Gregory J. Kish
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gregory J. Kish has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Anjana Wijesekera
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada
6 shared publications - John Salmon
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Canada
6 shared publications - Yuan Li
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada
6 shared publications - Yunwei Li
University of Alberta
6 shared publications - Haoran Wang
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada
5 shared publications - Chatumal Perera
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada
4 shared publications
Latest Publications
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
An Improved Fault Diagnosis and Fault Tolerant Control Strategy for Modular Multilevel Converters with Switch Open-Circuit Faults
The presence of a large number of switches in modular multilevel converters (MMCs) is a cause of significant reliability issues. To improve the reliability of MMCs, this paper presents the design and implementation of a comprehensive fault-tolerant (FT) strategy, which consists of a fault detection and localization (FDL) scheme and a fault accommodation control, to allow continued operation of the MMC under several different open-circuit faults. The fault detection mechanism involves using features defined on the arm inductors, particularly, the faulty arm is identified by utilizing an error signal between the sum of upper and lower arm capacitor voltages. Then, the faulty submodule is isolated by using the switching signals generated from the capacitors’ voltage sorting algorithm. Finally, a novel fault accommodation scheme is proposed which employs an indirect finite control set model predictive controller (FCS-MPC) to balance the energies in the arms and minimize the effect of the faults. The fault-tolerant capability is integrated with the normal operation of the MMC, thereby eliminating the need to change the control structure after the FDL. Extensive simulations and experimental results validate the effectiveness of the proposed scheme.
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
An Improved Fault Diagnosis and Fault Tolerant Control Strategy for Modular Multilevel Converters with Switch Open-Circuit Faults
The presence of a large number of switches in modular multilevel converters (MMCs) is a cause of significant reliability issues. To improve the reliability of MMCs, this paper presents the design and implementation of a comprehensive fault-tolerant (FT) strategy, which consists of a fault detection and localization (FDL) scheme and a fault accommodation control, to allow continued operation of the MMC under several different open-circuit faults. The fault detection mechanism involves using features defined on the arm inductors, particularly, the faulty arm is identified by utilizing an error signal between the sum of upper and lower arm capacitor voltages. Then, the faulty submodule is isolated by using the switching signals generated from the capacitors’ voltage sorting algorithm. Finally, a novel fault accommodation scheme is proposed which employs an indirect finite control set model predictive controller (FCS-MPC) to balance the energies in the arms and minimize the effect of the faults. The fault-tolerant capability is integrated with the normal operation of the MMC, thereby eliminating the need to change the control structure after the FDL. Extensive simulations and experimental results validate the effectiveness of the proposed scheme.
- Open Access
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1021-1036
Detailed Analysis of FDPWM1 Scheme With Trapezoidal High-Frequency Currents for Isolated Single-Stage AC-DC Converters
Isolated ac-dc topologies based on the dual parallel voltage-sourced converters (DP-VSCs) arrangement are well suited for single-stage power processing. This work focuses on a family of DP-VSC based single-stage ac-dc converters that deliberately multitask a high-frequency transformer (HFT) such that the primary side windings carry both low and high frequency (HF) currents. The low frequency components correspond to the ac grid currents that do not generate any core flux while the HF currents are exploited for power transfer via transformer action. Quasi-square HF differential voltages can be synthesized across the primary HFT windings to yield HF trapezoidal currents, all the time guaranteeing zero common-mode winding voltages. Recently, the authors proposed a discontinuous pulse-width modulation scheme, termed FDPWM1, that satisfies all these objectives to allow use of a compact 3-limb HFT in comparison to prior art that relied on collectively bulkier three single-phase HFT units. Building upon our previous work that introduced FDPWM1, this article presents an in-depth analysis of its performance characteristics across a broad range of operating points. The key contributions of this work include a comprehensive analysis of HF voltage waveform variations, HF trapezoidal currents waveform generation, HF power transfer mechanism, and soft-switching capabilities for isolated ac-dc applications. Results are experimentally validated using a 250 Vdc, 121 Vac, 0.75 kW prototype with 40 kHz HFT.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1021-1036
Open AccessDetailed Analysis of FDPWM1 Scheme With Trapezoidal High-Frequency Currents for Isolated Single-Stage AC-DC Converters
