Ashish Kumar Sahani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ashish Kumar Sahani has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Bijit Basumatary
Department of Biomedical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
8 shared publications - Rahul Nadda
Chemical Engineering Department, Loughborough University, Loughborough LE11 3TU Leicestershire, the United Kingdom of Great Britain and Northern Ireland
4 shared publications - Rajat Suvra Halder
Department of Biomedical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
4 shared publications - Ravinder Kumar
Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, USA
4 shared publications - Gurpreet Singh Wander
Department of Cardiology, Dayanand Medical College and Hospital, Ludhiana, India
3 shared publications Rahul Shukla
Department of Biomedical Engineering Indian Institute of Technology Ropar Rupnagar Punjab India
3 shared publications
Latest Publications
- 23 September 2025
- Published by Wiley in Epileptic Disorders
- Vol. 27 (6) , 1227-1236
Enhancing medication adherence in drug‐resistant epilepsy using “Epilepto”: A pilot randomized controlled trial (EMPOWER‐E)
Objective: Drug‐resistant epilepsy is a disabling, chronic condition in children. Long‐term prognosis depends on the extent of seizure control. Ensuring compliance with medication can help reduce the seizure burden. Forgetfulness is a key barrier to adherence. To address this, we used a mobile application, “Epilepto,” to deliver regular medication reminders aimed at improving compliance. Method: We enrolled children with drug‐resistant epilepsy aged 3 months to 18 years with varied etiology and randomized them into two groups. The intervention group was trained to use the application to help remind them of the medications, along with the standard of care treatment given to the control group. Medication adherence was assessed using the Morisky Medication Adherence Scale‐8 (MMAS‐8), and seizure burden was assessed using the Early Childhood Epilepsy Severity Scale (E‐Chess). All the children were assessed at 3 and 6 months after enrollment. Results: A total of 100 children were randomized (1:1) to either the control or intervention group. The median age of children in the intervention group was 84 months (Interquartile range, 45–144), and the control group was 96 months (48–144). Overall, 70% of the children were boys, and 52% had generalized epilepsy. The majority of the cases had a structural (70%) or a genetic (20.6%) etiology. Most of the users found daily reminders useful (42/48). 81.2% found this an acceptable intervention at the 6‐month follow‐up. There was a gradual improvement in the MMAS‐8 scores over 6 months, with a 30% rise in high adherence in the intervention group as compared to only a 6% rise in the control group. There was no reduction in seizure burden as assessed by E‐Chess at the end of the study period. Significance: The use of medication reminders appeared to be a feasible intervention for children with drug‐resistant epilepsy to improve medication adherence.
- 23 September 2025
- Published by Wiley in Epileptic Disorders
- Vol. 27 (6) , 1227-1236
Enhancing medication adherence in drug‐resistant epilepsy using “Epilepto”: A pilot randomized controlled trial (EMPOWER‐E)
Objective: Drug‐resistant epilepsy is a disabling, chronic condition in children. Long‐term prognosis depends on the extent of seizure control. Ensuring compliance with medication can help reduce the seizure burden. Forgetfulness is a key barrier to adherence. To address this, we used a mobile application, “Epilepto,” to deliver regular medication reminders aimed at improving compliance. Method: We enrolled children with drug‐resistant epilepsy aged 3 months to 18 years with varied etiology and randomized them into two groups. The intervention group was trained to use the application to help remind them of the medications, along with the standard of care treatment given to the control group. Medication adherence was assessed using the Morisky Medication Adherence Scale‐8 (MMAS‐8), and seizure burden was assessed using the Early Childhood Epilepsy Severity Scale (E‐Chess). All the children were assessed at 3 and 6 months after enrollment. Results: A total of 100 children were randomized (1:1) to either the control or intervention group. The median age of children in the intervention group was 84 months (Interquartile range, 45–144), and the control group was 96 months (48–144). Overall, 70% of the children were boys, and 52% had generalized epilepsy. The majority of the cases had a structural (70%) or a genetic (20.6%) etiology. Most of the users found daily reminders useful (42/48). 81.2% found this an acceptable intervention at the 6‐month follow‐up. There was a gradual improvement in the MMAS‐8 scores over 6 months, with a 30% rise in high adherence in the intervention group as compared to only a 6% rise in the control group. There was no reduction in seizure burden as assessed by E‐Chess at the end of the study period. Significance: The use of medication reminders appeared to be a feasible intervention for children with drug‐resistant epilepsy to improve medication adherence.
