JMJinyu Ma

Jinyu Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jinyu Ma has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Xinjing Huang

    State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, China

    9 shared publications
  • Jian Li

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China

    4 shared publications
  • Jian Li

    State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People’s Republic of China

    2 shared publications
  • Li Jian

    State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People’s Republic of China

    2 shared publications
  • Zhang Tao

    Tianjin Institute of Metrology Supervision and Testing, Tianjin, People’s Republic of China

    2 shared publications
  • Zhang Zhipeng

    State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People’s Republic of China

    2 shared publications

Latest Publications

  • 3-D Localization of In-Service Deep-Buried PE Pipelines via ELF Magnetic Matching: System Design and Field Validation

    by Mingrui Zhang, Ke Liu, Ningfeng Zhang, Junzhe Shi, Jinyu Ma, Xinjing Huang

    The non-conductive and non-magnetic properties of polyethylene (PE), combined with the severe attenuation of acoustic and electromagnetic waves by soil, render 3D localization of deep-buried, in-service PE gas pipelines a significant challenge. This study presents a 3D localization system based on extremely low frequency (ELF) magnetic field matching, consisting of a high-current ground magnetic station and a Φ17 mm miniature spherical detector (SD). The station generates penetrative ELF fields through large wire loops, while the SD is deployed through existing purge valves without interrupting gas service. Trajectory reconstruction is achieved by matching the magnetic fields measured by the SD to a precomputed field map under kinematic constraints, rather than by relying on long-distance inertial dead reckoning. Furthermore, system scaling laws are established, demonstrating that localization uncertainty can be reduced by increasing wire loop current and employing large-scale wire loops to maintain deep-buried pipelines within the magnetic near-field region. In field tests on a 140 m PE pipeline buried at about 4.5 m depth, repeated localization experiments were conducted. The deviation between the mean of three repeated runs and the commercial SINS results is 0.32 m, with a repeatability precision of 0.07 m. These results verify the system’s effectiveness for high-precision, nondestructive localization of buried urban in-service PE gas pipelines.

  • Alignment method based on direct establishment of global world coordinate system for 3D laser vibrometry

    by Huang Xinjing, Lai Ruqiang, Zhang Zhipeng, Zhang Tao, Li Zhengzhe, Li Jian, Ma Jinyu

    Three-dimensional (3D) full-field scanning laser Doppler vibrometry represents one of the most significant non-contact vibration measurement technologies currently available. Among its core components, 3D alignment and laser vibrometry constitute the two most critical technical elements. 3D alignment obtains the rotation matrices from the local probe coordinate system (PCS) to the global world coordinate system (WCS), thereby mapping non-orthogonal vibration components measured along three laser beam directions by three probes into the orthogonal WCS. However, existing alignment methods demonstrate significant dependence on calibration plates or additional measurement equipment, while exhibiting limited adaptability to complex curved structures, thus constraining their engineering applications. To address this issue, this paper proposes a 3D alignment algorithm based on the developed mathematical model of 2D rotating mirror outgoing light rays that directly establishes the global WCS on the measured object surface. This method utilizes the geometric constraint relationships between multiple laser beam’s direction vectors and the WCS when multiple probes illuminate the same point, thereby solving for the transformation matrix from the PCS to the WCS. This approach eliminates the dependence on calibration plates or feature points that is characteristic of conventional methods. Experimental results demonstrate that the method achieves maximum average relative errors of 2.85% and 6.53% in planar and curved surface alignment scenarios, respectively, while simultaneously enabling 3D full-field laser scanning. Compared to existing technologies, the proposed method exhibits significant advantages in terms of scenario adaptability and engineering practicality.


