Kazuko Uchikawa Graziano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kazuko Uchikawa Graziano has a total of 270 co-authors. Here are the top co-authors by number of shared publications:
- Camila Quartim de Moraes Bruna
Universidade de São Paulo, Brazil; Universidade de São Paulo, Brazil
13 shared publications - Rafael Queiroz de Souza
Escola de Enfermagem da USP, São Paulo, SP
9 shared publications - Rúbia Aparecida Lacerda
Universidade de São Paulo, Brasil
5 shared publications - Paulo Roberto Laranjeira
Universidade de São Paulo, Brasil
4 shared publications - Rafael Queiroz de Souza
Centro Universitário São Camilo – São Paulo (SP), Brazil
4 shared publications - Jeane Aparecida Gonzalez Bronzatti
Enfermeira Doutorando da escola de enfermagem da universidade de São Paulo -São Paulo (SP) 1 engenheiro elétrico Brasil
3 shared publications
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in Infection Prevention in Practice
- Vol. 8 (4)
Comparative microbiological analysis between different types of privacy curtains using three sampling methods
- 24 October 2026
- Published by Elsevier in Infection Prevention in Practice
- Vol. 8 (4)
Open AccessComparative microbiological analysis between different types of privacy curtains using three sampling methods
- Open Access
- 19 May 2025
- Published by Universidade Federal de Pelotas in Journal of Nursing and Health
- Vol. 15 (2) , e1528493
Detecção de papilomavírus humano em probes de ultrassom transvaginal na região amazônica
Objetivo: verificar a presença de ácido desoxirribonucleico do Papilomavírus Humano em probes de ultrassom transvaginal. Método: estudo observacional, em que amostras foram coletadas das superfícies dos preservativos e probe transvaginal após exames realizados em 30 mulheres da região amazônica. Foram incluídas todas as utilizações do probe de ultrassom dos exames transvaginais realizados durante o período do estudo. Resultados: ácido desoxirribonucleico humano foi detectado em todas as amostras colhidas dos preservativos e, em 8 (26,6%) amostras, foi detectado ácido desoxirribonucleico de Papilomavírus Humano. Ácido desoxirribonucleico humano foi detectado em 1 das 30 amostras colhidas dos probes e Papilomavírus Humano não foi detectado. O único procedimento observado para descontaminar o probe entre os exames foi remoção do gel com papel e troca dos preservativos. Conclusões: a presença de Papilomavírus Humano nas amostras colhidas nos preservativos evidencia a necessidade de boas práticas para o controle da contaminação cruzada no manuseio dos probes.
- 19 May 2025
- Published by Universidade Federal de Pelotas in Journal of Nursing and Health
- Vol. 15 (2) , e1528493
Open AccessDetecção de papilomavírus humano em probes de ultrassom transvaginal na região amazônica
Objetivo: verificar a presença de ácido desoxirribonucleico do Papilomavírus Humano em probes de ultrassom transvaginal. Método: estudo observacional, em que amostras foram coletadas das superfícies dos preservativos e probe transvaginal após exames realizados em 30 mulheres da região amazônica. Foram incluídas todas as utilizações do probe de ultrassom dos exames transvaginais realizados durante o período do estudo. Resultados: ácido desoxirribonucleico humano foi detectado em todas as amostras colhidas dos preservativos e, em 8 (26,6%) amostras, foi detectado ácido desoxirribonucleico de Papilomavírus Humano. Ácido desoxirribonucleico humano foi detectado em 1 das 30 amostras colhidas dos probes e Papilomavírus Humano não foi detectado. O único procedimento observado para descontaminar o probe entre os exames foi remoção do gel com papel e troca dos preservativos. Conclusões: a presença de Papilomavírus Humano nas amostras colhidas nos preservativos evidencia a necessidade de boas práticas para o controle da contaminação cruzada no manuseio dos probes.