- Open Access
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
AI-Enhanced FES for Foot Drop: A Novel Biphasic Charge-Balanced Stimulation Approach
Foot drop is a neuromuscular condition that impairs a patient’s ability to lift their foot while walking, leading to gait abnormalities and increased fall risk. Functional Electrical Stimulation (FES) is a rehabilitation technique that stimulates the peroneal nerve to restore normal movement. However, existing FES devices often lack precise charge balancing and timing accuracy, which can cause patient discomfort and potential tissue damage. To address these challenges, we developed a wearable, compact, and AI-driven FES system capable of generating biphasic, charge-balanced, trapezoidal pulses. The system integrates an ESP32 microcontroller, an OPA452-based stimulation circuit, and machine learning algorithms for foot lift detection. Unlike traditional threshold-based detection methods, our AI-enhanced approach adapts stimulation timing in real-time, improving synchronization with the patient’s gait. Initial testing demonstrated the system’s ability to generate precise charge-balanced stimulation pulses while accurately detecting foot-lift events. The AI-based detection method improved timing accuracy, reducing unwanted stimulation and enhancing patient comfort. The proposed system offers a technological advancement in neurorehabilitation, addressing key limitations of existing FES solutions. By integrating machine learning with FES, this work introduces a personalized, intelligent stimulation system that enhances rehabilitation outcomes for individuals with foot drop. The developed FES system achieved an average accuracy of 92.2%. Stimulation was found to be smooth between 120-220 microseconds and 25-35 Hz.
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Open AccessAI-Enhanced FES for Foot Drop: A Novel Biphasic Charge-Balanced Stimulation Approach
Foot drop is a neuromuscular condition that impairs a patient’s ability to lift their foot while walking, leading to gait abnormalities and increased fall risk. Functional Electrical Stimulation (FES) is a rehabilitation technique that stimulates the peroneal nerve to restore normal movement. However, existing FES devices often lack precise charge balancing and timing accuracy, which can cause patient discomfort and potential tissue damage. To address these challenges, we developed a wearable, compact, and AI-driven FES system capable of generating biphasic, charge-balanced, trapezoidal pulses. The system integrates an ESP32 microcontroller, an OPA452-based stimulation circuit, and machine learning algorithms for foot lift detection. Unlike traditional threshold-based detection methods, our AI-enhanced approach adapts stimulation timing in real-time, improving synchronization with the patient’s gait. Initial testing demonstrated the system’s ability to generate precise charge-balanced stimulation pulses while accurately detecting foot-lift events. The AI-based detection method improved timing accuracy, reducing unwanted stimulation and enhancing patient comfort. The proposed system offers a technological advancement in neurorehabilitation, addressing key limitations of existing FES solutions. By integrating machine learning with FES, this work introduces a personalized, intelligent stimulation system that enhances rehabilitation outcomes for individuals with foot drop. The developed FES system achieved an average accuracy of 92.2%. Stimulation was found to be smooth between 120-220 microseconds and 25-35 Hz.
- 6 August 2025
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 84 (40) , 48283-48307
Towards an RGB camera-based rehabilitation exercise assessment using an enhanced spatio-temporal transformer framework
- 6 August 2025
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 84 (40) , 48283-48307
Towards an RGB camera-based rehabilitation exercise assessment using an enhanced spatio-temporal transformer framework
- 7 April 2025
- Published by ASME International in Journal of Medical Devices
- Vol. 19 (2) , 1-9
Optimizing Coronary Artery Bypass Grafting Parameters for Failure Prevention Using Computational Fluid Dynamics
Coronary artery bypass grafting (CABG) is a surgical procedure aimed at improving blood circulation to the heart muscle in individuals with having coronary artery disease. This involves transplanting a healthy artery from elsewhere in the body to bypass a blocked coronary artery. In this study, computational fluid dynamics (CFD) simulations were performed using ansysfluent software to examine the impact of CABG on partially blocked coronary arteries. This analysis considered laminar flow conditions with the application of the no-slip boundary condition and took into account the Reynolds number parameter, considering momentum and transport properties within the specified geometric, material, and physical constraints of blockage. This paper aims to mitigate coronary artery failure by optimizing surgical techniques and leveraging insights from failure studies. Here, the chosen model contributes to establishing optimal surgical protocols for CABG, ensuring the long-term patency of the graft. Through CFD analysis, blood flow dynamics in the artery postgrafting have been evaluated for varied parameters such as blockage size and position, constituting the optimization study. Through this study, optimal outcomes are achieved when the graft is positioned appropriately to maintain laminar flow conditions within the artery. The graft should be positioned with an accurate assessment of blockage size and shape to minimize the risk of heart failure due to reduced flow velocity and wall shear stress.
