François Vurpillot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
François Vurpillot has a total of 190 co-authors. Here are the top co-authors by number of shared publications:
- Baptiste Gault
CNRS
10 shared publications Antoine Normand
GPM UMR 6634, CNRS, Université de Rouen Normandie, INSA Rouen Normandie, Normandie Université , F-76000 Rouen
9 shared publicationsConstantinos Hatzoglou
Department of Materials Science and Engineering NTNU Norwegian University of Science and Technology 7491 Trondheim Norway
6 shared publicationsFabien Delaroche
CNRS, INSA Rouen Normandie, Groupe de Physique des Matériaux, UMR 6634, Univ Rouen Normandie , Rouen F-76000, Avenue de l'Université, 76800 Saint-Étienne-du-Rouvray
6 shared publicationsAlfred Cerezo
Department of Materials, University of Oxford , Parks Rd, Oxford OX1 3PH
5 shared publications- Benjamin Klaes
CNRS, INSA Rouen Normandie, Groupe de Physique des Matériaux, UMR 6634, Univ Rouen Normandie, Rouen F-76000, France
5 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by Elsevier in Progress in Materials Science
- Vol. 165
Compositional metrology of atom probe applied to non-metallic materials
- 16 July 2026
- Published by Elsevier in Progress in Materials Science
- Vol. 165
Open AccessCompositional metrology of atom probe applied to non-metallic materials
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
From Stable Expansion to Catastrophic Failure Under Extreme Hydrogen Loading in Ni and Ti Atom Probe Tomography Specimens
To better understand hydrogen (H) trapping kinetics at the nanoscale, we recently introduced an approach consisting of in situ H implantation inside an atom probe analysis chamber operated at cryogenic temperature. This method enables implantation of H2+ ions with energies up to 1 keV, allowing H to penetrate approximately 10 nm beneath the surface of an atom probe tomography (APT) specimen. Here, we investigate the expansion of APT samples following H implantation in two metallic systems: nickel (Ni) and titanium (Ti). In Ni, a significant expansion of ≈10–15% was observed by comparing transmission electron microscopy images acquired before and after implantation. In Ti, expansion could not be directly imaged due to specimen degradation caused by room-temperature transfer; however, APT analyses revealed a substantial shift in evaporation voltage (10–40%), consistent with pronounced Ti tip volume expansion.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
From Stable Expansion to Catastrophic Failure Under Extreme Hydrogen Loading in Ni and Ti Atom Probe Tomography Specimens
To better understand hydrogen (H) trapping kinetics at the nanoscale, we recently introduced an approach consisting of in situ H implantation inside an atom probe analysis chamber operated at cryogenic temperature. This method enables implantation of H2+ ions with energies up to 1 keV, allowing H to penetrate approximately 10 nm beneath the surface of an atom probe tomography (APT) specimen. Here, we investigate the expansion of APT samples following H implantation in two metallic systems: nickel (Ni) and titanium (Ti). In Ni, a significant expansion of ≈10–15% was observed by comparing transmission electron microscopy images acquired before and after implantation. In Ti, expansion could not be directly imaged due to specimen degradation caused by room-temperature transfer; however, APT analyses revealed a substantial shift in evaporation voltage (10–40%), consistent with pronounced Ti tip volume expansion.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Using Detection Efficiency as an Indicator of Losses During Atom Probe Tomography Analysis of Oxygen-Rich Materials
Atom probe tomography (APT) enables atomic-scale compositional analysis in a wide range of materials; however, quantification in oxygen-rich materials remains challenging due to apparent oxygen losses during analysis. We present here a correlative method, combining transmission electron microscopy and analytical or numerical modeling, to estimate the APT analyzed volume and detection efficiency. Applied to CePO4 samples, the approach revealed that increasing laser pulse energy reduces detection efficiency, likely through enhanced neutral desorption. Analysis on pure aluminum confirmed the robustness of the method, while highlighting limitations in accurately determining the evaporated depth and compositional uncertainties. The results demonstrate consistent qualitative trends with known oxygen loss mechanisms in synthetic monazites. This work provides a foundation for developing a method to better understand the loss of neutral species during field evaporation and consequently the compositional biases observed in APT analyses. By linking morphological measurements with modeling of the analyzed volume, it opens the way to a more accurate interpretation of detection efficiency variations and elemental deficiencies in oxygen-rich materials.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Using Detection Efficiency as an Indicator of Losses During Atom Probe Tomography Analysis of Oxygen-Rich Materials
Atom probe tomography (APT) enables atomic-scale compositional analysis in a wide range of materials; however, quantification in oxygen-rich materials remains challenging due to apparent oxygen losses during analysis. We present here a correlative method, combining transmission electron microscopy and analytical or numerical modeling, to estimate the APT analyzed volume and detection efficiency. Applied to CePO4 samples, the approach revealed that increasing laser pulse energy reduces detection efficiency, likely through enhanced neutral desorption. Analysis on pure aluminum confirmed the robustness of the method, while highlighting limitations in accurately determining the evaporated depth and compositional uncertainties. The results demonstrate consistent qualitative trends with known oxygen loss mechanisms in synthetic monazites. This work provides a foundation for developing a method to better understand the loss of neutral species during field evaporation and consequently the compositional biases observed in APT analyses. By linking morphological measurements with modeling of the analyzed volume, it opens the way to a more accurate interpretation of detection efficiency variations and elemental deficiencies in oxygen-rich materials.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Determination of Electric Field in the Vicinity of Polarized Atom Probe Tomography Specimens Using Scanning Transmission Electron Microscopy
