Jiafu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiafu Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Haiming Shao
National Institute of Metrology, Beijing, China
9 shared publications - Chuansheng Li
National Institute of Metrology, Beijing, China
5 shared publications - Huanghui Zhang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications - Kun Wang
Division of Electromagnetic Metrology, National Institute of Metrology, Beijing, China
3 shared publications - Wei Zhao
VSL National Metrology Institute, Delft, The Netherlands
3 shared publications - Bin Li
Prime Science (Beijing) Technology Co., Ltd., Beijing 101102, China
1 shared publication
Latest Publications
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6929-6937
A Dual-Core Wide Bandwidth and High-Accuracy Fluxgate Current Sensor
A novel fluxgate current sensor scheme based on a dual-core configuration is proposed in this study. By integrating a direct current (DC) zero-flux detector, an alternating current (AC) zero-flux detector, and a secondary compensation coil module, a unified design of multi-coil and multi-signal processing circuits is achieved. Compared with conventional three-core fluxgate designs, the proposed approach offers a simplified structure while maintaining high bandwidth and high-accuracy measurement capabilities. A prototype was developed based on the proposed principles, which was subsequently evaluated through experiments. The results demonstrate that the sensor achieves a -3dB bandwidth exceeding 1.6 MHz. Within the frequency range of 10 Hz to 100 kHz, the amplitude response variation remains below 2%, and the phase deviation is within 2°. When benchmarked against a precision shunt resistor, the measurement error of 100 kHz AC current is maintained within 3%. The sensor also exhibits a step-response rise time of approximately 300 ns. These findings indicate that the proposed dual-core fluxgate sensor is well-suited for wideband current measurement applications demanding high dynamic performance and accuracy.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6929-6937
A Dual-Core Wide Bandwidth and High-Accuracy Fluxgate Current Sensor
A novel fluxgate current sensor scheme based on a dual-core configuration is proposed in this study. By integrating a direct current (DC) zero-flux detector, an alternating current (AC) zero-flux detector, and a secondary compensation coil module, a unified design of multi-coil and multi-signal processing circuits is achieved. Compared with conventional three-core fluxgate designs, the proposed approach offers a simplified structure while maintaining high bandwidth and high-accuracy measurement capabilities. A prototype was developed based on the proposed principles, which was subsequently evaluated through experiments. The results demonstrate that the sensor achieves a -3dB bandwidth exceeding 1.6 MHz. Within the frequency range of 10 Hz to 100 kHz, the amplitude response variation remains below 2%, and the phase deviation is within 2°. When benchmarked against a precision shunt resistor, the measurement error of 100 kHz AC current is maintained within 3%. The sensor also exhibits a step-response rise time of approximately 300 ns. These findings indicate that the proposed dual-core fluxgate sensor is well-suited for wideband current measurement applications demanding high dynamic performance and accuracy.
- Open Access
Nodal Carbon Emission Factor Prediction for Power Systems Based on MDBO-CNN-LSTM
Carbon emission estimation for power systems is essential for identifying emission responsibilities and formulating effective mitigation measures. Current carbon emission prediction methods for power systems exhibit limited computational efficiency and inadequate noise immunity under complex operating conditions. In this study, we address these limitations by improving population initialization, search mechanisms, and iteration strategies and developing a hybrid strategy Modified Dung Beetle Optimization (MDBO) algorithm. This led to the development of an MDBO-enhanced Convolutional Neural Network–Long Short-Term Memory (CNN-LSTM) network hybrid prediction model for carbon emission prediction. Firstly, the theoretical calculation mechanism of carbon emission flow in power systems is analyzed. Subsequently, an MDBO-CNN-LSTM deep network architecture is constructed, with detailed explanations of its fundamental structure and operational principles. Then, the proposed MDBO-CNN-LSTM model is utilized to predict the nodal carbon emission factor of power systems with the integration of renewable energy sources. Comparative experiments with conventional CNN-LSTM models are conducted on modified IEEE 30-, 118-, and 300-bus test systems. The results show that the maximum mean squared error of the proposed method does not exceed 0.5734% in the strong-noise scenario for the 300-bus system, which is reduced by half compared with the traditional method. The proposed method exhibits enhanced robustness under strong noise interference, providing a novel technical approach for precise carbon accounting in power systems.