- 7 April 2025
- Published by ASME International in Journal of Medical Devices
- Vol. 19 (2) , 1-9
Optimizing Coronary Artery Bypass Grafting Parameters for Failure Prevention Using Computational Fluid Dynamics
Coronary artery bypass grafting (CABG) is a surgical procedure aimed at improving blood circulation to the heart muscle in individuals with having coronary artery disease. This involves transplanting a healthy artery from elsewhere in the body to bypass a blocked coronary artery. In this study, computational fluid dynamics (CFD) simulations were performed using ansysfluent software to examine the impact of CABG on partially blocked coronary arteries. This analysis considered laminar flow conditions with the application of the no-slip boundary condition and took into account the Reynolds number parameter, considering momentum and transport properties within the specified geometric, material, and physical constraints of blockage. This paper aims to mitigate coronary artery failure by optimizing surgical techniques and leveraging insights from failure studies. Here, the chosen model contributes to establishing optimal surgical protocols for CABG, ensuring the long-term patency of the graft. Through CFD analysis, blood flow dynamics in the artery postgrafting have been evaluated for varied parameters such as blockage size and position, constituting the optimization study. Through this study, optimal outcomes are achieved when the graft is positioned appropriately to maintain laminar flow conditions within the artery. The graft should be positioned with an accurate assessment of blockage size and shape to minimize the risk of heart failure due to reduced flow velocity and wall shear stress.
- 4 March 2025
- Published by Taylor & Francis in IETE Technical Review
- Vol. 42 (2) , 294-304
Epilepto: An Epilepsy Self-Management App
- 4 March 2025
- Published by Taylor & Francis in IETE Technical Review
- Vol. 42 (2) , 294-304
Epilepto: An Epilepsy Self-Management App
- 2 May 2024
- Published by Taylor & Francis in IETE Technical Review
- Vol. 41 (6) , 683-694
Deep Learning Approach for Gait Detection for Precise Stimulation of FES to Correct Foot Drop
- 2 May 2024
- Published by Taylor & Francis in IETE Technical Review
- Vol. 41 (6) , 683-694
Deep Learning Approach for Gait Detection for Precise Stimulation of FES to Correct Foot Drop
- Open Access
- 4 January 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (2) , 025002
Development of a low-cost, compact, wireless, 16 - channel biopotential data acquisition, signal conditioning and arbitrary waveform stimulator
The health and fitness of the human body rely heavily on physiological parameters. These parameters can be measured using various tools such as ECG, EMG, EEG, EOG, among others, to obtain real-time physiological data. Analysing the bio-signals obtained from these measurements can provide valuable information that can be used to improve health-care in terms of observation, diagnosis, and treatment. In bio-signal pattern recognition applications, more channels provide multiple information simultaneously. Different biosignal acquisition devices are available in the market, most of which are designed for specific signals like ECG, EMG, EEG etc The gain of the amplifiers and frequency of the filters are designed as per the targeted signals; due to which one device cannot be used for other signals. Also, most of the systems are wired system which is not comfortable for animal studies. In this paper, a low-cost, compact, wireless, 16 channel biopotential data acquisition system with integrated electrical stimulator is designed and implemented. There are several novel and flexible design approaches were incorporated in the proposed design like (1) It has user selectable digital filter in each channel based on the signal frequencies like ECG, EMG, EEG, EOG. The same system will be used to acquire different signals simultaneously. (2) It has variable gain with a configurable analog bandpass filter. (3) It can acquire signals from 4 patients simultaneously. (4) The system is capable to acquire signal from both two-electrode as well as three-electrode configurations. (5) It has integrated stimulator with trapezoidal, charge-balanced, biphasic stimulus output with near zero DC level and user selectable pulse duration or frequency of the stimulus. The developed system has the ability to acquire and transmit data wirelessly in real-time at a high transfer rate. To validate the performance of the system, tests were conducted on the acquired signals using a simulator.