- Open Access
- 23 January 2025
- Published by Universidade Estadual de Maringa in Ciência, Cuidado e Saúde
- Vol. 24 (1)
Relação entre tecnologia e produtividade em centros de material e esterilização do Rio Grande do Sul
Objetivo: avaliar a relação entre a disponibilidade tecnológica e a produtividade em Centros de Material e Esterilização (CMEs), automatizados ou não, de hospitais do Rio Grande do Sul (RS). Método: Estudo transversal e analítico conduzido em 43 CMEs selecionados aleatoriamente, localizados no estado do RS, Brasil. Dados foram coletados através de entrevistas on-line com os gestores dos CME entre dezembro de 2022 e maio de 2023. A análise dos dados foi por estatística descritiva e inferencial. Resultados: Os CMEs são centralizados, com funcionamento ininterrupto e possuem disponibilidade tecnológica heterogênea, sendo 22 (51,2%) caracterizados como automatizados. Verificou-se uma associação significativa entre a disponibilidade tecnológica (automatização) e a produtividade dos CMEs. Verificou-se também uma associação significativa (p<0,05) e correlação positiva (Rho<0,65) entre a disponibilidade tecnológica, o porte hospitalar e a produção cirúrgica, embora tenham sido encontradas instituições com alta demanda cirúrgica e disponibilidade tecnológica limitada na área de limpeza, denotando um processo majoritariamente manual. Conclusão: Constatou-se uma relação positiva entre produtividade e automatização dos CMEs. Os automatizados demonstraram ser mais produtivos do que os exclusivamente manuais, inclusive quando comparados portes hospitalares semelhantes. A automatização do processo de limpeza deve ser propagada, pois reflete positivamente na produtividade não somente em números, mas na garantia de resultados reprodutíveis.
- 23 January 2025
- Published by Universidade Estadual de Maringa in Ciência, Cuidado e Saúde
- Vol. 24 (1)
Open AccessRelação entre tecnologia e produtividade em centros de material e esterilização do Rio Grande do Sul
Objetivo: avaliar a relação entre a disponibilidade tecnológica e a produtividade em Centros de Material e Esterilização (CMEs), automatizados ou não, de hospitais do Rio Grande do Sul (RS). Método: Estudo transversal e analítico conduzido em 43 CMEs selecionados aleatoriamente, localizados no estado do RS, Brasil. Dados foram coletados através de entrevistas on-line com os gestores dos CME entre dezembro de 2022 e maio de 2023. A análise dos dados foi por estatística descritiva e inferencial. Resultados: Os CMEs são centralizados, com funcionamento ininterrupto e possuem disponibilidade tecnológica heterogênea, sendo 22 (51,2%) caracterizados como automatizados. Verificou-se uma associação significativa entre a disponibilidade tecnológica (automatização) e a produtividade dos CMEs. Verificou-se também uma associação significativa (p<0,05) e correlação positiva (Rho<0,65) entre a disponibilidade tecnológica, o porte hospitalar e a produção cirúrgica, embora tenham sido encontradas instituições com alta demanda cirúrgica e disponibilidade tecnológica limitada na área de limpeza, denotando um processo majoritariamente manual. Conclusão: Constatou-se uma relação positiva entre produtividade e automatização dos CMEs. Os automatizados demonstraram ser mais produtivos do que os exclusivamente manuais, inclusive quando comparados portes hospitalares semelhantes. A automatização do processo de limpeza deve ser propagada, pois reflete positivamente na produtividade não somente em números, mas na garantia de resultados reprodutíveis.
- Open Access
- 7 February 2024
- Published by Zeppelini Editorial e Comunicacao in Revista Sobecc
- Vol. 29
Resistência à corrosão e citotoxicidade de aços inoxidáveis expostos a soluções de cloretos
Objetivo: Analisar a resistência à corrosão por pites dos aços inoxidáveis AISI 304 e AISI 420 em meio contendo cloretos (solução de NaCl a 0,9 e 3,5%, em massa), assim como sua citotoxicidade,in vitro, em amostras com e sem corrosão por pites. Método: Estudo experimental. Utilizaram-se técnicas de polarização potenciodinâmica cíclica (PPC) para caracterizar extensão e forma do ataque corrosivo nas amostras. O método de difusão em ágar e avaliação da viabilidade da linhagem celular NCTC clone 929 (CCIAL 020) foi empregado para avaliar a citotoxicidade de amostras dos aços com e sem pites. Resultados: O aço AISI 304 apresentou resistência à corrosão superior ao aço AISI 420. Os valores dos potenciais de pite caíram para ambos os aços quando se aumentou a concentração de cloretos na solução agressiva. Houve moderada toxicidade celular (grau 3 — ISO 10993-5) em todas as amostras. Conclusão: Os resultados corroboraram as recomendações para evitar a imersão desnecessária dos instrumentais em soluções salinas. A citotoxicidade moderada para esses aços contraindica seu uso em dispositivos implantáveis, apenas em instrumentos cirúrgicos.
