GXGuanjun Xu

Guanjun Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guanjun Xu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Wulin Li

    Fujian Provincial Key Laboratory of Cancer Metastasis Chemoprevention and Chemotherapy, College of Chemistry, Fuzhou University, Fuzhou 350108, China

    2 shared publications
  • Yingyu Liang

    School of Mechanical and Electrical Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China

    2 shared publications
  • Cong Wang

    School of Mechanical and Electrical Engineering, China University of Mining and Technology-Beijing, Beijing, China

    1 shared publication
  • Zhengjie Lu

    School of Mechanical Electronic and Information Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China

    1 shared publication

Latest Publications

  • Open Access

    Performance Problem of Current Differential Protection of Lines Emanating from Photovoltaic Power Plants

    by Yingyu Liang, Wulin Li, Guanjun Xu

    The amplitude and phase angle of the fault current in photovoltaic power plants (PVPPs) are significantly influenced by the control system of the grid-connected inverters, unlike in a conventional synchronous source. Hence, PVPPs may adversely affect the performance of the current differential protection designed for synchronous sources-based power grids. In order to study the performance problem of current differential protection on AC transmission lines, an analytical expression of the fault current in the PVPPs was deduced, and the fault current characteristic was extensively analyzed. Based on this analysis, the ratio of differential current over restraint current was initially derived in this study; this ratio is observed to be affected by the control system parameters, power grid system parameters, fault resistance, and fault types. Moreover, the dynamic characteristics of this ratio can be clearly observed based on a three-dimensional diagram. Furthermore, the operating performance of the current differential protection was analyzed under different influencing factors. The mathematical analysis presents that the amplitude ratio of the fault current on both sides of the line is larger than nine and that current differential protection will operate reliably in any case. Meanwhile, the theoretical analysis and simulation results show that the current phase angle difference may become an obtuse angle in case of an ungrounded fault, which will cause inaccurate operation of the current differential protection. The results of this study will provide guidance for the engineering application of current differential protection in case the PVPPs are connected to a power grid.


  • A New Distance Protection Scheme Based on Improved Virtual Measured Voltage

    by Yingyu Liang, Wulin Li, Zhengjie Lu, Guanjun Xu, Cong Wang

    Fault resistance causes conventional distance protection to operate incorrectly, threatening the safe operation of power system. The immunity to fault resistance is improved by utilizing fault-point voltage, measured current, and setting impedance to construct the virtual measured voltage. Then, a new distance protection scheme, known as protection scheme I, is presented to identify in-zone and out-of-zone faults by comparing the amplitudes of the original and virtual measured voltages. Then, the original and virtual measured voltages are improved by a special voltage phasor in phase with the fault-point voltage phasor. Based on the improved original and virtual measured voltages, another distance protection scheme is presented, namely protection scheme II. The two proposed protection schemes are immune to fault resistance and load current and operate well under all types of faults. However, protection scheme II has higher sensitivity to fault detection compared with protection scheme I. Simulation results verify the correctness and effectiveness of the two proposed schemes.