Open AccessNodal Carbon Emission Factor Prediction for Power Systems Based on MDBO-CNN-LSTM
Carbon emission estimation for power systems is essential for identifying emission responsibilities and formulating effective mitigation measures. Current carbon emission prediction methods for power systems exhibit limited computational efficiency and inadequate noise immunity under complex operating conditions. In this study, we address these limitations by improving population initialization, search mechanisms, and iteration strategies and developing a hybrid strategy Modified Dung Beetle Optimization (MDBO) algorithm. This led to the development of an MDBO-enhanced Convolutional Neural Network–Long Short-Term Memory (CNN-LSTM) network hybrid prediction model for carbon emission prediction. Firstly, the theoretical calculation mechanism of carbon emission flow in power systems is analyzed. Subsequently, an MDBO-CNN-LSTM deep network architecture is constructed, with detailed explanations of its fundamental structure and operational principles. Then, the proposed MDBO-CNN-LSTM model is utilized to predict the nodal carbon emission factor of power systems with the integration of renewable energy sources. Comparative experiments with conventional CNN-LSTM models are conducted on modified IEEE 30-, 118-, and 300-bus test systems. The results show that the maximum mean squared error of the proposed method does not exceed 0.5734% in the strong-noise scenario for the 300-bus system, which is reduced by half compared with the traditional method. The proposed method exhibits enhanced robustness under strong noise interference, providing a novel technical approach for precise carbon accounting in power systems.
- Open Access
A Wide-Bandwidth Inexpensive Current Sensor Based on the Signal Fusion of Tunneling Magnetoresistance and a Current Transformer
In technology and industrial production, many applications require wide-bandwidth current measurements. In this paper, a signal fusion scheme for a current sensor comprising tunneling magnetoresistance and a current transformer is proposed, achieving a flat frequency response in the DC to MHz range. The measurement principles in different cases of the scheme are introduced, and the total transfer function of the entire scheme is derived by analyzing each section separately. Furthermore, the feasibility and selected parameters of the scheme are verified through a systematic simulation utilizing the MATLAB software. Based on the proposed scheme, a group of principal prototypes are built to experimentally evaluate the bandwidth, amplitude and phase flatness, accuracy, sensitivity, and impulse response. The relative amplitude variation in the passband of the fusion sensor is less than 4%, and the estimated bandwidth of the fusion sensor is close to 17 MHz. The accuracy is better than 0.6%, even when measuring the current at 1 MHz, and the relative standard deviation is 5% when measuring the impulse signal. The sensors developed using this scheme, with a low financial cost, have advantages in many wide-bandwidth current measuring scenarios.
Open AccessA Wide-Bandwidth Inexpensive Current Sensor Based on the Signal Fusion of Tunneling Magnetoresistance and a Current Transformer
In technology and industrial production, many applications require wide-bandwidth current measurements. In this paper, a signal fusion scheme for a current sensor comprising tunneling magnetoresistance and a current transformer is proposed, achieving a flat frequency response in the DC to MHz range. The measurement principles in different cases of the scheme are introduced, and the total transfer function of the entire scheme is derived by analyzing each section separately. Furthermore, the feasibility and selected parameters of the scheme are verified through a systematic simulation utilizing the MATLAB software. Based on the proposed scheme, a group of principal prototypes are built to experimentally evaluate the bandwidth, amplitude and phase flatness, accuracy, sensitivity, and impulse response. The relative amplitude variation in the passband of the fusion sensor is less than 4%, and the estimated bandwidth of the fusion sensor is close to 17 MHz. The accuracy is better than 0.6%, even when measuring the current at 1 MHz, and the relative standard deviation is 5% when measuring the impulse signal. The sensors developed using this scheme, with a low financial cost, have advantages in many wide-bandwidth current measuring scenarios.
