Huanming Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Huanming Wu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Jiancheng Yu
Zhejiang Provincial Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis, Institute of Mass Spectrometry Ningbo University Ningbo P. R. China
4 shared publications- Keqi Tang
Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application. Institute of Mass Spectrometry, School of Materials Science & Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China
4 shared publications Chenlu Wang
Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, Ningbo University, Ningbo, China
3 shared publications- Junliang Zhang
Beijing National Laboratory for Condensed Matter Physics and Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications Tao Yin
Institute of Semiconductors, Chinese Academy of Sciences, Beijing, China
2 shared publicationsBaichun Wang
School of Materials Science and Chemical Engineering, Institute of Mass Spectrometry Ningbo University Ningbo China
1 shared publication
Latest Publications
- 17 November 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (24) , 5764-5774
Genetic algorithm parallel optimization of a new high mass resolution planar electrostatic ion trap mass analyzer
The study and design of high-resolution mass analyzers is a very important task in mass spectrometry. A planar electrostatic ion trap (PEIT) mass analyzer with image charge detection and FT-based data processing has been developed, theoretically simulated, and experimentally validated. However, the 10 ring electrode configuration (PEIT-10) is difficult for mechanical construction and voltage tuning; moreover, few methods have been reported for optimizing the performance of multi-electrode mass analyzers. In this article, a simplified PEIT-7 mass analyzer was designed, and a genetic algorithm parallel optimization (GAPO) method was developed for optimizing multiple voltage settings of the new PEIT-7 mass analyzer to achieve spatial and energy isochronicity as well as iso-coordinate property. The automatic voltage optimization processes for the reduction of time aberration and spatial aberration showed that the developed GAPO method can significantly improve the optimization efficiency (the optimal voltage set being found within 5 hours with a maximum time aberration of 15 ps and a maximum z aberration of 0.10 μm). Based on the results obtained from the GAPO method, the resolving power of the PEIT-7 mass analyzer for six groups of ions with closely packed masses (m/z = 117.000 Th to 117.010 Th) was demonstrated, and a mass resolution of 171k was achieved at an acquisition time of 200 ms. The established GAPO method facilitates the design and optimization of high-resolution mass analyzers and may be useful for the design of other multi-electrode ion optical devices.
- 17 November 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (24) , 5764-5774
Genetic algorithm parallel optimization of a new high mass resolution planar electrostatic ion trap mass analyzer
The study and design of high-resolution mass analyzers is a very important task in mass spectrometry. A planar electrostatic ion trap (PEIT) mass analyzer with image charge detection and FT-based data processing has been developed, theoretically simulated, and experimentally validated. However, the 10 ring electrode configuration (PEIT-10) is difficult for mechanical construction and voltage tuning; moreover, few methods have been reported for optimizing the performance of multi-electrode mass analyzers. In this article, a simplified PEIT-7 mass analyzer was designed, and a genetic algorithm parallel optimization (GAPO) method was developed for optimizing multiple voltage settings of the new PEIT-7 mass analyzer to achieve spatial and energy isochronicity as well as iso-coordinate property. The automatic voltage optimization processes for the reduction of time aberration and spatial aberration showed that the developed GAPO method can significantly improve the optimization efficiency (the optimal voltage set being found within 5 hours with a maximum time aberration of 15 ps and a maximum z aberration of 0.10 μm). Based on the results obtained from the GAPO method, the resolving power of the PEIT-7 mass analyzer for six groups of ions with closely packed masses (m/z = 117.000 Th to 117.010 Th) was demonstrated, and a mass resolution of 171k was achieved at an acquisition time of 200 ms. The established GAPO method facilitates the design and optimization of high-resolution mass analyzers and may be useful for the design of other multi-electrode ion optical devices.
- 13 October 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (1) , e9211
Application of zero‐phase digital filtering for effective denoising of field asymmetric waveform ion mobility spectrometry signal
Rationale: Field asymmetric waveform ion mobility spectrometry (FAIMS) has a great potential to become a portable technology for rapid detection of chemical and biological agents. However, the ion current signals, measured at the exit of the planar FAIMS directly, may contain different types of noises. The peak information in the FAIMS spectrum, such as the compensation voltage (CV) value at the maximum peak intensity ( CV P ) and the peak width at half maximum ( W h ), could not be accurately determined under the weak signal condition, which significantly limits the achievable instrument sensitivity, and there are no existing solutions to the problem. Methods: This study analyzed the noise type of FAIMS signal in detail, and three different signal processing algorithms, such as median filtering (MF), discrete wavelet transform (DWT), and zero‐phase digital filtering (ZDF), were evaluated for their performance in denoising the FAIMS signal. Results: The results show that the standard deviation of CV p obtained from the signal denoised using ZDF algorithm is at least 31.82% smaller as compared to using MF and DWT algorithms. The standard deviation of W h is at least 45.45% smaller using ZDF algorithm. Moreover, only ZDF algorithm can keep the percentage error for the CV value of the denoised signal to be within 0.50 ± 0.47% of the true CV value, implying the effectiveness of ZDF algorithm in denoising while retaining the integrity of the signal. Conclusions: The ZDF algorithm greatly reduces the analyte peak extraction error and improves the limit of detection in FAIMS measurements.
