Armin Kalita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Armin Kalita has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Claudiu Andrei Stan
Department of Physics, Rutgers University-Newark, Newark, NJ 07102, USA
1 shared publication - Daehyun You
Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577, Japan
1 shared publication - Gabriel Blaj
SLAC National Accelerator Laboratory, Sand Hill Road 2575, Menlo Park, California 94025, U.S.A.
1 shared publication - Kensuke Tono
Japan Synchrotron Radiation Research Institute, Hyogo, Japan
1 shared publication - Kiyoshi Ueda
Institute of Atomic and Molecular Physics and Jilin Provincial Key Laboratory of Applied Atomic and Molecular Spectroscopy, Jilin University, Changchun, China
1 shared publication - Koji Motomura
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo, Hyogo 679-5148, Japan
1 shared publication
Latest Publications
- Open Access
- 22 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (4) , 1497
The Magnitude and Waveform of Shock Waves Induced by X-ray Lasers in Water
The high energy densities deposited in materials by focused X-ray laser pulses generate shock waves which travel away from the irradiated region, and can generate complex wave patterns or induce phase changes. We determined the time-pressure histories of shocks induced by X-ray laser pulses in liquid water microdrops, by measuring the surface velocity of the microdrops from images recorded during the reflection of the shock at the surface. Measurements were made with ~30 µm diameter droplets using 10 keV X-rays, for X-ray pulse energies that deposited linear energy densities from 3.5 to 120 mJ/m; measurements were also made with ~60 µm diameter drops for a narrower energy range. At a distance of 15 µm from the X-ray beam, the peak shock pressures ranged from 44 to 472 MPa, and the corresponding time-pressure histories of the shocks had a fast quasi-exponential decay with positive pressure durations estimated to range from 2 to 5 ns. Knowledge of the amplitude and waveform of the shock waves enables accurate modeling of shock propagation and experiment designs that either maximize or minimize the effect of shocks.
- 22 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (4) , 1497
Open AccessThe Magnitude and Waveform of Shock Waves Induced by X-ray Lasers in Water
The high energy densities deposited in materials by focused X-ray laser pulses generate shock waves which travel away from the irradiated region, and can generate complex wave patterns or induce phase changes. We determined the time-pressure histories of shocks induced by X-ray laser pulses in liquid water microdrops, by measuring the surface velocity of the microdrops from images recorded during the reflection of the shock at the surface. Measurements were made with ~30 µm diameter droplets using 10 keV X-rays, for X-ray pulse energies that deposited linear energy densities from 3.5 to 120 mJ/m; measurements were also made with ~60 µm diameter drops for a narrower energy range. At a distance of 15 µm from the X-ray beam, the peak shock pressures ranged from 44 to 472 MPa, and the corresponding time-pressure histories of the shocks had a fast quasi-exponential decay with positive pressure durations estimated to range from 2 to 5 ns. Knowledge of the amplitude and waveform of the shock waves enables accurate modeling of shock propagation and experiment designs that either maximize or minimize the effect of shocks.