YCYuan Chen

Yuan Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuan Chen has a total of 122 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation

    by Jialin Huang, Shuai Hu, Can Mo, Yuanchun Ye, Tengda Zhang, Zhitao Dai, Yongsheng Huang, Yuan Chen, Jinfen Zheng, Jinghui Wang, et al.

    Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.

  • Simulation study on the dosimetric characteristics of focused electron beams with different energies for FLASH radiotherapy

    by Xiong Tan, Chaofan An, Ruoyu Qin, Zeyi Dai, Jia Li, Yuan Chen, Jike Wang, Dazhen Jiang, Hui Liu, Yuancun Nie

    Objective Focused high-energy electron beams are a promising option for FLASH radiotherapy of deep-seated tumors because beam focusing may improve dose concentration at depth while reducing unnecessary irradiation of surrounding normal tissues. This study aimed to investigate the dosimetric characteristics of focused electron beams for FLASH radiotherapy and to provide insight into electron beam energy selection. Approach An electron beam focusing system was developed, with the beam transport line optimized using the Transport code. The dosimetric performance of 1 GeV, 500 MeV, and 200 MeV electron beams passing through this system was systematically simulated in a water phantom using the Monte-Carlo code FLUKA. The dose distributions of beams with different energies were quantitatively compared under the same optical configuration. Main results Among the investigated beam energies, the 1 GeV electron beam exhibited the strongest focusing capability and achieved the minimum full width at half maximum (FWHM) at the focal point, offering unique advantages for spatially fractionated radiotherapy (SFRT). The 500 MeV beam showed only a limited increase in focal size and FWHM compared with the 1 GeV beam, whereas the 200 MeV beam exhibited relatively poor focusing performance in deep regions. Consequently, the 500 MeV electron beam may represent a viable substitute for the 1 GeV beam in specific clinical or engineering environments, as it provides a favorable balance between dosimetric performance and implementation cost.. Significance The systematic analysis of the dosimetric characteristics of electron beams at different energies provided in this study can serve as a valuable reference for related research and for the future clinical implementation of FLASH radiotherapy based on high energy electron beams.

  • Design Optimization of Hybrid-Laminated Fast-Scanning Magnets for the Carbon-Ion Radiotherapy

    by Ben Fan, Bin Tang, Chenyang Gong, Guo Peng, Pai Xiang, Geng Wei, Yuan Chen, Xianhu Zeng, Rong Zhou, Ruicheng Yan, et al.

    Scanning magnets are devices responsible for deflecting particles to specific locations in particle therapy utilizing spot-scanning techniques. To maintain scanned beam-spot distortion at the isocenter plane within an acceptable threshold, sufficient field-integral homogeneity must be guaranteed in both transverse dimensions across the good field region. Typically, this is accomplished by adding shims on both sides of magnet poles. In this study, we innovatively proposed a method for multi-objective optimization of shim parameters and excitation currents using the state-of-the-art evolutionary algorithm, Non-dominated Sorting Genetic Algorithm-III (NSGA-III), to facilitate an efficient optimization process. After that, beam tracking has been employed to assess the beam-spot distortion. By implementing these methods, we successfully developed an optimal Y-axis scanning magnet (SMY) using hybrid-laminated silicon steels. Designed for a fast scanning speed of up to 80 mm/ms, this magnet can deliver a 400 MeV/u carbon-ion beam to cover a 20 cm × 20 cm irradiation field at a source-to-axis distance (SAD) of 255 cm. Compared to the manually tuned SMY configuration, the automated optimization process achieved a 78.80% homogeneity enhancement in the good field region at the midplane. This advanced high-performance magnet, designed for integration with the next-generation lightweight superconducting rotating gantry, is a pioneering accelerator magnet developed through intelligent algorithm-driven optimization. Static magnetic field measurements conclusively demonstrate the manufacturability of this genetically optimized magnet within existing CNC machining frameworks, and show good agreement with simulation results. Furthermore, the development of the X-axis scanning magnet (SMX) is also discussed.