- Open Access
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 134126-134135
A Wideband Closed-Loop Residual Current Sensor Based on Self-Oscillating Fluxgate
The increasing switching frequency of inverters in new electric power technology causes leakage currents at tens or even hundreds of kHz, exceeding the measurement frequency range of conventional AC residual current sensors. In addition, the cost of residual current sensors developed specifically for DC is high, limiting further application promotion. Hence, this paper focuses on designing a wideband closed-loop residual current sensor based on self-excited oscillation fluxgate, which outperforms ordinary measurement methods. The sensor is developed through the optimization of demodulation circuits, and the increase of AC windings and the construction of excitation voltage regulating circuits. The DC residual current measurement accuracy of the sensor is better than 0.2%. The standard deviation of zero-point change is 0.0046 mA. The introduction of this innovative sensor not only enables precise and stable measurement of residual currents but also facilitates current monitoring in high-frequency applications. It can be fully applied in the field of power technology and will promote the development of efficient and reliable power systems.
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 134126-134135
Open AccessA Wideband Closed-Loop Residual Current Sensor Based on Self-Oscillating Fluxgate
The increasing switching frequency of inverters in new electric power technology causes leakage currents at tens or even hundreds of kHz, exceeding the measurement frequency range of conventional AC residual current sensors. In addition, the cost of residual current sensors developed specifically for DC is high, limiting further application promotion. Hence, this paper focuses on designing a wideband closed-loop residual current sensor based on self-excited oscillation fluxgate, which outperforms ordinary measurement methods. The sensor is developed through the optimization of demodulation circuits, and the increase of AC windings and the construction of excitation voltage regulating circuits. The DC residual current measurement accuracy of the sensor is better than 0.2%. The standard deviation of zero-point change is 0.0046 mA. The introduction of this innovative sensor not only enables precise and stable measurement of residual currents but also facilitates current monitoring in high-frequency applications. It can be fully applied in the field of power technology and will promote the development of efficient and reliable power systems.
- 17 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Bilateral Comparison of High-Voltage Capacitance and Dielectric Dissipation Factor at 50 Hz
NIM (National Institute of Metrology, China) and NMIA (National Measurement Institute, Australia) carried out a comparison program, which included low-voltage capacitance, the voltage dependence of high-voltage capacitance and the dielectric dissipation factor (DDF) at 50 Hz. The travelling standards included a low-voltage standard capacitor, a dissipation factor standard and a 100 kV compressed-gas capacitor. The capacitance and DDF of the standard capacitor, measured by the two institutes, agreed within 2 μF/F and 2×10 -6 , respectively, at 50 Hz and 500 V. DDF measurements at nominal values of 0.00000, 0.0001 and 0.001 agreed within 6×10 -6 at 50 Hz and 10 kV. The capacitance change of a 100 kV compressed-gas capacitor measured by the two institutes agreed within 2 μF/F over the voltage range from 10 kV to 100 kV. The success of the program proved comparisons using a re-filled high-voltage compressed gas capacitor and a low-voltage standard capacitor can be conveniently used to validate the complete traceability chain of the measurement of high-voltage capacitance at 50 Hz. The program also proved that DDF measurements with different implementations of traceability chain via capacitance and resistance would agree well within the uncertainties required by industrial measurements and a commercial DDF standard that has undergone international air travel would be sufficiently stable.
