    Novel Specturi urine collector device demonstrating high measurement accuracy and proven clinical usability

    by Sylvia P. Nauta, Miranda van Berkel, Noor G.L. Nusselder, Tim Hundscheid, Christine H. Ten Hove, Joost G.J. Hoenderop, Petra A. van Setten

    Objectives: Urine collection from neonates and infants remains challenging. Non-invasive urine collection methods (UCMs) are preferred, but they are often associated with drawbacks, such as feces contamination, discomfort, and/or inaccurate urinary analysis. This study aimed to demonstrate the measurement accuracy and clinical usability of the Specturi urine collector device. Methods: 25 different urines were incubated in the Specturi urine collector device and three non-invasive UCMs, namely gauzes, urine collection bag, and PeeSpot, for 3 h at 37 °C. Albumin, calcium, chloride, creatinine, glucose, magnesium, phosphate, potassium, protein, sodium, and urea concentrations as well as osmolality and pH were measured in the extracted urines and compared to a control. The measurements were also compared between the different UCMs. In addition, a clinical pilot study was performed with the Specturi urine collector device to assess the usability and safety as indicated by nurses and parents. Results: The novel Specturi urine collector device offered accurate measurements of the various urinary analytes. Its measurement accuracy was comparable to the urine collection bag and PeeSpot and more accurate than gauzes. Nurses indicated that the Specturi urine collector device was easy to use, noting the ease of application and removal. Both nurses and parents indicated that the participants experienced no discomfort while wearing the Specturi urine collector device and no significant skin reactions were observed, unlike for other UCMs. Conclusions: The Specturi urine collector device is a novel non-invasive UCM, offering accurate urinary analysis, ensuring patient safety and comfort, and providing easy usage by nurses.

  • Open Access

    A novel urine collection device for accurate urinary measurements in neonates and pre-continent infants

    by Sylvia P. Nauta, Lieke A.E.A. Corbeek, Miranda van Berkel, Christine Ten Hove, Petra A. van Setten, Joost G. J. Hoenderop

    Urine collection from neonates and infants is challenging. All available urine collection methods (UCMs) have their disadvantages, like invasiveness, contamination, and/or inaccurate measurements of urinary components. This study aimed to demonstrate the accuracy of measurements of urinary components for the novel non-invasive 'Specturi urine collector device'. The urine collection textile was incubated under different conditions (incubation duration, temperature, and humidity) with either artificial or human urine. Concentrations of urinary components were compared before and after incubation. Because of suspected crystal formation, the effect of acidification was assessed in combination with crystal analysis. Urinary concentrations of calcium, magnesium, phosphate, sodium, creatinine, and protein, and pH were accurately measured, except for the calcium concentration in alkaline urines. The incubation conditions showed no to a small effect on the measurement of urinary components, which does not affect clinical decision-making. Crystals containing calcium, magnesium, and phosphorus formed on the textile after incubation with alkaline urine. Acidification recovered the calcium concentration in these urines. The non-invasive 'Specturi urine collector device' provides accurate measurements of urinary components under different conditions. This UCM is more accurate than other textile-based UCMs. Eventually, this device can be used as an accurate as well as patient- and staff-friendly UCM. All urine collection methods for neonates and pre-continent infants have their disadvantages, and textile-based urine collection methods provide inaccurate measurements of urinary components. Furthermore, the effect of changing environmental conditions on measurements of urinary components is unknown for these urine collection methods. This study introduces the 'Specturi urine collector device', a novel non-invasive urine collection device. This device provides accurate measurements for different urinary components under different conditions, like incubation duration, temperature, and humidity. The results show that the 'Specturi urine collector device' has the potential to become an alternative non-invasive urine collection method that is accurate, and patient- and staff-friendly.


  • Open Access

    Sample preparation of bone tissue for MALDI-MSI for forensic and (pre)clinical applications

    by Michiel Vandenbosch, Sylvia P. Nauta, Anastasiya Svirkova, Martijn Poeze, Ron M.A. Heeren, Tiffany Porta Siegel, Eva Cuypers, Martina Marchetti-Deschmann

    In the past decades, matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) has been applied to a broad range of biological samples, e.g., forensics and preclinical samples. The use of MALDI-MSI for the analysis of bone tissue has been limited due to the insulating properties of the material but more importantly the absence of a proper sample preparation protocol for undecalcified bone tissue. Undecalcified sections are preferred to retain sample integrity as much as possible or to study the tissue-bone bio interface in particular. Here, we optimized the sample preparation protocol of undecalcified bone samples, aimed at both targeted and untargeted applications for forensic and preclinical applications, respectively. Different concentrations of gelatin and carboxymethyl cellulose (CMC) were tested as embedding materials. The composition of 20% gelatin and 7.5% CMC showed to support the tissue best while sectioning. Bone tissue has to be sectioned with a tungsten carbide knife in a longitudinal fashion, while the sections need to be supported with double-sided tapes to maintain the morphology of the tissue. The developed sectioning method was shown to be applicable on rat and mouse as well as human bone samples. Targeted (methadone and EDDP) as well as untargeted (unknown lipids) detection was demonstrated. DHB proved to be the most suitable matrix for the detection of methadone and EDDP in positive ion mode. The limit of detection (LOD) is estimated to approximately 50 pg/spot on bone tissue. The protocol was successfully applied to detect the presence of methadone and EDDP in a dosed rat femur and a dosed human clavicle. The best matrices for the untargeted detection of unknown lipids in mouse hind legs in positive ion mode were CHCA and DHB based on the number of tissue-specific peaks and signal-to-noise ratios. The developed and optimized sample preparation method, applicable on animal and human bones, opens the door for future forensic and (pre)clinical investigations.


  • Open Access

    Clinical use of mass spectrometry (imaging) for hard tissue analysis in abnormal fracture healing

    by Sylvia P. Nauta, Martijn Poeze, Ron M.A. Heeren, Tiffany Porta Siegel

    Common traumas to the skeletal system are bone fractures and injury-related articular cartilage damage. The healing process can be impaired resulting in non-unions in 5–10% of the bone fractures and in post-traumatic osteoarthritis (PTOA) in up to 75% of the cases of cartilage damage. Despite the amount of research performed in the areas of fracture healing and cartilage repair as well as non-unions and PTOA, still, the outcome of a bone fracture or articular cartilage damage cannot be predicted. Here, we discuss known risk factors and key molecules involved in the repair process, together with the main challenges associated with the prediction of outcome of these injuries. Furthermore, we review and discuss the opportunities for mass spectrometry (MS) – an analytical tool capable of detecting a wide variety of molecules in tissues – to contribute to extending molecular understanding of impaired healing and the discovery of predictive biomarkers. Therefore, the current knowledge and challenges concerning MS imaging of bone and cartilage tissue as well as in vivo MS are discussed. Finally, we explore the possibilities of in situ, real-time MS for the prediction of outcome during surgery of bone fractures and injury-related articular cartilage damage.