François Bruyer-Montéléone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
François Bruyer-Montéléone has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Maxence Lavaill
School of Mech., Medical & Process Eng, Queensland University of Technology, Brisbane, Australia
6 shared publications Ashish Gupta
School of Mechanical, Medical & Process Engineering, Faculty of Engineering Queensland University of Technology Brisbane Queensland Australia
3 shared publicationsGraham Kerr
School of Mechanical, Medical and Process Engineering Queensland University of Technology Brisbane Queensland Australia
3 shared publications- Graham Kerr
Faculty of Health, Queensland University of Technology
3 shared publications - Jeffrey E. Bischoff
Zimmer Biomet Warsaw Indiana USA
3 shared publications Freek Hollman
Queensland Unit for Advanced Shoulder Research, Brisbane, QLD, Australia
2 shared publications
Latest Publications
- Open Access
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
How many musculoskeletal models are enough? Sample-size requirements for glenohumeral joint-force distributions, from mean to tail
Musculoskeletal models non-invasively estimate internal variables such as glenohumeral joint (GHJ) forces. Yet, cohorts that reproduce average behavior may still miss rare anatomical and biomechanical combinations in the distribution’s tails. These uncommon profiles may be scientifically or clinically relevant, particularly when adverse outcomes arise in only a minority of individuals. This study quantified the sensitivity of central and peripheral GHJ force descriptors to sample size and determined the point of stability (POS), defined as the minimum sample size required to approximate a large reference population. The reference population, consisting of 500 anatomically diverse shoulder models generated from a statistical shape model of the humerus, scapula and clavicle, was used to simulate unloaded abduction and flexion to 90° elevation. For different sample sizes, 1,000 random subsamples were generated, and their means, medians, quartiles, selected percentiles and distributional limits were compared with those of the full cohort. Convergence was assessed using a tolerance of 0.5 times the full-cohort standard deviation. Central descriptors were substantially less sensitive to sample size than peripheral descriptors. At 90° elevation, 80% of subsamples reached stability with 9 models for the mean, 11–13 for the median, 24–25 for the 75th percentile, 36–47 for the 85th percentile and 63–71 for the lower distributional limit; more than 100 models were required for the upper limit. Requirements were similar across motions and elevation angles. Thus, 10–15 models may adequately represent average GHJ force responses, whereas increasingly peripheral responses require substantially larger or deliberately targeted samples.
- 2 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHow many musculoskeletal models are enough? Sample-size requirements for glenohumeral joint-force distributions, from mean to tail
Musculoskeletal models non-invasively estimate internal variables such as glenohumeral joint (GHJ) forces. Yet, cohorts that reproduce average behavior may still miss rare anatomical and biomechanical combinations in the distribution’s tails. These uncommon profiles may be scientifically or clinically relevant, particularly when adverse outcomes arise in only a minority of individuals. This study quantified the sensitivity of central and peripheral GHJ force descriptors to sample size and determined the point of stability (POS), defined as the minimum sample size required to approximate a large reference population. The reference population, consisting of 500 anatomically diverse shoulder models generated from a statistical shape model of the humerus, scapula and clavicle, was used to simulate unloaded abduction and flexion to 90° elevation. For different sample sizes, 1,000 random subsamples were generated, and their means, medians, quartiles, selected percentiles and distributional limits were compared with those of the full cohort. Convergence was assessed using a tolerance of 0.5 times the full-cohort standard deviation. Central descriptors were substantially less sensitive to sample size than peripheral descriptors. At 90° elevation, 80% of subsamples reached stability with 9 models for the mean, 11–13 for the median, 24–25 for the 75th percentile, 36–47 for the 85th percentile and 63–71 for the lower distributional limit; more than 100 models were required for the upper limit. Requirements were similar across motions and elevation angles. Thus, 10–15 models may adequately represent average GHJ force responses, whereas increasingly peripheral responses require substantially larger or deliberately targeted samples.
