Wei Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Zhao has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Chuansheng Li
National Institute of Metrology, Beijing, China
4 shared publications - Gert Rietveld
University of Twente, Enschede, The Netherlands
3 shared publications - Haiming Shao
National Institute of Metrology, Beijing, China
3 shared publications - Jiafu Wang
Division of Electromagnetic Metrology, National Institute of Metrology, Beijing, China
3 shared publications Shili Chen
3 shared publicationsHaitao Yu
2 shared publications
Latest Publications
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Characterization and Application of Fiber-Optic Current Sensors for On-Site Calibration
Fiber-optic current sensors (FOCS) have significant potential as traceable references in metrological applications, yet their widespread adoption remains limited. Laboratory calibration and comparison are essential for establishing traceability and reliability under real-world conditions. This paper presents the operating principle of self-developed FOCSs and evaluates key performance metrics. It reports the first comparison among National Metrology Institutes (NMIs) for calibration and performance assessment of FOCSs, covering stability, accuracy, linearity, temperature dependence, and frequency response. The results demonstrate that self-developed FOCSs achieve an accuracy of 0.1 %, linearity of 0.03 % up to 4 kA at room temperature, and an error variation of less than 0.2 % across the temperature range −10 °C to 60 °C. The wideband FOCS exhibits a bandwidth exceeding 120 kHz. Furthermore, FOCSs were deployed for current measurements in a medium-voltage substation and compared against Hall-effect current sensors under operational conditions. Findings confirm that FOCSs meet performance requirements in practical environments, offering excellent repeatability and traceability for on-site calibration and highlighting their unique value in metrological applications.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Characterization and Application of Fiber-Optic Current Sensors for On-Site Calibration
Fiber-optic current sensors (FOCS) have significant potential as traceable references in metrological applications, yet their widespread adoption remains limited. Laboratory calibration and comparison are essential for establishing traceability and reliability under real-world conditions. This paper presents the operating principle of self-developed FOCSs and evaluates key performance metrics. It reports the first comparison among National Metrology Institutes (NMIs) for calibration and performance assessment of FOCSs, covering stability, accuracy, linearity, temperature dependence, and frequency response. The results demonstrate that self-developed FOCSs achieve an accuracy of 0.1 %, linearity of 0.03 % up to 4 kA at room temperature, and an error variation of less than 0.2 % across the temperature range −10 °C to 60 °C. The wideband FOCS exhibits a bandwidth exceeding 120 kHz. Furthermore, FOCSs were deployed for current measurements in a medium-voltage substation and compared against Hall-effect current sensors under operational conditions. Findings confirm that FOCSs meet performance requirements in practical environments, offering excellent repeatability and traceability for on-site calibration and highlighting their unique value in metrological applications.
- Open Access
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Establishment and Application of 1200-kV Lightning Impulse Voltage Reference Measuring System
The National Metrology Institute (NMI) of The Netherlands (VSL) developed a new 1200-kV reference measuring system for on-site calibration of lightning impulse (LI) voltage measuring systems. Improvement of the low-voltage grounding loop and triaxial signal transmission reduced oscillation ripples and enhanced the shielding of environmental high-frequency interference. Calibration and measurement capabilities are realized in the test voltage ( ${U}_{t}$ ), front time ( ${T}_{1}$ ), and time to half-value ( ${T}_{2}$ ) with uncertainties of 0.7%, 3.0%, and 1.5%, respectively, up to 600 kV and 1.2%, 5.0%, and 3.0%, respectively, up to 1200 kV for direct comparison calibration. With additional linearity experiments, VSL is now able to provide LI voltage calibrations on-site up to 3000 kV. The VSL system was used as the reference for calibration and tuning of a 4000-kV LI divider to improve its accuracy performance. A measurement campaign was held to compare different LI measuring systems and research the linearity of the measuring system up to 3000 kV. The comparison results confirmed the good performance of the VSL 1200-kV reference measuring system and also indicated that the 4000-kV measuring system was improved after calibration and tuning with the VSL reference system.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Open AccessEstablishment and Application of 1200-kV Lightning Impulse Voltage Reference Measuring System
The National Metrology Institute (NMI) of The Netherlands (VSL) developed a new 1200-kV reference measuring system for on-site calibration of lightning impulse (LI) voltage measuring systems. Improvement of the low-voltage grounding loop and triaxial signal transmission reduced oscillation ripples and enhanced the shielding of environmental high-frequency interference. Calibration and measurement capabilities are realized in the test voltage ( ${U}_{t}$ ), front time ( ${T}_{1}$ ), and time to half-value ( ${T}_{2}$ ) with uncertainties of 0.7%, 3.0%, and 1.5%, respectively, up to 600 kV and 1.2%, 5.0%, and 3.0%, respectively, up to 1200 kV for direct comparison calibration. With additional linearity experiments, VSL is now able to provide LI voltage calibrations on-site up to 3000 kV. The VSL system was used as the reference for calibration and tuning of a 4000-kV LI divider to improve its accuracy performance. A measurement campaign was held to compare different LI measuring systems and research the linearity of the measuring system up to 3000 kV. The comparison results confirmed the good performance of the VSL 1200-kV reference measuring system and also indicated that the 4000-kV measuring system was improved after calibration and tuning with the VSL reference system.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Measurement Uncertainty in Voltage Coefficients for Compressed-Gas Capacitor Based on a Simplified Tilting Method
High-voltage compressed-gas capacitor is a type of precision equipment commonly used in high-voltage laboratories. The voltage dependence of capacitance, in other words, the voltage coefficient (VC) of capacitance, is an important factor to ensure the measurement accuracy of capacitors. The simplified tilting method (STM) derived from PTB, which provides a solution for measuring the VC of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure. However, it is not an easy work for most laboratories. In order to evaluate the VC based on the STM, a special experimental platform was developed. The high-voltage capacitor installed on the platform can be tilted and rotated at high voltage and can be remote-controlled. Based on the developed platform, the VC of a 350-kV high-voltage capacitor was measured. In order to verify, it was remeasured by the direct measurement method with a dummy high-voltage capacitor, and before that, the VC of the dummy capacitor was calibrated with a near zero-VC capacitor. The results show a good agreement, and the consistency of the measurement results is better than 1.2 $\times \,\,10^{-6}$ between the two methods. Furthermore, the evaluation of measurement uncertainty in the VC determination of capacitor based on STM is introduced in detail. The evaluation results show that the expanded uncertainty is significantly better than 2.0 $\times \,\,10^{-6}$ , $k =2$ .
