Latest Publications
- 1 January 2012
- Vol. 1 (4) , 257-264
Impact of decaying dose rate in gamma knife radiosurgery: in vitro study on 9L rat gliosarcoma cells.
Leksell Gamma Knife (LGK) installations replace their Co-60 sources every 5-10 years corresponding to one two Co-60 half-lives. Between source replacements the dose rate gradually declines. The purpose of this study was to assess whether the decreasing dose rates associated with radioactive decay of Co-60 may affect the radiobiological response of a given dose delivered to 9L rat gliosarcoma cells. 9L rat gliosarcoma cells were irradiated using LGK U, LGK 4C, and LGK Perfexion providing three different dose rates of 0.770 Gy/ min (sources reloaded 12.0 years ago), 1.853 Gy/min (sources reloaded 5.0 years ago) and 2.937 Gy/min (sources reloaded 1.6 years ago), respectively. After irradiation of cell samples to 4.0 Gy, 8.0 Gy and 16.0 Gy using each of the LGK units, the irradiated cells were plated into petri dishes. Two weeks later cell colonies with greater than 50 cells were counted. The survival of cells was plotted as a function of dose over the range of delivered doses and fitted to a linear quadratic function of the form SD = e-αD-βD2 , where α and β are terms fit using the Levenberg-Marquardt algorithm. This study demonstrated no difference in tumor cell kill in the range of dose rates when using actual LGK unit with new sources or with sources decayed even for two half lives. This study focused on tumor cells. In future studies we will reassess the dose rate effect on cultured neurons to simulate response of normal healthy brain tissue to different dose rates.
- 1 January 2012
- Vol. 1 (4) , 257-264
Impact of decaying dose rate in gamma knife radiosurgery: in vitro study on 9L rat gliosarcoma cells.
Leksell Gamma Knife (LGK) installations replace their Co-60 sources every 5-10 years corresponding to one two Co-60 half-lives. Between source replacements the dose rate gradually declines. The purpose of this study was to assess whether the decreasing dose rates associated with radioactive decay of Co-60 may affect the radiobiological response of a given dose delivered to 9L rat gliosarcoma cells. 9L rat gliosarcoma cells were irradiated using LGK U, LGK 4C, and LGK Perfexion providing three different dose rates of 0.770 Gy/ min (sources reloaded 12.0 years ago), 1.853 Gy/min (sources reloaded 5.0 years ago) and 2.937 Gy/min (sources reloaded 1.6 years ago), respectively. After irradiation of cell samples to 4.0 Gy, 8.0 Gy and 16.0 Gy using each of the LGK units, the irradiated cells were plated into petri dishes. Two weeks later cell colonies with greater than 50 cells were counted. The survival of cells was plotted as a function of dose over the range of delivered doses and fitted to a linear quadratic function of the form SD = e-αD-βD2 , where α and β are terms fit using the Levenberg-Marquardt algorithm. This study demonstrated no difference in tumor cell kill in the range of dose rates when using actual LGK unit with new sources or with sources decayed even for two half lives. This study focused on tumor cells. In future studies we will reassess the dose rate effect on cultured neurons to simulate response of normal healthy brain tissue to different dose rates.