Determination of electrostatic field distribution at the nanometer scale at the vicinity of a polarized specimen is of great interest for solving the reconstruction issue in atom probe tomography. In this work, we present a method based on the Rutherford scattering theory to quantify the electric field maps obtained by scanning an electron beam across a needle-like specimen submitted to a high voltage in a transmission electron microscope. After a validation of the geometrical model on simulated datasets, electron beam-deflection maps were acquired in scanning mode using a holder developed to perform atom probe tomography experiments in transmission electron microscopes. The experimental results show that the determined electric field asymmetry is consistent with the local crystallographic configuration at the vicinity of a pure tungsten specimen. The methodology presented, which does not depend on the thickness of the sample, is anticipated to serve as an additional input for present and future atom probe reconstruction methods.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Determination of Electric Field in the Vicinity of Polarized Atom Probe Tomography Specimens Using Scanning Transmission Electron Microscopy
Determination of electrostatic field distribution at the nanometer scale at the vicinity of a polarized specimen is of great interest for solving the reconstruction issue in atom probe tomography. In this work, we present a method based on the Rutherford scattering theory to quantify the electric field maps obtained by scanning an electron beam across a needle-like specimen submitted to a high voltage in a transmission electron microscope. After a validation of the geometrical model on simulated datasets, electron beam-deflection maps were acquired in scanning mode using a holder developed to perform atom probe tomography experiments in transmission electron microscopes. The experimental results show that the determined electric field asymmetry is consistent with the local crystallographic configuration at the vicinity of a pure tungsten specimen. The methodology presented, which does not depend on the thickness of the sample, is anticipated to serve as an additional input for present and future atom probe reconstruction methods.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Frontiers of Atom Probe Tomography Physics, Data Processing, and Analysis
Atom probe tomography (APT) fills a crucial need in the characterization workflow of materials by its ability to inform the three-dimensional local composition at the nanoscale. As with any characterization technique, APT has strengths and limitations that inform the interpretation of the data. Therefore, a challenge for the materials characterization community, and the APT community in particular, is the need to establish repeatable and reproducible workflows around the APT data acquisition, reconstruction, analysis, and sharing, in order to inform interpretation. Data interpretation also requires the continued development of our understanding of the physical processes responsible for field evaporation. We review recent developments in the experimental analysis of field evaporation and in the modeling of field evaporation, leading to a new understanding of common artifacts observed in reconstructed data. We then discuss current challenges with data analysis, translation of results, and data interpretation in the absence of community-agreed standards, and therefore, the crucial need for standardization at every stage of APT research, from data collection all the way to data reporting. This perspective is a summary of the invited presentations and discussions that took place during a workshop (August 4–5, 2024, Alexandria, Virginia).
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Frontiers of Atom Probe Tomography Physics, Data Processing, and Analysis
Atom probe tomography (APT) fills a crucial need in the characterization workflow of materials by its ability to inform the three-dimensional local composition at the nanoscale. As with any characterization technique, APT has strengths and limitations that inform the interpretation of the data. Therefore, a challenge for the materials characterization community, and the APT community in particular, is the need to establish repeatable and reproducible workflows around the APT data acquisition, reconstruction, analysis, and sharing, in order to inform interpretation. Data interpretation also requires the continued development of our understanding of the physical processes responsible for field evaporation. We review recent developments in the experimental analysis of field evaporation and in the modeling of field evaporation, leading to a new understanding of common artifacts observed in reconstructed data. We then discuss current challenges with data analysis, translation of results, and data interpretation in the absence of community-agreed standards, and therefore, the crucial need for standardization at every stage of APT research, from data collection all the way to data reporting. This perspective is a summary of the invited presentations and discussions that took place during a workshop (August 4–5, 2024, Alexandria, Virginia).
- Open Access
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Spatial Resolution(s) in Atom Probe Tomography.
