Maxence Lavaill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maxence Lavaill has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Peter Pivonka
Affiliations Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Queensland, Australia, School of Mechanical Medical and Process Engineering, Faculty of Engineering, Queensland University of Technology, Gardens Point Campus, Brisbane, Queensland, Australia
7 shared publications- Peter Pivonka
School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD, Australia
7 shared publications - François Bruyer-Montéléone
School of Mech., Medical & Process Eng, Queensland University of Technology, Brisbane, Australia
6 shared publications Ashish Gupta
School of Mechanical, Medical & Process Engineering, Faculty of Engineering Queensland University of Technology Brisbane Queensland Australia
5 shared publications- Graham Kerr
Faculty of Health, Queensland University of Technology
5 shared publications Saulo Martelli
School of Mechanical, Medical and Process Engineering Queensland University of Technology Brisbane Queensland Australia
5 shared publications
Latest Publications
- Open Access
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
How many musculoskeletal models are enough? Sample-size requirements for glenohumeral joint-force distributions, from mean to tail
Musculoskeletal models non-invasively estimate internal variables such as glenohumeral joint (GHJ) forces. Yet, cohorts that reproduce average behavior may still miss rare anatomical and biomechanical combinations in the distribution’s tails. These uncommon profiles may be scientifically or clinically relevant, particularly when adverse outcomes arise in only a minority of individuals. This study quantified the sensitivity of central and peripheral GHJ force descriptors to sample size and determined the point of stability (POS), defined as the minimum sample size required to approximate a large reference population. The reference population, consisting of 500 anatomically diverse shoulder models generated from a statistical shape model of the humerus, scapula and clavicle, was used to simulate unloaded abduction and flexion to 90° elevation. For different sample sizes, 1,000 random subsamples were generated, and their means, medians, quartiles, selected percentiles and distributional limits were compared with those of the full cohort. Convergence was assessed using a tolerance of 0.5 times the full-cohort standard deviation. Central descriptors were substantially less sensitive to sample size than peripheral descriptors. At 90° elevation, 80% of subsamples reached stability with 9 models for the mean, 11–13 for the median, 24–25 for the 75th percentile, 36–47 for the 85th percentile and 63–71 for the lower distributional limit; more than 100 models were required for the upper limit. Requirements were similar across motions and elevation angles. Thus, 10–15 models may adequately represent average GHJ force responses, whereas increasingly peripheral responses require substantially larger or deliberately targeted samples.
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHow many musculoskeletal models are enough? Sample-size requirements for glenohumeral joint-force distributions, from mean to tail
Musculoskeletal models non-invasively estimate internal variables such as glenohumeral joint (GHJ) forces. Yet, cohorts that reproduce average behavior may still miss rare anatomical and biomechanical combinations in the distribution’s tails. These uncommon profiles may be scientifically or clinically relevant, particularly when adverse outcomes arise in only a minority of individuals. This study quantified the sensitivity of central and peripheral GHJ force descriptors to sample size and determined the point of stability (POS), defined as the minimum sample size required to approximate a large reference population. The reference population, consisting of 500 anatomically diverse shoulder models generated from a statistical shape model of the humerus, scapula and clavicle, was used to simulate unloaded abduction and flexion to 90° elevation. For different sample sizes, 1,000 random subsamples were generated, and their means, medians, quartiles, selected percentiles and distributional limits were compared with those of the full cohort. Convergence was assessed using a tolerance of 0.5 times the full-cohort standard deviation. Central descriptors were substantially less sensitive to sample size than peripheral descriptors. At 90° elevation, 80% of subsamples reached stability with 9 models for the mean, 11–13 for the median, 24–25 for the 75th percentile, 36–47 for the 85th percentile and 63–71 for the lower distributional limit; more than 100 models were required for the upper limit. Requirements were similar across motions and elevation angles. Thus, 10–15 models may adequately represent average GHJ force responses, whereas increasingly peripheral responses require substantially larger or deliberately targeted samples.
