RKRemco J. J. Knol

Remco J. J. Knol

*This is an algorithmically generated author record based on publicly available information.

Remco J. J. Knol has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Detection of an inflammatory myofibroblastic tumor in the testis by FDG-PET/CT; a rare presentation of a rare neoplasm

    by Maurits Wondergem, Friso M. van der Zant, Lorine B. Meijer-Jorna, Siebe D. Bos, Remco J.J. Knol

  • Open Access

    The Role of Motion Correction Tools in Left Ventricular Functional Parameters Measured by Gated [13N]NH3 PET/CT

    by Tonantzin Samara Martinez-Lucio, Remco J. J. Knol, Oscar I. Mendoza-Ibañez, Lars van Wunnik, Friso M. van der Zant, Charalampos Tsoumpas, Riemer H. J. A. Slart, Sergiy V. Lazarenko

    Background/Objectives: Gated cardiac positron emission tomography (PET) synchronizes PET data to the cardiac cycle based on an electrocardiogram (ECG) signal, providing left ventricular (LV) functional and geometrical parameters. Nevertheless, image artifacts, due to cardiac-, breathing-, and/or patient-motion occurring during image acquisition, undermine the reliability and clinical utility of these parameters. This study aims to elucidate the effect of two motion correction (MC) tools, CardioFreeze (CF) and a data-driven motion correction (DDMC) prototype, on LV functional and geometrical parameters. Methods: ECG-gated rest/stress [13N]NH3 PET/CT scans from forty patients with myocardial ischemia and thirty-nine patients with normal myocardial perfusion were included. The following four reconstructions were performed for each patient scan: without motion correction (NMC), with CF, DDMC, and DDMC & CF. Images were processed with Cedars-Sinai QPET software. Results: End-diastolic volume (EDV) in rest and stress increased significantly using DDMC. End-systolic volume (ESV) increased significantly, while LV ejection fraction (LVEF) decreased significantly using any MC tool, regardless of the phase. Shape index end-systole (SI ES) and shape-index end-diastole (SI ED) increased significantly when using MC, except for SI ED in rest, where DDMC did not cause any difference. Eccentricity index end-systole (ECC ES) in rest and stress increased significantly in patients with normal myocardial perfusion, while it did not differ in ischemic patients after applying MC. Conclusions: MC tools significantly increase ESV values and decrease EF values. The highest effect is observed with the combined use of DDMC & CF. Image quality is greatly improved when using MC, regardless of the method, particularly in patients with the highest myocardial displacement.

  • Open Access

    Data-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans

    by Oscar Isaac Mendoza-Ibañez, Riemer H. J. A. Slart, Charles Hayden, Tonantzin Samara Martínez-Lucio, Friso M. van der Zant, Remco J. J. Knol, Sergiy V. Lazarenko

    Background: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [13N]NH3 and 82Rb PET/CT. This study aims to validate DDMC in dynamic [13N]NH3 PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. Methods: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. Results: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (p < 0.05), regardless of the MC method. Paired t-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the Z (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients’ subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. Conclusions: DDMC is feasible to perform in [13N]NH3 dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the Z-axis during stress scans negatively impacts stress-MBF quantification.


  • Open Access

    Inter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [13N]NH3 MPI PET/CT and the Effect of Motion Correction Tools

    by Oscar Isaac Mendoza-Ibañez, Riemer H. J. A. Slart, Erick Alexanderson-Rosas, Tonantzin Samara Martinez-Lucio, Friso M. van der Zant, Remco J. J. Knol, Sergiy V. Lazarenko

    Background: The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [13N]NH3 PET/CT scans. However, the impact of motion correction (MC) tools—integrated software motion correction (ISMC) or data-driven motion correction (DDMC)—on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. Methods: Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. Results: Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. Conclusions: MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.


  • Athletic Osteitis Pubis Detected on 18F-FDG PET/CT

    by Wouter A. M. Broos, Friso M. van der Zant, Remco J. J. Knol

    A 37-year-old male personal trainer presented with debilitating groin pains, fever, and night sweats. Enlarged inguinal lymph nodes were noticed during physical examination, and blood tests showed elevated erythrocyte sedimentation rate and C-reactive protein. 18F-FDG PET/CT excluded lymphoma and other malignancy but showed intense FDG uptake at the pubic symphysis and cortical erosions of the pubic bones on CT. The patient was diagnosed with osteitis pubis, an inflammatory condition of the pubic symphysis commonly seen in athletes. Treatment with anti-inflammatory drugs was initiated. Within several weeks, pain decreased, and inflammatory markers normalized.


  • Detection of Recurrent Prostate Cancer Using Prostate-specific Membrane Antigen Positron Emission Tomography in Patients not Meeting the Phoenix Criteria for Biochemical Recurrence After Curative Radiotherapy

    by Bernard H.E. Jansen, Pim J. van Leeuwen, Maurits Wondergem, Tim M. van der Sluis, Jakko A. Nieuwenhuijzen, Remco J.J. Knol, Reindert J.A. van Moorselaar, Henk G. van der Poel, Daniela E. Oprea-Lager, André N. Vis


  • Predicting cardiovascular risk traits from pet myocardial perfusion imaging with deep learning

    by L Juarez-Orozco, M.W Yeung, R.J.J Knol, J.W Benjamins, B Ruijsink, O Martinez-Manzanera, J Knuuti, F Asselbergs, F.M Van Der Zant, P Van Der Harst

