Christopher A. Delianides
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christopher A. Delianides has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Pedram Mohseni
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
4 shared publications - Michael A. Suster
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
3 shared publications - Akshay A. Patwardhan
Aflac Cancer and Blood Disorders Center, Children’s Healthcare of Atlanta, Department of Pediatrics, Emory University School of Medicine, Atlanta, GA
2 shared publications - Sina Pourang
Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, USA
2 shared publications - Vivien A. Sheehan
Department of Pediatrics, Emory University School of Medicine, Atlanta GA 30322, USA
2 shared publications Zoe Sekyonda
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH
2 shared publications
Latest Publications
- Open Access
- 4 August 2025
- Published by American Society of Hematology in Blood Advances
- Vol. 9 (15) , 4004-4015
Use of the microfluidic impedance red cell assay in sickle cell disease
In sickle cell disease (SCD), red blood cells (RBCs) are poorly deformable, even under normoxia (NOI). With deoxygenation, deformability of sickle RBCs is further reduced due to polymerization of hemoglobin S (HbS). Rigid, poorly deformable sickle RBCs block microvasculature, causing ischemia, pain, and organ damage. The microfluidic impedance red cell assay (MIRCA) can mechanically measure RBC deformability, providing occlusion index under NOI or hypoxia (HOI) as readouts. We analyzed RBCs from 68 adult and 34 pediatric patients with SCD using the MIRCA. Higher HOI and NOI values were positively associated with markers of inflammation, hemolysis, RBC density, older age, and severe SCD genotypes (homozygous HbSS or HbS β0-thalassemia. Each 1% higher NOI across individuals was associated with a 6.3% higher incidence of acute complications per year. Individuals with chronic complications in the past year had a 3.1% higher median NOI than those without chronic complications. Individuals on chronic transfusion therapy exhibit a subpopulation of poorly deformable RBCs captured by the MIRCA but not by a commercially available device that also measures RBC deformability, the laser assisted optical rotational cell analyzer (LoRRca). In vitro addition of voxelotor or osivelotor to samples from individuals on chronic transfusion therapy improved the deformability of these endogenous RBCs. Longitudinally collected NOI and HOI values in individuals with HbSS were stable, with a median percent point change of 13.3% and 15.7%, respectively. MIRCA can be used in combination with clinical laboratory tests to monitor RBC deformability as a biomarker of clinical status at routine clinic visits and included in clinical trials of disease-modifying agents.
- 4 August 2025
- Published by American Society of Hematology in Blood Advances
- Vol. 9 (15) , 4004-4015
Open AccessUse of the microfluidic impedance red cell assay in sickle cell disease
In sickle cell disease (SCD), red blood cells (RBCs) are poorly deformable, even under normoxia (NOI). With deoxygenation, deformability of sickle RBCs is further reduced due to polymerization of hemoglobin S (HbS). Rigid, poorly deformable sickle RBCs block microvasculature, causing ischemia, pain, and organ damage. The microfluidic impedance red cell assay (MIRCA) can mechanically measure RBC deformability, providing occlusion index under NOI or hypoxia (HOI) as readouts. We analyzed RBCs from 68 adult and 34 pediatric patients with SCD using the MIRCA. Higher HOI and NOI values were positively associated with markers of inflammation, hemolysis, RBC density, older age, and severe SCD genotypes (homozygous HbSS or HbS β0-thalassemia. Each 1% higher NOI across individuals was associated with a 6.3% higher incidence of acute complications per year. Individuals with chronic complications in the past year had a 3.1% higher median NOI than those without chronic complications. Individuals on chronic transfusion therapy exhibit a subpopulation of poorly deformable RBCs captured by the MIRCA but not by a commercially available device that also measures RBC deformability, the laser assisted optical rotational cell analyzer (LoRRca). In vitro addition of voxelotor or osivelotor to samples from individuals on chronic transfusion therapy improved the deformability of these endogenous RBCs. Longitudinally collected NOI and HOI values in individuals with HbSS were stable, with a median percent point change of 13.3% and 15.7%, respectively. MIRCA can be used in combination with clinical laboratory tests to monitor RBC deformability as a biomarker of clinical status at routine clinic visits and included in clinical trials of disease-modifying agents.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Contact Activation in Dielectric Blood Coagulometry: A Comparison of Screen-Printed and Sputtered Gold Electrodes of ClotChip Microfluidic Sensor
