HCHongjian Chen

Hongjian Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hongjian Chen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lipophilic Nutraceuticals

    by Yashu Chen, Hongjian Chen, Qianchun Deng, Long Chen, David Julian McClements, Ming Miao

    Nutraceuticals are considered as components originating from foods, which are publicized to have health promoting effects beyond normal nutritional function due to their specific molecular structures. Certain therapeutic claims still lack further validation using controlled human trials or other long-term efficacy tests, which needs further research. Lipophilic nutraceuticals, which have poor water solubility, instability, etc., reveal the challenges of encapsulating them into the food matrix with improved bioavailability. Several kinds of delivery systems with delicate design can achieve controlled release with improved burst and sustained release of the encapsulated bioactive components. This chapter focuses on the characteristics of lipophilic nutraceuticals and possible challenges in their delivery process, which may contribute to the understanding of the design principle of protective and effective delivery systems for chemically labile lipophilic nutraceuticals.

  • Open Access

    Pitting Judgment Model Based on Machine Learning and Feature Optimization Methods

    by Zhihao Qu, Dezhi Tang, Zhu Wang, Xiaqiao Li, Hongjian Chen, Yao Lv

    Pitting corrosion seriously harms the service life of oil field gathering and transportation pipelines, which is an important subject of corrosion prevention. In this study, we collected the corrosion data of pipeline steel immersion experiment and established a pitting judgment model based on machine learning algorithm. Feature reduction methods, including feature importance calculation and pearson correlation analysis, were first adopted to find the important factors affecting pitting. Then, the best input feature set for pitting judgment was constructed by combining feature combination and feature creation. Through receiver operating characteristic (ROC) curve and area under curve (AUC) calculation, random forest algorithm was selected as the modeling algorithm. As a result, the pitting judgment model based on machine learning and high dimensional feature parameters (i.e., material factors, solution factors, environment factors) showed good prediction accuracy. This study provided an effective means for processing high-dimensional and complex corrosion data, and proved the feasibility of machine learning in solving material corrosion problems.


  • Map Updating Revisited for Navigation Map : A mathematical way to perform map updating for autonomous mobile robot

    by Hongjian Chen, Zhiqiang Wang, Qing Zhu

    Simultaneous localization and mapping, SLAM can product a Map for autonomous robots and self-driving vehicle in navigation. In the actual environment, the scene changes frequently, which makes the old map no long reliable. Therefore, it is necessary to update such a map by an efficient and safely way. In this paper, we review the existing map updating, long-term localization methods and discuss about the challenges in this situation. We present a Map updating method in mathematical way which can update accurately. Our proposed method are tested in five indoor dataset and demonstrated feasibility.


  • Open Access

    A Study on the Acoustic Response of Pickering Perfluoropentane Droplets in Different Media

    by Ksenia Loskutova, Didrik Nimander, Isabelle Gouwy, Hongjian Chen, Morteza Ghorbani, Anna J. Svagan, Dmitry Grishenkov


  • On the Development of a Novel Contrast Pulse Sequence for Polymer-Shelled Microbubbles

    by Hongjian Chen, Dimitrios Evangelou, Ksenia Loskutova, Morteza Ghorbani, Dmitry Grishenkov

    Contrast agents are routinely used in ultrasound examinations. Nonlinear ultrasound imaging techniques have been developed over decades to enhance the contrast between the tissue and the blood pool after the injection of ultrasound contrast agents. In this study, we introduce a new contrast pulse sequence, CPS4. The CPS4 combines pulse inversion, sub-harmonic, and ultra-harmonic techniques to remove propagation distortion while capturing the unique sub-harmonic, and ultra-harmonic responses from ultrasound contrast agents. The novel CPS4 and conventional pulse inversion, sub-harmonic, and ultra-harmonic techniques were used to detect the presence of a research-grade, thick shell, polymer microbubble in a tissue-mimicking flow phantom. The contrast-to-tissue ratio (CTR) obtained from the applications of all techniques were compared. The results show that the highest CTR of approximately 16 dB was obtained using CPS4, which was superior to the individual reference techniques: pulse inversion, sub-harmonic, and ultra-harmonic techniques, at all scenarios considered in this study.


  • Open Access

    Effect of intensified cavitation using poly(vinyl alcohol) microbubbles on spray atomization characteristics in microscale

    by Taher Abbasiasl, Soroush Niazi, Araz Sheibani Aghdam, Hongjian Chen, Fevzi Çakmak Cebeci, Morteza Ghorbani, Dmitry Grishenkov, Ali Koşar

    In this study, cavitating flows inside a transparent cylindrical nozzle with an inner diameter of 0.9 mm were visualized, and the effect of cavitation on atomization characteristics of emerging sprays was investigated. Different patterns of cavitating flows inside the nozzle were visualized using a high-speed camera. In-house codes were developed to process the captured images to study the droplet size distribution and droplet velocity in different flow regimes. The results show that cavitating flows at the microscale have significant effects on atomization characteristics of the spray. Two working fluids, namely, water and poly(vinyl alcohol) microbubble (PVA MB) suspension, were employed. Accordingly, the injection pressures were detected as 690 kPa, 1035 kPa, and 1725 kPa for cavitation inception, supercavitation, and hydraulic flip flow regimes in the case of water, respectively. The corresponding pressures for the aforementioned patterns for PVA MB suspension were 590 kPa, 760 kPa, and 1070 kPa, respectively. At the microscale, as a result of a higher volume fraction of cavitation bubbles inside the nozzle, there is no large difference between the cavitation numbers corresponding to cavitating and hydraulic flip flows. Although the percentage of droplets with diameters smaller than 200 μm was roughly the same for both cases of water and PVA MB suspension, the Sauter mean diameter was considerably lower in the case of PVA MBs. Moreover, higher droplet velocities were achieved in the case of PVA MBs at lower injection pressures.


  • Intensifying cavitating flows in microfluidic devices with poly(vinyl alcohol) (PVA) microbubbles

    by Morteza Ghorbani, Hongjian Chen, Luis Guillermo Villanueva, Dmitry Grishenkov, Ali Koşar

    Cavitation and the energy associated with the collapse of resulting cavitation bubbles constitute an important research subject. The collapse of the hydrodynamic cavitation bubbles at the outlet of the flow elements leads to a high energy release and generates localized shock waves and a large temperature rise on exposed surfaces. The concept of “hydrodynamic cavitation on chip” is an emerging topic which emphasizes phase change phenomena in microscale and their utilizations in energy and biomedical applications. This study is aimed to investigate the potential of poly(vinyl alcohol) (PVA) Microbubbles (MBs) to generate cavitation bubbles and to evaluate their effects on flow regimes and energy dissipation. For this, three different microchannel configurations with different roughness elements were considered. The structural side wall and surface roughened channels were fabricated along with the smooth channel according to the techniques adopted from semiconductor based microfabrication. The upstream pressure varied from 1 to 7 MPa, and the flow patterns were recorded and analyzed using a high-speed camera. The pressure was locally measured at three locations along the microfluidic devices to determine the conditions for fully developed cavitating flows. The results were compared to the pure water case, and different trends for the cavitating flow pattern transitions were obtained for the water-PVA MB solution case. Accordingly, the twin cavity clouds extended to the end of the side wall roughened channel at a lower upstream pressure for the case of PVA MBs, while the smooth and surface roughened channels do not demonstrate this flow pattern. In addition, the cavitation number has the lowest values under the same working conditions for the case of PVA MBs. Moreover, the impact pressure generated by the bubble collapse inside the side wall roughened channel for the case of PVA MBs was notably higher than that for pure water.