- 13 October 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (1) , e9211
Application of zero‐phase digital filtering for effective denoising of field asymmetric waveform ion mobility spectrometry signal
Rationale: Field asymmetric waveform ion mobility spectrometry (FAIMS) has a great potential to become a portable technology for rapid detection of chemical and biological agents. However, the ion current signals, measured at the exit of the planar FAIMS directly, may contain different types of noises. The peak information in the FAIMS spectrum, such as the compensation voltage (CV) value at the maximum peak intensity ( CV P ) and the peak width at half maximum ( W h ), could not be accurately determined under the weak signal condition, which significantly limits the achievable instrument sensitivity, and there are no existing solutions to the problem. Methods: This study analyzed the noise type of FAIMS signal in detail, and three different signal processing algorithms, such as median filtering (MF), discrete wavelet transform (DWT), and zero‐phase digital filtering (ZDF), were evaluated for their performance in denoising the FAIMS signal. Results: The results show that the standard deviation of CV p obtained from the signal denoised using ZDF algorithm is at least 31.82% smaller as compared to using MF and DWT algorithms. The standard deviation of W h is at least 45.45% smaller using ZDF algorithm. Moreover, only ZDF algorithm can keep the percentage error for the CV value of the denoised signal to be within 0.50 ± 0.47% of the true CV value, implying the effectiveness of ZDF algorithm in denoising while retaining the integrity of the signal. Conclusions: The ZDF algorithm greatly reduces the analyte peak extraction error and improves the limit of detection in FAIMS measurements.
- 10 May 2021
- Published by Taylor & Francis in Analytical Letters
- Vol. 55 (2) , 215-225
Enhanced Sensitivity and Precision of Portable Mass Spectrometry (MS) with a Discontinuous Atmospheric Pressure Interface by Multiple Ion Injection
The detection limit is one of the most important performance characteristics for portable mass spectrometers (MS). To significantly reduce the size and the weight, small vacuum pumps are used in portable MS which leads to the use of a discontinuous atmospheric pressure interface (DAPI). Multiple ion injections (M-DAPI), which accumulates ions through opening the DAPI pinch valve several times during the ion injection period while maintaining a radio frequency (RF) voltage continuously on the trap, was shown to improve the sensitivity of DAPI-based portable MS. A systematic investigation of the optimization of M-DAPI was performed. The primary parameters affecting the performance of M-DAPI were optimized and sensitivity and stability improvements are reported. An 11.6-fold improvement in sensitivity was achieved by M-DAPI compared to the single ion injection DAPI operation for 1 μg/mL enrofloxacin. A more than 10-fold reduction in the limit of detection (LOD) to 0.01 μg/mL was also obtained. In addition, the stability was improved by M-DAPI with a relative standard deviation of 14.4% compared to 4.6% for DAPI.
- 10 May 2021
- Published by Taylor & Francis in Analytical Letters
- Vol. 55 (2) , 215-225
Enhanced Sensitivity and Precision of Portable Mass Spectrometry (MS) with a Discontinuous Atmospheric Pressure Interface by Multiple Ion Injection
The detection limit is one of the most important performance characteristics for portable mass spectrometers (MS). To significantly reduce the size and the weight, small vacuum pumps are used in portable MS which leads to the use of a discontinuous atmospheric pressure interface (DAPI). Multiple ion injections (M-DAPI), which accumulates ions through opening the DAPI pinch valve several times during the ion injection period while maintaining a radio frequency (RF) voltage continuously on the trap, was shown to improve the sensitivity of DAPI-based portable MS. A systematic investigation of the optimization of M-DAPI was performed. The primary parameters affecting the performance of M-DAPI were optimized and sensitivity and stability improvements are reported. An 11.6-fold improvement in sensitivity was achieved by M-DAPI compared to the single ion injection DAPI operation for 1 μg/mL enrofloxacin. A more than 10-fold reduction in the limit of detection (LOD) to 0.01 μg/mL was also obtained. In addition, the stability was improved by M-DAPI with a relative standard deviation of 14.4% compared to 4.6% for DAPI.