- 20 December 2011
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 231-236
Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife®PerfexionTM
Purpose: The purpose of this study was to evaluate the dosimetric characteristics of each sector of the Leksell Gamma Knife Perfexion (LGK PFX) and to develop tests that can be done for the routine quality assurance checks of the sectors of the LGK PFX. Methods: The following tests were performed to evaluate the dosimetric characteristics of the sectors: (1) Flash-radiation dose for the 16 mm collimator, (2) transit-radiation dose for the 8 and 4 mm collimators, (3) sector leakage within the radiationcavity and, (4) sector output uniformity. In these tests, the Elekta ABS phantom was used. A micropoint ion-chamber Exradin A16 was placed at the center of the phantom for all measurements. Results: With the version 8.0 of the control software of the MCU in the LGK PFX, the average flash-radiation dose per sector for the 16 mm collimator was measured to be 0.423 ± 0.003 cGy, and the average transit-radiation dose per sector for the 8 and 4 mm collimators was measured to be 0.169 ± 0.0009 and 0.147 ± 0.020 cGy, respectively. The calibrationdose rate on the day of measurements was 280.8 cGy/min. Here, the authors have introduced a new concept of “equivalent-time-duration” (ETD) to represent the time duration, during which the flash-radiation or the transit-radiation dose is delivered. The ETD is a quotient of the measureddose of the flash-radiation or the transit-radiation and the respective calibrated dose rate for the 16, 8, or 4 mm collimator. The ETD constancy is an indicator of the constancy of the sector movements. The average value of ETD per sector was measured to be 724 ± 6, 313 ± 2, and 311 ± 45 ms for the 16, 8, and 4 mm collimators, respectively. During monthly spot checks, the authors have been measuring the total ETD for the flash-radiation when all eight sectors are open with the 16 mm collimator. The average value of the total ETD of the last 40 consecutive months was measured to be 642 ± 10 ms. This number is a useful quality parameter for the LGK PFX, which can be used to establish the base-line performance of the collimators of the LGK PFX. The reader is alerted that with the newly introduced version 9.0 of the control software of the MCU in the LGK PFX, the flash-radiation and the transit-radiation doses have become practically zero due to the fact that the treatment time is now corrected to compensate for these radiationdoses. The sector output uniformity for the 16, 8, and 4 mm collimators was determined to be 98.9%, 97.3%, and 96.6%, respectively. The total leakage radiation with in the radiationcavity from all sectors was measured to be 0.17% of the dose output for the 16 mm collimator. Conclusions: Our measurements show that the dosimetric characteristics of all sectors of the LGK PFX are satisfactory. The authors recommend that the sector performance of the LGK PFX be determined initially at the time of installation of the LGK PFX and thereafter, at least annually. Similarly, our recommendation is that the total flash-radiation dose for the 16 mm collimator and the corresponding ETD value be measured on a monthly basis. Should any change in the sector movement occur, it will be revealed by the sector performance and the measurement of ETD.
- 20 December 2011
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 231-236
Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife®PerfexionTM
Purpose: The purpose of this study was to evaluate the dosimetric characteristics of each sector of the Leksell Gamma Knife Perfexion (LGK PFX) and to develop tests that can be done for the routine quality assurance checks of the sectors of the LGK PFX. Methods: The following tests were performed to evaluate the dosimetric characteristics of the sectors: (1) Flash-radiation dose for the 16 mm collimator, (2) transit-radiation dose for the 8 and 4 mm collimators, (3) sector leakage within the radiationcavity and, (4) sector output uniformity. In these tests, the Elekta ABS phantom was used. A micropoint ion-chamber Exradin A16 was placed at the center of the phantom for all measurements. Results: With the version 8.0 of the control software of the MCU in the LGK PFX, the average flash-radiation dose per sector for the 16 mm collimator was measured to be 0.423 ± 0.003 cGy, and the average transit-radiation dose per sector for the 8 and 4 mm collimators was measured to be 0.169 ± 0.0009 and 0.147 ± 0.020 cGy, respectively. The calibrationdose rate on the day of measurements was 280.8 cGy/min. Here, the authors have introduced a new concept of “equivalent-time-duration” (ETD) to represent the time duration, during which the flash-radiation or the transit-radiation dose is delivered. The ETD is a quotient of the measureddose of the flash-radiation or the transit-radiation and the respective calibrated dose rate for the 16, 8, or 4 mm collimator. The ETD constancy is an indicator of the constancy of the sector movements. The average value of ETD per sector was measured to be 724 ± 6, 313 ± 2, and 311 ± 45 ms for the 16, 8, and 4 mm collimators, respectively. During monthly spot checks, the authors have been measuring the total ETD for the flash-radiation when all eight sectors are open with the 16 mm collimator. The average value of the total ETD of the last 40 consecutive months was measured to be 642 ± 10 ms. This number is a useful quality parameter for the LGK PFX, which can be used to establish the base-line performance of the collimators of the LGK PFX. The reader is alerted that with the newly introduced version 9.0 of the control software of the MCU in the LGK PFX, the flash-radiation and the transit-radiation doses have become practically zero due to the fact that the treatment time is now corrected to compensate for these radiationdoses. The sector output uniformity for the 16, 8, and 4 mm collimators was determined to be 98.9%, 97.3%, and 96.6%, respectively. The total leakage radiation with in the radiationcavity from all sectors was measured to be 0.17% of the dose output for the 16 mm collimator. Conclusions: Our measurements show that the dosimetric characteristics of all sectors of the LGK PFX are satisfactory. The authors recommend that the sector performance of the LGK PFX be determined initially at the time of installation of the LGK PFX and thereafter, at least annually. Similarly, our recommendation is that the total flash-radiation dose for the 16 mm collimator and the corresponding ETD value be measured on a monthly basis. Should any change in the sector movement occur, it will be revealed by the sector performance and the measurement of ETD.