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Measurement Uncertainty in Voltage Coefficients for Compressed-Gas Capacitor Based on a Simplified Tilting Method
High-voltage compressed-gas capacitor is a type of precision equipment commonly used in high-voltage laboratories. The voltage dependence of capacitance, in other words, the voltage coefficient (VC) of capacitance, is an important factor to ensure the measurement accuracy of capacitors. The simplified tilting method (STM) derived from PTB, which provides a solution for measuring the VC of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure. However, it is not an easy work for most laboratories. In order to evaluate the VC based on the STM, a special experimental platform was developed. The high-voltage capacitor installed on the platform can be tilted and rotated at high voltage and can be remote-controlled. Based on the developed platform, the VC of a 350-kV high-voltage capacitor was measured. In order to verify, it was remeasured by the direct measurement method with a dummy high-voltage capacitor, and before that, the VC of the dummy capacitor was calibrated with a near zero-VC capacitor. The results show a good agreement, and the consistency of the measurement results is better than 1.2 $\times \,\,10^{-6}$ between the two methods. Furthermore, the evaluation of measurement uncertainty in the VC determination of capacitor based on STM is introduced in detail. The evaluation results show that the expanded uncertainty is significantly better than 2.0 $\times \,\,10^{-6}$ , $k =2$ .
- Open Access
- 11 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Verification of a Capacitive Voltage Divider With 6- μ rad Uncertainty Up To 100 kV
A reference setup for system calibration of industrial transformer loss measurement (TLM) systems consists of three main components, a voltage divider, a current transformer, and a power meter, and their phase displacements should each not be more than 10 μrad to achieve an overall system uncertainty of better than 20 μW/VA. We have extensively verified the uncertainty level of the current-comparator-based capacitive voltage divider (CVD) used in the TLM reference setup of the Van Swinden Laboratorium (VSL), both from the component level and the system as a whole. Different practical conditions relevant for on-site measurements are considered, e.g., measurement cable lengths, cable types, and grounding. The verification measurement results show an agreement of better than (6 ± 6) × 10 -6 in ratio error and (4 ± 6) μrad in phase displacement between the CVD component and system calibrations up to 100 kV. Requirements for achieving this agreement are adequate grounding of the CVD and the use of triax cable between the high-voltage (HV) capacitor and the CVD low-voltage electronics in case large distances have to be covered on-site. The (4±6) μrad agreement in phase displacement is well within the required 10 μrad limit for voltage measurements as part of on-site TLM system calibrations with 20 μW/VA overall uncertainty at low power factors.
- 11 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Open AccessVerification of a Capacitive Voltage Divider With 6- μ rad Uncertainty Up To 100 kV
A reference setup for system calibration of industrial transformer loss measurement (TLM) systems consists of three main components, a voltage divider, a current transformer, and a power meter, and their phase displacements should each not be more than 10 μrad to achieve an overall system uncertainty of better than 20 μW/VA. We have extensively verified the uncertainty level of the current-comparator-based capacitive voltage divider (CVD) used in the TLM reference setup of the Van Swinden Laboratorium (VSL), both from the component level and the system as a whole. Different practical conditions relevant for on-site measurements are considered, e.g., measurement cable lengths, cable types, and grounding. The verification measurement results show an agreement of better than (6 ± 6) × 10 -6 in ratio error and (4 ± 6) μrad in phase displacement between the CVD component and system calibrations up to 100 kV. Requirements for achieving this agreement are adequate grounding of the CVD and the use of triax cable between the high-voltage (HV) capacitor and the CVD low-voltage electronics in case large distances have to be covered on-site. The (4±6) μrad agreement in phase displacement is well within the required 10 μrad limit for voltage measurements as part of on-site TLM system calibrations with 20 μW/VA overall uncertainty at low power factors.
