Rahul Nadda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rahul Nadda has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Ashish Kumar Sahani
Department of Biomedical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
4 shared publications - Diganta Bhusan Das
Chemical Engineering Department, Loughborough University, Loughborough LE11 3TU, UK
3 shared publications - Ramjee Repaka
Department of Mechanical Engineering, Indian Institute of Technology Ropar , Punjab 140001, India ; , Punjab 140001, India
3 shared publications Ramjee Repaka
Department of Biomedical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
2 shared publications- Ryan F. Donnelly
School of Pharmacy, Queen’s University Belfast, Belfast, UK
2 shared publications Abraham M. Abraham
School of Pharmacy, Queen's University Belfast, Medical Biology Centre, Belfast BT9 7BL, UK
1 shared publication
Latest Publications
- 21 July 2026
- Published by Taylor & Francis
- p. 121-130
Sustainable Development with Additive Manufactured Materials
Additive manufacturing (AM), also referred to as 3D printing, is arguably one of the emerging technologies that has fundamentally changed the paradigm of sustainable growth. AM technology strives to achieve material efficiency by allowing complex geometries to be fabricated layer by layer from computer-aided design (CAD) models, tremendously reducing wastage when compared to traditional methods of manufacturing. This feature is particularly useful in the aerospace and automotive industries where lightweight designs are essential to conserve energy and reduce emissions. In addition, AM allows for the employment of greener and more bio-based materials, including mycelium composites and recycled polymers, which makes the process even more environmentally friendly. This technology also enables decentralized manufacturing, which reduces transportation emissions and builds more robust supply chains. However, there are still certain gaps that need to be addressed, such as exceptional energy use from some AM processes and the lack of adequate sustainability measures within the full product life cycle. In order to harness the full potential of the AM industry towards sustainable practices, the focus of the study presented in this chapter is to develop a novel evaluation metric to access the sustainability score of a product to be developed through additive manufacturing.
- 21 July 2026
- Published by Taylor & Francis
- p. 121-130
Sustainable Development with Additive Manufactured Materials
Additive manufacturing (AM), also referred to as 3D printing, is arguably one of the emerging technologies that has fundamentally changed the paradigm of sustainable growth. AM technology strives to achieve material efficiency by allowing complex geometries to be fabricated layer by layer from computer-aided design (CAD) models, tremendously reducing wastage when compared to traditional methods of manufacturing. This feature is particularly useful in the aerospace and automotive industries where lightweight designs are essential to conserve energy and reduce emissions. In addition, AM allows for the employment of greener and more bio-based materials, including mycelium composites and recycled polymers, which makes the process even more environmentally friendly. This technology also enables decentralized manufacturing, which reduces transportation emissions and builds more robust supply chains. However, there are still certain gaps that need to be addressed, such as exceptional energy use from some AM processes and the lack of adequate sustainability measures within the full product life cycle. In order to harness the full potential of the AM industry towards sustainable practices, the focus of the study presented in this chapter is to develop a novel evaluation metric to access the sustainability score of a product to be developed through additive manufacturing.
- Open Access
- 28 October 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 686, 126309
Numerical modelling for coupled flow, transport, pharmacokinetic and pharmacodynamic of tablet-loaded hollow microneedle patch for transdermal drug delivery
- 28 October 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 686, 126309
Open AccessNumerical modelling for coupled flow, transport, pharmacokinetic and pharmacodynamic of tablet-loaded hollow microneedle patch for transdermal drug delivery
- Open Access
- 22 July 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 682, 125989
Dynamics of insertion and extraction of hollow pyramidal microneedles: experiments and numerical modelling
- 22 July 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 682, 125989
Open AccessDynamics of insertion and extraction of hollow pyramidal microneedles: experiments and numerical modelling
- Open Access
- 24 February 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 673, 125386
Optimising distribution of hollow microneedle in arrays for transdermal drug delivery considering effects of tissue compression on drug permeability
- 24 February 2025
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 673, 125386
Open AccessOptimising distribution of hollow microneedle in arrays for transdermal drug delivery considering effects of tissue compression on drug permeability
- 4 August 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (1) , 1-32
Development of a Multilayer Iliac Crest Numerical Model for Simulating Honeybee Stinger-Inspired Hollow Needle Insertion
Minimally invasive biopsy needles are frequently inserted into the desired body regions while performing the bone marrow biopsy (BMB) procedure. The key problem with needle insertion in tissues is that the insertion force damages the tissue and deviates the needle path, leading the needle to miss the desired target and reducing biopsy sample integrity. To address these shortcomings, the present work developed a unique bio-inspired barbed biopsy needle design that reduces insertion/extraction forces and needle deflection. This study established several design parameters, including barb geometry and shape (viz., the height of barb, barbed front angle, barbed back angle, and length of portion containing barbs), and examined the impact of these factors on insertion/extraction force and deflection. A Lagrangian surface-based nonlinear finite element (FE) approach has been used to numerically simulate the BMB procedure on a three-dimensional (3D) multilayered heterogeneous model of the human iliac crest. The proposed honeybee stinger-inspired needle design has been found to reduce both insertion and extraction forces because of the decreased frictional surface of the biopsy needle.