- 1 January 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102, 8-13
Does new magnetic resonance imaging technology provide better geometrical accuracy during stereotactic imaging?
The authors sought to compare the accuracy of stereotactic target imaging using the Siemens 1T EXPERT and 1.5T SYMPHONY magnetic resonance (MR) units. A water-filled cylindrical Perspex phantom with axial and coronal inserts containing grids of glass rods was fixed in the Leksell stereotactic frame and subjected to MR imaging in Siemens 1T EXPERT and Siemens 1.5T SYMPHONY units. Identical sequences were used for each unit. The images were transferred to the GammaPlan treatment planning system. Deviations between stereotactic coordinates based on MR images and estimated real geometrical positions given by the construction of the phantom insert were evaluated for each study. The deviations were further investigated as a function of the MR unit used, MR sequence, the image orientation, and the spatial position of measured points in the investigated volume. Larger distortions were observed when using the SYMPHONY 1.5T unit than those with the EXPERT 1T unit. Typical average distortion in EXPERT 1T was not more than 0.6 mm and 0.9 mm for axial and coronal images, respectively. Typical mean distortion for SYMPHONY 1.5T was not more than 1 mm and 1.3 mm for axial and coronal images, respectively. The image sequence affected the distortions in both units. Coronal T2-weighted spin-echo images performed in subthalamic imaging produced the largest distortions of 2.6 mm and 3 mm in the EXPERT 1T and SYMPHONY 1.5T, respectively. Larger distortions were observed in coronal slices than in axial slices in both units, and this effect was more pronounced in SYMPHONY 1.5T. Noncentrally located slice positions in the investigated volume of the phantom were associated with larger distortions.
- 1 January 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102, 8-13
Does new magnetic resonance imaging technology provide better geometrical accuracy during stereotactic imaging?
The authors sought to compare the accuracy of stereotactic target imaging using the Siemens 1T EXPERT and 1.5T SYMPHONY magnetic resonance (MR) units. A water-filled cylindrical Perspex phantom with axial and coronal inserts containing grids of glass rods was fixed in the Leksell stereotactic frame and subjected to MR imaging in Siemens 1T EXPERT and Siemens 1.5T SYMPHONY units. Identical sequences were used for each unit. The images were transferred to the GammaPlan treatment planning system. Deviations between stereotactic coordinates based on MR images and estimated real geometrical positions given by the construction of the phantom insert were evaluated for each study. The deviations were further investigated as a function of the MR unit used, MR sequence, the image orientation, and the spatial position of measured points in the investigated volume. Larger distortions were observed when using the SYMPHONY 1.5T unit than those with the EXPERT 1T unit. Typical average distortion in EXPERT 1T was not more than 0.6 mm and 0.9 mm for axial and coronal images, respectively. Typical mean distortion for SYMPHONY 1.5T was not more than 1 mm and 1.3 mm for axial and coronal images, respectively. The image sequence affected the distortions in both units. Coronal T2-weighted spin-echo images performed in subthalamic imaging produced the largest distortions of 2.6 mm and 3 mm in the EXPERT 1T and SYMPHONY 1.5T, respectively. Larger distortions were observed in coronal slices than in axial slices in both units, and this effect was more pronounced in SYMPHONY 1.5T. Noncentrally located slice positions in the investigated volume of the phantom were associated with larger distortions.
- 1 January 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102 (Special_Su) , 8-13
Does new magnetic resonance imaging technology provide better geometrical accuracy during stereotactic imaging?