- Open Access
- 14 July 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113473
Investigating glenohumeral joint forces using a population-based musculoskeletal model combined with a shoulder statistical shape approach
- 14 July 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113473
Open AccessInvestigating glenohumeral joint forces using a population-based musculoskeletal model combined with a shoulder statistical shape approach
- Open Access
- 9 June 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (6) , e0347231
Comprehensive reconstruction of the musculoskeletal anatomy in the shoulder using a hybrid 3D ultrasound mosaicking workflow: A pilot study
Background: Three-dimensional (3D) ultrasound (US) imaging of complex joints such as the shoulder is limited by a small field of view and shallow imaging depth. As a result, capturing the entire shoulder anatomy in a single scan is not feasible. This study evaluates a hybrid 3D US mosaicking workflow that combines probe pose tracking, image-based alignment, and magnetic resonance imaging (MRI) guidance to reconstruct the full shoulder musculoskeletal anatomy. Methods: Five healthy volunteers underwent shoulder imaging using a robot-assisted 3D US probe. Each shoulder was divided into five scan regions, yielding approximately 45 partially overlapping US volumes per trial. Volumes were first positioned using probe pose information and then refined using a hybrid alignment strategy that combined semi-automatic US-US registration with expert manual adjustments guided by subject-specific MRI bone models. Reconstruction performance was assessed by measuring alignment consistency of the humerus across overlapping volumes using Dice similarity coefficients and multimodal overlap metrics. Results: The hybrid workflow improved reconstruction accuracy by approximately 17% compared to pose estimation alone. The refined reconstructions showed clearer anatomical continuity and fewer alignment artefacts. Reconstruction accuracy was influenced by the amount of overlap between scans and by differences in shoulder position between US and MRI acquisitions. Weighted mean compounding performed best for regional reconstructions with sufficient overlap, while maximum compounding was more effective for whole-shoulder mosaics. Conclusion: This study demonstrates the feasibility of reconstructing the full shoulder anatomy using a hybrid 3D US mosaicking approach. The proposed workflow improves alignment accuracy and anatomical visualisation compared with pose estimation alone and provides a practical reference framework for future large-scale and automated, real-time musculoskeletal US reconstruction.
- 9 June 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (6) , e0347231
Open AccessComprehensive reconstruction of the musculoskeletal anatomy in the shoulder using a hybrid 3D ultrasound mosaicking workflow: A pilot study
Background: Three-dimensional (3D) ultrasound (US) imaging of complex joints such as the shoulder is limited by a small field of view and shallow imaging depth. As a result, capturing the entire shoulder anatomy in a single scan is not feasible. This study evaluates a hybrid 3D US mosaicking workflow that combines probe pose tracking, image-based alignment, and magnetic resonance imaging (MRI) guidance to reconstruct the full shoulder musculoskeletal anatomy. Methods: Five healthy volunteers underwent shoulder imaging using a robot-assisted 3D US probe. Each shoulder was divided into five scan regions, yielding approximately 45 partially overlapping US volumes per trial. Volumes were first positioned using probe pose information and then refined using a hybrid alignment strategy that combined semi-automatic US-US registration with expert manual adjustments guided by subject-specific MRI bone models. Reconstruction performance was assessed by measuring alignment consistency of the humerus across overlapping volumes using Dice similarity coefficients and multimodal overlap metrics. Results: The hybrid workflow improved reconstruction accuracy by approximately 17% compared to pose estimation alone. The refined reconstructions showed clearer anatomical continuity and fewer alignment artefacts. Reconstruction accuracy was influenced by the amount of overlap between scans and by differences in shoulder position between US and MRI acquisitions. Weighted mean compounding performed best for regional reconstructions with sufficient overlap, while maximum compounding was more effective for whole-shoulder mosaics. Conclusion: This study demonstrates the feasibility of reconstructing the full shoulder anatomy using a hybrid 3D US mosaicking approach. The proposed workflow improves alignment accuracy and anatomical visualisation compared with pose estimation alone and provides a practical reference framework for future large-scale and automated, real-time musculoskeletal US reconstruction.