  • Automatic pipeline leak detection based on AST deep learning using a free-swimming detector with acoustic resonance cavity

    by Jian Li, Xiaofeng Yin, Zhang Tao, Xiaoyu Ren, Jinyu Ma, Xinjing Huang

    The free-swimming in-pipe spherical detector (SD) has found practical application in pipeline leak detection due to its proximity to the leak points, low risk of obstruction, and low cost. Acoustic resonance air cavity (ARAC) design enables the SD to capture small leak acoustic signals with high sensitivity, but it simultaneously renders the SD highly vulnerable to collision noise interference, increasing the difficulty of leak identification. For long-time-series acoustic data acquired by the SD, traditional manual analysis methods are inefficient and difficult to ensure accuracy. Additionally, valid leak samples of field pipelines are insufficient, and the actual leak events represent an extremely low proportion, which makes the collection result in a small sample imbalance dataset. To address these issues, this paper proposes an automatic identification method for pipeline leak sounds collected by the SD via incorporating Audio Spectrogram Transformer (AST) deep learning. First, a pipeline leak voice dataset is constructed using the field pipeline acoustic signals captured by the SD, which contained three types of acoustic events: normal rolling, collision, and leak. Second, the problems of category imbalance and sample insufficiency are addressed by combining data augmentation and transfer learning. Finally, the AST model is applied to pipeline leak sound identification and leak point localization. Experiments under different pressure conditions show that this method can accurately identify and locate 1mm aperture leaks, and the localization errors under 1MPa and 0.5MPa conditions are 2.46m and 3.07m, with relative errors of 0.37% and 0.47%, respectively. This research provides a new solution for the automation and intelligence of pipeline leak detection and localization, with good engineering application prospects.


  • Design and Test of Pipeline Leak Detector With Acoustic Resonance Air Cavity

    by Huang Xinjing, Ren Xiaoyu, Wang Liang, Bian Xu, Li Jian, Ma Jinyu

    Early detection of continuous small leaks in pipeline infrastructure is crucial for preventing major failures, yet existing methods often struggle with sensitivity limitations and practical deployment challenges. This paper presents an innovative approach using a spherical detector (SD) with an acoustic resonant air cavity (ARAC), which addresses these challenges by combining the advantages of free-swimming mobility with enhanced acoustic sensitivity. The ARAC design leverages acoustic resonance principles to amplify leak-induced sounds, while the SD’s mobility allows direct access to leak locations within pipelines. Through systematic investigation of cavity dimensions and resonance modes via finite element analysis, we establish the relationship between ARAC size and detection sensitivity. Laboratory experiments with multiple SD prototypes demonstrate that larger cavities (>96mm diameter) achieve superior sensitivity by effectively capturing low-frequency (100-5000 Hz) leak signals through their first three resonance modes. A signal processing algorithm combining wavelet decomposition and adaptive thresholding is developed to distinguish leak signals from mechanical impacts, achieving detection rates exceeding 95% for leaks 0.6-1.0mm in diameter. Field validation tests with an optimized aluminum SD prototype confirm reliable detection of 1mm leaks under both high (1 MPa) and low (0.5 MPa) pressure conditions while rolling through operational pipelines. Quantitative analysis reveals that the system maintains effective detection capability even under challenging field conditions, with the algorithm successfully filtering out interference from pipe wall collisions and environmental noise. These findings demonstrate the practical viability of ARAC-based detection technology for pipeline infrastructure monitoring and maintenance.


  • Parameter Optimization of Electromagnetic Sensing and Driving Scheme of a Compact Falling-body Viscometer

    by Kun Zhang, Hongbin Zhang, Yuan Xue, Jinyu Ma, Jiqing Han, Xinjing Huang

    In order to achieve automatic fast reset of the falling-body (FB) viscometer, and reduce the volume of the device and the amount of sample used, this paper proposes to use a single coil to reset the FB and use another single coil to measure the FB position. In this paper, the characterization ability of the sensing coil impedance to the FB position and its influencing factors, and the reset ability of the driving coil to the FB and its enhancement factors, are studied via electromagnetic finite element simulations and experiments. There is a linear zone between the FB position and the sensing coil impedance, with the slope being largest. The lower limit of the FB motion should be designed in this linear zone to accurately determine the moment when the FB reaches the lower limit point. Increase in the FB height, and in the number of turns of the sensing coil, and decrease in the wire diameter are beneficial to the FB positioning. There is a maximum force point when the FB approaches the driving coil, and the FB’s motion range needs to cover this point for reliable reset. Using iron plugs allows the FB to obtain greater electromagnetic attraction and ensure its successful reset. Experimental results show that the device requires only 1 mL of sample to measure liquid viscosity. For 9.5-1265 mPa⋅s dimethyl silicone oil, the average absolute value of the relative measurement error is 0.22% and the maximum value is 4.3%.