Object. The authors sought to compare the accuracy of stereotactic target imaging using the Siemens 1T EXPERT and 1.5T SYMPHONY magnetic resonance (MR) units. Methods. A water-filled cylindrical Perspex phantom with axial and coronal inserts containing grids of glass rods was fixed in the Leksell stereotactic frame and subjected to MR imaging in Siemens 1T EXPERT and Siemens 1.5T SYMPHONY units. Identical sequences were used for each unit. The images were transferred to the GammaPlan treatment planning system. Deviations between stereotactic coordinates based on MR images and estimated real geometrical positions given by the construction of the phantom insert were evaluated for each study. The deviations were further investigated as a function of the MR unit used, MR sequence, the image orientation, and the spatial position of measured points in the investigated volume. Conclusions. Larger distortions were observed when using the SYMPHONY 1.5T unit than those with the EXPERT 1T unit. Typical average distortion in EXPERT 1T was not more than 0.6 mm and 0.9 mm for axial and coronal images, respectively. Typical mean distortion for SYMPHONY 1.5T was not more than 1 mm and 1.3 mm for axial and coronal images, respectively. The image sequence affected the distortions in both units. Coronal T2-weighted spin-echo images performed in subthalamic imaging produced the largest distortions of 2.6 mm and 3 mm in the EXPERT 1T and SYMPHONY 1.5T, respectively. Larger distortions were observed in coronal slices than in axial slices in both units, and this effect was more pronounced in SYMPHONY 1.5T. Noncentrally located slice positions in the investigated volume of the phantom were associated with larger distortions. Object. The authors sought to compare the accuracy of stereotactic target imaging using the Siemens 1T EXPERT and 1.5T SYMPHONY magnetic resonance (MR) units. Methods. A water-filled cylindrical Perspex phantom with axial and coronal inserts containing grids of glass rods was fixed in the Leksell stereotactic frame and subjected to MR imaging in Siemens 1T EXPERT and Siemens 1.5T SYMPHONY units. Identical sequences were used for each unit. The images were transferred to the GammaPlan treatment planning system. Deviations between stereotactic coordinates based on MR images and estimated real geometrical positions given by the construction of the phantom insert were evaluated for each study. The deviations were further investigated as a function of the MR unit used, MR sequence, the image orientation, and the spatial position of measured points in the investigated volume. Conclusions. Larger distortions were observed when using the SYMPHONY 1.5T unit than those with the EXPERT 1T unit. Typical average distortion in EXPERT 1T was not more than 0.6 mm and 0.9 mm for axial and coronal images, respectively. Typical mean distortion for SYMPHONY 1.5T was not more than 1 mm and 1.3 mm for axial and coronal images, respectively. The image sequence affected the distortions in both units. Coronal T2-weighted spin-echo images performed in subthalamic imaging produced the largest distortions of 2.6 mm and 3 mm in the EXPERT 1T and SYMPHONY 1.5T, respectively. Larger distortions were observed in coronal slices than in axial slices in both units, and this effect was more pronounced in SYMPHONY 1.5T. Noncentrally located slice positions in the investigated volume of the phantom were associated with larger distortions.
- 1 January 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102 (Special_Su) , 8-13
Does new magnetic resonance imaging technology provide better geometrical accuracy during stereotactic imaging?