- 17 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Bilateral Comparison of High-Voltage Capacitance and Dielectric Dissipation Factor at 50 Hz
NIM (National Institute of Metrology, China) and NMIA (National Measurement Institute, Australia) carried out a comparison program, which included low-voltage capacitance, the voltage dependence of high-voltage capacitance and the dielectric dissipation factor (DDF) at 50 Hz. The travelling standards included a low-voltage standard capacitor, a dissipation factor standard and a 100 kV compressed-gas capacitor. The capacitance and DDF of the standard capacitor, measured by the two institutes, agreed within 2 μF/F and 2×10 -6 , respectively, at 50 Hz and 500 V. DDF measurements at nominal values of 0.00000, 0.0001 and 0.001 agreed within 6×10 -6 at 50 Hz and 10 kV. The capacitance change of a 100 kV compressed-gas capacitor measured by the two institutes agreed within 2 μF/F over the voltage range from 10 kV to 100 kV. The success of the program proved comparisons using a re-filled high-voltage compressed gas capacitor and a low-voltage standard capacitor can be conveniently used to validate the complete traceability chain of the measurement of high-voltage capacitance at 50 Hz. The program also proved that DDF measurements with different implementations of traceability chain via capacitance and resistance would agree well within the uncertainties required by industrial measurements and a commercial DDF standard that has undergone international air travel would be sufficiently stable.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Measurement Uncertainty in Voltage Coefficients for Compressed-Gas Capacitor Based on a Simplified Tilting Method
High-voltage compressed-gas capacitor is a type of precision equipment commonly used in high-voltage laboratories. The voltage dependence of capacitance, in other words, the voltage coefficient (VC) of capacitance, is an important factor to ensure the measurement accuracy of capacitors. The simplified tilting method (STM) derived from PTB, which provides a solution for measuring the VC of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure. However, it is not an easy work for most laboratories. In order to evaluate the VC based on the STM, a special experimental platform was developed. The high-voltage capacitor installed on the platform can be tilted and rotated at high voltage and can be remote-controlled. Based on the developed platform, the VC of a 350-kV high-voltage capacitor was measured. In order to verify, it was remeasured by the direct measurement method with a dummy high-voltage capacitor, and before that, the VC of the dummy capacitor was calibrated with a near zero-VC capacitor. The results show a good agreement, and the consistency of the measurement results is better than 1.2 $\times \,\,10^{-6}$ between the two methods. Furthermore, the evaluation of measurement uncertainty in the VC determination of capacitor based on STM is introduced in detail. The evaluation results show that the expanded uncertainty is significantly better than 2.0 $\times \,\,10^{-6}$ , $k =2$ .
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Measurement Uncertainty in Voltage Coefficients for Compressed-Gas Capacitor Based on a Simplified Tilting Method
High-voltage compressed-gas capacitor is a type of precision equipment commonly used in high-voltage laboratories. The voltage dependence of capacitance, in other words, the voltage coefficient (VC) of capacitance, is an important factor to ensure the measurement accuracy of capacitors. The simplified tilting method (STM) derived from PTB, which provides a solution for measuring the VC of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure. However, it is not an easy work for most laboratories. In order to evaluate the VC based on the STM, a special experimental platform was developed. The high-voltage capacitor installed on the platform can be tilted and rotated at high voltage and can be remote-controlled. Based on the developed platform, the VC of a 350-kV high-voltage capacitor was measured. In order to verify, it was remeasured by the direct measurement method with a dummy high-voltage capacitor, and before that, the VC of the dummy capacitor was calibrated with a near zero-VC capacitor. The results show a good agreement, and the consistency of the measurement results is better than 1.2 $\times \,\,10^{-6}$ between the two methods. Furthermore, the evaluation of measurement uncertainty in the VC determination of capacitor based on STM is introduced in detail. The evaluation results show that the expanded uncertainty is significantly better than 2.0 $\times \,\,10^{-6}$ , $k =2$ .
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-7
Resonance at the Front of Lightning Impulse Voltage Waveforms Caused by the Load Capacitor
During the impulse voltage comparison test, it is important to keep the waveforms smooth for obtaining consistent experiment results, especially for the front time parameter. However, steps or oscillations are often found on the front of the waveforms. The authors propose a theory that these oscillations can be caused by the resistors in the damped capacitive voltage divider, which often serves as the load capacitor in the impulse voltage generation circuit. The theoretical analysis, numerical simulation, and experimental results are performed, and a good agreement has been found in support of the proposed theory. Furthermore, the waveform parameters measured by two resistive reference standard systems were found to be influenced by the shape of the waveform and the oscillation on the front. It is recommended to avoid using a damped capacitive divider as the load capacitor but use an impulse capacitor with low equivalent series resistance instead. This would help to eliminate this common cause of oscillation on the front of the lightning impulse voltage waveform. Waveform uniformity and uncertainty of the result could then be improved during the comparison of reference measuring systems.
