Meihua Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Meihua Fang has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Ming Zhang
6 shared publications- Zhiyong Wei
Nanjing University of Aeronautics and Astronautics
6 shared publications - Xinyi Cai
College of Astronautics, Nanjing University of Aeronautics and Astronautics, Nanjing, China
5 shared publications Yi Guo
College of Astronautics, Nanjing University of Aeronautics and Astronautics, Nanjing, China
5 shared publicationsYipan Guo
5 shared publications- Jiafeng Li
College of Astronautics, Nanjing University of Aeronautics and Astronautics, Nanjing, China
4 shared publications
Latest Publications
- 23 November 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 131
Protocol-aware reliability fusion for cross-subject multimodal emotion recognition
- 23 November 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 131
Protocol-aware reliability fusion for cross-subject multimodal emotion recognition
- 8 October 2026
- Published by Springer Nature in Science China Earth Sciences
- Vol. 69 (11) , 4140-4153
Modeling electron fluxes in Earth’s outer radiation belt using fused RBSP and Arase observations
- 8 October 2026
- Published by Springer Nature in Science China Earth Sciences
- Vol. 69 (11) , 4140-4153
Modeling electron fluxes in Earth’s outer radiation belt using fused RBSP and Arase observations
- Open Access
- 2 August 2026
- Published by Elsevier in SSRN Electronic Journal
Design and Performance Evaluation of a GAGG Long-Bar Compton Camera with Dual-Ended DOI Readout Using Geant4 Simulations
Compton cameras enable medium- and high-energy gamma-ray imaging without mechanical collimation. Extending an individual detector element increases the active volume without adding readout channels, but also increases axial position uncertainty and can degrade angular resolution. This study evaluated whether a GAGG long-bar Compton camera with dual-ended depth-of-interaction (DOI) readout could mitigate this trade-off. A Geant4 detector-response model reconstructed deposited energy and axial interaction position from the two end signals. Simulated reference-bar energy and DOI resolutions were comparable in magnitude to published measurements. The proposed design was compared with a conventional two-layer planar configuration at matched crystal cross section, transverse element count, and total readout-channel count. The effects of bar length and detector gap on valid two-crystal Compton-event efficiency and the angular resolution measure (ARM) were investigated. Increasing bar length and reducing detector gap improved efficiency, although the gain diminished above approximately 75 mm and a shorter geometric baseline broadened the ARM. For an on-axis 511-keV pencil beam and the adopted event-selection criteria, a 75-mm-bar, 10-mm-gap design achieved 0.836% valid-event efficiency and an ARM full width at half maximum (FWHM) of 11.42°. The conventional configuration with the closest ARM FWHM yielded 0.172% and 12.49°, respectively, making the DOI design approximately 4.9 times as efficient at a slightly lower ARM FWHM. These results indicate that dual-ended DOI GAGG bars can improve the detector-level balance between valid-event efficiency and ARM under a fixed readout-channel budget.
- 2 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesign and Performance Evaluation of a GAGG Long-Bar Compton Camera with Dual-Ended DOI Readout Using Geant4 Simulations
Compton cameras enable medium- and high-energy gamma-ray imaging without mechanical collimation. Extending an individual detector element increases the active volume without adding readout channels, but also increases axial position uncertainty and can degrade angular resolution. This study evaluated whether a GAGG long-bar Compton camera with dual-ended depth-of-interaction (DOI) readout could mitigate this trade-off. A Geant4 detector-response model reconstructed deposited energy and axial interaction position from the two end signals. Simulated reference-bar energy and DOI resolutions were comparable in magnitude to published measurements. The proposed design was compared with a conventional two-layer planar configuration at matched crystal cross section, transverse element count, and total readout-channel count. The effects of bar length and detector gap on valid two-crystal Compton-event efficiency and the angular resolution measure (ARM) were investigated. Increasing bar length and reducing detector gap improved efficiency, although the gain diminished above approximately 75 mm and a shorter geometric baseline broadened the ARM. For an on-axis 511-keV pencil beam and the adopted event-selection criteria, a 75-mm-bar, 10-mm-gap design achieved 0.836% valid-event efficiency and an ARM full width at half maximum (FWHM) of 11.42°. The conventional configuration with the closest ARM FWHM yielded 0.172% and 12.49°, respectively, making the DOI design approximately 4.9 times as efficient at a slightly lower ARM FWHM. These results indicate that dual-ended DOI GAGG bars can improve the detector-level balance between valid-event efficiency and ARM under a fixed readout-channel budget.