Object. The authors sought to compare the accuracy of stereotactic target imaging using the Siemens 1T EXPERT and 1.5T SYMPHONY magnetic resonance (MR) units. Methods. A water-filled cylindrical Perspex phantom with axial and coronal inserts containing grids of glass rods was fixed in the Leksell stereotactic frame and subjected to MR imaging in Siemens 1T EXPERT and Siemens 1.5T SYMPHONY units. Identical sequences were used for each unit. The images were transferred to the GammaPlan treatment planning system. Deviations between stereotactic coordinates based on MR images and estimated real geometrical positions given by the construction of the phantom insert were evaluated for each study. The deviations were further investigated as a function of the MR unit used, MR sequence, the image orientation, and the spatial position of measured points in the investigated volume. Conclusions. Larger distortions were observed when using the SYMPHONY 1.5T unit than those with the EXPERT 1T unit. Typical average distortion in EXPERT 1T was not more than 0.6 mm and 0.9 mm for axial and coronal images, respectively. Typical mean distortion for SYMPHONY 1.5T was not more than 1 mm and 1.3 mm for axial and coronal images, respectively. The image sequence affected the distortions in both units. Coronal T2-weighted spin-echo images performed in subthalamic imaging produced the largest distortions of 2.6 mm and 3 mm in the EXPERT 1T and SYMPHONY 1.5T, respectively. Larger distortions were observed in coronal slices than in axial slices in both units, and this effect was more pronounced in SYMPHONY 1.5T. Noncentrally located slice positions in the investigated volume of the phantom were associated with larger distortions. Object. The authors sought to compare the accuracy of stereotactic target imaging using the Siemens 1T EXPERT and 1.5T SYMPHONY magnetic resonance (MR) units. Methods. A water-filled cylindrical Perspex phantom with axial and coronal inserts containing grids of glass rods was fixed in the Leksell stereotactic frame and subjected to MR imaging in Siemens 1T EXPERT and Siemens 1.5T SYMPHONY units. Identical sequences were used for each unit. The images were transferred to the GammaPlan treatment planning system. Deviations between stereotactic coordinates based on MR images and estimated real geometrical positions given by the construction of the phantom insert were evaluated for each study. The deviations were further investigated as a function of the MR unit used, MR sequence, the image orientation, and the spatial position of measured points in the investigated volume. Conclusions. Larger distortions were observed when using the SYMPHONY 1.5T unit than those with the EXPERT 1T unit. Typical average distortion in EXPERT 1T was not more than 0.6 mm and 0.9 mm for axial and coronal images, respectively. Typical mean distortion for SYMPHONY 1.5T was not more than 1 mm and 1.3 mm for axial and coronal images, respectively. The image sequence affected the distortions in both units. Coronal T2-weighted spin-echo images performed in subthalamic imaging produced the largest distortions of 2.6 mm and 3 mm in the EXPERT 1T and SYMPHONY 1.5T, respectively. Larger distortions were observed in coronal slices than in axial slices in both units, and this effect was more pronounced in SYMPHONY 1.5T. Noncentrally located slice positions in the investigated volume of the phantom were associated with larger distortions.
- Open Access
- 1 January 2004
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3 (1) , 288-292
Application of polymer-gel dosimetry in stereotactic radiosurgery
Stereotactic irradiation with the Leksell gamma knife (Elekta Instrument AB, Stockholm, Sweden) is one of the primary methods used for the stereotactic radiosurgery treatment of intracranial lesions. To assure the quality of the whole treatment procedure a proper dosimetric system is required. The polymer-gel dosimeter evaluated by nuclear magnetic resonance (NMR) is a promising tool to satisfy this requirement. The purpose of this study was to investigate the use of polymer-gel dosimeter as a dosimetric tool for the quality control of stereotactic radiosurgery procedures performed by the Leksell gamma knife.
- 1 January 2004
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3 (1) , 288-292
Open AccessApplication of polymer-gel dosimetry in stereotactic radiosurgery
Stereotactic irradiation with the Leksell gamma knife (Elekta Instrument AB, Stockholm, Sweden) is one of the primary methods used for the stereotactic radiosurgery treatment of intracranial lesions. To assure the quality of the whole treatment procedure a proper dosimetric system is required. The polymer-gel dosimeter evaluated by nuclear magnetic resonance (NMR) is a promising tool to satisfy this requirement. The purpose of this study was to investigate the use of polymer-gel dosimeter as a dosimetric tool for the quality control of stereotactic radiosurgery procedures performed by the Leksell gamma knife.