Isolated ac-dc topologies based on the dual parallel voltage-sourced converters (DP-VSCs) arrangement are well suited for single-stage power processing. This work focuses on a family of DP-VSC based single-stage ac-dc converters that deliberately multitask a high-frequency transformer (HFT) such that the primary side windings carry both low and high frequency (HF) currents. The low frequency components correspond to the ac grid currents that do not generate any core flux while the HF currents are exploited for power transfer via transformer action. Quasi-square HF differential voltages can be synthesized across the primary HFT windings to yield HF trapezoidal currents, all the time guaranteeing zero common-mode winding voltages. Recently, the authors proposed a discontinuous pulse-width modulation scheme, termed FDPWM1, that satisfies all these objectives to allow use of a compact 3-limb HFT in comparison to prior art that relied on collectively bulkier three single-phase HFT units. Building upon our previous work that introduced FDPWM1, this article presents an in-depth analysis of its performance characteristics across a broad range of operating points. The key contributions of this work include a comprehensive analysis of HF voltage waveform variations, HF trapezoidal currents waveform generation, HF power transfer mechanism, and soft-switching capabilities for isolated ac-dc applications. Results are experimentally validated using a 250 Vdc, 121 Vac, 0.75 kW prototype with 40 kHz HFT.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 3101-3118
Modeling and Steady-State Analysis of the M2AC Using Dynamic Phasors
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 3101-3118
Open AccessModeling and Steady-State Analysis of the M2AC Using Dynamic Phasors
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 409-424
Circulating Current Control for 3-Phase Parallel-Connected Dual VSCs Using DPWM With Dynamic Phase-Shifting
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 409-424
Open AccessCirculating Current Control for 3-Phase Parallel-Connected Dual VSCs Using DPWM With Dynamic Phase-Shifting
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 12 (4) , 156-157
2025 IEEE NCS PELS Chapter Highlights
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 12 (4) , 156-157
2025 IEEE NCS PELS Chapter Highlights
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3594-3607
Analysis and Mitigation of Neutral Line Current Ripple in a Dual 3L-NPC Converter System for Bipolar DC Distribution
Bipolar dc distribution systems based on a three-level neutral point clamped (3L-NPC) converter typically require a voltage balancer (VB) to achieve full bipolar dc voltage balancing. Recent studies have shown that certain grid transformer configurations allow the full control of dc-side pole power flows by multitasking the converter-side windings to carry the required dc balancing current through a dedicated neutral line (NL). NL-based NPC converter systems offer a simpler and more cost-effective alternative to VB-based systems, but suffer from significant NL current ripple caused by the pulsewidth modulation (PWM) switching of the converter. This article addresses the issue on two fronts. First, an in-depth analysis of the NL current ripple is conducted in a dual NPC converter system. Analytical expressions are derived to characterize the harmonic distribution under both phase disposition (PD) and alternate phase opposition disposition (APOD) PWM strategies. Second, based on the analysis, an improved PD-PWM strategy incorporating triple degrees-of-freedom (PD-TDoF) is proposed for dual NPC converters, effectively reducing current ripple and significantly enhancing NL current performance compared to conventional PD-PWM. The theoretical analysis and effectiveness of the proposed PD-TDoF strategy are validated through laboratory experiments.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (3) , 3594-3607
Analysis and Mitigation of Neutral Line Current Ripple in a Dual 3L-NPC Converter System for Bipolar DC Distribution
Bipolar dc distribution systems based on a three-level neutral point clamped (3L-NPC) converter typically require a voltage balancer (VB) to achieve full bipolar dc voltage balancing. Recent studies have shown that certain grid transformer configurations allow the full control of dc-side pole power flows by multitasking the converter-side windings to carry the required dc balancing current through a dedicated neutral line (NL). NL-based NPC converter systems offer a simpler and more cost-effective alternative to VB-based systems, but suffer from significant NL current ripple caused by the pulsewidth modulation (PWM) switching of the converter. This article addresses the issue on two fronts. First, an in-depth analysis of the NL current ripple is conducted in a dual NPC converter system. Analytical expressions are derived to characterize the harmonic distribution under both phase disposition (PD) and alternate phase opposition disposition (APOD) PWM strategies. Second, based on the analysis, an improved PD-PWM strategy incorporating triple degrees-of-freedom (PD-TDoF) is proposed for dual NPC converters, effectively reducing current ripple and significantly enhancing NL current performance compared to conventional PD-PWM. The theoretical analysis and effectiveness of the proposed PD-TDoF strategy are validated through laboratory experiments.
