JCJiehao Cui

Jiehao Cui

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiehao Cui has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A New Quantitative Analysis Method for Overvoltage in Sending End Electric Power System With UHVDC

    by Ancheng Xue, Lei Yue, Jiahuan Zhang, Jiehao Cui, Zhiqiang Li, Yecheng Li, Lei Gao, Weifang Lin, Xiaoyu Ren

    With the development of renewable electric power generation and ultra-high voltage direct current (UHVDC) transmission, the transient overvoltage in the sending end electric power system with UHVDC occurs, but it is lack of quantitative transient voltage assessment index (TVAI) to assess the overvoltage. To deal with the above problems, this paper proposes a new quantitative transient voltage assessment index considering overvoltage and voltage dip in the sending end electric power system with UHVDC, and applies it to analyze different influencing factors of overvoltage and determine the dynamic reactive power compensation capacity. In detail, first, according to the principle of the transient voltage assessment index considering voltage dip and the overvoltage assessment index for the distribution network, a new transient voltage assessment index considering transient overvoltage in the sending end electric power system with UHVDC is proposed with the approximated step function. Then, based on the requirements of the system with UHVDC, the parameters of the proposed transient voltage assessment index are determined. Furthermore, with the absolute and relative sensitivity, the impact of the parameters of voltage dependent current order limiter and current control amplifier on the transient overvoltage is analyzed and compared quantitatively. Finally, the impact of reactive power compensation equipment, such as synchronous condenser, static var compensator, and static var generator, on the transient overvoltage of the system with UHVDC is compared quantitatively, and the reactive compensation capacity needed to maintain transient voltage security and stability is estimated. The two applications show the effectiveness and advantages of the proposed index in the sending end electric power system with UHVDC.


  • Open Access

    Transient Frequency Stability Emergency Control for the Power System Interconnected With Offshore Wind Power Through VSC-HVDC

    by Ancheng Xue, Jiahuan Zhang, Lijun Zhang, Yikai Sun, Jiehao Cui, Jiawei Wang

    For the power system interconnected with the large-scale offshore wind power through VSC-HVDC, such as SZ power grid, it may be engaged with transient frequency stability and lack of related control due to the randomness, fluctuation and intermittence of the wind. This paper proposes a transient frequency control strategy for the power system interconnected with offshore wind power through VSC-HVDC based on sensitivity. Firstly, the structure of SZ power grid and the calculation method of transient frequency stability index are introduced, and the transient frequency problems existing in SZ power grid are explored. Secondly, the mathematical formulation for the transient frequency control is described, including the objective function and the constraints. Furthermore, a transient frequency emergency control strategy based on special sequence and the sensitivities is proposed, which includes thermal units regulation, wind power regulation, DC modulation and load shedding. Finally, the effectiveness of the proposed control strategy is verified by simulation in SZ power grid.