CPChatumal Perera

Chatumal Perera

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chatumal Perera has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sequential Mutual-Inductance Identification Method for Wireless Power Transfer Systems of Electric Vehicles

    by Shuang Nie, Wei Han, Zhichao Luo, Chatumal Perera, Peter W. Lehn

    In a multi-transmitter static wireless power transfer (WPT) system for electric vehicles (EV), the transmitter-to-receiver mutual-inductance value is required to assign current to each transmitter. This article proposes a sequential mutual-inductance identification method (SMIM) that identifies the transmitter-receiver mutual inductance transmitter by transmitter in sequence. The proposed method simplifies the multi-transmitter system into a single-transmitter system through the current blocking principle. The identification only requires measuring the magnitude of DC bus voltage and transmitter rms currents where no receiver-side sensor is needed. The mutual-inductance can be obtained through simple calculations with low computation requirements. It is demonstrated that SMIM robustness against transmitter self-inductance deviation is greatly enhanced by introducing a two-point identification technique. High SMIM accuracy is achieved by optimizing test conditions over the entire viable charging zone of WPT system. The experimental results demonstrate a maximum 3.11% error in identified mutual-inductance, provided coupling coefficient exceeds 0.02.


  • Maximum Torque Operation of Open-Winding Induction Motor Dual Drives Using a Floating Capacitor Bridge in the Field Weakening Region

    by Saeed Wdaan, Chatumal Perera, John Salmon

    A field weakening controller is presented that extends the speed range of a dual inverter drive using a floating capacitor bridge. The controller utilizes the stator current reference frame to decouple the motor demand into active and reactive components. This is used so that the main bridge supplies the real power and the floating bridge supplies the reactive power until the floating bridge reaches its maximum voltage. The main bridge is then used to supply some of the reactive demand, which in turn adds additional voltage boost that is used to extend the drive’s constant power region, improve the motor speed acceleration performance, output power, and torque. It is found that the presented controller can increase the drive speed extension ratio to 9.2 times the base speed compared to 5 when always operating the main bridge at unity power factor. The motor maximum fundamental voltage is 1.82 p.u when compared to that of a single inverter drive. This controller performance is demonstrated experimentally using both transient and steady-state analysis. The controller is also compared with other two field weakening controllers using the same regulator tunings and experimental setup.


  • Open Access

    Multiport Converter With Enhanced Port Utilization Using Multitasking Dual Inverters

    by Chatumal Perera, John Salmon, Gregory J. Kish

    With the development of renewable energy and electric vehicle technologies, a need for multiport DC/DC/AC converters with high power density and reliability has arisen. A dual inverter based bidirectional multiport converter with two dissimilar voltage DC ports and an AC port is presented. The converter is capable of processing up to 1.67, 1.41, and 1 p.u. of power through its main DC, auxiliary DC and AC ports respectively, while only using the semiconductor and magnetics effort of a DC/AC converter rated for 1 p.u. Analysis reveals that this is more than thrice and twice the power limits of the main and auxiliary DC ports respectively, compared to using two independent inverters with a three-winding transformer. Furthermore, the proposed converter is more efficient than the latter option. These benefits are due to the multitasking of inverters and the existence of single stage DC/DC and DC/AC power transfer mechanisms enabled by the use of a center tapped transformer. A control strategy using these two mechanisms, capable of independently controlling the power flows between ports is also presented. Independent inverter control is also possible, allowing power flow between the main DC and AC ports during the failure of a single inverter. These claims are verified through thorough analysis, extensive simulation and experimental results using a 3 kW prototype.


  • Open Access

    Exploiting buck–boost duality in dual active bridge modular multilevel converters to achieve high DC step ratios

    by Sunny Kung, Dalu Liu, Chatumal Perera, Moosa Moghimi Haji, John Salmon, Gregory Kish

    A previously unidentified duality between buck and boost configured dc‐ac modular multilevel converters (MMCs) is firstly revealed. Armed with this insight, a new dual‐active‐bridge (DAB)‐MMC is proposed for high‐voltage dc (HVDC)‐to‐medium‐voltage dc (MVDC) power conversion that utilizes cascaded buck and boost dc–ac stages to obtain high dc step ratios. Single‐phase and three‐phase variants are presented. When compared with the conventional DAB‐MMC solution for the same dc step ratio, both the single‐phase and three‐phase topologies offer reduced MVDC side transformer winding current stresses, while the three‐phase topology also yields reduced MVDC side MMC submodule current stresses. The former is achieved by having the freedom to design the transformer with a lower turns ratio, and the latter is achieved due to the inherent paralleling of submodules on the MVDC side of the converter. Analysis of the three‐phase topology reveals its low‐voltage side transformer winding current stresses can be reduced by a factor of 3.27. A generalized mathematical model of the proposed buck–boost DAB‐MMC is derived and used to propose a dynamic controller for both the single‐phase and three‐phase topologies. Real‐time simulations obtained from a real‐time digital simulator system that incorporates an FPGA‐based controller for the valve firing controls validate the proposed buck–boost DAB‐MMC operation and dynamic controls.


  • Multiport Converter With Independent Control of AC and DC Power Flows for Bipolar DC Distribution

    by Chatumal Perera, John Salmon, Gregory J. Kish

    A multiport AC-DC converter topology is proposed that offers bidirectional power transfer capability between the two DC ports and the AC port. The decoupling of power flows can be exploited as a pole voltage balancing mechanism to accommodate unbalanced DC side loads in bipolar DC distribution systems. The proposed topology gains bipolar operation by using two three-phase two-level voltage-sourced converters connected in a differential fashion with a center-tapped transformer. Analysis shows that no penalties are incurred in terms of increased power ratings for either the grid interface transformer or the semiconductors; only access to the center point of the converter side winding is required. A control scheme for the topology is proposed with the ability to independently control power flows between the different ports. Both the topology and control scheme are validated by extensive simulations and experiments.


  • Open Access

    Decoupled Floating Capacitor Voltage Control of a Dual Inverter Drive for an Open-Ended Winding Induction Motor

    by Chatumal Perera, Gregory J. Kish, John Salmon

    A control scheme is presented for a dual inverter drive with a floating capacitor bridge, with decoupled motor and capacitor dynamics. A stator current reference frame is used that decouples the real and reactive power components of the motor and enables the decoupling of the motor and capacitor dynamics. Apart from the high frequency voltage ripple due to the inverter switching pattern, the capacitor voltage can be kept constant even during large step changes in motor speed reference and load torque. This allows for the use of a significantly smaller floating bridge capacitor whose size depends only on the steady state high frequency voltage ripple. Additionally, the number of PI regulators used compared to previous works and the DC-link voltage requirements are both reduced.