Sergiy V. Lazarenko
Research Subjects
Sergiy V. Lazarenko has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Friso M. van der Zant
From the Department of Nuclear Medicine, Noordwest Ziekenhuisgroep, Alkmaar, The Netherlands
3 shared publications - Oscar Isaac Mendoza-Ibañez
Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
3 shared publications - Remco J. J. Knol
Department of Nuclear Medicine, Northwest Clinics Alkmaar, 1815 JD Alkmaar, The Netherlands
3 shared publications - Riemer H. J. A. Slart
Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, the Netherlands
3 shared publications - Tonantzin Samara Martinez-Lucio
Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
3 shared publications - Charalampos Tsoumpas
University Medical Center Groningen, University of Groningen
1 shared publication
Latest Publications
- Open Access
- 1 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (9) , 1377
The Role of Motion Correction Tools in Left Ventricular Functional Parameters Measured by Gated [13N]NH3 PET/CT
Background/Objectives: Gated cardiac positron emission tomography (PET) synchronizes PET data to the cardiac cycle based on an electrocardiogram (ECG) signal, providing left ventricular (LV) functional and geometrical parameters. Nevertheless, image artifacts, due to cardiac-, breathing-, and/or patient-motion occurring during image acquisition, undermine the reliability and clinical utility of these parameters. This study aims to elucidate the effect of two motion correction (MC) tools, CardioFreeze (CF) and a data-driven motion correction (DDMC) prototype, on LV functional and geometrical parameters. Methods: ECG-gated rest/stress [13N]NH3 PET/CT scans from forty patients with myocardial ischemia and thirty-nine patients with normal myocardial perfusion were included. The following four reconstructions were performed for each patient scan: without motion correction (NMC), with CF, DDMC, and DDMC & CF. Images were processed with Cedars-Sinai QPET software. Results: End-diastolic volume (EDV) in rest and stress increased significantly using DDMC. End-systolic volume (ESV) increased significantly, while LV ejection fraction (LVEF) decreased significantly using any MC tool, regardless of the phase. Shape index end-systole (SI ES) and shape-index end-diastole (SI ED) increased significantly when using MC, except for SI ED in rest, where DDMC did not cause any difference. Eccentricity index end-systole (ECC ES) in rest and stress increased significantly in patients with normal myocardial perfusion, while it did not differ in ischemic patients after applying MC. Conclusions: MC tools significantly increase ESV values and decrease EF values. The highest effect is observed with the combined use of DDMC & CF. Image quality is greatly improved when using MC, regardless of the method, particularly in patients with the highest myocardial displacement.
- 1 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (9) , 1377
Open AccessThe Role of Motion Correction Tools in Left Ventricular Functional Parameters Measured by Gated [13N]NH3 PET/CT
Background/Objectives: Gated cardiac positron emission tomography (PET) synchronizes PET data to the cardiac cycle based on an electrocardiogram (ECG) signal, providing left ventricular (LV) functional and geometrical parameters. Nevertheless, image artifacts, due to cardiac-, breathing-, and/or patient-motion occurring during image acquisition, undermine the reliability and clinical utility of these parameters. This study aims to elucidate the effect of two motion correction (MC) tools, CardioFreeze (CF) and a data-driven motion correction (DDMC) prototype, on LV functional and geometrical parameters. Methods: ECG-gated rest/stress [13N]NH3 PET/CT scans from forty patients with myocardial ischemia and thirty-nine patients with normal myocardial perfusion were included. The following four reconstructions were performed for each patient scan: without motion correction (NMC), with CF, DDMC, and DDMC & CF. Images were processed with Cedars-Sinai QPET software. Results: End-diastolic volume (EDV) in rest and stress increased significantly using DDMC. End-systolic volume (ESV) increased significantly, while LV ejection fraction (LVEF) decreased significantly using any MC tool, regardless of the phase. Shape index end-systole (SI ES) and shape-index end-diastole (SI ED) increased significantly when using MC, except for SI ED in rest, where DDMC did not cause any difference. Eccentricity index end-systole (ECC ES) in rest and stress increased significantly in patients with normal myocardial perfusion, while it did not differ in ischemic patients after applying MC. Conclusions: MC tools significantly increase ESV values and decrease EF values. The highest effect is observed with the combined use of DDMC & CF. Image quality is greatly improved when using MC, regardless of the method, particularly in patients with the highest myocardial displacement.
- Open Access
- 26 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 984
Data-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans
Background: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [13N]NH3 and 82Rb PET/CT. This study aims to validate DDMC in dynamic [13N]NH3 PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. Methods: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. Results: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (p < 0.05), regardless of the MC method. Paired t-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the Z (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients’ subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. Conclusions: DDMC is feasible to perform in [13N]NH3 dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the Z-axis during stress scans negatively impacts stress-MBF quantification.
- 26 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (3) , 984
Open AccessData-Driven Motion Correction Algorithm: Validation in [13N]NH3 Dynamic PET/CT Scans
Background: Motion is a long-standing problem in cardiac PET/CT. An automated data-driven motion correction (DDMC) algorithm for within-reconstruction motion correction (MC) has been developed and validated in static images from [13N]NH3 and 82Rb PET/CT. This study aims to validate DDMC in dynamic [13N]NH3 PET/CT, and to explore the added value of DDMC in the evaluation of myocardial motion. Methods: Thirty-six PET/CT studies from normal patients and forty-three scans from patients with myocardial ischemia were processed using QPET software without MC (NMC), using manual in-software MC (ISMC), and DDMC. Differences in the mean values of rest-, stress-MBF, and CFR; and differences in effect size related to the use and type of MC method were explored. Moreover, motion vectors provided by DDMC were analyzed to evaluate differences in myocardial motion between scan phases and axes, and to elucidate changes in MBF quantification in relation to the motion extent. Results: In both subgroups, repeated measures ANOVA showed that the use of MC significantly increased regional and global stress-MBF and CFR values (p < 0.05), regardless of the MC method. Paired t-test analysis demonstrated a comparable ES between MC tools, despite minor differences in Cx, RCA and global rest-MBF values. High-intensity motion (>6 mm) proved to be present almost exclusively in the Z (cranio-caudal) direction. In the same axis, motion was significantly higher during stress than rest, regardless of patients’ subgroup. Finally, the Jonckheere trend test showed a significant trend caused by motion in s-MBF values, in which lower stress-MBF values were observed in response to motion extent increments. Conclusions: DDMC is feasible to perform in [13N]NH3 dynamic acquisitions and provides similar MBF/CFR values than manual ISMC. The use of DDMC reduces post-processing times and observer variability, and allows a more extensive evaluation of motion. MC is highly recommended when using QPET, as motion in the Z-axis during stress scans negatively impacts stress-MBF quantification.
- Open Access
- 4 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (5) , 613
Inter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [13N]NH3 MPI PET/CT and the Effect of Motion Correction Tools
Background: The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [13N]NH3 PET/CT scans. However, the impact of motion correction (MC) tools—integrated software motion correction (ISMC) or data-driven motion correction (DDMC)—on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. Methods: Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. Results: Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. Conclusions: MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.
- 4 March 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (5) , 613
Open AccessInter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [13N]NH3 MPI PET/CT and the Effect of Motion Correction Tools
Background: The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [13N]NH3 PET/CT scans. However, the impact of motion correction (MC) tools—integrated software motion correction (ISMC) or data-driven motion correction (DDMC)—on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. Methods: Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. Results: Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. Conclusions: MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.