- Open Access
- 14 July 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113473
Investigating glenohumeral joint forces using a population-based musculoskeletal model combined with a shoulder statistical shape approach
- 14 July 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113473
Open AccessInvestigating glenohumeral joint forces using a population-based musculoskeletal model combined with a shoulder statistical shape approach
- Open Access
- 26 April 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (5) , e70209
Accurate Humeral Version Angle Prediction From Limited Anatomical Data Using Statistical Shape Models
Shoulder replacement is challenged by the need to approximate the patient's pre‐morbid humeral version angle (HVA) with limited information. Statistical Shape Models (SSMs) can reconstruct bone shapes and predict HVA by identifying the best global shape match. However, SSMs require visible humeral anatomy, and optimal global reconstruction does not necessarily ensure accurate HVA. Multisegmented SSMs (MSSMs) combine adjacent bones to leverage inter‐bone shape correlations, but their potential remains largely unexplored. This project uses scale‐free humeral SSM and three‐shoulder‐bone MSSM to estimate HVA from clinically available surfaces and examine how HVA accuracy relates to global and local bone reconstruction. Sixty‐one registered bones were segmented (29 males and 32 females, 36.1 ± 14.3 years) from medical images. A leave‐one‐out method tested the models' ability to reconstruct the humerus and HVA under surgical scenarios: the SSM for cases with visible humeral parts (distal‐ or proximal‐limited), and the MSSM for cases with no humeral information (solely on adjoining segments). SSM‐based cases produced higher HVA accuracy than MSSM scenarios (max error: 3.3° ± 2.3° vs. 6.6° ± 5.4°). In both models, errors were driven primarily by marker‐level discrepancies rather than global shape error. These results highlight that, when predicting anatomical measurements, SSM predictions should prioritize anatomical accuracy over achieving the best‐fitting global shape.
- 26 April 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (5) , e70209
Open AccessAccurate Humeral Version Angle Prediction From Limited Anatomical Data Using Statistical Shape Models
Shoulder replacement is challenged by the need to approximate the patient's pre‐morbid humeral version angle (HVA) with limited information. Statistical Shape Models (SSMs) can reconstruct bone shapes and predict HVA by identifying the best global shape match. However, SSMs require visible humeral anatomy, and optimal global reconstruction does not necessarily ensure accurate HVA. Multisegmented SSMs (MSSMs) combine adjacent bones to leverage inter‐bone shape correlations, but their potential remains largely unexplored. This project uses scale‐free humeral SSM and three‐shoulder‐bone MSSM to estimate HVA from clinically available surfaces and examine how HVA accuracy relates to global and local bone reconstruction. Sixty‐one registered bones were segmented (29 males and 32 females, 36.1 ± 14.3 years) from medical images. A leave‐one‐out method tested the models' ability to reconstruct the humerus and HVA under surgical scenarios: the SSM for cases with visible humeral parts (distal‐ or proximal‐limited), and the MSSM for cases with no humeral information (solely on adjoining segments). SSM‐based cases produced higher HVA accuracy than MSSM scenarios (max error: 3.3° ± 2.3° vs. 6.6° ± 5.4°). In both models, errors were driven primarily by marker‐level discrepancies rather than global shape error. These results highlight that, when predicting anatomical measurements, SSM predictions should prioritize anatomical accuracy over achieving the best‐fitting global shape.
- 19 December 2025
- Published by Wiley in Journal of Anatomy
- Vol. 249 (2) , 359-370
Anatomy of a pose: Relationships between human shoulder bone shape and pose
Shoulder anatomy is complex, varying in shape and pose. Studies have related bone shape and joint function, which can predict each other but not yet in the shoulder. This project aims to investigate bone shape and pose relationships in the healthy shoulder via partial least square regressions (PLSR). Sixty‐eight registered humeri, scapulae, and clavicles were segmented (47 males and 15 females, age: 30.7 ± 9.5 years) from medical images (computed tomography and magnetic resonance images) and constituted the shape input (principal component analysis scores). Local bone coordinate systems (three axes and origin) composed the pose information. PLSR analyses were conducted using the shape of one or all three bones to predict the pose and vice versa. The main variation mode explained scaling for shape (38% variation explained) and the three shoulder bones' anteroposterior (AP) and superoinferior translations, and humeral and clavicular AP rotations for pose (8%). There was no difference in explained pose variation whether using the humerus, scapula, or clavicle as predictors. However, pose variations were more intertwined between the scapula and the clavicle when using all three shoulder bones as predictors compared to single‐bone models, suggesting a stronger coupling between these bones that likely originates from their shared anatomical constraints with the thoracic cage. The dataset showed a mild to excellent fit to the analysis ( R 2 = 0.4–0.9); however, the findings lacked generalizability ( Q 2 = 0.0–0.1), suggesting that PLSRs require additional information—such as soft tissue contributions—to enhance predictive performance. These findings have potential clinical applications in surgical planning, where individual bone shape could be used to estimate native shoulder poses in trauma patients; however, stronger predictive models incorporating additional anatomical or biomechanical parameters are needed to support such use.
