MSMichael C. De Siena

Michael C. De Siena

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael C. De Siena has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ion Migration Enhances the Performance of Perovskite CsPbBr 3 γ‐Ray Detectors

    by Lei Pan, Khasim Saheb Bayikadi, Indra Raj Pandey, Sujita Karki, Zhifu Liu, John A. Peters, Michael De Siena, Duck Young Chung, Bruce W. Wessels, Mercouri G. Kanatzidis

    Uncontrolled ion migration is well‐known in perovskite‐based semiconductor devices. Here, it is shown that instead of being detrimental, ion migration can be used to enhance the performance of perovskite CsPbBr 3 semiconductor gamma‐ray detectors. Through the deliberate application of electrical biasing, ion migration is actively controlled to modify the metal‐CsPbBr 3 interface barrier height in devices with asymmetric electrodes. Ion migration plays a pivotal role in reducing bulk defects, as evidenced by the contact potential difference measurement, thermally stimulated current spectroscopy and photoluminescence measurements. The evidence suggests that biasing‐induced ion migration in CsPbBr 3 results in a reduction in electron traps and significant detector improvement. As biasing at elevated temperatures expedites ion migration, preconditioning the CsPbBr 3 crystals through reverse biasing is a promising strategy for enhancing their energy‐resolving performance.


  • Vapor Growth of All-Inorganic 2D Ruddlesden–Popper Lead- and Tin-Based Perovskites

    by Xinting Shuai, Siraj Sidhik, Mingrui Xu, Xiang Zhang, Michael De Siena, Laurent Pedesseau, Hao Zhang, Guanhui Gao, Anand B. Puthirath, Wenbin Li, et al.

    The 2D Ruddlesden-Popper (RP) perovskites Cs2PbI2Cl2 (Pb-based, n = 1) and Cs2SnI2Cl2 (Sn-based, n = 1) stand out as unique and rare instances of entirely inorganic constituents within the more expansive category of organic/inorganic 2D perovskites. These materials have recently garnered significant attention for their strong UV-light responsiveness, exceptional thermal stability, and theoretically predicted ultrahigh carrier mobility. In this study, we synthesized Pb and Sn-based n = 1 2D RP perovskite films covering millimeter-scale areas for the first time, utilizing a one-step chemical vapor deposition (CVD) method under atmospheric conditions. These films feature perovskite layers oriented horizontally relative to the substrate. Multilayered Cs3Pb2I3Cl4 (Pb-based, n = 2) and Cs3Sn2I3Cl4 (Sn-based, n = 2) films were also obtained for the first time, and their crystallographic structures were refined by combining X-ray diffraction (XRD) and density functional theory (DFT) calculations. DFT calculations and experimental optical spectroscopy support band-gap energy shifts related to the perovskite layer thickness. We demonstrate bias-free photodetectors using the Sn-based, n = 1 perovskite with reproducible photocurrent and a fast 84 ms response time. The present work not only demonstrates the growth of high-quality all-inorganic multilayered 2D perovskites via the CVD method but also suggests their potential as promising candidates for future optoelectronic applications.


  • Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr3 Single‐Crystal Semiconductor Detector

    by Lei Pan, Zhifu Liu, Claire Welton, Vladislav V. Klepov, John A. Peters, Michael C. De Siena, Alessandro Benadia, Indra Pandey, Antonino Miceli, Duck Young Chung, et al.

    Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 1010 photons s−1 mm−2 is reported. High‐quality solution‐grown CsPbBr3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr3/Au. A high reverse‐bias voltage of 1000 V (435 V mm−1) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm−2), which enables a high sensitivity larger than 10 000 µC Gyair−1 cm−2 and a simultaneous low detection limit of 22 nGyair s−1. The CsPbBr3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 106 to 1010 photons s−1 mm−2. Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr3.


  • Open Access

    Investigation of defects in melt and solution grown perovskite CsPbBr3 single crystals

    by Zhifu Liu, John A. Peters, Lei Pan, Vladislav Klepov, Michael De Siena, Alessandro Benadia, Duck Young Chung, Mercouri G. Kanatzidis, Bruce W. Wessels

    Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 1011 to 1 × 1016 cm−3. Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 1014 cm−3. The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. For an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 1011 cm−3.


  • Laser Scribing for Electrode Patterning of Perovskite Spectrometer-Grade CsPbBr3 Gamma-ray Detectors

    by Vladislav V. Klepov, Michael C. De Siena, Indra R. Pandey, Lei Pan, Khasim Saheb Bayikadi, Serkan Butun, Duck Young Chung, Mercouri G. Kanatzidis

    Making semiconductor radiation detectors that work at room temperature relies heavily on the deposition and pixelation of electrodes. Electrode patterning of perovskite solar cells widely implements laser scribing techniques, which is a convenient, scalable, and inexpensive technique. However, this method has not found its application in radiation detector patterning yet, and the question whether laser scribing can achieve high-quality patterns with minimum damage to a detector crystal and low interpixel cross-talk remains largely unanswered. To prove that laser scribing is a practical method for electrode patterning on perovskite CsPbBr3 detectors, we use the material to create a variety of patterns. A very low lateral leakage current (60 nA at 10 V) and high mobility-lifetime product (9.7(3) × 10-4 cm2/V) were observed between the pixel and the guard ring in tests of single-pixel devices with a separation of 200 or 100 μm between the central electrode and the guard ring. The 122 and 136 keV photopeaks in 57Co gamma-ray spectra were very well resolved with an energy resolution of up to 6.1% at 122 keV. A further reduction in gap size to 50 μm is conceivable, but more process optimization is needed.