- 15 April 2026
- Published by Elsevier in Advances In Space Research
- Vol. 77 (12) , 12730-12740
Accelerated 3D sectoring analysis for spacecraft radiation shielding using octree culling and per-component kd-trees
- 15 April 2026
- Published by Elsevier in Advances In Space Research
- Vol. 77 (12) , 12730-12740
Accelerated 3D sectoring analysis for spacecraft radiation shielding using octree culling and per-component kd-trees
- 30 March 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 120
A multilevel EEG-EOG fusion framework for driver fatigue detection using evidential reasoning
- 30 March 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 120
A multilevel EEG-EOG fusion framework for driver fatigue detection using evidential reasoning
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (3) , 680-694
Design of a Dual-Scintillator Anti-Coincidence Detection System for Enhanced Energy Resolution and Background Suppression in Mixed-Field Low-Energy Gamma Spectroscopy
This work proposes a novel dual-scintillator anti-coincidence detection system consisting of a front-layer LYSO auxiliary scintillator and a rear 1”×1” LaBr3(Ce) main detector, designed for high-resolution low-energy gamma-ray spectroscopy in mixed-field environments by mitigating Compton scattering, charged particle interference, and intrinsic background. Geant4 simulations identified that a 3 mm-thick, 68 mm-diameter LYSO layer achieves the optimal overall system performance by suppressing 91.50% of charged-particle interference and improving the peak-to-Compton ratio (PCR) by 42.4% for 137Cs and by 45.6% under “137Cs + 90Sr” mixed-field conditions compared to the standalone LaBr3(Ce) detector. Experimental validation with multiple gamma sources (0.511-1.33 MeV) and mixed β-γ radiation fields confirmed the simulation results. With an optimized 130 ns anti-coincidence (AC) time window, the system exhibited improved spectral purity and reliable Gaussian fits, the energy resolution (ER) at 662keV improved to 3.26%, and further to 3.21% under mixed-field conditions. In the challenging “137Cs + 90Sr” environment, the anti-coincidence detection system enhanced the PCR to 2.0696 and the Peak-to-Total Ratio (PTR) to 0.4492, corresponding to a Peak-to-Compton Suppression Factor (PCSF) of 9.87 and a Peak-to-Total Suppression Factor (PTSF) of 19.79. Moreover, the intrinsic 176Lu activity in the LYSO crystal, typically a source of interference, was advantageously utilized for in-situ self-calibration, enabling accurate background subtraction and stable energy alignment, which ensured reliable PCR and PTR determination. The proposed LYSO-LaBr3(Ce) dual-scintillator anti-coincidence detection system achieves enhanced energy resolution and superior background suppression, offering a promising solution for high-precision gamma-ray measurements in complex mixed-field environments.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (3) , 680-694
Design of a Dual-Scintillator Anti-Coincidence Detection System for Enhanced Energy Resolution and Background Suppression in Mixed-Field Low-Energy Gamma Spectroscopy
This work proposes a novel dual-scintillator anti-coincidence detection system consisting of a front-layer LYSO auxiliary scintillator and a rear 1”×1” LaBr3(Ce) main detector, designed for high-resolution low-energy gamma-ray spectroscopy in mixed-field environments by mitigating Compton scattering, charged particle interference, and intrinsic background. Geant4 simulations identified that a 3 mm-thick, 68 mm-diameter LYSO layer achieves the optimal overall system performance by suppressing 91.50% of charged-particle interference and improving the peak-to-Compton ratio (PCR) by 42.4% for 137Cs and by 45.6% under “137Cs + 90Sr” mixed-field conditions compared to the standalone LaBr3(Ce) detector. Experimental validation with multiple gamma sources (0.511-1.33 MeV) and mixed β-γ radiation fields confirmed the simulation results. With an optimized 130 ns anti-coincidence (AC) time window, the system exhibited improved spectral purity and reliable Gaussian fits, the energy resolution (ER) at 662keV improved to 3.26%, and further to 3.21% under mixed-field conditions. In the challenging “137Cs + 90Sr” environment, the anti-coincidence detection system enhanced the PCR to 2.0696 and the Peak-to-Total Ratio (PTR) to 0.4492, corresponding to a Peak-to-Compton Suppression Factor (PCSF) of 9.87 and a Peak-to-Total Suppression Factor (PTSF) of 19.79. Moreover, the intrinsic 176Lu activity in the LYSO crystal, typically a source of interference, was advantageously utilized for in-situ self-calibration, enabling accurate background subtraction and stable energy alignment, which ensured reliable PCR and PTR determination. The proposed LYSO-LaBr3(Ce) dual-scintillator anti-coincidence detection system achieves enhanced energy resolution and superior background suppression, offering a promising solution for high-precision gamma-ray measurements in complex mixed-field environments.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11009