- Open Access
- 30 May 2026
- Published by Elsevier in SSRN Electronic Journal
Bi-Fluoroscopy-Informed Machine Learning Reduces Skin-Marker-Based Scapular Soft-Tissue Artifacts And 3D Kinematic Errors
Background: Accurate quantification of scapular motion is essential to understanding shoulder biomechanics, yet remains challenging due to soft-tissue artefacts (STA) affecting skin-marker-based motion capture. This study aimed to quantify scapular STA and develop a machine learning (ML) framework to improve skin-marker-based scapula tracking errors using ground-truth bi-fluoroscopy (BF) data. Methods: Concurrent BF and videogrammetry data from 20 healthy participants performing static and dynamic upper-limb tasks were leveraged. Ten upper-limb skin markers and four scapular landmarks were tracked, yielding 101,936 frames of synchronised motion data. Twelve ML regression models were trained to predict BF-informed scapular landmark trajectories from demographic, motion-specific, and spatiotemporal marker inputs. Model performance was evaluated on unseen participants, and predicted trajectories were compared with BF measurements. Results: Results showed that raw skin-marker scapular errors reached up to 120 mm and 14°, depending on the motion type, while the ML correction reduced landmark root-mean-square errors (RMSE) on average by 49% and up to 73% (Angulus Inferior in antero-posterior), and rotational RMSE by up to 49% (scapular upward rotation). Significance: The proposed BF-informed ML framework substantially improves the accuracy of scapula tracking without requiring invasive techniques or ionising radiation, providing a promising approach for reliable, non-invasive shoulder motion analysis in research and clinical applications.
- 30 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBi-Fluoroscopy-Informed Machine Learning Reduces Skin-Marker-Based Scapular Soft-Tissue Artifacts And 3D Kinematic Errors
Background: Accurate quantification of scapular motion is essential to understanding shoulder biomechanics, yet remains challenging due to soft-tissue artefacts (STA) affecting skin-marker-based motion capture. This study aimed to quantify scapular STA and develop a machine learning (ML) framework to improve skin-marker-based scapula tracking errors using ground-truth bi-fluoroscopy (BF) data. Methods: Concurrent BF and videogrammetry data from 20 healthy participants performing static and dynamic upper-limb tasks were leveraged. Ten upper-limb skin markers and four scapular landmarks were tracked, yielding 101,936 frames of synchronised motion data. Twelve ML regression models were trained to predict BF-informed scapular landmark trajectories from demographic, motion-specific, and spatiotemporal marker inputs. Model performance was evaluated on unseen participants, and predicted trajectories were compared with BF measurements. Results: Results showed that raw skin-marker scapular errors reached up to 120 mm and 14°, depending on the motion type, while the ML correction reduced landmark root-mean-square errors (RMSE) on average by 49% and up to 73% (Angulus Inferior in antero-posterior), and rotational RMSE by up to 49% (scapular upward rotation). Significance: The proposed BF-informed ML framework substantially improves the accuracy of scapula tracking without requiring invasive techniques or ionising radiation, providing a promising approach for reliable, non-invasive shoulder motion analysis in research and clinical applications.
- Open Access
- 26 April 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (5) , e70209
Accurate Humeral Version Angle Prediction From Limited Anatomical Data Using Statistical Shape Models
Shoulder replacement is challenged by the need to approximate the patient's pre‐morbid humeral version angle (HVA) with limited information. Statistical Shape Models (SSMs) can reconstruct bone shapes and predict HVA by identifying the best global shape match. However, SSMs require visible humeral anatomy, and optimal global reconstruction does not necessarily ensure accurate HVA. Multisegmented SSMs (MSSMs) combine adjacent bones to leverage inter‐bone shape correlations, but their potential remains largely unexplored. This project uses scale‐free humeral SSM and three‐shoulder‐bone MSSM to estimate HVA from clinically available surfaces and examine how HVA accuracy relates to global and local bone reconstruction. Sixty‐one registered bones were segmented (29 males and 32 females, 36.1 ± 14.3 years) from medical images. A leave‐one‐out method tested the models' ability to reconstruct the humerus and HVA under surgical scenarios: the SSM for cases with visible humeral parts (distal‐ or proximal‐limited), and the MSSM for cases with no humeral information (solely on adjoining segments). SSM‐based cases produced higher HVA accuracy than MSSM scenarios (max error: 3.3° ± 2.3° vs. 6.6° ± 5.4°). In both models, errors were driven primarily by marker‐level discrepancies rather than global shape error. These results highlight that, when predicting anatomical measurements, SSM predictions should prioritize anatomical accuracy over achieving the best‐fitting global shape.