  • Short Aromatic Diammonium Ions Modulate Distortions in 2D Lead Bromide Perovskites for Tunable White-Light Emission

    by Ping Fu, Michael A. Quintero, Claire Welton, Xiaotong Li, Bruno Cucco, Michael C. De Siena, Jacky Even, George Volonakis, Mikaël Kepenekian, Runze Liu, et al.


  • Perovskite CsPbBr3 single crystal detector for high flux X-ray photon counting and synchrotron X-ray detection (Conference Presentation)

    by Lei Pan, Indra Pandey, Vladislav V. Klepov, Antonino Miceli, Yihui He, Michael C. De Siena, Duck Young Chung, Mercouri G. Kanatzidis

    Photon-Counting Detector (PCD) capable of resolving the energies of single X-ray photons is critical in medical imaging (e.g., Computed Tomography). A high count rate and negligible polarization is essential for a PCD. Besides, there has been a critical need to develop high-Z sensor for synchrotron X-ray facility. The very high X-ray fluxes (e.g., 1e6 – 1e12 photons/s/mm2) involved in both applications makes it very challenging for detector operation. Here, we demonstrate that our perovskite CsPbBr3 single crystal detectors have good performance for these applications.

  • Top Cited Papers

    Deterministic fabrication of 3D/2D perovskite bilayer stacks for durable and efficient solar cells

    by Siraj Sidhik, Yafei Wang, Michael De Siena, Reza Asadpour, Andrew J. Torma, Tanguy Terlier, Kevin Ho, Wenbin Li, Anand B. Puthirath, Xinting Shuai, et al.

    Realizing solution-processed heterostructures is a long-enduring challenge in halide perovskites because of solvent incompatibilities that disrupt the underlying layer. By leveraging the solvent dielectric constant and Gutmann donor number, we could grow phase-pure two-dimensional (2D) halide perovskite stacks of the desired composition, thickness, and bandgap onto 3D perovskites without dissolving the underlying substrate. Characterization reveals a 3D–2D transition region of 20 nanometers mainly determined by the roughness of the bottom 3D layer. Thickness dependence of the 2D perovskite layer reveals the anticipated trends for n-i-p and p-i-n architectures, which is consistent with band alignment and carrier transport limits for 2D perovskites. We measured a photovoltaic efficiency of 24.5%, with exceptional stability ofT99(time required to preserve 99% of initial photovoltaic efficiency) of >2000 hours, implying that the 3D/2D bilayer inherits the intrinsic durability of 2D perovskite without compromising efficiency.


  • Open Access

    Defect levels in CsPbCl3 single crystals determined by thermally stimulated current spectroscopy

    by John A. Peters, Zhifu Liu, Michael C. De Siena, Mercouri G. Kanatzidis, Bruce W. Wessels

    Thermally stimulated current (TSC) spectroscopy was used to characterize electronic trap states in the perovskite CsPbCl3 bulk single crystals which are promising for gamma ray detection. The TSC spectra indicate the presence of multiple traps over the temperature range from 80 K to above room temperature. The possible analytical defects identified were VCs and VCl vacancies and Pbi interstitials that have concentrations of the order of 1011−1016 cm−3 and capture cross sections of ∼10−18 cm2. A comparison of crystals grown from different ingots reveals that the concentration of defects in the crystal with an improved growth procedure is about one to four orders of magnitude less than those of a crystal from an earlier growth process. A further reduction and elimination of trap states within the perovskite ingot should lead to crystals with improved mobilities, carrier lifetimes, and detector response characteristics.


  • Perovskite CsPbBr3 Single Crystal Detector for High Flux X-Ray Photon Counting

    by Lei Pan, Yihui He, Vladislav V. Klepov, Michael C. De Siena, Mercouri G. Kanatzidis

    X-ray photon-counting detectors capable of resolving the energies of single X-ray photons are critical in medical imaging, and a high count rate is essential for photon-counting detectors. Here, we report the performance of the perovskite CsPbBr3 single-crystal semiconductor detector for X-ray photon counting. The CsPbBr3 detector noise floor, energy response linearity, energy resolution, count rate, and polarization were evaluated. By fine-tuning the detector working conditions, our CsPbBr3 detector with a planar electrode can count an incident X-ray photon rate of ~ 0.099 and ~ 0.336 Mcps/pixel at 10% and 30% deadtime loss, respectively, with corresponding energy resolutions of ~ 18% at 59.5 keV and ~ 12% at 122 keV at same pulse processing conditions. We also demonstrated that our CsPbBr3 detectors show negligible polarization under an X-ray flux of ~ 0.45 M photons/s/mm2 for the typical timescale of multiple clinical X-ray scans, such as 1 s – 100 s. Our evaluation demonstrates the high potential of CsPbBr3 detectors for Xray photon-counting applications in medical and industrial diagnostics with a lower cost than the current state-of-theart.