Pulse clipping recovery for enhanced low-energy PSD and extended dynamic range in PMT-Coupled plastic scintillator detectors
Plastic scintillator detectors are among the most widely used detectors in the field of radiation detection. To enhance the Pulse Shape Discrimination (PSD) performance of plastic scintillator detectors in the low-energy region, this study employs a high-gain readout approach by increasing the preamplifier gain in a scintillator system coupled with a Photomultiplier Tube (PMT). This method effectively improves the PSD capability for low-amplitude pulses by amplifying the signals to a level that far exceeds the digitizer's quantization noise. However, under high-gain conditions, large-amplitude pulses may exceed the dynamic range of the digitizer, resulting in pulse clipping, which significantly affects energy measurement range and high-energy PSD performance. To address this issue, a Pulse Clipping Recovery (PCR) method is proposed, based on reference pulse matching and minimization of the Root Mean Square Error (RMSE) in the tail region. By optimizing recovery coefficients, accurate reconstruction of clipped pulses is achieved. To validate the effectiveness of the PCR method, a dual-gain readout circuit was designed and implemented to simultaneously acquire high-gain and low-gain signals from the PMT anode and dynode, respectively. The accuracy of the recovery was subsequently evaluated by comparing the recovered high-gain pulses with the corresponding low-gain signals and the reference pulse. Experimental results show that in the 1–2 MeVee energy range, the high-gain channel achieves a Figure of Merit (FOM) of 0.92, significantly higher than the 0.30 obtained from the low-gain channel, highlighting the benefits of high-gain operation for low-energy PSD performance. The RMSE high between recovered and reference pulses on a point-by-point basis is as low as 0.0057, compared to 0.013 for low-gain signals, confirming the accuracy of the PCR method. Neutron-gamma discrimination based on the recovered pulses was further performed using both the Charge Comparison Method (CCM) and Frequency Gradient Analysis (FGA), yielding FOM values of 0.78 and 0.62, respectively, at a 0.5 MeVee threshold. These results demonstrate that the proposed method extends the effective energy range of the detector from 2 MeVee to 16 MeVee under high-gain conditions, enabling wide dynamic range measurements and significantly enhancing neutron-gamma discrimination capabilities.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11009
Pulse clipping recovery for enhanced low-energy PSD and extended dynamic range in PMT-Coupled plastic scintillator detectors
Plastic scintillator detectors are among the most widely used detectors in the field of radiation detection. To enhance the Pulse Shape Discrimination (PSD) performance of plastic scintillator detectors in the low-energy region, this study employs a high-gain readout approach by increasing the preamplifier gain in a scintillator system coupled with a Photomultiplier Tube (PMT). This method effectively improves the PSD capability for low-amplitude pulses by amplifying the signals to a level that far exceeds the digitizer's quantization noise. However, under high-gain conditions, large-amplitude pulses may exceed the dynamic range of the digitizer, resulting in pulse clipping, which significantly affects energy measurement range and high-energy PSD performance. To address this issue, a Pulse Clipping Recovery (PCR) method is proposed, based on reference pulse matching and minimization of the Root Mean Square Error (RMSE) in the tail region. By optimizing recovery coefficients, accurate reconstruction of clipped pulses is achieved. To validate the effectiveness of the PCR method, a dual-gain readout circuit was designed and implemented to simultaneously acquire high-gain and low-gain signals from the PMT anode and dynode, respectively. The accuracy of the recovery was subsequently evaluated by comparing the recovered high-gain pulses with the corresponding low-gain signals and the reference pulse. Experimental results show that in the 1–2 MeVee energy range, the high-gain channel achieves a Figure of Merit (FOM) of 0.92, significantly higher than the 0.30 obtained from the low-gain channel, highlighting the benefits of high-gain operation for low-energy PSD performance. The RMSE high between recovered and reference pulses on a point-by-point basis is as low as 0.0057, compared to 0.013 for low-gain signals, confirming the accuracy of the PCR method. Neutron-gamma discrimination based on the recovered pulses was further performed using both the Charge Comparison Method (CCM) and Frequency Gradient Analysis (FGA), yielding FOM values of 0.78 and 0.62, respectively, at a 0.5 MeVee threshold. These results demonstrate that the proposed method extends the effective energy range of the detector from 2 MeVee to 16 MeVee under high-gain conditions, enabling wide dynamic range measurements and significantly enhancing neutron-gamma discrimination capabilities.