- Open Access
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 6, 1269-1281
Improved Operational Flexibility of the M2AC for Direct AC/AC Conversion
The modular multilevel ac/ac converter (M2AC) is a recently proposed partial power processing topology for direct ac/ac conversion that can adjust voltage magnitudes and phase angles in single-frequency ac power systems, analogous to a power electronic autotransformer. However, prior studies have been limited to investigating only active power transfers and basic operating features. This article addresses this gap by proposing three operating flexibility enhancements for the M2AC: 1) accommodating practical power flow scenarios where independent control of active and reactive powers is needed, 2) eliminating large dc-link capacitors to realize a fully modular and scalable architecture, and 3) incorporating full fault blocking akin to ac circuit breaker functionality. The fundamental operating principles and fault-blocking characteristics are thoroughly studied for different M2AC design variants, and a comparative analysis is conducted to quantify potential semiconductor savings in comparison to the back-to-back modular multilevel converter as a benchmark. Converter controls incorporating active and reactive power flow management and internal capacitor voltage cell balancing are developed. The M2AC's steady-state and transient operation and fault-blocking capabilities are validated through simulation studies and further confirmed by experimental tests using a laboratory-scale 250 Vpk, 1 kVA prototype.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 6, 1269-1281
Open AccessImproved Operational Flexibility of the M2AC for Direct AC/AC Conversion
The modular multilevel ac/ac converter (M2AC) is a recently proposed partial power processing topology for direct ac/ac conversion that can adjust voltage magnitudes and phase angles in single-frequency ac power systems, analogous to a power electronic autotransformer. However, prior studies have been limited to investigating only active power transfers and basic operating features. This article addresses this gap by proposing three operating flexibility enhancements for the M2AC: 1) accommodating practical power flow scenarios where independent control of active and reactive powers is needed, 2) eliminating large dc-link capacitors to realize a fully modular and scalable architecture, and 3) incorporating full fault blocking akin to ac circuit breaker functionality. The fundamental operating principles and fault-blocking characteristics are thoroughly studied for different M2AC design variants, and a comparative analysis is conducted to quantify potential semiconductor savings in comparison to the back-to-back modular multilevel converter as a benchmark. Converter controls incorporating active and reactive power flow management and internal capacitor voltage cell balancing are developed. The M2AC's steady-state and transient operation and fault-blocking capabilities are validated through simulation studies and further confirmed by experimental tests using a laboratory-scale 250 Vpk, 1 kVA prototype.
- 11 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 17160-17171
A Simplified Time-Domain Model-Based Maximum Efficiency Tracking-Aided Synchronous Rectification Strategy for CLLC Chargers
Synchronous rectification (SR), achieved by replacing secondary-side diodes with active mosfet channels, is crucial for reducing conduction losses in CLLC converters. Traditional SR methods, however, either entail costly and bulky hardware or rely on complex mathematical models. This article introduces a simplified time-domain model (STDM) that utilizes mathematical principles and detailed operational assumptions to provide initial duty cycles and gate signal phases for SR under various frequencies and load conditions. However, the STDM’s overall accuracy is compromised by parasitic parameters and parameter tolerance of the resonant tank. Directly employing the STDM-based SR method may lead to hard-switching of mosfets or increased circulating current, reducing system efficiency. To mitigate this issue, a maximum efficiency tracking (MET)-aided SR signal adjustment method is proposed, which further modifies the duty cycle and phase shift to minimize the current passing through the diodes. This STDM-MET-SR approach does not necessitate high-bandwidth sensors or complex control algorithms while offering immunity to parasitic parameters and system parameter variations. Experimental results demonstrate that the STDM-MET generated SR signals contain negligible errors compared to the required SR signals, and the efficiency of the CLLC converter with STDM-MET-SR implemented is significantly improved compared to those of diode rectification. Overall, the proposed STDM-MET-SR approach offers a cost-effective and efficient solution to reduce conduction losses in CLLC converters.