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-7
Resonance at the Front of Lightning Impulse Voltage Waveforms Caused by the Load Capacitor
During the impulse voltage comparison test, it is important to keep the waveforms smooth for obtaining consistent experiment results, especially for the front time parameter. However, steps or oscillations are often found on the front of the waveforms. The authors propose a theory that these oscillations can be caused by the resistors in the damped capacitive voltage divider, which often serves as the load capacitor in the impulse voltage generation circuit. The theoretical analysis, numerical simulation, and experimental results are performed, and a good agreement has been found in support of the proposed theory. Furthermore, the waveform parameters measured by two resistive reference standard systems were found to be influenced by the shape of the waveform and the oscillation on the front. It is recommended to avoid using a damped capacitive divider as the load capacitor but use an impulse capacitor with low equivalent series resistance instead. This would help to eliminate this common cause of oscillation on the front of the lightning impulse voltage waveform. Waveform uniformity and uncertainty of the result could then be improved during the comparison of reference measuring systems.
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-7
Resonance at the Front of Lightning Impulse Voltage Waveforms Caused by the Load Capacitor
During the impulse voltage comparison test, it is important to keep the waveforms smooth for obtaining consistent experiment results, especially for the front time parameter. However, steps or oscillations are often found on the front of the waveforms. The authors propose a theory that these oscillations can be caused by the resistors in the damped capacitive voltage divider, which often serves as the load capacitor in the impulse voltage generation circuit. The theoretical analysis, numerical simulation, and experimental results are performed, and a good agreement has been found in support of the proposed theory. Furthermore, the waveform parameters measured by two resistive reference standard systems were found to be influenced by the shape of the waveform and the oscillation on the front. It is recommended to avoid using a damped capacitive divider as the load capacitor but use an impulse capacitor with low equivalent series resistance instead. This would help to eliminate this common cause of oscillation on the front of the lightning impulse voltage waveform. Waveform uniformity and uncertainty of the result could then be improved during the comparison of reference measuring systems.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Mechanical Structure for fast Voltage Coefficients Determination of Compressed-gas Capacitor with Tilting Technic
In order to measure the voltage coefficients of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure based on the tilting method, an experimental platform was developed. The high-voltage capacitor installed on the platform could be titled and rotated at high voltage. Base on the developed experimental platform, the VC of a 350 kV highvoltage capacitor was measured by the tilting method.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Mechanical Structure for fast Voltage Coefficients Determination of Compressed-gas Capacitor with Tilting Technic
In order to measure the voltage coefficients of the high-voltage capacitor with compressed-gas coaxial cylindrical electrodes structure based on the tilting method, an experimental platform was developed. The high-voltage capacitor installed on the platform could be titled and rotated at high voltage. Base on the developed experimental platform, the VC of a 350 kV highvoltage capacitor was measured by the tilting method.
- 1 October 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 202, 846-853
Carboxyl functionalized gold nanoparticles in situ grown on reduced graphene oxide for micro-gravimetric ammonia sensing
- 1 October 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 202, 846-853
Carboxyl functionalized gold nanoparticles in situ grown on reduced graphene oxide for micro-gravimetric ammonia sensing
- 2 September 2014
- Published by Springer Nature in Microsystem Technologies
- Vol. 21 (9) , 1959-1965
A novel approach for MEMS with galvanic protection on SOI wafer
- 2 September 2014
- Published by Springer Nature in Microsystem Technologies
- Vol. 21 (9) , 1959-1965
A novel approach for MEMS with galvanic protection on SOI wafer
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1484-1486
A resonant micro-cantilever frequency tracking system based on dynamic phase difference
Gravimetric system based on resonant micro-cantilever had drawn significant attention in trace material detection. Adsorption quantity could be measured by the change of cantilever's resonant frequency, and phase-locked loop (PLL) was commonly used to keep the cantilever resonating. However, in the application of traditional PLL, we have to adjust parameters of the phase shifter to make sure the locked frequency matching with the cantilever's resonant frequency. In this manuscript, we promoted a frequency tracking system based on software phase-locked loop. Locked phase was calculated automatically, so the system could match with cantilevers of different resonant frequency, and no adjusting is need anymore. This system could combine with instruments based on frequency tracking and detection easily, not only limited to resonant cantilevers.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1484-1486
A resonant micro-cantilever frequency tracking system based on dynamic phase difference
Gravimetric system based on resonant micro-cantilever had drawn significant attention in trace material detection. Adsorption quantity could be measured by the change of cantilever's resonant frequency, and phase-locked loop (PLL) was commonly used to keep the cantilever resonating. However, in the application of traditional PLL, we have to adjust parameters of the phase shifter to make sure the locked frequency matching with the cantilever's resonant frequency. In this manuscript, we promoted a frequency tracking system based on software phase-locked loop. Locked phase was calculated automatically, so the system could match with cantilevers of different resonant frequency, and no adjusting is need anymore. This system could combine with instruments based on frequency tracking and detection easily, not only limited to resonant cantilevers.