- 7 February 2024
- Published by Zeppelini Editorial e Comunicacao in Revista Sobecc
- Vol. 29
Open AccessResistência à corrosão e citotoxicidade de aços inoxidáveis expostos a soluções de cloretos
Objetivo: Analisar a resistência à corrosão por pites dos aços inoxidáveis AISI 304 e AISI 420 em meio contendo cloretos (solução de NaCl a 0,9 e 3,5%, em massa), assim como sua citotoxicidade,in vitro, em amostras com e sem corrosão por pites. Método: Estudo experimental. Utilizaram-se técnicas de polarização potenciodinâmica cíclica (PPC) para caracterizar extensão e forma do ataque corrosivo nas amostras. O método de difusão em ágar e avaliação da viabilidade da linhagem celular NCTC clone 929 (CCIAL 020) foi empregado para avaliar a citotoxicidade de amostras dos aços com e sem pites. Resultados: O aço AISI 304 apresentou resistência à corrosão superior ao aço AISI 420. Os valores dos potenciais de pite caíram para ambos os aços quando se aumentou a concentração de cloretos na solução agressiva. Houve moderada toxicidade celular (grau 3 — ISO 10993-5) em todas as amostras. Conclusão: Os resultados corroboraram as recomendações para evitar a imersão desnecessária dos instrumentais em soluções salinas. A citotoxicidade moderada para esses aços contraindica seu uso em dispositivos implantáveis, apenas em instrumentos cirúrgicos.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Enfermagem
- Vol. 77 (4) , e20240021
Construction and validation of an instrument for event-related sterility of processed healthcare products
Objective: To construct and validate an instrument to assess events related to maintaining the sterility of processed healthcare products. Methods: This methodological study developed the instrument through analysis by a panel of experts, focusing on the integrity of commonly used packaging: spunbond-meltblown-spunbond and medical-grade paper. The instrument was analyzed using the Content Validity Index and Content Validity Ratio (≥ 0.80) and modified Kappa (≥ 0.74). The instrument underwent pre-testing. Results: Six experienced professionals participated in the expert panel. After two rounds, the final version of the instrument contained five dimensions. In the pre-test, 30 nursing professionals participated, of whom 86.67% considered the instrument good, and 90% found it understandable. Conclusion: The construction and validation followed literature recommendations. The instrument is available, aiding in the safe use of processed healthcare products.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Enfermagem
- Vol. 77 (4) , e20240021
Open AccessConstruction and validation of an instrument for event-related sterility of processed healthcare products
Objective: To construct and validate an instrument to assess events related to maintaining the sterility of processed healthcare products. Methods: This methodological study developed the instrument through analysis by a panel of experts, focusing on the integrity of commonly used packaging: spunbond-meltblown-spunbond and medical-grade paper. The instrument was analyzed using the Content Validity Index and Content Validity Ratio (≥ 0.80) and modified Kappa (≥ 0.74). The instrument underwent pre-testing. Results: Six experienced professionals participated in the expert panel. After two rounds, the final version of the instrument contained five dimensions. In the pre-test, 30 nursing professionals participated, of whom 86.67% considered the instrument good, and 90% found it understandable. Conclusion: The construction and validation followed literature recommendations. The instrument is available, aiding in the safe use of processed healthcare products.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Enfermagem
- Vol. 77 (4) , e20240021
Construção e validação de instrumento para esterilidade relacionada a eventos de produtos para saúde processados
RESUMO Objetivo: Construir e validar instrumento para avaliar evento relacionado à manutenção da esterilidade de produtos para saúde processados. Métodos: Estudo metodológico para desenvolver instrumento mediante análise por comitê de juízes. Considerou-se como aspecto norteador a integridade das embalagens mais utilizadas na prática: a de não tecido e a de papel grau cirúrgico. A análise foi realizada pelo Índice de Validade de Conteúdo, Razão de Validade de Conteúdo ≥ 0,80 e Kappa modificado ≥ 0,74. Submeteu-se o instrumento ao pré-teste. Resultados: Participaram do comitê de juízes seis profissionais experientes na temática. Após duas rodadas, chegou-se à versão final do instrumento, contendo cinco dimensões. No pré-teste, participaram 30 profissionais de enfermagem, dos quais 86,67% consideraram o instrumento bom; e 90%, compreensível. Conclusões: A construção e validação seguiu as recomendações da literatura. O instrumento está disponível para ser utilizado, auxiliando no uso seguro do produto para saúde.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Enfermagem