- 9 April 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (12) , e9099
Hollow electrode capillary plasma ionization source for rapid online detection of gaseous samples
RATIONALE: Gas chromatography mass spectrometry (GC‐MS) with electron ionization (EI) is the most widely used analysis technique of gaseous samples, but it may be time‐consuming for online monitoring of mixtures whose concentrations relatively change rapidly. On the contrary, current ionization methods, such as chemical ionization (CI) and proton transfer reaction (PTR), also have some disadvantages such as selectivity. Therefore, appropriate soft ionization sources are searched for rapid online detection. METHODS: Hollow electrode capillary plasma ionization (HECPI) is based on single electrode plasma. A hollow capillary was placed as both the electrode and the inlet of the gaseous samples. The ionization source is coupled with a mass spectrometer for performance evaluation. RESULTS: Several typical compounds have been tested with HECPI‐mass spectrometer. In this process, the dominant ion peaks of all compounds can be indexed as molecular ion peaks, and the product ions of HECPI are less than that of dielectric barrier discharge ionization (DBDI). Three gaseous samples (linalool, triethylamine, and styrene) with various concentrations have been used to further confirm the performance of this source, and the detection limit of linalool is as low as 10 ppb. CONCLUSIONS: HECPI is simple in structure and shows good performance. The results also show that HECPI has the potential to be an effective tool for detecting online gaseous samples rapidly.
- 9 April 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (12) , e9099
Hollow electrode capillary plasma ionization source for rapid online detection of gaseous samples
RATIONALE: Gas chromatography mass spectrometry (GC‐MS) with electron ionization (EI) is the most widely used analysis technique of gaseous samples, but it may be time‐consuming for online monitoring of mixtures whose concentrations relatively change rapidly. On the contrary, current ionization methods, such as chemical ionization (CI) and proton transfer reaction (PTR), also have some disadvantages such as selectivity. Therefore, appropriate soft ionization sources are searched for rapid online detection. METHODS: Hollow electrode capillary plasma ionization (HECPI) is based on single electrode plasma. A hollow capillary was placed as both the electrode and the inlet of the gaseous samples. The ionization source is coupled with a mass spectrometer for performance evaluation. RESULTS: Several typical compounds have been tested with HECPI‐mass spectrometer. In this process, the dominant ion peaks of all compounds can be indexed as molecular ion peaks, and the product ions of HECPI are less than that of dielectric barrier discharge ionization (DBDI). Three gaseous samples (linalool, triethylamine, and styrene) with various concentrations have been used to further confirm the performance of this source, and the detection limit of linalool is as low as 10 ppb. CONCLUSIONS: HECPI is simple in structure and shows good performance. The results also show that HECPI has the potential to be an effective tool for detecting online gaseous samples rapidly.
- 1 October 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (1) , 124-131
On a separation voltage polarity switching transient capillary isotachophoresis method for higher sample loading capacity and better separation performance
Mechanism of a PS-tCITP method with higher sample loading capacity and better separation performance.
- 1 October 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (1) , 124-131
On a separation voltage polarity switching transient capillary isotachophoresis method for higher sample loading capacity and better separation performance
Mechanism of a PS-tCITP method with higher sample loading capacity and better separation performance.
- 7 July 2020
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 34 (20) , e8881
In situ synthesis of a novel metal oxide affinity chromatography affinity probe for the selective enrichment of low‐abundance phosphopeptides
Rationale: Due to the dynamic nature of phosphorylation states and the low stoichiometry of phosphopeptides, it is still a challenge to efficiently capture phosphopeptides from complex biological samples before mass spectrometry analysis. Among the enrichment strategies, metal oxide affinity chromatography (MOAC) is one of the most widely used and the one with the most potential. It is based on reversible Lewis acid–base interactions between the metal oxides and the negatively charged phosphate groups to achieve the specific selection of phosphopeptides. Methods: A novel MOAC affinity probe, denoted as G@PDA@ZrO 2 , was successfully synthesized by in situ grafting ZrO 2 onto the surface of graphene (G) modified with polydopamine (PDA). The novel MOAC probe thus obtained was used for phosphopeptide enrichment. Results: This novel MOAC affinity probe when used to selectively enrich phosphopeptides from standard protein digest solutions exhibited a high selectivity (β‐casein:bovine serum albumin = 1:1000), a low detection limit (4 fmol), and a high loading capacity (400 mg/g). At the same time, the experimental results proved that G@PDA@ZrO 2 had great recyclability (five cycles), stability, and reproducibility. Subsequently, G@PDA@ZrO 2 was applied to enrich phosphopeptides from human saliva and human serum, in which 25 and 4 phosphopeptide peaks, respectively, were detected. Conclusions: This novel MOAC affinity probe (G@PDA@ZrO 2 ) showed good performance in enriching phosphopeptides. Thus, G@PDA@ZrO 2 has good potential in phosphopeptidomics analysis.