- 26 April 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (5) , e70209
Open AccessAccurate Humeral Version Angle Prediction From Limited Anatomical Data Using Statistical Shape Models
Shoulder replacement is challenged by the need to approximate the patient's pre‐morbid humeral version angle (HVA) with limited information. Statistical Shape Models (SSMs) can reconstruct bone shapes and predict HVA by identifying the best global shape match. However, SSMs require visible humeral anatomy, and optimal global reconstruction does not necessarily ensure accurate HVA. Multisegmented SSMs (MSSMs) combine adjacent bones to leverage inter‐bone shape correlations, but their potential remains largely unexplored. This project uses scale‐free humeral SSM and three‐shoulder‐bone MSSM to estimate HVA from clinically available surfaces and examine how HVA accuracy relates to global and local bone reconstruction. Sixty‐one registered bones were segmented (29 males and 32 females, 36.1 ± 14.3 years) from medical images. A leave‐one‐out method tested the models' ability to reconstruct the humerus and HVA under surgical scenarios: the SSM for cases with visible humeral parts (distal‐ or proximal‐limited), and the MSSM for cases with no humeral information (solely on adjoining segments). SSM‐based cases produced higher HVA accuracy than MSSM scenarios (max error: 3.3° ± 2.3° vs. 6.6° ± 5.4°). In both models, errors were driven primarily by marker‐level discrepancies rather than global shape error. These results highlight that, when predicting anatomical measurements, SSM predictions should prioritize anatomical accuracy over achieving the best‐fitting global shape.
- 19 December 2025
- Published by Wiley in Journal of Anatomy
- Vol. 249 (2) , 359-370
Anatomy of a pose: Relationships between human shoulder bone shape and pose
Shoulder anatomy is complex, varying in shape and pose. Studies have related bone shape and joint function, which can predict each other but not yet in the shoulder. This project aims to investigate bone shape and pose relationships in the healthy shoulder via partial least square regressions (PLSR). Sixty‐eight registered humeri, scapulae, and clavicles were segmented (47 males and 15 females, age: 30.7 ± 9.5 years) from medical images (computed tomography and magnetic resonance images) and constituted the shape input (principal component analysis scores). Local bone coordinate systems (three axes and origin) composed the pose information. PLSR analyses were conducted using the shape of one or all three bones to predict the pose and vice versa. The main variation mode explained scaling for shape (38% variation explained) and the three shoulder bones' anteroposterior (AP) and superoinferior translations, and humeral and clavicular AP rotations for pose (8%). There was no difference in explained pose variation whether using the humerus, scapula, or clavicle as predictors. However, pose variations were more intertwined between the scapula and the clavicle when using all three shoulder bones as predictors compared to single‐bone models, suggesting a stronger coupling between these bones that likely originates from their shared anatomical constraints with the thoracic cage. The dataset showed a mild to excellent fit to the analysis ( R 2 = 0.4–0.9); however, the findings lacked generalizability ( Q 2 = 0.0–0.1), suggesting that PLSRs require additional information—such as soft tissue contributions—to enhance predictive performance. These findings have potential clinical applications in surgical planning, where individual bone shape could be used to estimate native shoulder poses in trauma patients; however, stronger predictive models incorporating additional anatomical or biomechanical parameters are needed to support such use.
- 19 December 2025
- Published by Wiley in Journal of Anatomy
- Vol. 249 (2) , 359-370
Anatomy of a pose: Relationships between human shoulder bone shape and pose
Shoulder anatomy is complex, varying in shape and pose. Studies have related bone shape and joint function, which can predict each other but not yet in the shoulder. This project aims to investigate bone shape and pose relationships in the healthy shoulder via partial least square regressions (PLSR). Sixty‐eight registered humeri, scapulae, and clavicles were segmented (47 males and 15 females, age: 30.7 ± 9.5 years) from medical images (computed tomography and magnetic resonance images) and constituted the shape input (principal component analysis scores). Local bone coordinate systems (three axes and origin) composed the pose information. PLSR analyses were conducted using the shape of one or all three bones to predict the pose and vice versa. The main variation mode explained scaling for shape (38% variation explained) and the three shoulder bones' anteroposterior (AP) and superoinferior translations, and humeral and clavicular AP rotations for pose (8%). There was no difference in explained pose variation whether using the humerus, scapula, or clavicle as predictors. However, pose variations were more intertwined between the scapula and the clavicle when using all three shoulder bones as predictors compared to single‐bone models, suggesting a stronger coupling between these bones that likely originates from their shared anatomical constraints with the thoracic cage. The dataset showed a mild to excellent fit to the analysis ( R 2 = 0.4–0.9); however, the findings lacked generalizability ( Q 2 = 0.0–0.1), suggesting that PLSRs require additional information—such as soft tissue contributions—to enhance predictive performance. These findings have potential clinical applications in surgical planning, where individual bone shape could be used to estimate native shoulder poses in trauma patients; however, stronger predictive models incorporating additional anatomical or biomechanical parameters are needed to support such use.
