    Quantitative and objective full-field strain measurements of healthy human skin during distal upper extremity range of motion

    by Jonathan David López Lugo, Jorge Alejandro Benítez Martínez, Michelín Álvarez Camacho, Gerardo Leyva Gómez, Mariana Morales García, Carlos Palacios Morales, Francisco Manuel Sánchez Arévalo

    Traditional tools for assessing burns, such as the Vancouver Scar Scale and Cutometry, provide only subjective or localized mechanical evaluations. These methods lack the capacity to deliver comprehensive, objective data on skin deformation, particularly during dynamic movement. This study aims to demonstrate the utility of 3D-Digital Image Correlation (3D-DIC) as a non-invasive, quantitative technique for capturing full-field strain and displacement responses of the skin throughout the complete articular range of motion of the distal upper extremity. An in vivo experimental protocol was applied to a healthy subject to evaluate the mechanical behavior of the skin on the dorsal hand and volar forearm. 3D-DIC was used to quantify strain and displacement during metacarpophalangeal flexion (MF), composite fist (CF), wrist flexion (WF), and wrist extension (WE). Cutometry was also applied on volar and dorsal regions of the forearm to obtain comparative strain profiles under localized suction. 3D-DIC revealed semicircular skin recruitment patterns. Maximum displacements of 9 mm and 11 mm were observed for MF and CF, respectively, with corresponding maximum strains of 30 % and 35 %. During WF and WE, displacements ranged from 10-12 mm, with the highest strain localized near the radiocarpal joint. While Cutometry and 3D-DIC yielded different strain behaviors, the two methods proved complementary, enhancing the understanding of skin deformation under different mechanical stimuli. These findings suggest that 3D-DIC can serve as a robust, objective tool for evaluating skin mechanics in clinical and research settings, especially for applications involving scar assessment, surgical planning, and rehabilitation monitoring.

  • Hydrodynamic cavitation through a bio-inspired fast-closing plunger mechanism: experiments and simulations

    by F A Godínez, J E V Guzmán, M Salinas-Vázquez, R Valdés, C Palacios, O Chávez

    Experimental and numerical results are reported for the internal and external flow fields evolving in a bio-inspired snapping plunger. The experimental evidence underlines the nature of the dynamic-coupling between the processes taking place inside and outside the device. Two main structures dictate the properties of the external flow field: a strong jet which is followed by a vortex ring. Internally, complex patterns of cavitating structures are simultaneously produced in the chamber and the venturi-like conduit. We find the cavitation cycle to be suitably described by the Rayleigh–Plesset model and, thus, proceed to characterize the coupling of both fields in terms of the fluctuations of the velocity. All main parameters, as well as the energy released to the fluid during the collapse, are found to be within the same order-of-magnitude of previously known experimental results for isolated bubbles of comparable size.


  • On the maximum operating frequency of prosthetic heart valves

    by C A Palacios-Morales, Jose Enrique Vazquez Guzman, Alberto Beltran, Leopoldo Ruiz-Huerta, Alberto Caballero-Ruiz, Roberto Zenit

    A criterion is presented to evaluate the maximum pulsating flow frequency beyond which prosthetic heart valves cease to properly operate. The idea is tested with the experimental measurements obtained with an biological Edwards-Carpenter valve type model. It is found that beyond a certain characteristic frequency, the valve is no longer capable of fully operating in a cyclic manner. Furthermore, based on data recently reported by other authors, this preliminary comparison suggests that for a wide range of materials, leaflet sizes and operating conditions prosthetic heart valves might fail to properly operate for frequencies beyond 4.5 Hz (or 240 ppm).