JHJunji Higashiyama

Junji Higashiyama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junji Higashiyama has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermal Characterization of Human Head Models Exposed to Simultaneous Sub-6 GHz and Millimeter-Wave Exposures

    by Yuma Kobayashi, Akimasa Hirata, Ryota Ishioka, Takahiro Iyama, Junji Higashiyama, Yasunori Suzuki, Sachiko Kodera

  • Open Access

    Analysis of Actual Transmitted Power from Hundreds of FR2 Radio Base Stations over One Month in Urban Areas in Japan

    by Ryota Ishioka, Takahiro Iyama, Junji Higashiyama, Fumihiko Hada, Yasunori Suzuki, Satoshi Suyama

    This study analyzes the actual transmitted power from 5G beamforming radio base stations (BF-RBSs) to clarify the effectiveness and issues of an actual maximum approach specified in the International Electrotechnical Commission 62232:2025. The actual maximum approach is a new compliance assessment method for electromagnetic field exposure levels from BF-RBSs based on time-averaged transmitted power. In this study, the actual maximum transmitted power every 5 or 30 min from more than 400 BF-RBSs using millimeter waves in urban areas in Japan was collected using a network management system over a period of one month. For each BF-RBS, normalized actual transmitted power was derived as the ratio of actual to configured maximum transmitted power. As a result of this measurement, the maximum value of normalized actual transmitted power was approximately −3 dB when the number of sets of user equipment (UEs) in the BF-RBS was less than two with high data traffic. Moreover, statistical analysis results of the measurement data shows that the actual maximum approach may underestimate the electromagnetic field exposure levels from a BF-RBS with three or fewer UEs when the actual transmitted power of the BF-RBSs is not monitored and controlled to maintain a level below the threshold.


  • Open Access

    Dependency of Waveforms in Intermittent Transmission at Mobile Phone Frequencies on Electromagnetic Interference With Medical Devices

    by Takahiro Iyama, Ryota Ishioka, Junji Higashiyama, Yasunori Suzuki, Keisuke Nagase

    This study focuses on the effect of waveforms, i.e., signal length and period in intermittent transmission, for electromagnetic interference (EMI) on medical devices. It was already shown that the intermittent transmission with the period of 1 s (500 ms: ON and 500 ms: OFF) tends to cause EMI on medical devices compared to continuous transmission. To evaluate the impact of waveforms for EMI on medical devices, we conducted an experiment at 837.5 MHz and 1950 MHz using five medical devices that yielded the following results. For EMI dissipation, the input power of antenna simulating mobile phones increased and the separation distance between an antenna and medical device decreased as the signal length became shorter in the case of a signal length of less than 10 ms. On the other hand, the signal period exhibited no specific tendency regarding such power and distance. We confirmed that previous EMI tests, in which we used a radio signal with the length and period of 100 ms in intermittent transmission, were conservative from the viewpoint of waveforms. Results of this study indicate that the influence of EMI on medical devices does not depend on the average power but on the burst power. Based on this, EMI characteristics on medical devices for a certain radio system could be estimated based on previous EMI test results for other radio systems if their frequencies are close to each other and the signal specifications of them are clearly determined.


  • Open Access

    Power Absorption and Skin Temperature Rise From Simultaneous Near-Field Exposure at 2 and 28 GHz

    by Norika Miura, Sachiko Kodera, Yinliang Diao, Junji Higashiyama, Yasunori Suzuki, Akimasa Hirata

    In international guidelines and standards for human protection from electromagnetic fields, mass-averaged specific absorption rate (SAR) is used as a metric to prevent excessive temperature rise at frequencies from 100 kHz up to 6 GHz. Above this transition frequency, including the frequency region assigned to fifth-generation (5G) wireless communication systems, area-averaged absorbed power density (APD) or epithelial power density is used as a physical quantity to specify restrictions on human exposure. In 5G wireless systems, frequencies above and below 6 GHz may be used simultaneously. The effect of the superposition of SAR and APD on temperature rise should be considered, especially regarding the prevention of excessive surface temperature. Herein, we considered simultaneous exposure from inverted-F antenna and patch antenna array operating at 2 and 28 GHz, respectively. Computational results showed that the effect of superposition was marginal. This result is attributable to the heat diffusion length in biological tissues ( $\sim 10$ mm). The effect of the superposition was higher than 15% only when the patch antenna array and inverted-F antenna were separated by less than 50 mm for the 5 mm antenna-body separation.


  • Open Access

    Skin Temperature Elevation for Incident Power Densities From Dipole Arrays at 28 Ghz

    by Takuma Nakae, Daisuke Funahashi, Junji Higashiyama, Teruo Onishi, Akimasa Hirata

    The relationship between skin temperature elevation and incident power density (IPD) from radio-frequency near-field exposure at 28 GHz for different angles of incidence is evaluated computationally in this study. The averaging scheme of the IPD is crucial for determining the maximum allowable exposure levels of wireless equipment to comply with certain standards/regulations. However, it is still unclear which component of the IPD (i.e., the norm or normal component to the human body) is more related the temperature elevation. In the case of four-element dipole arrays, the distances between the model and the antenna were 15 and 30 mm in transverse-electric- and transverse-magnetic-like polarized waves, respectively, and in the case of eight-element dipole arrays, the distances were 45 mm from the center of the array. From our computational results for four- and eight-element dipole arrays, we confirmed that the normal component of the IPD provides better correlation with the surface skin temperature, regardless of angle of incidence, particularly for smaller angles of incidence (<30°). The enhancement of the ratio of the temperature increase to IPD was observed around the Brewster’s angle, which is mainly attributable to the difference in transmittance at the body surface. This exposure scenario may not occur as the antenna–human distance was too large to consider compliance at the closest distance. In terms of output power, the most restrictive condition for compliance is shown to be normal incidence, suggesting the importance of compliance for such exposure scenarios. Furthermore, the absorbed power density proved to be an appropriate metric to monitor in relation to skin temperature elevation.