  • Distributed Stress Measurement in Steel Plates Based on Remnant Magnetization and Magnetoelastic Effect

    by Hongbin Zhang, Yuan Wang, Qian Chen, Jinyu Ma, Jian Li, Xinjing Huang

    In this paper, we propose a highly consistent and sensitive method for steel plate stress measurement based on strong remnant magnetization and magnetoelastic effect. Firstly, the J-A force-magnetic coupling model is theoretically improved, and the influencing factors of the force-magnetic coupling strength are investigated via parameter sweeping, and it is determined that the magnetization can reduce the initial permeability to improve the sensitivity and consistency of the stress measurement. Then the equation of the coil electromagnetic impedance change in the magnetic circuit vs the stress is deduced, and it is obtained that the stress has a negative linear relationship with the coil impedance and the sensitivity increases with the increase of the excitation frequency, which is verified by the single-point stress measurement experiment of the sandwich steel plates. Finally, the distributed stress measurement experiments of sandwich steel plates are carried out, which proved that the impedance values at different measurement points after the steel plates are magnetized can successfully reflect the distribution state of the stress. After magnetization, the stress measurement sensitivity of the electromagnetic impedance method increases on average from 0.014 Ω/MPa before magnetization to 0.037 Ω/MPa, with an enhancement of 2.6 times. The measurement accuracy under different loads increases on average from 50.699 MPa before magnetization to 7.078 MPa, with an enhancement of 7.2 times.


  • Far-Field Acoustic Imaging Enhancement Using Compact Graded Refractive Index Metamaterials

    by Zan Li, Jinyu Ma, Jian Li, Xinjing Huang

    Acoustic metamaterials (AMMs) are promising in high-performance acoustic detection and imaging; however, few can be combined with sensors to form a practical detector, and most imaging attempts use under near-field conditions. This paper provides a systematic method of using a compact graded refractive index (GRIN) AMM with an embedded microelectromechanical systems (MEMS) microphone to enhance far-field acoustic sensing and imaging. The GRIN AMM device has frequency selective amplification capability and noticeable directivity; these attributes can increase the detection range, suppress the aliasing of the multitarget main and grating lobes, and support arrays with large element separation and high angular resolution. An imaging enhancement mechanism using the GRIN AMMs is proposed and elucidated. Experiments demonstrate that the improved phased array with compact AMMs can image a 315 mm pipe as far as 67 m away and has an angular resolution up to 0.76°. Finally, the improved acoustic imaging system with an AMM array is transplanted to an FPGA-based robot to demonstrate active acoustic target-tracking application in the field.


  • A localization method for subsea pipeline based on active magnetization

    by Xinjing Huang, Yuan Wang, Jinyu Ma, Jialin Wu, Jian Li, Yu Zhang, Hao Feng

    Accurate location of subsea pipelines is a prerequisite for real-time tracking and detailed inspections by underwater robots. The magnetic anomalies generated by ferromagnetic pipelines can be used to locate both exposed and buried pipelines. However, due to the low signal ratio and model inconsistencies under weak and variable ambient magnetization, there is currently no intuitive and reliable pipeline detection method for pipeline tracking. This paper proposes a method capable of immediately and accurately locating pipelines via active magnetization and vertical magnetic measurements. Finite element simulations show that a magnet array can significantly enhance the magnetic anomaly, and that the vertical magnetic component alone can accurately indicate the pipeline’s position, avoiding the inconvenience of magnetic three-component alignment in the field. It is experimentally demonstrated that the magnetic detection signal-to-noise ratio can be significantly increased by 5 dB–20 dB for a Φ219 mm steel pipe using the magnet array, and the maximum lateral positioning error is 0.03 m and much smaller than that without the magnet array.