This paper investigates the effect of surface roughness on the kinetics of whole blood coagulation through a comparative study of two different electrode fabrication techniques, screen-printing and sputtering, for a microfluidic dielectric sensor termed ClotChip. Featuring a three-dimensional, parallel-plate, capacitive sensing structure with gold sensing and floating electrodes deposited on polymethyl methacrylate plastic substrates, we have previously shown that ClotChip can measure the temporal variation in the normalized real permittivity of a coagulating whole blood sample (peak ) readout parameter. In this work, scanning electron microscope imaging and profilometry measurements reveal that the surface of the sputtered-gold electrode is much smoother than the rough surface of its screen-printed counterpart, having a mean arithmetic average height and root mean square roughness of ∼ 38.0 nm and 47.0 nm versus 5.7 μm and 7.2 μm for the screen-printed electrode. The ClotChip Tpeak parameter has also been measured for both untreated whole blood samples and those modified in vitro with corn trypsin inhibitor, an inhibitor of the activated coagulation factor XII (FXIIa) used to suppress surface-induced coagulation by contact activation. Our results establish that surface-induced, FXIIa-mediated contact activation plays a more prominent role in accelerating the kinetics of whole blood coagulation for rough screen-printed electrodes than for smooth sputtered electrodes.
- 3 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Contact Activation in Dielectric Blood Coagulometry: A Comparison of Screen-Printed and Sputtered Gold Electrodes of ClotChip Microfluidic Sensor
This paper investigates the effect of surface roughness on the kinetics of whole blood coagulation through a comparative study of two different electrode fabrication techniques, screen-printing and sputtering, for a microfluidic dielectric sensor termed ClotChip. Featuring a three-dimensional, parallel-plate, capacitive sensing structure with gold sensing and floating electrodes deposited on polymethyl methacrylate plastic substrates, we have previously shown that ClotChip can measure the temporal variation in the normalized real permittivity of a coagulating whole blood sample (peak ) readout parameter. In this work, scanning electron microscope imaging and profilometry measurements reveal that the surface of the sputtered-gold electrode is much smoother than the rough surface of its screen-printed counterpart, having a mean arithmetic average height and root mean square roughness of ∼ 38.0 nm and 47.0 nm versus 5.7 μm and 7.2 μm for the screen-printed electrode. The ClotChip Tpeak parameter has also been measured for both untreated whole blood samples and those modified in vitro with corn trypsin inhibitor, an inhibitor of the activated coagulation factor XII (FXIIa) used to suppress surface-induced coagulation by contact activation. Our results establish that surface-induced, FXIIa-mediated contact activation plays a more prominent role in accelerating the kinetics of whole blood coagulation for rough screen-printed electrodes than for smooth sputtered electrodes.
- 30 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116352
A miniaturized wash-free microfluidic assay for electrical impedance-based assessment of red blood cell-mediated microvascular occlusion
- 30 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116352
A miniaturized wash-free microfluidic assay for electrical impedance-based assessment of red blood cell-mediated microvascular occlusion
- Open Access
- 11 November 2023
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 7, 100389
OC 15.5 Detection of TIC-Relevant Phenotypes using Bioactive Reagent-Functionalized Dielectric Coagulometry Microsensors
- 11 November 2023
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 7, 100389
Open AccessOC 15.5 Detection of TIC-Relevant Phenotypes using Bioactive Reagent-Functionalized Dielectric Coagulometry Microsensors