- 19 December 2025
- Published by Wiley in Journal of Anatomy
- Vol. 249 (2) , 359-370
Anatomy of a pose: Relationships between human shoulder bone shape and pose
Shoulder anatomy is complex, varying in shape and pose. Studies have related bone shape and joint function, which can predict each other but not yet in the shoulder. This project aims to investigate bone shape and pose relationships in the healthy shoulder via partial least square regressions (PLSR). Sixty‐eight registered humeri, scapulae, and clavicles were segmented (47 males and 15 females, age: 30.7 ± 9.5 years) from medical images (computed tomography and magnetic resonance images) and constituted the shape input (principal component analysis scores). Local bone coordinate systems (three axes and origin) composed the pose information. PLSR analyses were conducted using the shape of one or all three bones to predict the pose and vice versa. The main variation mode explained scaling for shape (38% variation explained) and the three shoulder bones' anteroposterior (AP) and superoinferior translations, and humeral and clavicular AP rotations for pose (8%). There was no difference in explained pose variation whether using the humerus, scapula, or clavicle as predictors. However, pose variations were more intertwined between the scapula and the clavicle when using all three shoulder bones as predictors compared to single‐bone models, suggesting a stronger coupling between these bones that likely originates from their shared anatomical constraints with the thoracic cage. The dataset showed a mild to excellent fit to the analysis ( R 2 = 0.4–0.9); however, the findings lacked generalizability ( Q 2 = 0.0–0.1), suggesting that PLSRs require additional information—such as soft tissue contributions—to enhance predictive performance. These findings have potential clinical applications in surgical planning, where individual bone shape could be used to estimate native shoulder poses in trauma patients; however, stronger predictive models incorporating additional anatomical or biomechanical parameters are needed to support such use.
- Open Access
- 7 August 2025
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 18 (4) , 725-740
Comparison of 2D-pose with 3D motion capture methods for assessment of active shoulder range of motion
Background: Smartphone-based 2D-pose estimation offers a convenient method for assessing shoulder range-of-motion (ROM), but its accuracy compared to 3D motion capture (3D-mocap) needs to be determined. Methods: Shoulder ROM was recorded in seventeen participants without shoulder issues using 3D-mocap and 2D-pose concurrently. Movements included abduction, flexion, extension, external, and functional internal rotation (IR). 2D-pose ROM estimates (mymobility's ® Skeletal Tracking Shoulder Range of Motion Assessments feature (Apple Vision framework, Apple Inc., Cupertino, CA, USA) were compared to 3D-mocap using linear mixed-models and Bland-Altman analysis. The influence of thoracic compensation and anatomical frame definitions on shoulder ROM estimates was examined. Results: High consistency was observed between 2D-pose and 3D-mocap ( R 2 > 0.98), especially for abduction and flexion. Differences in ROM were linked to anatomical frame variations and thoracic contributions, with 2D-pose overestimating ROM at greater ranges (2°–25°). Internal rotation zone identification showed high consistency, but 2D-pose-based extension and external rotation showed more variability due to thoracic compensation. Conclusions: Smartphone-based 2D-pose estimation provides a valid alternative for shoulder ROM measurement but should not be used interchangeably with 3D-mocap due to discrepancies arising from anatomical frame definitions and thoracic movements. Shoulder ROM assessment requires consideration of these limitations to ensure appropriate clinical interpretation.
- 7 August 2025
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 18 (4) , 725-740
Open AccessComparison of 2D-pose with 3D motion capture methods for assessment of active shoulder range of motion
Background: Smartphone-based 2D-pose estimation offers a convenient method for assessing shoulder range-of-motion (ROM), but its accuracy compared to 3D motion capture (3D-mocap) needs to be determined. Methods: Shoulder ROM was recorded in seventeen participants without shoulder issues using 3D-mocap and 2D-pose concurrently. Movements included abduction, flexion, extension, external, and functional internal rotation (IR). 2D-pose ROM estimates (mymobility's ® Skeletal Tracking Shoulder Range of Motion Assessments feature (Apple Vision framework, Apple Inc., Cupertino, CA, USA) were compared to 3D-mocap using linear mixed-models and Bland-Altman analysis. The influence of thoracic compensation and anatomical frame definitions on shoulder ROM estimates was examined. Results: High consistency was observed between 2D-pose and 3D-mocap ( R 2 > 0.98), especially for abduction and flexion. Differences in ROM were linked to anatomical frame variations and thoracic contributions, with 2D-pose overestimating ROM at greater ranges (2°–25°). Internal rotation zone identification showed high consistency, but 2D-pose-based extension and external rotation showed more variability due to thoracic compensation. Conclusions: Smartphone-based 2D-pose estimation provides a valid alternative for shoulder ROM measurement but should not be used interchangeably with 3D-mocap due to discrepancies arising from anatomical frame definitions and thoracic movements. Shoulder ROM assessment requires consideration of these limitations to ensure appropriate clinical interpretation.
- Open Access
- 10 June 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1793-1802
How do visual and smartphone camera-based shoulder ranges of motion compare?
- 10 June 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1793-1802
Open AccessHow do visual and smartphone camera-based shoulder ranges of motion compare?