- 4 August 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (1) , 1-32
Development of a Multilayer Iliac Crest Numerical Model for Simulating Honeybee Stinger-Inspired Hollow Needle Insertion
Minimally invasive biopsy needles are frequently inserted into the desired body regions while performing the bone marrow biopsy (BMB) procedure. The key problem with needle insertion in tissues is that the insertion force damages the tissue and deviates the needle path, leading the needle to miss the desired target and reducing biopsy sample integrity. To address these shortcomings, the present work developed a unique bio-inspired barbed biopsy needle design that reduces insertion/extraction forces and needle deflection. This study established several design parameters, including barb geometry and shape (viz., the height of barb, barbed front angle, barbed back angle, and length of portion containing barbs), and examined the impact of these factors on insertion/extraction force and deflection. A Lagrangian surface-based nonlinear finite element (FE) approach has been used to numerically simulate the BMB procedure on a three-dimensional (3D) multilayered heterogeneous model of the human iliac crest. The proposed honeybee stinger-inspired needle design has been found to reduce both insertion and extraction forces because of the decreased frictional surface of the biopsy needle.
- Open Access
- 24 June 2023
- Published by Springer Nature in European Journal of Medical Research
- Vol. 28 (1) , 1-17
A prospective survey on trephine biopsy of bone and bone marrow: an experience with 274 Indian patients’ biopsies
Trephine bone marrow biopsy is an effective technique for diagnosing hematological malignancies in patients of different ages. During trephine biopsy, bone marrow cores are obtained for detailed morphological evaluation to look for any abnormality and arrive at a diagnosis. The primary goal of this work is to perform a survey on Indian patients of various ages for the trephine bone marrow biopsy process. In the present study, data related to 274 trephine biopsy samples from 300 patients were acquired at the Post Graduate Institute of Medical Education and Research (PGIMER) in Chandigarh, India. Pain was found to be the sole major procedure-related complication, and patients reported no/less pain in 41 BMB (14.96%) patients, moderate pain in 82 (29.92%) cases, and unbearable pain in 151 (55.1%) BMB cases. In addition, the patients were evaluated by the authors and hematologist as non-anxious for the procedure in 34 (12.4%), anxious in 92 (33.57%), and very/highly anxious in 148 (56%) cases. The bone texture of the patients significantly affected the needle bending, number of repetitions required, and size of the bone marrow sample. This demonstrates the need for improvement in the biopsy procedure. To this end, a survey was conducted to assess the numerous difficulties and diagnostic outcomes throughout the trephine biopsy process.
- 24 June 2023
- Published by Springer Nature in European Journal of Medical Research
- Vol. 28 (1) , 1-17
Open AccessA prospective survey on trephine biopsy of bone and bone marrow: an experience with 274 Indian patients’ biopsies
Trephine bone marrow biopsy is an effective technique for diagnosing hematological malignancies in patients of different ages. During trephine biopsy, bone marrow cores are obtained for detailed morphological evaluation to look for any abnormality and arrive at a diagnosis. The primary goal of this work is to perform a survey on Indian patients of various ages for the trephine bone marrow biopsy process. In the present study, data related to 274 trephine biopsy samples from 300 patients were acquired at the Post Graduate Institute of Medical Education and Research (PGIMER) in Chandigarh, India. Pain was found to be the sole major procedure-related complication, and patients reported no/less pain in 41 BMB (14.96%) patients, moderate pain in 82 (29.92%) cases, and unbearable pain in 151 (55.1%) BMB cases. In addition, the patients were evaluated by the authors and hematologist as non-anxious for the procedure in 34 (12.4%), anxious in 92 (33.57%), and very/highly anxious in 148 (56%) cases. The bone texture of the patients significantly affected the needle bending, number of repetitions required, and size of the bone marrow sample. This demonstrates the need for improvement in the biopsy procedure. To this end, a survey was conducted to assess the numerous difficulties and diagnostic outcomes throughout the trephine biopsy process.