- 4 January 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (2) , 025002
Open AccessDevelopment of a low-cost, compact, wireless, 16 - channel biopotential data acquisition, signal conditioning and arbitrary waveform stimulator
The health and fitness of the human body rely heavily on physiological parameters. These parameters can be measured using various tools such as ECG, EMG, EEG, EOG, among others, to obtain real-time physiological data. Analysing the bio-signals obtained from these measurements can provide valuable information that can be used to improve health-care in terms of observation, diagnosis, and treatment. In bio-signal pattern recognition applications, more channels provide multiple information simultaneously. Different biosignal acquisition devices are available in the market, most of which are designed for specific signals like ECG, EMG, EEG etc The gain of the amplifiers and frequency of the filters are designed as per the targeted signals; due to which one device cannot be used for other signals. Also, most of the systems are wired system which is not comfortable for animal studies. In this paper, a low-cost, compact, wireless, 16 channel biopotential data acquisition system with integrated electrical stimulator is designed and implemented. There are several novel and flexible design approaches were incorporated in the proposed design like (1) It has user selectable digital filter in each channel based on the signal frequencies like ECG, EMG, EEG, EOG. The same system will be used to acquire different signals simultaneously. (2) It has variable gain with a configurable analog bandpass filter. (3) It can acquire signals from 4 patients simultaneously. (4) The system is capable to acquire signal from both two-electrode as well as three-electrode configurations. (5) It has integrated stimulator with trapezoidal, charge-balanced, biphasic stimulus output with near zero DC level and user selectable pulse duration or frequency of the stimulus. The developed system has the ability to acquire and transmit data wirelessly in real-time at a high transfer rate. To validate the performance of the system, tests were conducted on the acquired signals using a simulator.
- 12 December 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (7) , 6370-6381
AMLEX – A Smart Patient Driven Oxygen Rationing Device
- 12 December 2023
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (7) , 6370-6381
AMLEX – A Smart Patient Driven Oxygen Rationing Device
- 10 August 2023
- Published by Taylor & Francis in IETE Technical Review
- Vol. 41 (3) , 274-286
A Deep Learning-based System for Detecting Anemia from Eye Conjunctiva Images taken from a Smartphone
- 10 August 2023
- Published by Taylor & Francis in IETE Technical Review
- Vol. 41 (3) , 274-286
A Deep Learning-based System for Detecting Anemia from Eye Conjunctiva Images taken from a Smartphone
- 4 August 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (1) , 1-32
Development of a Multilayer Iliac Crest Numerical Model for Simulating Honeybee Stinger-Inspired Hollow Needle Insertion
Minimally invasive biopsy needles are frequently inserted into the desired body regions while performing the bone marrow biopsy (BMB) procedure. The key problem with needle insertion in tissues is that the insertion force damages the tissue and deviates the needle path, leading the needle to miss the desired target and reducing biopsy sample integrity. To address these shortcomings, the present work developed a unique bio-inspired barbed biopsy needle design that reduces insertion/extraction forces and needle deflection. This study established several design parameters, including barb geometry and shape (viz., the height of barb, barbed front angle, barbed back angle, and length of portion containing barbs), and examined the impact of these factors on insertion/extraction force and deflection. A Lagrangian surface-based nonlinear finite element (FE) approach has been used to numerically simulate the BMB procedure on a three-dimensional (3D) multilayered heterogeneous model of the human iliac crest. The proposed honeybee stinger-inspired needle design has been found to reduce both insertion and extraction forces because of the decreased frictional surface of the biopsy needle.
- 4 August 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (1) , 1-32
Development of a Multilayer Iliac Crest Numerical Model for Simulating Honeybee Stinger-Inspired Hollow Needle Insertion
Minimally invasive biopsy needles are frequently inserted into the desired body regions while performing the bone marrow biopsy (BMB) procedure. The key problem with needle insertion in tissues is that the insertion force damages the tissue and deviates the needle path, leading the needle to miss the desired target and reducing biopsy sample integrity. To address these shortcomings, the present work developed a unique bio-inspired barbed biopsy needle design that reduces insertion/extraction forces and needle deflection. This study established several design parameters, including barb geometry and shape (viz., the height of barb, barbed front angle, barbed back angle, and length of portion containing barbs), and examined the impact of these factors on insertion/extraction force and deflection. A Lagrangian surface-based nonlinear finite element (FE) approach has been used to numerically simulate the BMB procedure on a three-dimensional (3D) multilayered heterogeneous model of the human iliac crest. The proposed honeybee stinger-inspired needle design has been found to reduce both insertion and extraction forces because of the decreased frictional surface of the biopsy needle.