- 1 December 2002
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 97 (Supplement) , 556-562
Application of polymer gel dosimetry in gamma knife radiosurgery
Object. The purpose of this study was to investigate the use of a polymer gel—based dosimeter for the evaluation of geometric and dosimetric inaccuracies during gamma knife radiosurgery and during the irradiation of an experimental animal. Methods. A polymer gel dosimeter, based on acrylic monomers, was used for experiments conducted in this study. The accuracy of the dosimeter was evaluated on a Siemens EXPERT 1-tesla scanner in the transmitter/receiver head coil with the use of a multiecho sequence with 16 echoes, TE 22.5 to 360 msec, TR 2000 msec, slice thickness 2 mm, field of view 255 mm, and a pixel size of 0.5 × 0.5 mm2. Two experiments were conducted. First, the head phantom containing the polymer gel dosimeter was irradiated using 4-, 8-, 14-, and 18-mm isocenters. Second, a specially designed rat phantom was irradiated by four 4-mm isocenters. The dose profiles in the x, y, and z axes were calculated in the treatment planning system and measured with the polymer gel dosimeter and the results were compared. There was good agreement between the measured and calculated dose profiles. The maximum deviation in the spatial position of the center of measured and calculated dose profiles was 0.5 mm in the head phantom and 1 mm in the rat phantom. The maximum deviation in the width of the selected reference isodose of measured profiles was 1.2 mm in the head phantom and 1.1 mm in the rat phantom. Conclusions. The use of the polymer gel—based dosimeter for the verification of stereotactic procedures has advantages compared with other dosimetric systems. The dosimeter itself is tissue equivalent. Three-dimensional dose distributions can be measured and the dosimeter allows simulation of the therapeutic procedures. Object. The purpose of this study was to investigate the use of a polymer gel—based dosimeter for the evaluation of geometric and dosimetric inaccuracies during gamma knife radiosurgery and during the irradiation of an experimental animal. Methods. A polymer gel dosimeter, based on acrylic monomers, was used for experiments conducted in this study. The accuracy of the dosimeter was evaluated on a Siemens EXPERT 1-tesla scanner in the transmitter/receiver head coil with the use of a multiecho sequence with 16 echoes, TE 22.5 to 360 msec, TR 2000 msec, slice thickness 2 mm, field of view 255 mm, and a pixel size of 0.5 × 0.5 mm2. Two experiments were conducted. First, the head phantom containing the polymer gel dosimeter was irradiated using 4-, 8-, 14-, and 18-mm isocenters. Second, a specially designed rat phantom was irradiated by four 4-mm isocenters. The dose profiles in the x, y, and z axes were calculated in the treatment planning system and measured with the polymer gel dosimeter and the results were compared. There was good agreement between the measured and calculated dose profiles. The maximum deviation in the spatial position of the center of measured and calculated dose profiles was 0.5 mm in the head phantom and 1 mm in the rat phantom. The maximum deviation in the width of the selected reference isodose of measured profiles was 1.2 mm in the head phantom and 1.1 mm in the rat phantom. Conclusions. The use of the polymer gel—based dosimeter for the verification of stereotactic procedures has advantages compared with other dosimetric systems. The dosimeter itself is tissue equivalent. Three-dimensional dose distributions can be measured and the dosimeter allows simulation of the therapeutic procedures.
- 1 December 2002
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 97 (Supplement) , 556-562
Application of polymer gel dosimetry in gamma knife radiosurgery
Object. The purpose of this study was to investigate the use of a polymer gel—based dosimeter for the evaluation of geometric and dosimetric inaccuracies during gamma knife radiosurgery and during the irradiation of an experimental animal. Methods. A polymer gel dosimeter, based on acrylic monomers, was used for experiments conducted in this study. The accuracy of the dosimeter was evaluated on a Siemens EXPERT 1-tesla scanner in the transmitter/receiver head coil with the use of a multiecho sequence with 16 echoes, TE 22.5 to 360 msec, TR 2000 msec, slice thickness 2 mm, field of view 255 mm, and a pixel size of 0.5 × 0.5 mm2. Two experiments were conducted. First, the head phantom containing the polymer gel dosimeter was irradiated using 4-, 8-, 14-, and 18-mm isocenters. Second, a specially designed rat phantom was irradiated by four 4-mm isocenters. The dose profiles in the x, y, and z axes were calculated in the treatment planning system and measured with the polymer gel dosimeter and the results were compared. There was good agreement between the measured and calculated dose profiles. The maximum deviation in the spatial position of the center of measured and calculated dose profiles was 0.5 mm in the head phantom and 1 mm in the rat phantom. The maximum deviation in the width of the selected reference isodose of measured profiles was 1.2 mm in the head phantom and 1.1 mm in the rat phantom. Conclusions. The