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-7
Resonance at the Front of Lightning Impulse Voltage Waveforms Caused by the Load Capacitor
During the impulse voltage comparison test, it is important to keep the waveforms smooth for obtaining consistent experiment results, especially for the front time parameter. However, steps or oscillations are often found on the front of the waveforms. The authors propose a theory that these oscillations can be caused by the resistors in the damped capacitive voltage divider, which often serves as the load capacitor in the impulse voltage generation circuit. The theoretical analysis, numerical simulation, and experimental results are performed, and a good agreement has been found in support of the proposed theory. Furthermore, the waveform parameters measured by two resistive reference standard systems were found to be influenced by the shape of the waveform and the oscillation on the front. It is recommended to avoid using a damped capacitive divider as the load capacitor but use an impulse capacitor with low equivalent series resistance instead. This would help to eliminate this common cause of oscillation on the front of the lightning impulse voltage waveform. Waveform uniformity and uncertainty of the result could then be improved during the comparison of reference measuring systems.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Mechanical Structure for fast Voltage Coefficients Determination of Compressed-gas Capacitor with Tilting Technic
In order to measure the voltage coefficients of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure based on the tilting method, an experimental platform was developed. The high-voltage capacitor installed on the platform could be titled and rotated at high voltage. Base on the developed experimental platform, the VC of a 350 kV highvoltage capacitor was measured by the tilting method.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Mechanical Structure for fast Voltage Coefficients Determination of Compressed-gas Capacitor with Tilting Technic
In order to measure the voltage coefficients of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure based on the tilting method, an experimental platform was developed. The high-voltage capacitor installed on the platform could be titled and rotated at high voltage. Base on the developed experimental platform, the VC of a 350 kV highvoltage capacitor was measured by the tilting method.
- Open Access
- 7 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 29188-29195
The Research on Additional Errors of Voltage Transformer Connected in Series
The series summation method is an important method in the calibration of the voltage coefficient (VC) of the standard voltage transformers (VTs), in which the key step is connecting a fullyinsulated VT and a semi-insulated VT in series, and comparing them with the third VT under test. Caused by the imperfect electrical shielding of the serially-wound VTs, additional errors are introduced in the calibration. By analyzing the cause of the additional errors in the serial connection of the VTs, two methods were designed in this paper to measure the additional errors. The proposed methods were harnessed to measure the additional errors for a serial connection of a 35 kV fully-insulated two-stage voltage transformer (TSVT) and a 35 kV semi-insulated TSVT. The results show that the two methods give a consistency of better than 1.0×10-6 in ratio error and 2.0 μrad in phase displacement, respectively. The accurate measurement of the series additional errors and the correction of them significantly improve the accuracy of the VC measurement of a 110 / √3 kV TSVT based on the series summation method. Furthermore, the VC measurement result is verified by the consistency of the series summation method with the series additional errors corrected and the high-voltage standard capacitor method.
- 7 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 29188-29195
Open AccessThe Research on Additional Errors of Voltage Transformer Connected in Series
The series summation method is an important method in the calibration of the voltage coefficient (VC) of the standard voltage transformers (VTs), in which the key step is connecting a fullyinsulated VT and a semi-insulated VT in series, and comparing them with the third VT under test. Caused by the imperfect electrical shielding of the serially-wound VTs, additional errors are introduced in the calibration. By analyzing the cause of the additional errors in the serial connection of the VTs, two methods were designed in this paper to measure the additional errors. The proposed methods were harnessed to measure the additional errors for a serial connection of a 35 kV fully-insulated two-stage voltage transformer (TSVT) and a 35 kV semi-insulated TSVT. The results show that the two methods give a consistency of better than 1.0×10-6 in ratio error and 2.0 μrad in phase displacement, respectively. The accurate measurement of the series additional errors and the correction of them significantly improve the accuracy of the VC measurement of a 110 / √3 kV TSVT based on the series summation method. Furthermore, the VC measurement result is verified by the consistency of the series summation method with the series additional errors corrected and the high-voltage standard capacitor method.