- Vol. 77 (4) , e20240021
Open AccessConstrução e validação de instrumento para esterilidade relacionada a eventos de produtos para saúde processados
RESUMO Objetivo: Construir e validar instrumento para avaliar evento relacionado à manutenção da esterilidade de produtos para saúde processados. Métodos: Estudo metodológico para desenvolver instrumento mediante análise por comitê de juízes. Considerou-se como aspecto norteador a integridade das embalagens mais utilizadas na prática: a de não tecido e a de papel grau cirúrgico. A análise foi realizada pelo Índice de Validade de Conteúdo, Razão de Validade de Conteúdo ≥ 0,80 e Kappa modificado ≥ 0,74. Submeteu-se o instrumento ao pré-teste. Resultados: Participaram do comitê de juízes seis profissionais experientes na temática. Após duas rodadas, chegou-se à versão final do instrumento, contendo cinco dimensões. No pré-teste, participaram 30 profissionais de enfermagem, dos quais 86,67% consideraram o instrumento bom; e 90%, compreensível. Conclusões: A construção e validação seguiu as recomendações da literatura. O instrumento está disponível para ser utilizado, auxiliando no uso seguro do produto para saúde.
- Open Access
- 20 January 2023
- Published by Acta Paulista de Enfermagem in Acta Paulista de Enfermagem
- Vol. 36
Avaliação do desempenho de detergentes para limpeza: validação de uma proposta
Resumo Objetivo Elaborar e validar uma proposta para avaliação do desempenho de detergentes na limpeza de produtos para saúde. Métodos Foi desenvolvida proposta para avaliar o desempenho de detergentes rotineiramente utilizados em Centros de Material e Esterilização por meio de um estudo experimental utilizando monitores de limpeza e lavadora ultrassônica. Monitores de limpeza foram dispostos na cuba de uma lavadora ultrassônica. O parâmetro adotado para avaliação do desempenho dos detergentes foi a remoção completa da sujidade dos monitores. Foram avaliados [...] Resumo Objetivo Elaborar e validar uma proposta para avaliação do desempenho de detergentes na limpeza de produtos para saúde. Métodos Foi desenvolvida proposta para avaliar o desempenho de detergentes rotineiramente utilizados em Centros de Material e Esterilização por meio de um estudo experimental utilizando monitores de limpeza e lavadora ultrassônica. Monitores de limpeza foram dispostos na cuba de uma lavadora ultrassônica. O parâmetro adotado para avaliação do desempenho dos detergentes foi a remoção completa da sujidade dos monitores. Foram avaliados
- 20 January 2023
- Published by Acta Paulista de Enfermagem in Acta Paulista de Enfermagem
- Vol. 36
Open AccessAvaliação do desempenho de detergentes para limpeza: validação de uma proposta
Resumo Objetivo Elaborar e validar uma proposta para avaliação do desempenho de detergentes na limpeza de produtos para saúde. Métodos Foi desenvolvida proposta para avaliar o desempenho de detergentes rotineiramente utilizados em Centros de Material e Esterilização por meio de um estudo experimental utilizando monitores de limpeza e lavadora ultrassônica. Monitores de limpeza foram dispostos na cuba de uma lavadora ultrassônica. O parâmetro adotado para avaliação do desempenho dos detergentes foi a remoção completa da sujidade dos monitores. Foram avaliados [...] Resumo Objetivo Elaborar e validar uma proposta para avaliação do desempenho de detergentes na limpeza de produtos para saúde. Métodos Foi desenvolvida proposta para avaliar o desempenho de detergentes rotineiramente utilizados em Centros de Material e Esterilização por meio de um estudo experimental utilizando monitores de limpeza e lavadora ultrassônica. Monitores de limpeza foram dispostos na cuba de uma lavadora ultrassônica. O parâmetro adotado para avaliação do desempenho dos detergentes foi a remoção completa da sujidade dos monitores. Foram avaliados
- Open Access
Evaluation of the Presence of Biofilms in Corrosive Points in Surgical Instruments after Reprocessing
Corrosive surgical instruments are routinely observed in central sterile services departments around the world. In addition to other risks, they can harbor microorganisms in the form of biofilms. Thus, this study aimed to evaluate whether biofilms intentionally formed at corrosion points on surgical instruments are removable by manual and automated cleaning followed by sterilization. Laboratory experiments were performed where samples of corroded surgical instruments in use in practice were evaluated for biofilm presence using a scanning electron microscope. No biofilms were observed in the samples subjected to manual and automated cleaning, nor in the samples in which there was no intentional biofilm formation. Residual organic matter without the presence of microorganisms was observed.