- 11 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 17160-17171
A Simplified Time-Domain Model-Based Maximum Efficiency Tracking-Aided Synchronous Rectification Strategy for CLLC Chargers
Synchronous rectification (SR), achieved by replacing secondary-side diodes with active mosfet channels, is crucial for reducing conduction losses in CLLC converters. Traditional SR methods, however, either entail costly and bulky hardware or rely on complex mathematical models. This article introduces a simplified time-domain model (STDM) that utilizes mathematical principles and detailed operational assumptions to provide initial duty cycles and gate signal phases for SR under various frequencies and load conditions. However, the STDM’s overall accuracy is compromised by parasitic parameters and parameter tolerance of the resonant tank. Directly employing the STDM-based SR method may lead to hard-switching of mosfets or increased circulating current, reducing system efficiency. To mitigate this issue, a maximum efficiency tracking (MET)-aided SR signal adjustment method is proposed, which further modifies the duty cycle and phase shift to minimize the current passing through the diodes. This STDM-MET-SR approach does not necessitate high-bandwidth sensors or complex control algorithms while offering immunity to parasitic parameters and system parameter variations. Experimental results demonstrate that the STDM-MET generated SR signals contain negligible errors compared to the required SR signals, and the efficiency of the CLLC converter with STDM-MET-SR implemented is significantly improved compared to those of diode rectification. Overall, the proposed STDM-MET-SR approach offers a cost-effective and efficient solution to reduce conduction losses in CLLC converters.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (5) , 6470-6475
A Zero Net Flux Modulation Scheme for 3-Leg Core Transformer Based 3-Phase AC–DC Topologies
Existing single-stage 3-phase AC-DC isolated topologies typically use three separate C-core high-frequency transformers (HFTs), which require significant space and reduce power density. A key challenge preventing the use of a more compact 3-leg core HFT is the lack of suitable modulation schemes, as current methods do not ensure a zero net flux condition considering all 3 legs. Violating this condition can lead to stray fluxes that induce common mode (CM) currents and high peak magnetizing currents, resulting in increased electromagnetic interferences and losses. This article proposes a new modulation scheme that, by strategic alignment of switching pulses for a dual inverter setup, both avoids CM winding voltage generation and preserves the shape of transformer secondary-side voltage waveforms for power transfer at twice the carrier frequency. These features allow the use of a single compact 3-leg core HFT. The scheme also offers: i) high-quality 3/5-level AC pulse-width modulated grid voltages, ii) a 3-level high-frequency voltage for the power transmitted via transformer action, iii) higher overall average winding volt-seconds compared to dual active bridge converters at low modulation indices, and iv) reduced switching losses due to the discontinuous nature of the scheme. Adopting a 3-leg core can cut the size of 3 C-core designs by 35-40% while achieving 4% total current harmonic distortion at full load. The presented modulation scheme is verified using both simulation and experimental results for a 250 V$_{{dc}}$, 122V$_{ac}$, 750W prototype.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (5) , 6470-6475
A Zero Net Flux Modulation Scheme for 3-Leg Core Transformer Based 3-Phase AC–DC Topologies
Existing single-stage 3-phase AC-DC isolated topologies typically use three separate C-core high-frequency transformers (HFTs), which require significant space and reduce power density. A key challenge preventing the use of a more compact 3-leg core HFT is the lack of suitable modulation schemes, as current methods do not ensure a zero net flux condition considering all 3 legs. Violating this condition can lead to stray fluxes that induce common mode (CM) currents and high peak magnetizing currents, resulting in increased electromagnetic interferences and losses. This article proposes a new modulation scheme that, by strategic alignment of switching pulses for a dual inverter setup, both avoids CM winding voltage generation and preserves the shape of transformer secondary-side voltage waveforms for power transfer at twice the carrier frequency. These features allow the use of a single compact 3-leg core HFT. The scheme also offers: i) high-quality 3/5-level AC pulse-width modulated grid voltages, ii) a 3-level high-frequency voltage for the power transmitted via transformer action, iii) higher overall average winding volt-seconds compared to dual active bridge converters at low modulation indices, and iv) reduced switching losses due to the discontinuous nature of the scheme. Adopting a 3-leg core can cut the size of 3 C-core designs by 35-40% while achieving 4% total current harmonic distortion at full load. The presented modulation scheme is verified using both simulation and experimental results for a 250 V$_{{dc}}$, 122V$_{ac}$, 750W prototype.