Atom probe tomography (APT) is often quoted to provide "atomic-scale" analysis of materials in three-dimensions. Despite efforts to quantify APT's spatial resolution, misunderstandings remain regarding its true spatial performance. If the depth resolution was once reported to be 20 pm, quoting this value outside of its specific context is misleading and should be avoided. The resolution achievable in pure metals, at one specific location, within one reconstructed dataset, does not generally apply across materials or analysis conditions, or even throughout a single tomographic reconstruction. Here, we review various efforts at defining and measuring the spatial resolution in the study of single phase and single element materials-i.e., pure metals-in field-ion microscopy (FIM) and APT. We also report on the degradation of the resolution arising from ion optical devices used to improve the mass-resolution. We aim to offer some perspective as to how reported resolutions may be or may not be of any relevance to most of the materials characterization efforts by APT, including cases of precipitates in a matrix that emphasize the need to consider an effective resolution. Finally, we discuss concepts to improve the spatial accuracy of the technique in a relatively distant future.
- 1 July 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (4)
Open AccessSpatial Resolution(s) in Atom Probe Tomography.
Atom probe tomography (APT) is often quoted to provide "atomic-scale" analysis of materials in three-dimensions. Despite efforts to quantify APT's spatial resolution, misunderstandings remain regarding its true spatial performance. If the depth resolution was once reported to be 20 pm, quoting this value outside of its specific context is misleading and should be avoided. The resolution achievable in pure metals, at one specific location, within one reconstructed dataset, does not generally apply across materials or analysis conditions, or even throughout a single tomographic reconstruction. Here, we review various efforts at defining and measuring the spatial resolution in the study of single phase and single element materials-i.e., pure metals-in field-ion microscopy (FIM) and APT. We also report on the degradation of the resolution arising from ion optical devices used to improve the mass-resolution. We aim to offer some perspective as to how reported resolutions may be or may not be of any relevance to most of the materials characterization efforts by APT, including cases of precipitates in a matrix that emphasize the need to consider an effective resolution. Finally, we discuss concepts to improve the spatial accuracy of the technique in a relatively distant future.
- 3 March 2026
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 10 (3)
Stochastic ion emission perturbation mechanisms in atom probe tomography: Linking simulations to experiment
- 3 March 2026
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 10 (3)
Stochastic ion emission perturbation mechanisms in atom probe tomography: Linking simulations to experiment
- Top Cited Papers
- 3 March 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (2)
Exploring Mechanisms Leading to Composition Errors in Monazite (CePO4) Analyzed With Atom Probe Tomography
Monazite (CePO4) is widely used in U–Th–Pb geochronology due to its reliable age determinations, although isotopic disturbances often require investigation at the nanoscale to better understand the mechanisms at play. Atom probe tomography (APT) offers unique capabilities for nanoscale chemical analysis and 3D atomic reconstruction but presents challenges for insulating materials such as CePO4, particularly due to oxygen loss during field evaporation. This study investigates the effects of laser wavelength, energy, metallic coatings, and detection device on mass spectrum optimization and compositional accuracy in synthetic CePO4 samples. Results show that shorter laser wavelengths (260 nm) enhance peak resolution, particularly when combined with advanced reflectron configurations, as demonstrated with the LEAP 6000 XR. Chromium coatings further improve thermal dissipation and reduce noise levels. However, compositional measurements reveal systematic underestimation of oxygen and overestimation of P and Ce, likely influenced by preferential low-field evaporation of certain elements. These findings highlight the need to carefully tune experimental parameters to mitigate quantification biases and enhance the reliability of APT analyses for geological materials.
- 3 March 2026
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 32 (2)
Top Cited PapersExploring Mechanisms Leading to Composition Errors in Monazite (CePO4) Analyzed With Atom Probe Tomography
Monazite (CePO4) is widely used in U–Th–Pb geochronology due to its reliable age determinations, although isotopic disturbances often require investigation at the nanoscale to better understand the mechanisms at play. Atom probe tomography (APT) offers unique capabilities for nanoscale chemical analysis and 3D atomic reconstruction but presents challenges for insulating materials such as CePO4, particularly due to oxygen loss during field evaporation. This study investigates the effects of laser wavelength, energy, metallic coatings, and detection device on mass spectrum optimization and compositional accuracy in synthetic CePO4 samples. Results show that shorter laser wavelengths (260 nm) enhance peak resolution, particularly when combined with advanced reflectron configurations, as demonstrated with the LEAP 6000 XR. Chromium coatings further improve thermal dissipation and reduce noise levels. However, compositional measurements reveal systematic underestimation of oxygen and overestimation of P and Ce, likely influenced by preferential low-field evaporation of certain elements. These findings highlight the need to carefully tune experimental parameters to mitigate quantification biases and enhance the reliability of APT analyses for geological materials.