- 8 September 2022
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 6 (1)
Numerical Modeling of Conical-Shaped Bone Marrow Biopsy Needle Into Multilayer Iliac Crest Model
Bone marrow biopsy (BMB) is a standard technique used in various therapies, research, diagnosis, and prognosis. The extensive forces during biopsy result in un-necessary stress concentrations that are primarily hazardous to weak end bones. To enhance protection and to better identify the risks of bone biopsy, it is essential to understand and predict the interaction of needles with multiple layers of skin and bone. The present investigation aimed to find out the numerical evaluation of forces involved in the insertion and extraction of the needle into multilayer iliac crest model. The insertion and extraction forces have been studied at different diameters of biopsy needles up to a depth of 15.35 mm and insertion speeds in the range of 1 mm/s to 10 mm/s. The results showed that the insertion and extraction forces vary according to the needle diameter and relative velocity among the needle and tissue layers. A linear force versus depth relationship has been obtained in the preliminary phase, and as the depth of insertion increases, the forces increase nonlinearly. At the end phase of penetration, the forces augmented more rapidly at a low insertion rate compared to the high insertion rate.
- 8 September 2022
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 6 (1)
Numerical Modeling of Conical-Shaped Bone Marrow Biopsy Needle Into Multilayer Iliac Crest Model
Bone marrow biopsy (BMB) is a standard technique used in various therapies, research, diagnosis, and prognosis. The extensive forces during biopsy result in un-necessary stress concentrations that are primarily hazardous to weak end bones. To enhance protection and to better identify the risks of bone biopsy, it is essential to understand and predict the interaction of needles with multiple layers of skin and bone. The present investigation aimed to find out the numerical evaluation of forces involved in the insertion and extraction of the needle into multilayer iliac crest model. The insertion and extraction forces have been studied at different diameters of biopsy needles up to a depth of 15.35 mm and insertion speeds in the range of 1 mm/s to 10 mm/s. The results showed that the insertion and extraction forces vary according to the needle diameter and relative velocity among the needle and tissue layers. A linear force versus depth relationship has been obtained in the preliminary phase, and as the depth of insertion increases, the forces increase nonlinearly. At the end phase of penetration, the forces augmented more rapidly at a low insertion rate compared to the high insertion rate.
- 11 June 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (8) , 877-892
Finite element simulation of multilayer model to simulate fine needle insertion mechanism into iliac crest for bone marrow biopsy
The main aim of this work is to use a finite element technique (FEM) to gain understanding about the bone marrow biopsy (BMB) needle insertion process and needle-tissue interactions in the human iliac crest. A multi-layer iliac crest model consists of stratum corneum, dermis, epidermis, hypodermis, cortical, and cancellous bone has been established. This paper proposes a FE model that examines all phases of tissue deformation, including puncture, cutting, needle-tissue interaction, and various stress-strain values for BMB needle during interaction. The results explain the needle-tissue interface and show the potential of this technique to estimate bone damage and tissue deformation for multiple needle dimensions, coefficient of friction, and penetration speeds. The insertion and extraction force of conical-shaped needles in the multi-layered iliac crest model decreased by 18.92% and 37.5%, respectively, as the needle diameter reduced from 11 G to 20 G. It has also been found that the significant insertion motion raises the deformation of the tissue due to the augmented frictional forces but reduces the strain perpendicular to the penetration direction closer to the needle tip. The simulation outcomes are helpful for the optimal design of fine biopsy needles used to perform the bone marrow biopsies.
