Contact Activation in Dielectric Blood Coagulometry: A Comparison of Screen-Printed and Sputtered Gold Electrodes of ClotChip Microfluidic Sensor
- 3 June 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (7) , 1-4
Abstract
This paper investigates the effect of surface roughness on the kinetics of whole blood coagulation through a comparative study of two different electrode fabrication techniques, screen-printing and sputtering, for a microfluidic dielectric sensor termed ClotChip. Featuring a three-dimensional, parallel-plate, capacitive sensing structure with gold sensing and floating electrodes deposited on polymethyl methacrylate plastic substrates, we have previously shown that ClotChip can measure the temporal variation in the normalized real permittivity of a coagulating whole blood sample (peak ) readout parameter. In this work, scanning electron microscope imaging and profilometry measurements reveal that the surface of the sputtered-gold electrode is much smoother than the rough surface of its screen-printed counterpart, having a mean arithmetic average height and root mean square roughness of ∼ 38.0 nm and 47.0 nm versus 5.7 μm and 7.2 μm for the screen-printed electrode. The ClotChip Tpeak parameter has also been measured for both untreated whole blood samples and those modified in vitro with corn trypsin inhibitor, an inhibitor of the activated coagulation factor XII (FXIIa) used to suppress surface-induced coagulation by contact activation. Our results establish that surface-induced, FXIIa-mediated contact activation plays a more prominent role in accelerating the kinetics of whole blood coagulation for rough screen-printed electrodes than for smooth sputtered electrodes.Keywords
This publication has 14 references indexed in Scilit:
- A Multichannel Portable Platform With Embedded Thermal Management for Miniaturized Dielectric Blood CoagulometryIEEE Transactions on Biomedical Circuits and Systems, 2023
- Assessment of fibrinolytic status in whole blood using a dielectric coagulometry microsensorBiosensors and Bioelectronics, 2022
- Monitoring DOACs with a Novel Dielectric Microsensor: A Clinical StudyThrombosis and Haemostasis, 2020
- A novel, point‐of‐care, whole‐blood assay utilizing dielectric spectroscopy is sensitive to coagulation factor replacement therapy in haemophilia A patientsHaemophilia, 2019
- Assessment of whole blood coagulation with a microfluidic dielectric sensorJournal of Thrombosis and Haemostasis, 2018
- ClotChip: A Microfluidic Dielectric Sensor for Point-of-Care Assessment of HemostasisIEEE Transactions on Biomedical Circuits and Systems, 2017
- Principles of Dielectric Blood Coagulometry as a Comprehensive Coagulation TestAnalytical Chemistry, 2015
- The effect of corn trypsin inhibitor and inhibiting antibodies for FXIa and FXIIa on coagulation of plasma and whole bloodJournal of Thrombosis and Haemostasis, 2014
- Dielectric modelling of erythrocyte aggregation in bloodJournal of Physics D: Applied Physics, 2007
- Biomaterial-associated thrombosis: roles of coagulation factors, complement, platelets and leukocytesBiomaterials, 2004