  • Pump characteristics and degradation performance of a multilayer Ti–Zr–V film deposited on narrow tube

    by Jian Li, Geng Wei, Yuan Chen, Pai Xiang, Yuancun Nie, Jike Wang, Jianhua He

    Nonevaporable getter (NEG) thin films provide distributed pumping properties, a low thermal outgassing rate, and a low photon and electron stimulated desorption, enabling attainment of ultrahigh vacuum in narrow and conductance-limited chambers. This technology is an ideal solution to deal with conductance-limited narrow vacuum tubes in the fourth-generation accelerator for resolving the nonuniform pressure distribution. In this study, we successfully fabricated a multilayer film structure consisting of a dense inner layer and a columnar outer layer on the inner wall of the narrow tube via magnetron sputtering deposition. The test particle Monte Carlo model was employed to accurately evaluate the sticking probability of the NEG film based on the pressure reading during gas injection. Repeated activation-saturation cycles conducted on a tube coated with the NEG film revealed the degradation characteristics of H2 and CO pumping speed/capacity and the evolution patterns of performance. This investigation thus establishes essential guidelines for sustainable operational maintenance of vacuum systems in fourth-generation synchrotron radiation facilities.


  • Status of Multipole Magnets for Hefei Advanced Light Facility

    by Tianhao Sun, Hongliang Xu, Yuan Chen, Zhiliang Ren, Zijing Zhang, Baohou Liu, Guangyao Feng

    The design of the Hefei Advanced Light Facility storage ring is based on the utilization of numerous short and high-field magnets with relatively large apertures. This presents challenges in optimizing the design. To tackle this issue, a new optimization program was developed using the conformal mapping and nondominated sorting genetic algorithm II to determine the shape of the poles. This program ensures that all error multipole components within the good field region are maintained at a level of $10^{-5}$ in the physical design. Moreover, this method can be applied to different types of magnets. Considering that the high gradient quadrupole is commonly employed in ultralow emittance storage rings, it is vital to verify the algorithm's capability for achieving appropriate poles in this scenario. As a result, a 90 T/m quadrupole prototype was successfully designed and measured using this method.


  • Design and Measurement of a New Superbend-Magnet for WALS

    by Pai Xiang, Yuan Chen, Qiaogen Zhou, Yongzhou He, Jidong Zhang, Jingmin Zhang, Geng Wei, Jian Li, Jike Wang, Yuancun Nie, et al.

    In order to provide hard X-rays with a 1.5 GeV electron ring, a new superbend-magnet will be used in middle of each standard cell at Wuhan Advanced Light Source (WALS). Design, assembly, and detailed magnetic measurement of the prototype have been finished. The results of magnetic measurement show that central magnetic field reaches 3.67 T in a gap of 14.72 mm, and the range of high field region (>3.5 T) is larger than 40 mm in the longitudinal direction. The uniformity of the magnetic field integrals is below 5 × 10 −4 within the good field region.


  • Status of Magnets for WALS Storage Ring

    by Yuan Chen, Pai Xiang, Jingmin Zhang, Qiaogen Zhou, Jidong Zhang, Yong Zhou He, Geng Wei, Jian Li, Ye Zou, Yuancun Nie, et al.

    The accelerators of Wuhan Advanced Light Source (WALS) consist of a 1.5 GeV Linac, a 1.5 GeV storage ring (SR), and a single beam transport line. Due to the limited longitudinal space, the SR lattice incorporates many combined function magnets to optimize beam optics and minimize emittance. These magnets include horizontal and longitudinal gradient dipoles (LGB), electromagnetic and permanent hybrid dipoles (HYB), and anti-bending single-sided dipole-quadrupole magnets (ABM). This paper introduces the key designs and challenges of these magnets, and it also presents the field measurement results of prototypes for the HYD and ABM.


  • A Miniaturized Broadband High-performance RFID_tag

    by Yuan Chen, Fanchao Zeng, Tingting Lv, Zhi-Ya Zhang

    In this paper, a broadband high-performance UHF frequency band tag antenna based on miniaturization technology is proposed. The current path on the dipole antenna has been changed to achieve the miniaturization of the antenna, finally enhance the antennas bending resistance. The two arms extending from the tapered area near the feed point are tuned with a metal copper pillar, which allows the bandwidth of the antenna to be widened. The method of widening the bandwidth greatly improves the anti – medium ability of the tag antenna. The final tag antenna has 2.03dBi antenna gain in the band of 902Mhz $\sim 928$ Mhz, and a bandwidth of 66% ($\mathrm{S}11\lt-10$dB), while the antenna size is reduced by 53%. After processing and testing, the tag antenna can work on surfaces of water, biological tissue, metal, etc. And it has good anti-deformation characteristics, achieves the expected effect, and is in good agreement with the simulation results.