- Open Access
- 1 October 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 193, 112993
Stochastic modelling of muscle control during shoulder abduction
- 1 October 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 193, 112993
Open AccessStochastic modelling of muscle control during shoulder abduction
- Open Access
- 7 August 2025
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 18 (4) , 725-740
Comparison of 2D-pose with 3D motion capture methods for assessment of active shoulder range of motion
Background: Smartphone-based 2D-pose estimation offers a convenient method for assessing shoulder range-of-motion (ROM), but its accuracy compared to 3D motion capture (3D-mocap) needs to be determined. Methods: Shoulder ROM was recorded in seventeen participants without shoulder issues using 3D-mocap and 2D-pose concurrently. Movements included abduction, flexion, extension, external, and functional internal rotation (IR). 2D-pose ROM estimates (mymobility's ® Skeletal Tracking Shoulder Range of Motion Assessments feature (Apple Vision framework, Apple Inc., Cupertino, CA, USA) were compared to 3D-mocap using linear mixed-models and Bland-Altman analysis. The influence of thoracic compensation and anatomical frame definitions on shoulder ROM estimates was examined. Results: High consistency was observed between 2D-pose and 3D-mocap ( R 2 > 0.98), especially for abduction and flexion. Differences in ROM were linked to anatomical frame variations and thoracic contributions, with 2D-pose overestimating ROM at greater ranges (2°–25°). Internal rotation zone identification showed high consistency, but 2D-pose-based extension and external rotation showed more variability due to thoracic compensation. Conclusions: Smartphone-based 2D-pose estimation provides a valid alternative for shoulder ROM measurement but should not be used interchangeably with 3D-mocap due to discrepancies arising from anatomical frame definitions and thoracic movements. Shoulder ROM assessment requires consideration of these limitations to ensure appropriate clinical interpretation.
- 7 August 2025
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 18 (4) , 725-740
Open AccessComparison of 2D-pose with 3D motion capture methods for assessment of active shoulder range of motion
Background: Smartphone-based 2D-pose estimation offers a convenient method for assessing shoulder range-of-motion (ROM), but its accuracy compared to 3D motion capture (3D-mocap) needs to be determined. Methods: Shoulder ROM was recorded in seventeen participants without shoulder issues using 3D-mocap and 2D-pose concurrently. Movements included abduction, flexion, extension, external, and functional internal rotation (IR). 2D-pose ROM estimates (mymobility's ® Skeletal Tracking Shoulder Range of Motion Assessments feature (Apple Vision framework, Apple Inc., Cupertino, CA, USA) were compared to 3D-mocap using linear mixed-models and Bland-Altman analysis. The influence of thoracic compensation and anatomical frame definitions on shoulder ROM estimates was examined. Results: High consistency was observed between 2D-pose and 3D-mocap ( R 2 > 0.98), especially for abduction and flexion. Differences in ROM were linked to anatomical frame variations and thoracic contributions, with 2D-pose overestimating ROM at greater ranges (2°–25°). Internal rotation zone identification showed high consistency, but 2D-pose-based extension and external rotation showed more variability due to thoracic compensation. Conclusions: Smartphone-based 2D-pose estimation provides a valid alternative for shoulder ROM measurement but should not be used interchangeably with 3D-mocap due to discrepancies arising from anatomical frame definitions and thoracic movements. Shoulder ROM assessment requires consideration of these limitations to ensure appropriate clinical interpretation.
