify the outcome. The mean prediction errors in the 2 collectives were +0.13 diopter (D) and -0.13 D and the mean absolute errors were 0.44 D and 0.50 D without bias for long or short eyes, but depending on the IOL position model approach. The differences in the mean prediction errors for the IOL types were below the allowed manufacturing tolerances and below human recognition thresholds. The need to individualize and fudge parameters decreases with better physical models of the pseudophakic eye. Further improvements are possible by individual topography to extract corneal asphericity and measured pupil size to calculate the best focus, by improved position predictions based on individual measurements of the crystalline lens and by smaller tolerances for IOL manufacturing.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (3) , 525-533
Topography-based intraocular lens power selection
To provide mathematical tools for selecting intraocular lens (IOL) power for normal eyes and for "odd" eyes, particularly after corneal refractive surgery. Universitats-Augenklinik, Mainz, Germany. First, IOL power is selected based on the radii and numerical eccentricity of the cornea, extracted from corneal topography in a consistent numerical model of the cornea. To fine-tune the result, the visual impression is simulated by blurred Landolt rings superimposed on the retinal receptor grid. The calculation uses numerical ray tracing of the whole pseudophakic eye comprising all monochromatic errors. The error contributions of the influencing parameters, such as anterior and posterior corneal shape and corneal thickness, are quantified in detail. The method is verified in IOL power selection for normal eyes and for eyes after corneal refractive surgery. The main difference between normal corneas and corneas after refractive surgery results from different asphericities. Normal corneas are prolate, with typical numerical eccentricities of 0.5, whereas corneas after laser surgery for myopia are oblate. This causes the main difference (hyperopic shift up to 2.0 diopters) in IOL power selection. Shifts in the posterior corneal radius and corneal thickness are of minor importance. Intraocular power selection after corneal refractive surgery should be based on all the information corneal topography provides.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (3) , 525-533
Topography-based intraocular lens power selection
To provide mathematical tools for selecting intraocular lens (IOL) power for normal eyes and for "odd" eyes, particularly after corneal refractive surgery. Universitats-Augenklinik, Mainz, Germany. First, IOL power is selected based on the radii and numerical eccentricity of the cornea, extracted from corneal topography in a consistent numerical model of the cornea. To fine-tune the result, the visual impression is simulated by blurred Landolt rings superimposed on the retinal receptor grid. The calculation uses numerical ray tracing of the whole pseudophakic eye comprising all monochromatic errors. The error contributions of the influencing parameters, such as anterior and posterior corneal shape and corneal thickness, are quantified in detail. The method is verified in IOL power selection for normal eyes and for eyes after corneal refractive surgery. The main difference between normal corneas and corneas after refractive surgery results from different asphericities. Normal corneas are prolate, with typical numerical eccentricities of 0.5, whereas corneas after laser surgery for myopia are oblate. This causes the main difference (hyperopic shift up to 2.0 diopters) in IOL power selection. Shifts in the posterior corneal radius and corneal thickness are of minor importance. Intraocular power selection after corneal refractive surgery should be based on all the information corneal topography provides.