- Top Cited Papers
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 19 (4) , 1025-1037
A Survey of AI in System of Systems With a Focus on Power Electronic Systems—Part II: Maintenance and Forecasting
Artificial intelligence (AI) is increasingly pivotal in modernizing the lifecycle of power electronic systems (PESs). Extending the discussion on the design and control phases presented in Part-I of the survey, Part II focuses on the transformative role of AI in the maintenance and forecasting phases of PES. Specifically, we analyze how AI techniques are applied to power electronic components, power electronic converters (PECs), and their emerging applications. This survey analyzes how AI techniques monitor PES’s health by detecting faults/anomalies, and estimating the remaining useful life (RUL), and in turn enable fault prevention before complete failure. Distinct from prior surveys, it also discusses soft-fault detection in complex wired networks such as aircraft, representing a system-of-systems application. In the context of forecasting, AI enables accurate prediction of PES parameters, such as power efficiency, thermal behavior, components’ lifetime, load demand, and energy generation. This survey identifies open challenges and provides forward-looking insight to guide researchers and engineers in developing robust, efficient, and autonomous maintenance and forecasting solutions for PES.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 19 (4) , 1025-1037
Top Cited PapersA Survey of AI in System of Systems With a Focus on Power Electronic Systems—Part II: Maintenance and Forecasting
Artificial intelligence (AI) is increasingly pivotal in modernizing the lifecycle of power electronic systems (PESs). Extending the discussion on the design and control phases presented in Part-I of the survey, Part II focuses on the transformative role of AI in the maintenance and forecasting phases of PES. Specifically, we analyze how AI techniques are applied to power electronic components, power electronic converters (PECs), and their emerging applications. This survey analyzes how AI techniques monitor PES’s health by detecting faults/anomalies, and estimating the remaining useful life (RUL), and in turn enable fault prevention before complete failure. Distinct from prior surveys, it also discusses soft-fault detection in complex wired networks such as aircraft, representing a system-of-systems application. In the context of forecasting, AI enables accurate prediction of PES parameters, such as power efficiency, thermal behavior, components’ lifetime, load demand, and energy generation. This survey identifies open challenges and provides forward-looking insight to guide researchers and engineers in developing robust, efficient, and autonomous maintenance and forecasting solutions for PES.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. PP (19328184) , 1-14
A Survey of AI in System of Systems With a Focus on Power Electronic Systems—Part I: Design and Control
Artificial intelligence (AI) has become essential in dealing with the growing complexities of modern power electronic systems (PESs). In the context of Industries 4.0, 5.0, and especially 6.0, which are considered as ultra-large-scale systems, AI is becoming essential in addressing the multidimensional challenges of PES design, energy management, and control in complex interconnected systems. This part I of our two-part survey provides a comprehensive overview of AI techniques applied to the design and control stages across the lifecycle of PES. In this survey, we consider an energy conversion chain incorporating energy sources, converters, controllers, sensors, and loads as a complex or a large system with several subsystems by integrating the AI part for several objectives among others: design, control, optimization, maintenance, fault detection, etc. Our unique contributions include: first, a complete lifecycle-oriented perspective for power electronics systems, second, structured tabular summaries emphasizing experimental validation versus simulation-only studies, third, focus on design automation and AI-integrated converter control, and fourth, identification of research gaps in hardware implementation and model interpretability. This survey also identifies open challenges and offers forward-looking insights into design automation, and AI-integrated converter control for smart grids, electric vehicles, and power systems. This article aims to serve as a roadmap for both researchers and engineers seeking to adopt AI in next-generation power electronics. Part II of this survey will focus on the maintenance and forecasting phases of the lifecycle of PES.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. PP (19328184) , 1-14
A Survey of AI in System of Systems With a Focus on Power Electronic Systems—Part I: Design and Control
Artificial intelligence (AI) has become essential in dealing with the growing complexities of modern power electronic systems (PESs). In the context of Industries 4.0, 5.0, and especially 6.0, which are considered as ultra-large-scale systems, AI is becoming essential in addressing the multidimensional challenges of PES design, energy management, and control in complex interconnected systems. This part I of our two-part survey provides a comprehensive overview of AI techniques applied to the design and control stages across the lifecycle of PES. In this survey, we consider an energy conversion chain incorporating energy sources, converters, controllers, sensors, and loads as a complex or a large system with several subsystems by integrating the AI part for several objectives among others: design, control, optimization, maintenance, fault detection, etc. Our unique contributions include: first, a complete lifecycle-oriented perspective for power electronics systems, second, structured tabular summaries emphasizing experimental validation versus simulation-only studies, third, focus on design automation and AI-integrated converter control, and fourth, identification of research gaps in hardware implementation and model interpretability. This survey also identifies open challenges and offers forward-looking insights into design automation, and AI-integrated converter control for smart grids, electric vehicles, and power systems. This article aims to serve as a roadmap for both researchers and engineers seeking to adopt AI in next-generation power electronics. Part II of this survey will focus on the maintenance and forecasting phases of the lifecycle of PES.