Ryota Ishioka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryota Ishioka has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Junji Higashiyama
NTT DoCoMo
3 shared publications - Takahiro Iyama
NTT DOCOMO, Inc
3 shared publications - Yasunori Suzuki
NTT DoCoMo
3 shared publications - Akimasa Hirata
Nagoya Institute of Technology
1 shared publication - Fumihiko Hada
NTT DOCOMO, Inc., Yokosuka 239-8536, Japan
1 shared publication - Keisuke Nagase
Kanazawa University Hospital, Kanazawa, Japan
1 shared publication
Latest Publications
- Open Access
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (6) , 1507-1519
Thermal Characterization of Human Head Models Exposed to Simultaneous Sub-6 GHz and Millimeter-Wave Exposures
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (6) , 1507-1519
Open AccessThermal Characterization of Human Head Models Exposed to Simultaneous Sub-6 GHz and Millimeter-Wave Exposures
- Open Access
- 27 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4676
Analysis of Actual Transmitted Power from Hundreds of FR2 Radio Base Stations over One Month in Urban Areas in Japan
This study analyzes the actual transmitted power from 5G beamforming radio base stations (BF-RBSs) to clarify the effectiveness and issues of an actual maximum approach specified in the International Electrotechnical Commission 62232:2025. The actual maximum approach is a new compliance assessment method for electromagnetic field exposure levels from BF-RBSs based on time-averaged transmitted power. In this study, the actual maximum transmitted power every 5 or 30 min from more than 400 BF-RBSs using millimeter waves in urban areas in Japan was collected using a network management system over a period of one month. For each BF-RBS, normalized actual transmitted power was derived as the ratio of actual to configured maximum transmitted power. As a result of this measurement, the maximum value of normalized actual transmitted power was approximately −3 dB when the number of sets of user equipment (UEs) in the BF-RBS was less than two with high data traffic. Moreover, statistical analysis results of the measurement data shows that the actual maximum approach may underestimate the electromagnetic field exposure levels from a BF-RBS with three or fewer UEs when the actual transmitted power of the BF-RBSs is not monitored and controlled to maintain a level below the threshold.
- 27 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4676
Open AccessAnalysis of Actual Transmitted Power from Hundreds of FR2 Radio Base Stations over One Month in Urban Areas in Japan
This study analyzes the actual transmitted power from 5G beamforming radio base stations (BF-RBSs) to clarify the effectiveness and issues of an actual maximum approach specified in the International Electrotechnical Commission 62232:2025. The actual maximum approach is a new compliance assessment method for electromagnetic field exposure levels from BF-RBSs based on time-averaged transmitted power. In this study, the actual maximum transmitted power every 5 or 30 min from more than 400 BF-RBSs using millimeter waves in urban areas in Japan was collected using a network management system over a period of one month. For each BF-RBS, normalized actual transmitted power was derived as the ratio of actual to configured maximum transmitted power. As a result of this measurement, the maximum value of normalized actual transmitted power was approximately −3 dB when the number of sets of user equipment (UEs) in the BF-RBS was less than two with high data traffic. Moreover, statistical analysis results of the measurement data shows that the actual maximum approach may underestimate the electromagnetic field exposure levels from a BF-RBS with three or fewer UEs when the actual transmitted power of the BF-RBSs is not monitored and controlled to maintain a level below the threshold.
- Open Access
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 21165-21173
Dependency of Waveforms in Intermittent Transmission at Mobile Phone Frequencies on Electromagnetic Interference With Medical Devices
This study focuses on the effect of waveforms, i.e., signal length and period in intermittent transmission, for electromagnetic interference (EMI) on medical devices. It was already shown that the intermittent transmission with the period of 1 s (500 ms: ON and 500 ms: OFF) tends to cause EMI on medical devices compared to continuous transmission. To evaluate the impact of waveforms for EMI on medical devices, we conducted an experiment at 837.5 MHz and 1950 MHz using five medical devices that yielded the following results. For EMI dissipation, the input power of antenna simulating mobile phones increased and the separation distance between an antenna and medical device decreased as the signal length became shorter in the case of a signal length of less than 10 ms. On the other hand, the signal period exhibited no specific tendency regarding such power and distance. We confirmed that previous EMI tests, in which we used a radio signal with the length and period of 100 ms in intermittent transmission, were conservative from the viewpoint of waveforms. Results of this study indicate that the influence of EMI on medical devices does not depend on the average power but on the burst power. Based on this, EMI characteristics on medical devices for a certain radio system could be estimated based on previous EMI test results for other radio systems if their frequencies are close to each other and the signal specifications of them are clearly determined.
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 21165-21173
Open AccessDependency of Waveforms in Intermittent Transmission at Mobile Phone Frequencies on Electromagnetic Interference With Medical Devices
This study focuses on the effect of waveforms, i.e., signal length and period in intermittent transmission, for electromagnetic interference (EMI) on medical devices. It was already shown that the intermittent transmission with the period of 1 s (500 ms: ON and 500 ms: OFF) tends to cause EMI on medical devices compared to continuous transmission. To evaluate the impact of waveforms for EMI on medical devices, we conducted an experiment at 837.5 MHz and 1950 MHz using five medical devices that yielded the following results. For EMI dissipation, the input power of antenna simulating mobile phones increased and the separation distance between an antenna and medical device decreased as the signal length became shorter in the case of a signal length of less than 10 ms. On the other hand, the signal period exhibited no specific tendency regarding such power and distance. We confirmed that previous EMI tests, in which we used a radio signal with the length and period of 100 ms in intermittent transmission, were conservative from the viewpoint of waveforms. Results of this study indicate that the influence of EMI on medical devices does not depend on the average power but on the burst power. Based on this, EMI characteristics on medical devices for a certain radio system could be estimated based on previous EMI test results for other radio systems if their frequencies are close to each other and the signal specifications of them are clearly determined.