Yang Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yang Dong has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Gongdong Zhu
Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Anhui 230031, China
1 shared publication - Gongdong Zhu
Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, HeFei 230031, China
1 shared publication - Jia-Jin Jason Chen
National Cheng Kung University
1 shared publication - Jingjing Wang
Jiangsu Normal Univ, Sch Phys & Elect Engn, Jiangsu Key Lab Adv Laser Mat & Devices, Xuzhou, Peoples R China
1 shared publication - Kun Liu
Chinese Academy of Sciences
1 shared publication - Mingsi Gu
Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
1 shared publication
Latest Publications
- Open Access
Fully Integrated Photoacoustic NO2 Sensor for Sub-ppb Level Measurement
A fully integrated photoacoustic nitrogen dioxide (NO2) sensor is developed and demonstrated. In this sensor, an embedded photoacoustic cell was manufactured by using an up-to-date 3D printing technique. A blue laser diode was used as a light source for excitation of photoacoustic wave in the photoacoustic cell. The photoacoustic wave is detected by a sensitive microelectromechanical system (MEMS) microphone. Homemade circuits are integrated into the sensor for laser diode driving and signal processing. The sensor was calibrated by using a chemiluminescence NO–NO2–NOX gas analyzer. And the performance of this sensor was evaluated. The linear relationship between photoacoustic signals and NO2 concentrations was verified in a range of below 202 ppb. The limit of detection was determined to 0.86 ppb with an integration time of 1 s. The corresponding normalized noise equivalent absorption was 2.0 × 10−8 cm−1∙W∙Hz−1/2. The stability and the optimal integration time were evaluated with an Allan deviation analysis, from which a detection limit of 0.25 ppb at the optimal integration time of 240 s was obtained. The sensor was used to measure outdoor air and the results agree with that obtained from the NO–NO2–NOX gas analyzer. The low-cost and portable photoacoustic NO2 sensor has a potential application for atmospheric NO2 monitoring.
Open AccessFully Integrated Photoacoustic NO2 Sensor for Sub-ppb Level Measurement
A fully integrated photoacoustic nitrogen dioxide (NO2) sensor is developed and demonstrated. In this sensor, an embedded photoacoustic cell was manufactured by using an up-to-date 3D printing technique. A blue laser diode was used as a light source for excitation of photoacoustic wave in the photoacoustic cell. The photoacoustic wave is detected by a sensitive microelectromechanical system (MEMS) microphone. Homemade circuits are integrated into the sensor for laser diode driving and signal processing. The sensor was calibrated by using a chemiluminescence NO–NO2–NOX gas analyzer. And the performance of this sensor was evaluated. The linear relationship between photoacoustic signals and NO2 concentrations was verified in a range of below 202 ppb. The limit of detection was determined to 0.86 ppb with an integration time of 1 s. The corresponding normalized noise equivalent absorption was 2.0 × 10−8 cm−1∙W∙Hz−1/2. The stability and the optimal integration time were evaluated with an Allan deviation analysis, from which a detection limit of 0.25 ppb at the optimal integration time of 240 s was obtained. The sensor was used to measure outdoor air and the results agree with that obtained from the NO–NO2–NOX gas analyzer. The low-cost and portable photoacoustic NO2 sensor has a potential application for atmospheric NO2 monitoring.
- 25 June 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (13) , 3298-3301
High-sensitivity off-axis integrated cavity output spectroscopy implementing wavelength modulation and white noise perturbation
In this Letter, a new method is proposed to further improve the detection sensitivity of the gas sensor based on off-axis integrated cavity spectroscopy (OA-ICOS) using a distributed feedback laser operating in the near-infrared at 1653 nm that relies on implementation of wavelength modulation and radio frequency (RF) white noise perturbation to diode laser current. More than sixfold improvement in detection limit is achieved for an RF noised wavelength-modulated OA-ICOS compared to the unperturbed conventional OA-ICOS approach.
- 25 June 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (13) , 3298-3301
High-sensitivity off-axis integrated cavity output spectroscopy implementing wavelength modulation and white noise perturbation
In this Letter, a new method is proposed to further improve the detection sensitivity of the gas sensor based on off-axis integrated cavity spectroscopy (OA-ICOS) using a distributed feedback laser operating in the near-infrared at 1653 nm that relies on implementation of wavelength modulation and radio frequency (RF) white noise perturbation to diode laser current. More than sixfold improvement in detection limit is achieved for an RF noised wavelength-modulated OA-ICOS compared to the unperturbed conventional OA-ICOS approach.