use of the polymer gel—based dosimeter for the verification of stereotactic procedures has advantages compared with other dosimetric systems. The dosimeter itself is tissue equivalent. Three-dimensional dose distributions can be measured and the dosimeter allows simulation of the therapeutic procedures. Object. The purpose of this study was to investigate the use of a polymer gel—based dosimeter for the evaluation of geometric and dosimetric inaccuracies during gamma knife radiosurgery and during the irradiation of an experimental animal. Methods. A polymer gel dosimeter, based on acrylic monomers, was used for experiments conducted in this study. The accuracy of the dosimeter was evaluated on a Siemens EXPERT 1-tesla scanner in the transmitter/receiver head coil with the use of a multiecho sequence with 16 echoes, TE 22.5 to 360 msec, TR 2000 msec, slice thickness 2 mm, field of view 255 mm, and a pixel size of 0.5 × 0.5 mm2. Two experiments were conducted. First, the head phantom containing the polymer gel dosimeter was irradiated using 4-, 8-, 14-, and 18-mm isocenters. Second, a specially designed rat phantom was irradiated by four 4-mm isocenters. The dose profiles in the x, y, and z axes were calculated in the treatment planning system and measured with the polymer gel dosimeter and the results were compared. There was good agreement between the measured and calculated dose profiles. The maximum deviation in the spatial position of the center of measured and calculated dose profiles was 0.5 mm in the head phantom and 1 mm in the rat phantom. The maximum deviation in the width of the selected reference isodose of measured profiles was 1.2 mm in the head phantom and 1.1 mm in the rat phantom. Conclusions. The use of the polymer gel—based dosimeter for the verification of stereotactic procedures has advantages compared with other dosimetric systems. The dosimeter itself is tissue equivalent. Three-dimensional dose distributions can be measured and the dosimeter allows simulation of the therapeutic procedures.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 399-402
Medical Application of 3-D Polymer Gel Dosemeter Evaluated by Nuclear Magnetic Resonance
A polymer-gel dosemeter, which can be evaluated by nuclear magnetic resonance (NMR), was prepared and then a few samples were homogeneously irradiated by a Leksell gamma knife using an 18 mm collimator (60Co gamma photons) to obtain a calibration curve (NMR 1/T2 response to absorbed dose). To measure dose distribution from the Leksell gamma knife, a testing flask filled with the gel was fixed in the head phantom and then irradiated based on a calculated treatment plan. Evaluation of dosemeters was performed on a Siemans EXPERT 1T NMR scanner. Dose profiles in X, Y and Z coordinates through the ellipsoidal shape of the dose distribution were obtained to compare experimental results from the irradiated phantom with the treatment planning system calculations. The use of a polymer-gel dosemeter for a verification of stereotactic procedures has some unique advantages which can be summarised as follows: (1) the dosemeter itself is tissue equivalent, (2) three-dimensional dose distributions can be measured, (3) the dosemeter allows patient's procedures to be simulated without any limitations.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 399-402
Medical Application of 3-D Polymer Gel Dosemeter Evaluated by Nuclear Magnetic Resonance
A polymer-gel dosemeter, which can be evaluated by nuclear magnetic resonance (NMR), was prepared and then a few samples were homogeneously irradiated by a Leksell gamma knife using an 18 mm collimator (60Co gamma photons) to obtain a calibration curve (NMR 1/T2 response to absorbed dose). To measure dose distribution from the Leksell gamma knife, a testing flask filled with the gel was fixed in the head phantom and then irradiated based on a calculated treatment plan. Evaluation of dosemeters was performed on a Siemans EXPERT 1T NMR scanner. Dose profiles in X, Y and Z coordinates through the ellipsoidal shape of the dose distribution were obtained to compare experimental results from the irradiated phantom with the treatment planning system calculations. The use of a polymer-gel dosemeter for a verification of stereotactic procedures has some unique advantages which can be summarised as follows: (1) the dosemeter itself is tissue equivalent, (2) three-dimensional dose distributions can be measured, (3) the dosemeter allows patient's procedures to be simulated without any limitations.
- 1 January 2002
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 79 (2) , 57-74
Evaluation of Geometric and Dosimetric Inaccuracies of Stereotactic Irradiation in the Rat Brain
Objective: To evaluate geometric and dosimetric inaccuracies in the irradiation of the rat brain with the Leksell Gamma Knife. Materials and Methods: Altogether t
- 1 January 2002
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 79 (2) , 57-74
Evaluation of Geometric and Dosimetric Inaccuracies of Stereotactic Irradiation in the Rat Brain
Objective: To evaluate geometric and dosimetric inaccuracies in the irradiation of the rat brain with the Leksell Gamma Knife. Materials and Methods: Altogether t