- 11 June 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (8) , 877-892
Finite element simulation of multilayer model to simulate fine needle insertion mechanism into iliac crest for bone marrow biopsy
The main aim of this work is to use a finite element technique (FEM) to gain understanding about the bone marrow biopsy (BMB) needle insertion process and needle-tissue interactions in the human iliac crest. A multi-layer iliac crest model consists of stratum corneum, dermis, epidermis, hypodermis, cortical, and cancellous bone has been established. This paper proposes a FE model that examines all phases of tissue deformation, including puncture, cutting, needle-tissue interaction, and various stress-strain values for BMB needle during interaction. The results explain the needle-tissue interface and show the potential of this technique to estimate bone damage and tissue deformation for multiple needle dimensions, coefficient of friction, and penetration speeds. The insertion and extraction force of conical-shaped needles in the multi-layered iliac crest model decreased by 18.92% and 37.5%, respectively, as the needle diameter reduced from 11 G to 20 G. It has also been found that the significant insertion motion raises the deformation of the tissue due to the augmented frictional forces but reduces the strain perpendicular to the penetration direction closer to the needle tip. The simulation outcomes are helpful for the optimal design of fine biopsy needles used to perform the bone marrow biopsies.
- 30 July 2021
- Published by Taylor & Francis in IETE Technical Review
- Vol. 39 (5) , 1011-1026
A Systematic Review of Real-time Fine-needle Aspiration Biopsy Methods for Soft Tissues
Fine needle aspiration (FNA) biopsy is a painless, consistent, less expensive, and ordinarily secure clinical technique in diagnosing cancer, lymph, nodules, and other tumors. The present study concentrates on various improvements and advances made in previous years to enhance the accuracy, sensitivity, and specificity for real-time FNA biopsy, leading to modern techniques to needle aspiration technology. A brief review of preliminary research articles on FNA biopsy is done, and the background details of FNA biopsy are examined. FNA biopsy is an effective cytological method with adequate diagnostic precision, while primarily implemented in prostate and lung cancer cases.
- 30 July 2021
- Published by Taylor & Francis in IETE Technical Review
- Vol. 39 (5) , 1011-1026
A Systematic Review of Real-time Fine-needle Aspiration Biopsy Methods for Soft Tissues
Fine needle aspiration (FNA) biopsy is a painless, consistent, less expensive, and ordinarily secure clinical technique in diagnosing cancer, lymph, nodules, and other tumors. The present study concentrates on various improvements and advances made in previous years to enhance the accuracy, sensitivity, and specificity for real-time FNA biopsy, leading to modern techniques to needle aspiration technology. A brief review of preliminary research articles on FNA biopsy is done, and the background details of FNA biopsy are examined. FNA biopsy is an effective cytological method with adequate diagnostic precision, while primarily implemented in prostate and lung cancer cases.
- 17 March 2020
- Published by SAGE Publications in Journal of Micromanufacturing
- Vol. 3 (1) , 5-12
Microfriction stir welding of AA 6061-T6 thin sheets using in-house developed fixture
The present work examines microhardness, tensile strength, and microstructure in microfriction stir welding (µ-FSW) of 0.5 mm thick AA 6061-T6 sheets. The capability of in-house developed work fixture and welding tools to attain nondamaged and continuous welds has been verified through multiple runs at different tool traverse speeds. On examination, it was found that by using the proposed work fixture, weld strength reached up to 57% as that of the base metal when performed at tool traversing speed of 150 mm min–1. The dynamic recrystallization during µ-FSW may lead to the formation of equiaxed grains in stir region and transition zone. The microstructure showed that the thermomechanically affected zone reduced with tool traversing speed.
- 17 March 2020
- Published by SAGE Publications in Journal of Micromanufacturing
- Vol. 3 (1) , 5-12
Microfriction stir welding of AA 6061-T6 thin sheets using in-house developed fixture
The present work examines microhardness, tensile strength, and microstructure in microfriction stir welding (µ-FSW) of 0.5 mm thick AA 6061-T6 sheets. The capability of in-house developed work fixture and welding tools to attain nondamaged and continuous welds has been verified through multiple runs at different tool traverse speeds. On examination, it was found that by using the proposed work fixture, weld strength reached up to 57% as that of the base metal when performed at tool traversing speed of 150 mm min–1. The dynamic recrystallization during µ-FSW may lead to the formation of equiaxed grains in stir region and transition zone. The microstructure showed that the thermomechanically affected zone reduced with tool traversing speed.