- Open Access
- 18 September 2025
- Published by American Geophysical Union (AGU) in Space Weather
- Vol. 23 (9)
LSTM‐Based Modeling of Radiation Belt Electrons Using MagEIS Observations From RBSP Satellites
This study presents the development and validation of a Long Short‐Term Memory neural network model for predicting electron fluxes within the Earth's radiation belts, specifically covering an electron energy range from 33 to 2,619 keV, using data from the Magnetic Electron Ion Spectrometer onboard the Van Allen Probes (RBSP). By inputting a time series of historical solar wind conditions and geomagnetic indices, along with satellite location parameters and pitch angle, the model reproduces observed electron fluxes. A Spearman correlation analysis was performed to determine an optimal 300‐hr time series length, which accommodates the longer lag times associated with higher‐energy electrons. The model maintains an uncertainty factor within 2 across all energy ranges in the outer radiation belt and achieves its best performance at the 597 keV energy channel, with a prediction efficiency of 0.97 and a Root Mean Square Error of 0.166 log10(Flux). To further examine the model's robustness under complex geomagnetic conditions, we predicted electron fluxes during three distinct magnetic storm events. Even under these challenging conditions, the model consistently reproduced observed flux variations with high fidelity and relatively low errors. The discrepancies were primarily confined to the transition zones between high‐flux and low‐flux regions. In addition, we validated the model against an independent data set from the Arase satellite in 2018. At an energy of 1,064 keV, the predicted fluxes achieved a Pearson correlation coefficient of 0.831 with observations, demonstrating the model's strong generalization capability across different instruments and data sets.
- 18 September 2025
- Published by American Geophysical Union (AGU) in Space Weather
- Vol. 23 (9)
Open AccessLSTM‐Based Modeling of Radiation Belt Electrons Using MagEIS Observations From RBSP Satellites
This study presents the development and validation of a Long Short‐Term Memory neural network model for predicting electron fluxes within the Earth's radiation belts, specifically covering an electron energy range from 33 to 2,619 keV, using data from the Magnetic Electron Ion Spectrometer onboard the Van Allen Probes (RBSP). By inputting a time series of historical solar wind conditions and geomagnetic indices, along with satellite location parameters and pitch angle, the model reproduces observed electron fluxes. A Spearman correlation analysis was performed to determine an optimal 300‐hr time series length, which accommodates the longer lag times associated with higher‐energy electrons. The model maintains an uncertainty factor within 2 across all energy ranges in the outer radiation belt and achieves its best performance at the 597 keV energy channel, with a prediction efficiency of 0.97 and a Root Mean Square Error of 0.166 log10(Flux). To further examine the model's robustness under complex geomagnetic conditions, we predicted electron fluxes during three distinct magnetic storm events. Even under these challenging conditions, the model consistently reproduced observed flux variations with high fidelity and relatively low errors. The discrepancies were primarily confined to the transition zones between high‐flux and low‐flux regions. In addition, we validated the model against an independent data set from the Arase satellite in 2018. At an energy of 1,064 keV, the predicted fluxes achieved a Pearson correlation coefficient of 0.831 with observations, demonstrating the model's strong generalization capability across different instruments and data sets.