- 7 July 2020
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 34 (20) , e8881
In situ synthesis of a novel metal oxide affinity chromatography affinity probe for the selective enrichment of low‐abundance phosphopeptides
Rationale: Due to the dynamic nature of phosphorylation states and the low stoichiometry of phosphopeptides, it is still a challenge to efficiently capture phosphopeptides from complex biological samples before mass spectrometry analysis. Among the enrichment strategies, metal oxide affinity chromatography (MOAC) is one of the most widely used and the one with the most potential. It is based on reversible Lewis acid–base interactions between the metal oxides and the negatively charged phosphate groups to achieve the specific selection of phosphopeptides. Methods: A novel MOAC affinity probe, denoted as G@PDA@ZrO 2 , was successfully synthesized by in situ grafting ZrO 2 onto the surface of graphene (G) modified with polydopamine (PDA). The novel MOAC probe thus obtained was used for phosphopeptide enrichment. Results: This novel MOAC affinity probe when used to selectively enrich phosphopeptides from standard protein digest solutions exhibited a high selectivity (β‐casein:bovine serum albumin = 1:1000), a low detection limit (4 fmol), and a high loading capacity (400 mg/g). At the same time, the experimental results proved that G@PDA@ZrO 2 had great recyclability (five cycles), stability, and reproducibility. Subsequently, G@PDA@ZrO 2 was applied to enrich phosphopeptides from human saliva and human serum, in which 25 and 4 phosphopeptide peaks, respectively, were detected. Conclusions: This novel MOAC affinity probe (G@PDA@ZrO 2 ) showed good performance in enriching phosphopeptides. Thus, G@PDA@ZrO 2 has good potential in phosphopeptidomics analysis.
- Open Access
- 2 March 2020
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-13
An Optimal Backoff Time-Based Internetwork Interference Mitigation Method in Wireless Body Area Network
When multiple Wireless Body Area Networks (WBANs) are aggregated, the overlapping region of their communications will result in internetwork interference, which could impose severe impacts on the reliability of WBAN performance. Therefore, how to mitigate the internetwork interference becomes the key problem to be solved urgently in practical applications of WBAN. However, most of the current researches on internetwork interference focus on traditional cellular networks and large-scale wireless sensor networks. In this paper, an Optimal Backoff Time Interference Mitigation Algorithm (OBTIM) is proposed. This method performs rescheduling or channel switching when the performance of the WBANs falls below tolerance, utilizing the cell neighbour list established by the beacon method. Simulation results show that the proposed method improves the channel utilization and the network throughput, and in the meantime, reduces the collision probability and energy consumption, when compared with the contention-based beacon schedule scheme.
- 2 March 2020
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-13
Open AccessAn Optimal Backoff Time-Based Internetwork Interference Mitigation Method in Wireless Body Area Network
When multiple Wireless Body Area Networks (WBANs) are aggregated, the overlapping region of their communications will result in internetwork interference, which could impose severe impacts on the reliability of WBAN performance. Therefore, how to mitigate the internetwork interference becomes the key problem to be solved urgently in practical applications of WBAN. However, most of the current researches on internetwork interference focus on traditional cellular networks and large-scale wireless sensor networks. In this paper, an Optimal Backoff Time Interference Mitigation Algorithm (OBTIM) is proposed. This method performs rescheduling or channel switching when the performance of the WBANs falls below tolerance, utilizing the cell neighbour list established by the beacon method. Simulation results show that the proposed method improves the channel utilization and the network throughput, and in the meantime, reduces the collision probability and energy consumption, when compared with the contention-based beacon schedule scheme.
- 6 November 2017
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 94 (2) , 195-204
A closed-loop interface for capacitive micro-accelerometers with pulse-width-modulation force feedback
- 6 November 2017
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 94 (2) , 195-204
A closed-loop interface for capacitive micro-accelerometers with pulse-width-modulation force feedback