- Open Access
- 10 June 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1793-1802
How do visual and smartphone camera-based shoulder ranges of motion compare?
- 10 June 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1793-1802
Open AccessHow do visual and smartphone camera-based shoulder ranges of motion compare?
- Open Access
- 6 February 2025
- Published by Springer Nature in Multibody System Dynamics
- Vol. 65 (4) , 621-643
Muscle path predictions using a discrete geodesic Euler–Lagrange model in constrained optimisation: comparison with OpenSim and experimental data
Accurate and robust modelling of muscle paths is crucial for predicting human movement. Traditional methods often rely on simplified straight-line representations and manual specifications of via-points and wrapping surfaces, which may lead to inconsistent and unrealistic muscle paths The discrete geodesic Euler–Lagrange (DGEL) method identifies geodesics with minimal curvature trajectories that adhere closely to anatomical constraints. Embedding DGEL into an optimisation problem with a specific objective function has the potential to identify muscle paths with smooth changes in muscle length over the course of the motion, thereby avoiding abrupt muscle discontinuities. This study aims to investigate the performance of the DGEL method. We developed multibody models with increasing complexity (i.e. a static arm model, a kinematic elbow model and a kinematic shoulder model) and investigated different scenarios, such as muscle attachment modifications, simulation of diverse motions and extreme ranges of motion. We performed a comparative analysis between the geodesic model and the open-source OpenSim framework, with validation against experimental data to assess physiological plausibility. Our findings reveal that the DGEL method overcomes limitations inherent in traditional approaches, including discontinuities and incorrect wrapping surface interactions. For the static arm model, the DGEL-computed muscle length showed a closer match to ground truth compared to OpenSim. In the elbow model, the DGEL method eliminated unphysiological muscle path discontinuities. In the shoulder model, the DGEL method was validated across three different motions against experimental muscle moment arms, achieving great accuracy and superior robustness in handling complex muscle paths. This method effectively addressed common pitfalls in muscle path modelling, such as bone penetrations and erratic trajectories. Future work will further validate the DGEL method across diverse real-world applications and optimise its performance through advanced objective functions. The DGEL approach represents a significant improvement in the accuracy and robustness of muscle path modelling, advancing the field of biomechanics and musculoskeletal modelling.
- 6 February 2025
- Published by Springer Nature in Multibody System Dynamics
- Vol. 65 (4) , 621-643
Open AccessMuscle path predictions using a discrete geodesic Euler–Lagrange model in constrained optimisation: comparison with OpenSim and experimental data
Accurate and robust modelling of muscle paths is crucial for predicting human movement. Traditional methods often rely on simplified straight-line representations and manual specifications of via-points and wrapping surfaces, which may lead to inconsistent and unrealistic muscle paths The discrete geodesic Euler–Lagrange (DGEL) method identifies geodesics with minimal curvature trajectories that adhere closely to anatomical constraints. Embedding DGEL into an optimisation problem with a specific objective function has the potential to identify muscle paths with smooth changes in muscle length over the course of the motion, thereby avoiding abrupt muscle discontinuities. This study aims to investigate the performance of the DGEL method. We developed multibody models with increasing complexity (i.e. a static arm model, a kinematic elbow model and a kinematic shoulder model) and investigated different scenarios, such as muscle attachment modifications, simulation of diverse motions and extreme ranges of motion. We performed a comparative analysis between the geodesic model and the open-source OpenSim framework, with validation against experimental data to assess physiological plausibility. Our findings reveal that the DGEL method overcomes limitations inherent in traditional approaches, including discontinuities and incorrect wrapping surface interactions. For the static arm model, the DGEL-computed muscle length showed a closer match to ground truth compared to OpenSim. In the elbow model, the DGEL method eliminated unphysiological muscle path discontinuities. In the shoulder model, the DGEL method was validated across three different motions against experimental muscle moment arms, achieving great accuracy and superior robustness in handling complex muscle paths. This method effectively addressed common pitfalls in muscle path modelling, such as bone penetrations and erratic trajectories. Future work will further validate the DGEL method across diverse real-world applications and optimise its performance through advanced objective functions. The DGEL approach represents a significant improvement in the accuracy and robustness of muscle path modelling, advancing the field of biomechanics and musculoskeletal modelling.