Open AccessEvaluation of the Presence of Biofilms in Corrosive Points in Surgical Instruments after Reprocessing
Corrosive surgical instruments are routinely observed in central sterile services departments around the world. In addition to other risks, they can harbor microorganisms in the form of biofilms. Thus, this study aimed to evaluate whether biofilms intentionally formed at corrosion points on surgical instruments are removable by manual and automated cleaning followed by sterilization. Laboratory experiments were performed where samples of corroded surgical instruments in use in practice were evaluated for biofilm presence using a scanning electron microscope. No biofilms were observed in the samples subjected to manual and automated cleaning, nor in the samples in which there was no intentional biofilm formation. Residual organic matter without the presence of microorganisms was observed.
- Open Access
- 8 April 2022
- Published by Zeppelini Editorial e Comunicacao in Revista Sobecc
- Vol. 26 (4)
Fatores relacionados à qualidade do vapor para esterilização de produtos para saúde
Objetivos: Identificar e discutir os fatores relacionados à qualidade do vapor e sua relação com as práticas do cotidiano do Centro de Material e Esterilização. Método: Pesquisa documental, construída com base na análise do referencial teórico normativo sobre a qualidade do vapor para esterilização de produtos para saúde. Resultados: Os fatores que estão diretamente relacionados à qualidade do vapor são: água de alimentação, contaminantes do vapor, flutuações de pressão na rede, gases não condensáveis, título e superaquecimento. Conclusão: O controle de fatores que impactam o sucessode esterilização por vapor não é uma atribuição única da engenharia clínica, mas sim uma responsabilidade compartilhada com o gestor do centro demateriais. A segurança na esterilização pelo vapor não deve ser reduzida ao controle de tempo, à temperatura ou ao resultado de indicadores físicos, químicos e biológicos, mas incluir o controle da qualidade do vapor, que é o agente esterilizante.Palavras-chave: Esterilização. Vapor. Controle de qualidade. Gestão da qualidade
- 8 April 2022
- Published by Zeppelini Editorial e Comunicacao in Revista Sobecc
- Vol. 26 (4)
Open AccessFatores relacionados à qualidade do vapor para esterilização de produtos para saúde
Objetivos: Identificar e discutir os fatores relacionados à qualidade do vapor e sua relação com as práticas do cotidiano do Centro de Material e Esterilização. Método: Pesquisa documental, construída com base na análise do referencial teórico normativo sobre a qualidade do vapor para esterilização de produtos para saúde. Resultados: Os fatores que estão diretamente relacionados à qualidade do vapor são: água de alimentação, contaminantes do vapor, flutuações de pressão na rede, gases não condensáveis, título e superaquecimento. Conclusão: O controle de fatores que impactam o sucessode esterilização por vapor não é uma atribuição única da engenharia clínica, mas sim uma responsabilidade compartilhada com o gestor do centro demateriais. A segurança na esterilização pelo vapor não deve ser reduzida ao controle de tempo, à temperatura ou ao resultado de indicadores físicos, químicos e biológicos, mas incluir o controle da qualidade do vapor, que é o agente esterilizante.Palavras-chave: Esterilização. Vapor. Controle de qualidade. Gestão da qualidade
- 1 February 2022
- Published by Elsevier in Journal of Hospital Infection
- Vol. 120, 117-122
Specialists' opinion regarding factors related to wet loads after steam sterilization
- 1 February 2022
- Published by Elsevier in Journal of Hospital Infection
- Vol. 120, 117-122
Specialists' opinion regarding factors related to wet loads after steam sterilization