    Background and aim: Deep Learning has revolutionised image analysis and its implementation in cardiology is rapidly advancing. DL offers the possibility to abstract highly-complex patterns from any image in order to optimise classification and prediction tasks. At the same time, positron emission tomography (PET) represents the reference technique for quantitative evaluation of myocardial perfusion and is a powerful tool for the diagnosis of myocardial ischemia and infarction. Although pathological perfusion patterns in PET are easily recognised by expert clinicians, it is unclear whether PET images harbour complex patterns inherent to traditional cardiovascular risk traits (factors) recognisable in an individual-patient basis. Hence, we aimed to deploy Deep Learning in order to predict cardiovascular risk traits from individual quantitative PET myocardial perfusion images. Methods: Data form 1180 patients evaluated through quantitative N13-ammonia PET-imaging for suspected myocardial ischemia was analysed. We implemented transfer learning with fine-tuning of individual concatenated instances of an ImageNet pre-trained convolutional neural network (ResNet-50). From each PET scan, the 3 standard quantitative polar maps (rest/stress/perfusion reserve) were used as network input. A 5-fold cross validation policy was applied to training and validation for hyperparameters optimisation. Deep Learning modelling was deployed to independently predict: sex, smoking, arterial hypertension, dyslipidemia and type 2 diabetes mellitus as cardiovascular risk traits. Final model performance was evaluated through AUC and accuracy (with associated standard deviations [SD]) on a hold-out test set of 104 scans. Deep Learning-based heat maps were generated to identify regions of interest in PET imaging related to each of the predicted risk trait Results: Deep Learning was able to strongly predict sex (0.87±0.04, 78%±4) and diabetes mellitus (0.75±0.13,71%±8), while its performance was only discrete for smoking (0.63±0.11, 85%±2), hypertension (0.61±0.06,58%±3) and dyslipidemia (0.59±0.05,57%±3), albeit all statistically significant (p<0.01). Conclusion: Deep Learning is able to significantly predict cardiovascular risk traits from individual quantitative PET myocardial perfusion images. This suggests the existence of complex high-dimensional and localised features within cardiac imaging that relate to cardiovascular risk factors at the individual level, which definitely warrants further research. Funding Acknowledgement: Type of funding source: None


  • Exercise Electrocardiogram Neither Predicts Nor Excludes Coronary Artery Disease in Women with Low to Intermediate Risk

    by Remco J.J. Knol, Huub Kan, Maurits Wondergem, Jan H. Cornel, Victor A.W.M. Umans, Tjeerd van der Ploeg, Friso M. van der Zant

    Aim: The value of exercise electrocardiogram (ExECG) in symptomatic female patients with low to intermediate risk for significant coronary artery disease (CAD) has been under debate for many years, and nondiagnostic or even erroneous test results are frequently encountered. Cardiac-CT may be more appropriate to exclude CAD in women. This study compares the results of ExECGs with those of cardiac-CTs, performed within a time frame of 1 month in an all-comers female chest pain population. Patients and Methods: Five hundred fifty-one consecutive female patients from a patient registry were included. ExECGs were negative in 324 (59%), positive in 14 (3%), and nondiagnostic in 213 (39%) patients. CAD was revealed by cardiac-CT in 57% of the women with negative ExECG. No signs of CAD were present on cardiac-CT in 64% of the women with a positive ExECG. Cardiac-CT showed presence of CAD in 268/551 (49%) patients, of whom 56/268 (21%) was diagnosed with ≥50% stenosis. The ExECG of the latter group was negative in 26 (46%), inconclusive in 29 (52%), and positive in 1 (2%). Considering ≥50% stenosis at cardiac-CT as the reference, sensitivity, specificity, PPV, and NPV of ExECG for the present population were 3.7%, 95.7%, 7.1%, and 91.7%, respectively. Similar diagnostic performance was calculated when considering ≥70% stenosis at cardiac-CT as the reference. Conclusion: ExECG failed to detect CAD in more than half of this cohort and in almost half of women with >50% stenosis at cardiac-CT. Importantly, no CAD was detected by cardiac-CT in 64% of women with a positive ExECG. ExECG is therefore questionable as a diagnostic strategy in women with low-to-intermediate risk of CAD, although prospective studies are warranted to determine whether replacing ExECG by cardiac-CT provides better prognoses.


  • Open Access

    Synthesis and In Vitro Evaluation of Novel Nortropane Derivatives as Potential Radiotracers for Muscarinic M2 Receptors

    by Remco J. J. Knol, Jan C. van Den Bos, Anton G. M. Janssen, Kora de Bruin, Berthe L. F. van Eck-Smit, Jan Booij

    Disturbances of the cerebral cholinergic neurotransmitter system are present in neurodegenerative disorders. SPECT or PET imaging, using radiotracers that selectively target muscarinic receptor subtypes, may be of value for in vivo evaluation of such conditions. 6β-acetoxynortropane, a potent muscarinic M2 receptor agonist, has previously demonstrated nanomolar affinity and high selectivity for this receptor. Based on this compound we synthesized four nortropane derivatives that are potentially suitable for SPECT imaging of the M2 receptor. 6β-acetoxynortropane and the novel derivatives were tested in vitro for affinity to the muscarinic M1−3 receptors. The original 6β-acetoxynortropane displayed high affinity (Ki=70–90 nM) to M2 receptors and showed good selectivity ratios to the M1 (65-fold ratio) and the M3 (70-fold ratio) receptors. All new derivatives showed reduced affinity to the M2 subtype and loss of subtype selectivity. It is therefore concluded that the newly synthesized derivatives are not suitable for human SPECT imaging of M2 receptors.